• Title/Summary/Keyword: Korean turn

Search Result 5,162, Processing Time 0.041 seconds

Design of an Optimum Thyristor Snubber Circuit with Turn-off Model (다이리스터의 Turn-off 모델을 이용한 최적 Snubber 회로 설계)

  • Kim, Kwon-Ho;Moon, Yong-Hyun;Song, Joong-Ho;Chy, Ick;Kim, Kwang-Bae
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.773-776
    • /
    • 1993
  • The thyristor turn-off model plays an important part in the design of thyristor snubber circuit. However, it is difficult to determine the thyristor turn-off characteristics. In this paper two methods to establish the simple thyristor turn-off model are proposed based on the reverse recovery characteristics given in the data sheets. Using the simple thyristor turn-off model, the optimum thyristor snubber circuit design procedures are presented considering maximum voltage spike, maximum reverse dv/dt, and turn-off loss.

  • PDF

The Technique of Estimating the Right-Turn Adjustment Factor (우회전 보정계수 산정기법)

  • Kim, Gyeong-Hwan;Kim, Yeong
    • Journal of Korean Society of Transportation
    • /
    • v.19 no.4
    • /
    • pp.73-84
    • /
    • 2001
  • Korean Highway Capacity Manual applies 7 adjustment factors to estimate saturation flows at signalized intersections. Among the adjustment factors, the right-turn adjustment factor uses equation hard to understand and requires complicated computing process comparing other adjustment factors. Thus. this study was conducted in order to suggest a new technique of estimating the right-turn adjustment factor which is easy to understand and simple to computer by having reasonable degree of accuracy. In this study the right-turn saturation flow ratios which are important in estimating the factor are suggested and the equation to estimate the volume of right-turn on red signal(RTOR) is developed based on observed data. The right-turn saturation flow rates can be estimated according to turning radius and number of lanes of crossing road dividing right-turn lanes into canalized and uncanalized lanes. The RTOR volume is estimated using the proportion of the time during which RTOR is possible to the whole time of red signal according to the through traffic volume per lane of the approach at signalized intersections. The technique of estimating the right-turn adjustment factor suggested in this study, which follows the HCM2000 of U.S. in principal, first judges the right-turn lane to be used exclusively for right-turn or not by employing the RTOR factor and the judging equation developed in this study. Next, if the right-turn lane is not exclusive right-turn lane, the shared right-turn lane is classified into single lane approach or multi lane approach. Thus, a total of three methods of estimating the right-turn adjustment factor to the three cases are suggested in this study.

  • PDF

A study on Left turn Capacity by Bay Length (Bay길이에 따른 좌회전 용량산정에 관한 연구)

  • 김정례;김기혁
    • Journal of Korean Society of Transportation
    • /
    • v.20 no.3
    • /
    • pp.31-39
    • /
    • 2002
  • The primary objective of this study is to develop a reliable method for estimating the left turn capacity at the signalized intersection. This study is performed during periods of congestion. Multi left turn lane(bay lane and exclusive lane) approaches are examined. When more than one left turn lane exists, traffic volumes are not distributed equally over each lane. The fundamental approach taken in this study is measuring headways on left turn lanes with altering the bay length from 20m to 120m. Left turn lane is divided into 3 sub-sections in this study. These are SLP section(start-up lost time Period), SFP section(saturation flow period), LSP section(lane selection period). Saturation flow rates are evaluated for each sub section periods. As a results of analysis, it has been confirmed that the left turn capacity can be estimated by left turn bay length and effective green time for left turn. The left turn bay length adjustment factor is suggested in this study.

Efficiency Questions of the Left-turn Prohibit in Case of 4-Leg Intersections with 5-Phase Signal System (5현시 신호체계 4지교차로의 좌회전 금지에 따른 효율성 분석)

  • 변상철;박병호
    • Journal of Korean Society of Transportation
    • /
    • v.14 no.4
    • /
    • pp.91-106
    • /
    • 1996
  • This paper deals with on the efficiency questions of the left-turn prohibit at an isolated intersection and a corridor with 5-phase signal system. Its objectives are three-fold ; (1) to analyze the efficiency of the left-turn prohibit with the use of an imaginary network, (2) to evaluate various factors under consideration in decision making on the left-turn prohibit, (3) to provide a framework for estimating and evaluating overall impacts of the left-turn prohibit in traffic network. the major findings using an imaginary network and computer packages such as MINUTP, TRANSYT-7F and STATGRAPH are followings. First, left-turn prohibit reduces cycle length by 33 seconds and delay time per vehicle by 36 seconds at an isolated intersection, and cycle length by 31 seconds and delay time per veicle by 43 seconds along a corridor. Second, total vehicle mile of travel and total travel time at an isolated intersection seem up to increase 38.85 miles(57.36km), 14.4 hour on the average, Regarding to a corridor, total vehicle mile of travel is increased by 50.14 miles(80.22km), but total travel time is decreased by129.9 hours. Third, the efficiency of left-turn prohibit are affected the following eight factors including left-turn volume(veh/hr) and ratio(%), average delay time per vehicle(sec/veh) and others. Finally, several simple and multiple regression models to evaluate the impacts on the left-turn prohibit are formulated from the above eight factors. It can be expected that these models will take an important role in decision-making of left-turn prohibit.

  • PDF

Development of Inter-Turn Short Circuits Sensor for Rotor Winding of Synchronous Generator (발전기 회전자의 층간단락 감지기 개발)

  • Nam, Jong-Ha;Lee, Seung-Hak;Choe, Gyu-Ha
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.6
    • /
    • pp.307-312
    • /
    • 2002
  • Inter-turn short circuits can have significant effects on a generator and its performance. The Inter-turn short circuits sensor for synchronous generator's field winding has been developed. The sensor, installed in the generator air-gap, senses the slot leakage flux of field winding and produces a voltage waveform proportional to the rate of change of the flux. For identification of reliability for sensor, a shorted- turn test was performed at the Seoinchon combined cycle power plant on gas turbine generator and stim turbine generator. This sensor will be used as a detecting of Inter-turn short circuits for synchronous generator's field winding.

Maximization average torque control of Switched Reluctance Motor using least square method (최소자승법을 이용한 Switched Reluctance Motor의 최대 평균토오크 제어)

  • 김춘삼;정연석
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.5
    • /
    • pp.61-65
    • /
    • 2002
  • RM(Switched Reluctance Motor)'s Torque is generated by phase-current and inductance profile. A new analytical concept is proposed to determine the turn-off angle for maximization of the torque output. This paper describes a new method to maximization the average torque of a current control Switched Reluctance Motor. It is based on the simplified turn-off angle equation using least square method. Simulations carried out on a three-phase 6/4 pole SRM justify the algorithm is described. The suggested maximization average torque is verified by simulation in this paper.

Output Voltage Control Method of a Switched Reluctance Generator using Turn-off Angle Control (소호각 제어를 이용한 Switched Reluctance Generator의 출력 전압 제어)

  • 김영조;전형우;김영석
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.7
    • /
    • pp.356-363
    • /
    • 2001
  • A SRG (Switched Reluctance Generator) has many advantages such as high efficiency, low cost, high-speed capability and robustness compared with other of machine. But the control methods that have been adopted for SRGs are complicated. This paper proposes a simple control method using the PID controller which only controls turn-off angles while keeping turn-on angles of SRG constant. In order to keep the output voltage constant, the turn-off angle for load variations is controlled by using linearity between the generated current and turn-off angle since the reference generated current can be led through the voltage errors between the reference and the actual voltage. The suggested control method enhances the robustness of this system and simplifies the hardware and software by using only the voltage and the speed sensors. The proposed method is verified by experiments.

  • PDF

A Study on Analyzing Effect of Claim Factoy to Prevent Claim in Early Stage for Construction Project - Focusing on Turn-Key Project - (건설 프로젝트 초기단계에서의 클레임 방지를 위한 클레임 요인 영향도 분석에 관한 연구 - 턴키공사 사레 중심으로 -)

  • Yoon Jun-Seon;Seo Choon-Taek
    • Journal of Arbitration Studies
    • /
    • v.15 no.1
    • /
    • pp.95-112
    • /
    • 2005
  • In the inner turn key constructions the problems of uniform types are repeatedly occurred, and, especially, many problems happen up to the stage of pre-construction(from a bid to a contract) owing to the specialties of the turn key constructions. So the claim factors of the Korean turn key constructions were abstracted in antecedent paper. When the technicians meeting the interior turn key constructions for the first time and working here now are well acquainted with only these factors, many claims will be prevented. By analysing the degree of claims by claims factors through the questionnaires to the experts about the abstracted factors and surveying the amount of the claims through the case studies, what factors exerted how much of influence on the claims was tested and analyzed. Studying and Managing the factors affecting the claims much led the technicians in charge of internal turn key constructions to the prevention and the proper solution of the site claims.

  • PDF

A Study on the Socio-economic Effects of U-turn Migration in Rural Area (귀농(歸農)이 농촌사회(農村社會)에 미치는 영향(影響)에 관한 연구(硏究))

  • Kim, Jai-Hong
    • Korean Journal of Agricultural Science
    • /
    • v.25 no.1
    • /
    • pp.138-147
    • /
    • 1998
  • U-turn migration is one of the prominent phenomenon after IMF controlled Korean economy. However a number of U-turn migrants were settled in rural area before that time. This paper is aims at studying the socio-economic effects of U-turn migration in rural area. The study results are summarized as follows; First, migrants are relatively young and engaged in overall parts of the farming. The farmer with age under 50 is represented at 71.4% of migrants comparing with 53.7% of those farmers in rural area. Second, owing to the increasing number of U-turn migrants, the decreasing price of rural wages, the decreasing of idle land, and the increasing price of farm land are the outstanding phenomenon at present. Third, even though there are many kinds of supporting systems for U-turn migrants, the systems are not so successfully functioned. For the successful supporting system they must be changed for the individual migrant rather than target group.

  • PDF

Design of 4.5kV/1.5kA IGCT (4.5kV/1.5kA급 IGCT 설계 및 특성분석)

  • Kim, Hyoung-Woo;Kim, Sang-Cheol;Seo, Kil-Su;Kim, Eun-Dong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07a
    • /
    • pp.357-360
    • /
    • 2003
  • In this paper, we designed 4.5kV/1.5kA IGCT devices. GCT thyristor has many superior characteristics compared with GTO thyristor, for examples; snubberless turn-off capability, short storage time, high turn-on capability, small turn-off gate charge and low total power loss of the application system containing device and peripheral parts such as anode reactor and snubber capacitance. In this paper we designed GCT thyristor devices, and analyzed static and dynamic characteristics of GCT thyristor depending on the minority carrier lifetime, n-base thickness and doping concentration of n-base region, respectively. Especially, turn-on and turn-off characteristics are very important characteristics for GCT thyristor devices. So, we considered above characteristic for design and analysis of GCT devices.

  • PDF