• Title/Summary/Keyword: Korean spacing error

Search Result 85, Processing Time 0.034 seconds

DTM Generation and Buildings Detection Using LIDAR Data

  • Shao, Yi-Chen;Chen, Liang-Chien
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.923-926
    • /
    • 2003
  • In this paper we propose a scheme to generate DTM and detect buildings on DSM generated from LIDAR data. Two stages are performed. The first stage is to perform object segmentation by using two morphology operations namely, flattening and H-Dome transformation. After filtering out the object points above the ground, we used the non-object points to generate DTM. The second stage is to detect buildings from the objects by analyzing differential slopes. The test data is in raster form with 1m spacing around Hsin-Chu Scientific Area in Taiwan. The mean error is -0.16m and the RMSE is 0.45m for DTM generation. The successful rate for building detection is 87.7%.

  • PDF

Liquid mist and videotape signal dropouts in gravure roll coating (Gravure롤 코팅방식에서 비산도료에 의한 비디오 신호의 dropouts)

  • 김명룡
    • Electrical & Electronic Materials
    • /
    • v.8 no.5
    • /
    • pp.633-639
    • /
    • 1995
  • Dropouts in magnetic media are a primary quality deficiency which is detrimental to magnetic signal quality and thus the major impediment to error-free recording, especially in high density digital recorders. The specific form of defects and causes found to be responsible for signal dropouts occurring in magnetic tape were studied. Dropout occurred when the RF signal falls to low level due to the various types of surface defects. However, the fall in the level of the RF signal in gravure roll coated tapes was most often caused by foreign particles adhering to the magnetic tape. It was also shown from the present study that scattered particles trapped under the tape surface or put on the top can lift it as it crosses the head, creating a spherical tent shaped defect and causing a temporary signal drop. Dropout producing substances were identified through optical and microchemical analyses. The results were correlated with measured electrical signal losses combined with analytical microscopy to clarify source identification of defects.

  • PDF

Self-Calibration for Direction Finding in Multi-Baseline Interferometer System (멀티베이스라인 인터페로미터 시스템에서의 자체 교정 방향 탐지 방법)

  • Kim, Ji-Tae;Kim, Young-Soo;Kang, Jong-Jin;Lee, Duk-Yung;Roh, Ji-Hyun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.4
    • /
    • pp.433-442
    • /
    • 2010
  • In this paper, self-calibration algorithm based on covariance matrix is proposed for compensating amplitude/phase mismatch in multi-baseline interferometer direction finding system. The proposed method is a solution to nonlinear constrained minimization problem which dramatically calibrate mismatch error using space sector concept with cost function as defined in this paper. This method, however, has a drawback that requires an estimated initial angle to determine the proper space sector. It is well known that this type of drawback is common in nonlinear optimization problem. Superior calibration capabilities achieved with this approach are illustrated by simulation experiments in comparison with interferometer algorithm for a varitiety of amplitude/phase mismatch error. Furthermore, this approach has been found to provide an exceptional calibration capabilities even in case amplitude and phase mismatch are more than 30 dB and over $5^{\circ}$, respectively, with sector spacing of less than $50^{\circ}$.

A Performance Analysis of Phase Comparison Monopulse Algorithm for Antenna Spacing and Antenna Array (안테나 간격 및 배열에 따른 위상 비교 모노펄스 알고리즘의 성능 분석)

  • Sim, Heon-Kyo;Jung, Min-A;Kim, Seong-Cheol
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.7
    • /
    • pp.1413-1419
    • /
    • 2015
  • Monopulse RADAR is the radar which detects the range of the target using a single transmitted signal. In this paper, using 9.41GHz X-band radar, the research for the phase comparison monopulse algorithm used in the marine environment is conducted. In addition, by applying the phase comparison monopulse algorithm, we calculate the RMSE for the various antenna spacings and the positions of the target. Based on that result, we compare the performance of the phase comparison monopulse algorithm in the uniform linear array with that in the non-uniform linear array. Finally, the differences in performance among the MUSIC algorithm, Bartlett method and the proposed phase comparison monopulse algorithm are analyzed.

Application and First Evaluation of the Operational RAMS Model for the Dispersion Forecast of Hazardous Chemicals - Validation of the Operational Wind Field Generation System in CARIS (유해화학물질 대기확산 예측을 위한 RAMS 기상모델의 적용 및 평가 - CARIS의 바람장 모델 검증)

  • Kim, C.H.;Na, J.G.;Park, C.J.;Park, J.H.;Im, C.S.;Yoon, E.;Kim, M.S.;Park, C.H.;Kim, Y.J.
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.5
    • /
    • pp.595-610
    • /
    • 2003
  • The statistical indexes such as RMSE (Root Mean Square Error), Mean Bias error, and IOA (Index of agreement) are used to evaluate 3 Dimensional wind and temperature fields predicted by operational meteorological model RAMS (Regional Atmospheric Meteorological System) implemented in CARIS (Chemical Accident Response Information System) for the dispersion forecast of hazardous chemicals in case of the chemical accidents in Korea. The operational atmospheric model, RAMS in CARIS are designed to use GDAPS, GTS, and AWS meteorological data obtained from KMA (Korean Meteorological Administration) for the generation of 3-dimensional initial meteorological fields. The predicted meteorological variables such as wind speed, wind direction, temperature, and precipitation amount, during 19 ∼ 23, August 2002, are extracted at the nearest grid point to the meteorological monitoring sites, and validated against the observations located over the Korean peninsula. The results show that Mean bias and Root Mean Square Error are 0.9 (m/s), 1.85 (m/s) for wind speed at 10 m above the ground, respectively, and 1.45 ($^{\circ}C$), 2.82 ($^{\circ}C$) for surface temperature. Of particular interest is the distribution of forecasting error predicted by RAMS with respect to the altitude; relatively smaller error is found in the near-surface atmosphere for wind and temperature fields, while it grows larger as the altitude increases. Overall, some of the overpredictions in comparisons with the observations are detected for wind and temperature fields, whereas relatively small errors are found in the near-surface atmosphere. This discrepancies are partly attributed to the oversimplified spacing of soil, soil contents and initial temperature fields, suggesting some improvement could probably be gained if the sub-grid scale nature of moisture and temperature fields was taken into account. However, IOA values for the wind field (0.62) as well as temperature field (0.78) is greater than the 'good' value criteria (> 0.5) implied by other studies. The good value of IOA along with relatively small wind field error in the near surface atmosphere implies that, on the basis of current meteorological data for initial fields, RAMS has good potentials to be used as a operational meteorological model in predicting the urban or local scale 3-dimensional wind fields for the dispersion forecast in association with hazardous chemical releases in Korea.

Prediction Model for Specific Cutting Energy of Pick Cutters Based on Gene Expression Programming and Particle Swarm Optimization (유전자 프로그래밍과 개체군집최적화를 이용한 픽 커터의 절삭비에너지 예측모델)

  • Hojjati, Shahabedin;Jeong, Hoyoung;Jeon, Seokwon
    • Tunnel and Underground Space
    • /
    • v.28 no.6
    • /
    • pp.651-669
    • /
    • 2018
  • This study suggests the prediction model to estimate the specific energy of a pick cutter using a gene expression programming (GEP) and particle swarm optimization (PSO). Estimating the performance of mechanical excavators is of crucial importance in early design stage of tunnelling projects, and the specific energy (SE) based approach serves as a standard performance prediction procedure that is applicable to all excavation machines. The purpose of this research, is to investigate the relationship between UCS and BTS, penetration depth, cut spacing, and SE. A total of 46 full-scale linear cutting test results using pick cutters and different values of depth of cut and cut spacing on various rock types was collected from the previous study for the analysis. The Mean Squared Error (MSE) associated with the conventional Multiple Linear Regression (MLR) method is more than two times larger than the MSE generated by GEP-PSO algorithm. The $R^2$ value associated with the GEP-PSO algorithm, is about 0.13 higher than the $R^2$ associated with MLR.

Methodology for Determining RSE Spacing for Vehicle-Infrastructure Integration(VII) Based Traffic Information System (Focused on Uninterrupted Traffic Flow) (차량-인프라 연계(VII) 기반 교통정보시스템의 RSE 설치간격 결정 방법론 (연속류를 중심으로))

  • Park, Jun-Hyeong;O, Cheol;Im, Hui-Seop;Gang, Gyeong-Pyo
    • Journal of Korean Society of Transportation
    • /
    • v.27 no.6
    • /
    • pp.29-44
    • /
    • 2009
  • A variety of research efforts, using advanced wireless communication technologies, have been made to develop more reliable traffic information system. This study presents a novel decentralized traffic information system based on vehicle infrastructure integration (VII). A major objective of this study was also to devise a methodology for determining appropriate spacing of roadside equipment (RSE) to fully exploit the benefits of the proposed VII-based traffic information system. Evaluation of travel time estimation accuracy was conducted with various RSE spacings and the market penetration rates of equipped vehicle. A microscopic traffic simulator, VISSIM, was used to obtain individual vehicle travel information for the evaluation. In addition, the ANOVA tests were conducted to draw statistically significant results of simulation analyses in determining the RSE spacing. It is expected that the proposed methodology will be a valuable precursor to implementing capability-enhanced next generation traffic information systems under the forthcoming ubiquitous transportation environment.

Investigation of Performance Limitations of SCM/WDM Systems Using Optical DSB Modulation and 16 QAM Signals (광 이중 측파대 변조 방식과 16 QAM 신호를 이용한 부반송파/파장 분할 다중화 시스템의 성능 분석에 대한 연구)

  • Kim, Kyoung-Soo;Lee, Jae-Hoon;Jeong, Ji-Chai
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.1
    • /
    • pp.67-74
    • /
    • 2009
  • In this paper, we investigate the performance limitations of SubCarrier Multiplexed(SCM) WDM systems using optical Double-Side Band(DSB) modulated 16 QAM signals. The Bit-Error Rate(BER) performance is evaluated under various optical transmission links including the effects of the dispersion and fiber nonlinearities such as SPM(Self-Phase Modulation) and XPM(cross-phase modulation). After simulation of SCM-WDM systems, the dominant factors determining the entire system performance are appeared to be the nonlinearity of MZ(Mach-Zehnder) modulator and the SCM channel spacing. The BER performance of subcarrier channels in the higher frequencies was degraded with the large dispersion effect only, however, the performance was improved a little with a combined effect of fiber dispersion and nonlinear effect when the hish fiber launching power was applied.

Predicting Soil Chemical Properties with Regression Rules from Visible-near Infrared Reflectance Spectroscopy

  • Hong, Suk Young;Lee, Kyungdo;Minasny, Budiman;Kim, Yihyun;Hyun, Byung Keun
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.47 no.5
    • /
    • pp.319-323
    • /
    • 2014
  • This study investigates the prediction of soil chemical properties (organic matter (OM), pH, Ca, Mg, K, Na, total acidity, cation exchange capacity (CEC)) on 688 Korean soil samples using the visible-near infrared reflectance (VIS-NIR) spectroscopy. Reflectance from the visible to near-infrared spectrum (350 to 2500 nm) was acquired using the ASD Field Spec Pro. A total of 688 soil samples from 168 soil profiles were collected from 2009 to 2011. The spectra were resampled to 10 nm spacing and converted to the 1st derivative of absorbance (log (1/R)), which was used for predicting soil chemical properties. Principal components analysis (PCA), partial least squares regression (PLSR) and regression rules model (Cubist) were applied to predict soil chemical properties. The regression rules model (Cubist) showed the best results among these, with lower error on the calibration data. For quantitatively determining OM, total acidity, CEC, a VIS-NIR spectroscopy could be used as a routine method if the estimation quality is more improved.

Dosimetric Effect on Selectable Optimization Parameters of Volumatric Modulated Arc Therapy (선택적 최적화 변수(Selectable Optimization Parameters)에 따른 부피적조절회전방사선치료(VMAT)의 선량학적 영향)

  • Jung, Jae-Yong;Shin, Yong-Joo;Sohn, Seung-Chang;Kim, Yeon-Rae;Min, Jung-Wan;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.23 no.1
    • /
    • pp.15-25
    • /
    • 2012
  • The aim of this study is to evaluate plan quality and dose accuracy for Volumetric Modulated Arc Therapy (VMAT) on the TG-119 and is to investigate the effects on variation of the selectable optimization parameters of VMAT. VMAT treatment planning was implemented on a Varian iX linear accelerator with ARIA record and verify system (Varian Mecical System Palo Alto, CA) and Oncentra MasterPlan treatment planning system (Nucletron BV, Veenendaal, Netherlands). Plan quality and dosimetric accuracy were evaluated by effect of varying a number of arc, gantry spacing and delivery time for the test geometries provided in TG-119. Plan quality for the target and OAR was evaluated by the mean value and the standard deviation of the Dose Volume Histograms (DVHs). The ionization chamber and $Delta^{4PT}$ bi-planar diode array were used for the dose evaluation. For treatment planning evaluation, all structure sets closed to the goals in the case of single arc, except for the C-shape (hard), and all structure sets achieved the goals in the case of dual arc, except for C-shape (hard). For the variation of a number of arc, the simple structure such as a prostate did not have the difference between single arc and dual arc, whereas the complex structure such as a head and neck showed a superior result in the case of dual arc. The dose distribution with gantry spacing of $4^{\circ}$ was shown better plan quality than the gantry spacing of $6^{\circ}$, but was similar results compared with gantry spacing of $2^{\circ}$. For the verification of dose accuracy with single arc and dual arc, the mean value of a relative error between measured and calculated value were within 3% and 4% for point dose and confidence limit values, respectively. For the verification on dose accuracy with the gantry intervals of $2^{\circ}$, $4^{\circ}$ and $6^{\circ}$, the mean values of relative error were within 3% and 5% for point dose and confidence limit values, respectively. In the verification of dose distribution with $Delta^{4PT}$ bi-planar diode array, gamma passing rate was $98.72{\pm}1.52%$ and $98.3{\pm}1.5%$ for single arc and dual arc, respectively. The confidence limit values were within 4%. The smaller the gantry spacing, the more accuracy results were shown. In this study, we performed the VMAT QA based on TG-119 procedure, and demonstrated that all structure sets were satisfied with acceptance criteria. And also, the results for the selective optimization variables informed the importance of selection for the suitable variables according to the clinical cases.