• 제목/요약/키워드: Korean porcelain

검색결과 889건 처리시간 0.027초

2종의 측색기에 의한 도재 색조 재현의 정확성 비교 (Comparison on accuracy of porcelain color reproducibility using two colorimeters)

  • 이태일;안진수;김영수;신상완
    • 대한치과보철학회지
    • /
    • 제47권3호
    • /
    • pp.348-355
    • /
    • 2009
  • 연구 목적: ShadeEye-Ncc dental chroma meter (Shofu Inc., Kyoto, Japan)와 Shadepilot$^{TM}$ system (Degudent Inc., Hanau, Germany)의 도재색조 재현의 정확성을 비교연구하여 보고자 함이다. 연구 재료 및 방법: ShadeEye-Ncc dental chroma meter와 Shadepilot$^{TM}$ system을 사용하여 Vitapan 3D Master shade guide의 2M2와 3M2 shade tap.을 측색하고, 이 자료를 통하여 shade guide tap. 형태로 도재시편을 제작한다. 시편제작 시 사용하는 porcelain system은 ShadeEye-Ncc dental chroma meter는 Vintage Halo Porcelain system을, Shadepilot$^{TM}$ system은 VitaOmega900 Porcelain system을 사용한다. 모델인 shade tap.과 제작된 도재시편을 spectrophotometer로 측색하고, 그 결과를 토대로하여 ${\Delta}E$를 계산하여, 두 측색기의 정확성을 비교검증하였다. 결과: 1. Shadepilot$^{TM}$ system이 ShadeEye-Ncc dental chroma meter에 비하여 더 적합한 도재색조 재현성을 나타내었다 (P <.05). 2. 모델인 Shade tap.의 shade에 따라서 도재색조 재현성에 차이를 나타내었다. 2M2 shade tap.에 비하여 3M2 shade tap.에서 더 적합한 도재색조 재현성을 나타내었다 (P <.05). 3. 두 측색기 모두에서 제작된 도재시편의 ${\Delta}E$가 평균4.44-6.14로 육안으로 구분 가능한 정도의 색조차이를 보였다. 결론: Shadepilot$^{TM}$ system이 비교적 더 정확한 도재색조 재현성을 나타낸다고 할 수 있으며, ShadeEye-Ncc dental chroma meter를 사용할 때는 치아 전체의 여러부분에서 측색을 하여 정확성을 높이는 것이 필요하리라 생각된다.

도재용착주조관용 Co-Cr합금의 주조성 및 결합강도 관찰 (Observation of the Castability and Bonding Strength of a Co-Cr alloy for Porcelain Fused to Metal Crown)

  • 정인성;김치영;김갑진
    • 대한치과기공학회지
    • /
    • 제35권2호
    • /
    • pp.105-112
    • /
    • 2013
  • Purpose: This study was to analyze the castability, surface oxide characteristic of Co-Cr alloy for porcelain fused to metal crown and the bonding strength of porcelain fused to metal crown. Co-Cr and Ni-Cr alloy for porcelain fused to metal crown was used for tests of the castability and surface oxide state and shear bonding strength by various porcelain. The aim of this study was to suggest the differences of result according to Co-Cr and Ni-Cr alloy. Methods: The kinds of alloy as test specimen was Co-Cr and Ni-Cr alloy. The castability index on the alloy specimens. The surfaces of two alloys were analyzed by SEM and EDX in order to observe oxide characteristic. And the shear test was performed by MTS. Results: The castability index of Co-Cr alloy was 96.8% and Ni-Cr alloy was 94.4%. The strongest bonding strength of Co-Cr alloy was shown 67.37 MPa. Conclusion: The shear bonding strength between Co-Cr alloy and EX3 porcelain was the strongest comparing with others. And all of each alloy was indicated as same level about the castability.

도재용착용 비귀금속 합금(Co-Cr)과 세라믹의 소성술식에 따른 전단결합강도 분석 (An analysis of shear bond strength of Co-Cr alloy of porcelain fused to metal and ceramic)

  • 임중재
    • 대한치과기공학회지
    • /
    • 제39권3호
    • /
    • pp.153-159
    • /
    • 2017
  • Purpose: In this study, a corresponding porcelain coating material was applied to dental Co-Cr metal among PFM. Methods: The bonding strength of the fired specimens was measured by a three-point flexural rigidity test. SEM/EDS was used to observe the surface component of specimens. Results: First, All groups were higher than the minimum bonding strength of 25 MPa specified in ISO 9693 for dental metal-ceramics specimens. Second, The bonding strength of control group(WO) is 44.64 MPa. Experimental group DM was 35.45 MPa and DP was 31.82 MPa(P<0.05). Tukey's HSD tests results have shown that the bonding strength in control group(WO) is higher than that of experimental group(DM, DP). Third, In the case of metal - porcelain bonding strength, the application of opaque porcelain and firing were higher than those of the group treated with degassing process. Conclusion: The bonding strength was higher when the powder opaque porcelain was applied than the paste opaque porcelain.

도재소부용 저금함유금합금에서 도재계면의 표면거동에 미치는 미량원소 In의 영향 (Effect of In on Surface Behaviors of Porcelain-Metal Boundary in Low Gold Porcelain Alloys)

  • 남상용;이기대
    • 대한치과기공학회지
    • /
    • 제21권1호
    • /
    • pp.15-26
    • /
    • 1999
  • This study was carried out by observing to composition of oxide on the surface of dental porcelain low gold alloy with various Indium additions according to the degassing and analysing the change composition of additional elements In on diffusion behaviors of Porcelain-matal surface. The specimens used were Au-Pd-Ag alloys by small indium addition. These specimens were treated for 10min at $1000^{\circ}C$ in vacuum condition. To investigate the microsturcture of oxidized alloy surface, SEM and EDAX were used, and EPMA were used to investigate the diffusion behaviors of porcelain-metal surface. X-ray diffraction were used to observe the morphological changes in the oxidation zone. The results of this study were obtained as follows ; 1) The hardness of alloy increased with increasing amount of In addition. 2) The formation of oxidation increased with increasing In content after heat treatment. 3) Diffusion of indium elements increased with increasing In content in metal-porcelain surface after firing. 4) The oxidations of alloy surface were mainly $In_2O_3$.

  • PDF

라미네이트 도재 수복물의 연마 방법에 따른 표면 거칠기의 비교 (COMPARISON OF SURFACE ROUGHNESS OF VARIOUS LAMINATE VENEER PORCELAIN ACCORDING TO POLISHING METHODS)

  • 권영숙;이근우
    • 대한치과보철학회지
    • /
    • 제34권2호
    • /
    • pp.246-265
    • /
    • 1996
  • After adjusting glazed surface of laminate veneer porcelain by reduction in the clinical procedure, an additional polishing procedure is required to smoothen the roughened surface by reduction, as it is difficult to glaze it again in the furnace. In this study, four kinds of laminate veneer porcelain were ground with diamond points as done in the clinical procedure. The adjusted porcelain surface was polished with Durawhite stone, Ceramiste points, Exa cerapol, Porcelain polishing wheel, Diamond polishing paste. The degree of surface roughness was evaluated with SEM and profilometer at each step, The self glazed surface and the glazed surface with glazing powder were compared with the polished surface and surface roughness of four kinds of laminate veneer porcelain according to the polishing method and step were obserbed. The following results were obtained : 1. There was no difference in the average surface roughness Ra value and the surface roughness obserbed under SEM according to the polishing methods and steps used, among the four kinds of laminate veneer porcelain including Colorlogic, Exelco, Vintage, and Vitadur alpha product. 2. Due to porosities, the surface in the course of polishing by polishing instruments was rougher than the glazed surface, evaluated with a SEM. 3. Insta-Glaze diamond polishing paste has no statistical difference with self glazed group 1, although it has a lower value in average surface roughness Ra value. 4. Group 2 which was glazed with galzing powder was lowest in view of SEM, but it revealed higher surface roughness Ra value than group 1, the glazed surface and group 8, polished by diamond polishing paste, due to surface waveness. 5. Proper surface smoothness could not be in the surface roughness analysis of SEM and profilometer by Shofu laminate polishing kit composed of Diamond point, Durawhite stone and Ceramiste points. Based on the results of this study, the following conclusions can be drawn. We obtain low surface roughness than glazed surface by polishing instruments, but not perfect results clinically. In order to obtain a perfect clinical result or a surface smoothness comparable to glazed porcelain there is a need for further improvement of porcelain materials, condensa-tion techniques, polishing instruments and polishing methods. Furthermore card should be taken not to breakdown the glazed surface during the clinical and laboratory procedure.

  • PDF

수복재료에 대합되는 의치용 레진치의 마모저항성 비교 (COMPARISON OF WEAR RESISTANCE AMONG RESIN DENTURE TEETH OPPOSING VAR10US RESTORATIVE MATERIALS)

  • 이철영;정문규
    • 대한치과보철학회지
    • /
    • 제37권3호
    • /
    • pp.313-327
    • /
    • 1999
  • The aim of this study was to compare wear resistance of resin denture teeth opposing various restorative materials. The wear resistance of conventional acrylic resin teeth(Trubyte Biotone) and three high-strength resin teeth(Bioform IPN, Endura, SR-Orthosit-PE) opposing different restorative materials(gold alloys, dental porcelain, composite resin) was compared. Wear tests were conducted with a sliding-induced wear testing apparatus which applied 100,000 strokes to the specimen in a mesio-distal direction under conditions of 100 stroke/min and constant loading of 1Kgf/tooth. Wear resistance of the resin denture teeth was evaluated by the following criteria : 1) wear depth, 2) weight loss, and 3) SEM observation. Results were as follows. 1. When opposed to gold alloys and composite resin, high-strength resin teeth showed superior wear resistance compared to acrylic resin teeth. But, in cases opposing dental porcelain, differences between the wear of the high-strength and acrylic resin teeth were not statistically significant (p<0.05). 2. When comparing wear resistance among high-strength resin teeth, opposing gold alloys, Endura was slightly more resistant and while in cases opposing dental porcelain, SR-Orthosit-PE was showed to be slightly resistant(p<0.05). 3. The wear of high-strength resin teeth was greater by 5 to 7 times when opposing porcelain and 2 to 3 times when opposing composite resin compared to gold alloys(p<0.05). 4. SEM observations of the wear surface showed that wear of resin teeth opposing gold alloys is a fatigue type of wear and wear of resin teeth opposing dental porcelain is fatigue and abrasion type of wear. Trubyte Biotone showed more severe fatigue type of wear than high-strength resin teeth. In conclusion, the use of dental porcelain should seriously be considered as restorative material in cases opposing resin denture teeth and improvement seems to be needed on resin teeth in the areas of wear resistance.

  • PDF

도재 수리용 레진의 색안정성에 관한 연구 (A STUDY ON THE COLOR STABILITY OF PORCELAIN REPAIR RESINS)

  • 김난영;진태호
    • 대한치과보철학회지
    • /
    • 제42권2호
    • /
    • pp.133-141
    • /
    • 2004
  • Statement of problem : Porcelain restorations are widely used in restorative dentistry with a high degree of general success. However, porcelain is brittle and may fracture intraorally. Sometimes a repair may be attempted using composite resin and bonding system available. Color stability of porcelain repair resins affects esthetics and prognosis of prosthesis, so that provides important criteria for the choice of porcelain repair resins. Purpose : The purpose of this study was to investigate the color stability of composite resins used widely as porcelain repair system. Materials and method : Composite resins used for this study were Carisma(Kulzer, Germany), Tetric ceram(Ivoclar, Liechtenstein), Filtek Z250(3M, USA), and Arabesk Top(VOCO, Germany). Thirty disc-shaped specimens($10{\times}2mm$) were fabricated from each composite resin. Color changes of specimens after treatment using thermocycling system(KD-TCS30, Kwang-duk F.A. Korea) and after immersion in methylene blue(0.05% by Wt) were measured with colorimeter(Model Tc-6Fx, Tokyo Denshoku Co.) and obtained data were analyzed. Results and Conclusion: The results obtained from this study were as fo11ows. 1. The color change of Filtek Z250 was lesser than those of Tetric ceram and Arabesk Top after thermocycling (12000 times). 2. All of the composite resins in this study showed increase of color change according to increase of thermocycling frequency. 3. After treatment with methylene blue, the color change of Arabesk Top was greater than those of Carisma and Tetric ceram, and Tetric ceram was more stable than others.