• Title/Summary/Keyword: Korean sponge

Search Result 659, Processing Time 0.024 seconds

Bone regenerative effect of recombinant human bone morphogenetic protein-2 after cyst enucleation

  • Hwang, Doo Yeon;On, Sung Woon;Song, Seung II
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.38
    • /
    • pp.22.1-22.6
    • /
    • 2016
  • Background: The aim of this study is to quantitatively evaluate the effect of rhBMP-2 for repair of bone defects after cyst enucleation using the osteogenesis index (OI). Methods: Under general anesthesia, 10 patients (12 lesions) underwent oral or maxillofacial surgery for cyst enucleation. Postoperatively, 12 lesions were divided into two groups: group A (six lesions) was treated with absorbable collagen sponge (ACS) in combination with rhBMP-2, and group B (six lesions) was treated with ACS alone. After 3 months, cone-beam computed tomographic scans were obtained to measure changes in the volume of the lesions. We then calculated the OI of each group at two different Hounsfield units to determine any statistically significant difference between these two groups (Mann-Whitney U test). Results: As tested at the level of new bone, the mean OI was 72.37 % in group A and 55.08 % in group B -a statistically significant difference (p = 0.041). As tested at the level of mature bone, the mean OI was 27.47 % in group A and 18.88 % in group B, but the difference was not statistically significant (p = 0.394). Conclusions: The application of rhBMP-2 after maxillofacial cyst enucleation accelerated new bone formation in the bone defects. Thus, the use of rhBMP-2 in combination with ACS may be considered an alternative to conventional bone grafting in some patients with postoperative bone defects.

Biocompatibility and Bone Conductivity of Porous Calcium Metaphosphate Blocks (생분해성 다공질 Calcium Metaphosphate 블록의 조직적합성에 관한 연구)

  • Lee, Yong-Moo;Kim, Seok-Young;Shin, Seung-Yun;Ku, Young;Rhyu, In-Chul;Chung, Chong-Pyoung
    • Journal of Periodontal and Implant Science
    • /
    • v.28 no.4
    • /
    • pp.559-568
    • /
    • 1998
  • direct bone apposition during bone remodelling. To address these problem, we developed a new ceramic, calcium metaphosphate(CMP), and report herein the biologic response to CMP in subcutaneous tissue, muscle and bone. Porous CMP blocks were prepared by condensation of anhydrous $Ca(H_2PO_4)_2$ to form non-crystalline $Ca(PO_3)_2$. Macroporous scaffolds were made using a polyurethane sponge method. CMP block possesses a macroporous structure with approximate pore size range of 0.3-1mm. CMP blocks were implanted in 8mm sized calvarial defect, subcutaneous tissue and muscle of 6 Newzealand White rabbits and histologic observation were performed at 4 and 6 weeks later. CMP blocks in subcutaneous tissue and muscle were well adapted without any adverse tissue reaction and resorbed slowly and spontaneously. Histologic observation of calvarial defect at 4 and 6 weeks revealed that CMP matrix were mingled with and directly apposed to new bone without any intervention of fibrous connective tissue. CMP blocks didn't show any adverse tissue reaction and resorbed spontaneously also in calvarial defect. This result revealed that CMP had a high affinity for bone and was very biocompatible. From this preliminary result, it was suggested that CMP was a promising ceramic as a bone substitute and tissue engineering scaffold for bone formation.

  • PDF

Circular RNA hsa_circ_0075828 promotes bladder cancer cell proliferation through activation of CREB1

  • Zhuang, Chengle;Huang, Xinbo;Yu, Jing;Gui, Yaoting
    • BMB Reports
    • /
    • v.53 no.2
    • /
    • pp.82-87
    • /
    • 2020
  • Circular RNAs (circRNAs), one kind of non-coding RNA, have been reported as critical regulators for modulating gene expression in cancer. In this study, microarray analysis was used to screen circRNA expression profiles of bladder cancer (BC) 5637 cells, T24 cells and normal control SV-HUC-1 cells. The data from the microarray showed that hsa_circ_0075828 (named circCASC15) was most highly expressed in 5637 and T24 cells. circCASC15 was highly expressed in BC tissues and cells. Overexpression of circCASC15 was closely associated with BC tumor stage and promoted cell proliferation significantly in vitro and in vivo. Mechanistically, circCASC15 could act as miR-1224-5p sponge to activate the expression of CREB1 to promote cell proliferation in BC. In short, circCASC15 promotes cell proliferation in BC, which might be a new molecular target for BC diagnosis and therapy.

Development of the testing method for vinyl chloride monomer (VCM) in polyvinyl chloride(PVC) samples (PVC 제품에서의 염화비닐 단량체 정량분석 방법에 관한 연구)

  • Kweon, Deok-Jun;Choi, Ki-In;Eom, Hui-Jeong;Lee, Jae-In;Choi, Zel-Ho
    • Analytical Science and Technology
    • /
    • v.25 no.6
    • /
    • pp.395-401
    • /
    • 2012
  • This study presents a method for the quantitative analysis of residual vinyl chloride monomer (VCM) in PVC products. In elution solvent, the extraction efficiency was similar by ethanol, THF, and acetone, but using n-hexane, it indicated relatively low extraction efficiency. Measuring VCM in the pulverized PVC samples, it showed reasonable results in both the direct injection method and headspace method with GC/MS. Regarding analysis of VCM in the intermediate sponge samples, five laboratories showed good results, and from the results, it was considered that VCM quantitative method in this study was reliable.

Development and Succession of Marine Fouling Organisms on Artificial Substrata (인조기판 위에서 해양 부착생물의 발달 및 천이)

  • 심재형;정문섭
    • 한국해양학회지
    • /
    • v.22 no.4
    • /
    • pp.257-270
    • /
    • 1987
  • Fouling communities developing in Jinhae Harbor and Masan Bay were studied by slide and panel immersion test during the period from Dec., 1982 to Nov., 1983. The total viable count of bacteria was estimated more than 1.7${\times}$ 10$\^$4/CFU/$\textrm{cm}^2$ after 15 days of immersion and 46 taxa of benthic diatoms were classified in micro-community. Progressional change of fouling communities was clearly shown and dominant diatom species are Licmophora flavellata, Navicula grevillei, and Nitzschia closterium Major macrofouling organisms are Mytilus edulis, Balanus amphitrite amphitrite, Hydroides ezoensis, and Celleporina sp. Wet weight production of macrofouling organisms exceeds 500g/100cm$\^$2/ after 5months of immersion. Regional defferences in community development are clearly shown in two study areas, and mainly due to the disparities of physicochemical stability and nutritional status of ambient water. Seasonality of larvae and the growth rate are the important factors in fouling community development. Overall process of community development is as follow : bacteria and diatoms-multicellular algae-barnacle, mussels and polychaete-sponge, anemone and ascidian.

  • PDF

Characterization of Actinomyces Isolated from Freshwater Sponges in Lake Baikal (바이칼의 담수 스폰지에서 분리한 방선균의 특성 연구)

  • Jung, You-Jung;Joung, Yo-Chan;Ahn, Tae-Seok
    • Korean Journal of Microbiology
    • /
    • v.47 no.2
    • /
    • pp.130-136
    • /
    • 2011
  • Five strains of Actinomyces were isolated from freshwater sponges, Baikalospongia and Lubomirskia, in Lake Baikal. By 16S rRNA sequencing, isolates were identified as Streptomyces griseoplanus, S. halstedii, S. violascens, S. flavovirens, and S. microflavus. Isolates had different characteristics of growth temperature, carbon utilization, enzyme activity, and cellular fatty acid composition. Optimum growth conditions of isolates were $30-37^{\circ}C$, pH 8-9, and 0-1.5% salt concentrations. Major fatty acid compositions were anteiso-$C_{15:0}$, iso-$C_{15:0}$, and iso-$C_{16:0}$. Strain ATS-BA-19 had DNase and chitinase activities and strain ATS-BA-16 had cellulase and protease activities. Colonies of strain ATS-BA-15 and ATS-BA-19 made inhibition zone of Pseudomonas aeruginosa.

In Vitro and In Vivo Evaluation of Composite Scaffold of BCP, Bioglass and Gelatin for Bone Tissue Engineering

  • Kim, Woo Seok;Nath, Subrata Deb;Bae, Jun Sang;Padalhin, Andrew;Kim, Boram;Song, Myeong Jin;Min, Young Ki
    • Korean Journal of Materials Research
    • /
    • v.24 no.6
    • /
    • pp.310-318
    • /
    • 2014
  • In this experiment, a highly porous scaffold of biphasic calcium phosphate (BCP) was prepared using the spongereplica method. The BCP scaffold was coated with 58S bioactive glass (BG) and sintered for a second time. The resulting scaffold was coated with gelatin (Gel) and cross-linked with [3-(3-dimethyl aminopropyl) carbodiimide] and N-Hydroxysuccinamide (EDC-NHS). The initial average pore size of the scaffold ranged from 300 to $700{\mu}m$, with more than 85 % porosity. The coating of BG and Gel had a significant effect on the scaffold-pore size, decreasing scaffold porosity while increasing mechanical strength. The material and surface properties were evaluated by means of several experiments involving scanning electron microscopy (SEM), energy-dispersive X-ray (EDX) and X-ray diffraction (XRD). Cytotoxicity was evaluated using MTT assay and confocal imaging of MC3T3-E1 pre-osteoblast cells cultured in vitro. Three types of scaffold (BCP, BCP-BG and BCP-BG-Gel) were implanted in a rat skull for in vivo evaluation. After 8 weeks of implantation, bone regeneration occurred in all three types of sample. Interestingly, regeneration was found to be greater (geometrically and physiologically) for neat BCP scaffolds than for two other kinds of composite scaffolds. However, the other two types of scaffolds were still better than the control (i.e., defect without treatment).

A Case of Intramuscular Abscess in the Sternocleidomastoid Muscle after Intramuscular Stimulation (IMS) (근육내 자극요법 후 목빗근내 농양의 치험례)

  • Kim, Jae-In;Choi, Hwan-Jun;Choi, Chang-Yong;Yang, Hyung-Eun
    • Archives of Plastic Surgery
    • /
    • v.37 no.2
    • /
    • pp.182-186
    • /
    • 2010
  • Purpose: Intramuscular stimulation (IMS) shows good results in the treatment of chronic pain patients who did not respond to other treatments such as oral analgesics, trigger point injection, nerve block and epidural steroid injection. But, IMS procedure especially, patients with diabetes mellitus (DM) has sometimes serious problem. So, we present a very rare case of intramuscular abscess in the sternocleiomastoid muscle after IMS with literature review. Methods: A 66 year old male visited our department 7 days after IMS in the neck. His premorbid conditions and risk factors of deep neck infection was DM and old age. Computed tomographic scans of the head and neck region were performed in this patient: signs of deep neck infection, were seen enhanced abscess in the sternocleidomastoid muscle, cellulitis overlying tissue of the neck, and air bubbles involved muscle. Necrotic wound was excised serially and we treated this with the Vacuum-assisted closure (VAC, Kinetics Concepts International, San Antonio, Texas) system device. After appropriately shaping the sponge in the pockets, continuous negative pressure of 125 mmHg was applied. The VAC therapy was utilized for a period of 12 days. Results: We obtained satisfactory results from wide excision, drainage of the abscess with the VAC system, and then primary closure. The postoperative course was uneventful. Results: We suggest that many of the infectious complications may be preventable by strict adherence to aseptic techniques and that some of the other complications may be minimized by refining the techniques with a clear understanding of the medical disorders of patients. And, the refined technique using the VAC system can provide a means of simple and effective management for the cervical intramuscular abscess, with better cosmetic and functional results.

Method for Making High Purity Gallium by Electrowinning (전해채취에 의한 Gallium의 정제기술)

  • Choi, Young-Jong;Hwang, Su-Hyun;Jeon, Deok-Il;Han, Kyu-Sung
    • Resources Recycling
    • /
    • v.23 no.6
    • /
    • pp.63-67
    • /
    • 2014
  • Gallium is an important material and is used by industry of oxide semi-conductor and LED chip. However, the most of the gallium-containing waste resources became outflow abroad and the most of which is imported from oversea by following technical problem and low circulation rate. In this research, the recovery of high purity Gallium metal from Gallium scrap, which containing about 30% of Gallium, was investigated by using hydro-metallurgical process. As pretreatment, the Gallium scrap was pulverized and leached by strong acid such as hydro chloric acid. At the leached solution, Indium was separated as an Indium sponge by substitution reaction and then Gallium and Zinc hydroxide separated and filtrated using strong alkaline solution such as sodium hydroxide by precipitation method. Also, Gallium metal and Zinc metal was recovered by electrowinning method. To make an electrolytic solution, Gallium and Zinc hydroxide was leached by strong alkaline solution. Finally, High purity Gallium metal was recovered by vacuum refining process to remove the Zinc impurity.

Tribological Failure Examples Involving Hydraulic Unit, Sensor, Computer of Anti-lock Brake System in Passenger Cars (승용차 ABS의 하이드로릭 유닛, 센서, 컴퓨터에 관련된 트라이볼로지적인 고장사례 고찰)

  • Lee, IlKwon;Han, JaeOh;Lee, JongHo;Lee, YoungSuk;Kim, ChooHa
    • Tribology and Lubricants
    • /
    • v.30 no.3
    • /
    • pp.183-188
    • /
    • 2014
  • In this paper, we present our analysis of tribological failure examples for an anti-lock brake system(ABS) in a car. The study range of this paper is to improve the quality of ABS system by analyzing with sensor, computer, actuator and oil lines. In the first example, the brake leak from hydraulic supply line in a caliper on the rear left side of the ABS hydraulic modulator. This produces the sponge phenomenon, where the car does not brake even when the driver operates the brake pedal. The hydraulic unit operating ABS is actuator that play role regulating drive condition according with the oil pressure supplied with wheel of a car. In the second example, the service man does not completely tighten the fixed bolt after repairing the car. This causes the ABS warning lamp to light up as the ABS wheel speed sensor cannot detect whether the ABS has been activated. In the third example, the ABS electronic control unit is separated from the soldered part of the inner circuit board. Consequently, the ABS fails in control because the ABS motor pump receives no-signal for the hydraulic unit. The wheel speed sensor has to large durability because of giving signal of acting condition to computer by detected the acceleration and deceleration of wheel of a car. In the fourth example, the ABS warning lamp lights up of when cracks propagate in the circuit board soldering part. The circuit of this computer is very important part for input and output the operating signal of system. Such failures can aggravate the durability of the ABS. Thus, the ABS needs to be optimized to eliminate malfunction phenomenon.