• Title/Summary/Keyword: Korean turn

Search Result 5,162, Processing Time 0.041 seconds

The Dielectric Characteristics of Turn-to-Turn Insulation for DC Reactor Type HTSFCL (DC reactor type 고온호전도 한류기의 턴간 절연 특성)

  • 백승명;정종만;이창화;류엔반둥;김상현
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.12S
    • /
    • pp.1299-1304
    • /
    • 2003
  • Fault current limiters (FCL) are extensively needed to suppress fault currents, especially for trunk power systems heavily connected to high voltage/large current transmission lines. Due to its ideal electrical behavior, high-temperature superconductor fault current limiter (HTSFCL) becomes one of the most important developing trends of limiters in power system. This paper describes the result of an investigation of the dielectric characteristics of turn-to-turn insulation for pancake and solenoid type reactor coil in liquid nitrogen. The influence of thickness in a variety length, on AC, DC and impulse surface flashover has been investigated. Also, the relationships between the number of turn and breakdown characteristics were clarified. The information gathered in this test series should be helpful in the design of liquid nitrogen filled DC reactor type HTSFCL.

Characteristics of Ultra High Frequency Partial Discharge Signals of Turn to Turn Defect in Transformer Oil (절연유 내 변압기 Turn간 결함에 의한 부분방전의 극초단파 전자기파 신호 특성)

  • Yoon, Jin-Yul;Ju, Hyung-Jun;Goo, Sun-Geun;Park, Ki-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.10
    • /
    • pp.2000-2004
    • /
    • 2009
  • In general, for the condition monitoring of a power transformer using the UHF PD measuring technique, detection of any partial discharge, identifying the defect in the transformer and locating the insulation defect are necessary. In this paper one of the most frequent detects which can result in turn to turn fault in power transformer was examined for identifying the defect. In order to model the defect, as a discharge source, a partial discharge cell was used for experimental activity. Magnitude of electromagnetic wave signals and corresponding amount of apparent discharge were measured simultaneously against phase of applied voltage to the discharge cell. Frequency range and phase resolved partial discharge signals were measured and analyzed. The results will be contributed to build the defect database of power transformer and to decrease the occurrence of transformer faults.

Estimation of the Through Car Equivalent for Left-Turn Movement According to the Left-Turn Curve Radius in the Signalized Intersection (신호교차로에서 곡선반경에 따른 좌회전의 직진환산계수 산정)

  • 오영태;김기형
    • Journal of Korean Society of Transportation
    • /
    • v.19 no.2
    • /
    • pp.21-28
    • /
    • 2001
  • This study is to estimate the through car equivalent for left-turn movement according to left turn radius in the signalized intersection. The saturation flow rate for left-turn movement in 92' KHCM(Korea Highway Capacity Manual) is the same as that for through movement in the signalized intersection where the left turn radius is over 20m. This study uses Duncan 'Test's Test in order to find out the saturated position for queued vehicle in the signalized intersection. It found that the saturated flow rate of left-turn movement in the signalized intersection is less than that of through movement where the left-turn radius is less than 20m. It found that the through car equivalents for left-turn movement according to left-turn radius(8m-20m) are between 1.05 and 1.14.

  • PDF

A Study on Installation of U-Turn Lane for Efficient Operation of Left Turn at Signalized Intersections (신호교차로 좌회전 효율적 처리를 위한 유턴차로 설치방법 연구)

  • Park, Chahgwha;Yoon, Byoungjo;Kang, Bongsuk
    • Journal of the Society of Disaster Information
    • /
    • v.11 no.4
    • /
    • pp.597-606
    • /
    • 2015
  • Until now, u-turn lane installation methods have been studied variously. But, There is no specific standard yet. This study ranges are commercial area in Incheon metropolitan city through field investigation and presents specific design standard for efficient operation of left turn using a field data through calculating relevant permitted u-turn lane length and minimum separation distance from the front intersection to starting point of permitted u-turn lane in urban signalized intersections in commercial area. Relevant permitted u-turn lane length is found to be 32m and minimum separation distances from the front intersection to starting point of permitted u-turn lanes are 72m, 40m, 24m in case of 1 left turn lane, 2 left turn lanes and 3 left turn lanes respectively. By comparing result values and field data, they had a large difference under the similar situations in their lengths. This result is caused of no specific standard about design of u-turn lanes. If results of this study applied to design of u-turn lanes, signalized intersections in urban commercial areas would be operated more safety and efficiently.

Development of the U-turn Accident Model at 4-Legged Signalized Intersections in Urban Areas (도시부 4지 신호교차로 유턴 사고모형 개발)

  • Kang, JongHo;Kim, KyungWhan;Ha, ManBok;Kim, SeongMun
    • International Journal of Highway Engineering
    • /
    • v.16 no.2
    • /
    • pp.119-129
    • /
    • 2014
  • PURPOSES : The purpose of this study is to develop the U-turn accident model at 4-legged signalized intersections in urban areas. METHODS : In order to analyze the characteristics of the accidents which are associated with U-turn operation at 4-legged signalized intersections in urban areas and develop an U-turn accident model by regression analysis, the tests of overdispersion and zero-inflation are conducted about the dependent variables of number of accidents and EPDO (Equivalent Property Damage Only). RESULTS : As their results, the Poisson model fits best for number of accident and the ZIP (Zero Inflated Poisson) fits best for EPOD, the variables of conflict traffic, width of opposing road, traffic passing speed are adopted as independent variable for both models. The variables of number of bus berths and rate of U-turn signal time at which the U-turn is permitted are adopted as independent variable only for EPDO. CONCLUSIONS : These study results suggest that U-turn would be permitted at the intersection where the width of opposing road is wider than 11.9 meters, the passing vehicle speed is not high and U-turn operation is not hindered by the buses stopping at bus stops.

An Improved Gate Control Scheme for Overvoltage Clamping Under High Power IGBTs Switching (대용량 IGBT 스위칭 시 과전압 제한을 위한 향상된 게이트 구동기법)

  • 김완중;최창호;이요한;현동석
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.3 no.3
    • /
    • pp.222-230
    • /
    • 1998
  • This paper proposes a new gate drive circuit for high power IGBTs which can reduce the harmful effect of reverse recovery current at turn-on and actively suppress the overvoltage across the driven IGBT at turn-off without a snubber circuit. The turn-on scheme decreases the rising rate of the collector current by inereasing the input capacitance at turn-on transient when the gate-emitter voltage goes above threshold voltage. It results in soft transient of the reverse recovery current with no variation in turn-on delay time. The turn-off driving scheme has adaptive feature to the amplitude of collector current, so that the overvoltage can be limited much effectively at the fault collector current. Experimental results under various normal and fault conditions prove the effectiveness of the proposed circuit.

  • PDF

Traffic Signal Timing at Interconnected and Semi-Protected-Left-Turn Intersections for Energy Saving (에너지절약을 위한 상호련결된 반보호좌회전 교차로의 신호시간설계)

  • 김경환
    • Journal of Korean Society of Transportation
    • /
    • v.8 no.1
    • /
    • pp.25-40
    • /
    • 1990
  • This study was undertaken to develop a traffic signal timing method for interconnected and semi-protected-left-turn intersections(the intersections which have left-turn signal but not exclusive left-turn lanes) on four-lane streets for energy saving and to computerize the method for the practical use. For this study, a probability model which could estimate the utilized time of the shared left-turn lane by through traffic during green period was developed based on field studies. The two left-turn treatments, leading and lagging left-turns, were tested for the intersections, and it can be concluded that the leading left-turn was more efficient for the normal urban streets on which through traffic is major traffic. Adopting the leading left-turn macro-models to estimate vehicular average delay and proportions of vehicles stopped at the intersections were developed. Using the two models as well as the idling fuel consumpution rate and the excess fuel consumption per stop-go speed change, a traffic signal timing method for the intersections for energy saving was developed and computerized. The method can be used for more than four-lane streets and for other measures of effectiveness such as minimum delay, minimum stop rates, etc.

  • PDF

Determination of Optimal Turn-off Angle for SRM Converter Using Self-Tuning Method (SRM 컨버터에서 자기동조 방식에 의한 턴오프 각의 결정)

  • 장도현;문진영
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.3 no.4
    • /
    • pp.418-425
    • /
    • 1998
  • In this paper. determination method of turn-off angle in the SRM drives is proposed to maintain the high torque at a any turn-on angle, which is realized by using selHuning control method, During the sampling time. a number of P pulses from encoder are checked by using one-chip microprocessor. and compared with pre-checked a number of pulses A After calculating difference between two data, the turn-off angle moves forward or backward direction by the self-tuning m method, As repeating such process, the optimal turn-off angle is determined and the maximum torque is maintained T Though experiments, it is observed that motor speed is almost maintained if turn-off angle is adjusted automatically by s selHuning method when turn-ηn angle is changed.

  • PDF

The Impact of Parasitic Elements on Spurious Turn-On in Phase-Shifted Full-Bridge Converters

  • Wang, Qing
    • Journal of Power Electronics
    • /
    • v.16 no.3
    • /
    • pp.883-893
    • /
    • 2016
  • This paper presents a comprehensive analysis of the spurious turn-on phenomena in phase-shifted full-bridge (PSFB) converters. The conventional analysis of the spurious turn-on phenomenon does not establish in the PSFB converter as realizing zero voltage switching (ZVS). Firstly, a circuit model is proposed taking into account the parasitic capacitors and inductors of the transistors, as well as the parasitic elements of the power circuit loop. Second, an exhaustive investigation into the impact of all these parasitic elements on the spurious turn-on is conducted. It has been found that the spurious turn-on phenomenon is mainly attributed to the parasitic inductors of the power circuit loop, while the parasitic inductors of the transistors have a weak impact on this phenomenon. In addition, the operation principle of the PSFB converter makes the leading and lagging legs have distinguished differences with respect to the spurious turn-on problems. Design guidelines are given based on the theoretical analysis. Finally, detailed simulation and experimental results obtained with a 1.5 kW PSFB converter are given to validate proposed analysis.