• Title/Summary/Keyword: Korean industrial standards(KS)

Search Result 137, Processing Time 0.021 seconds

Properties of Eco-friendly Artificial Stone according to the mixing ratio of Geopolymer-based recycled Aggregate (지오폴리머 기반 순환골재 혼입율에 따른 친환경성 인조석재의 특성)

  • Kyung, Seok-Hyun;Choi, Byung-Cheol;Kang, Yeon-Woo;Lee, Sang-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.06a
    • /
    • pp.126-127
    • /
    • 2020
  • Recently, as interest in environmental issues increases, minimizing carbon dioxide generated during cement manufacturing is a problem to be solved. In order to solve such a problem, it is required to use an industrial by-product of recycled aggregate, blast furnace slag, and circulating fluidized bed boiler fly ash to replace it on the basis of geopolymer(=cementless). This study examines the characteristics of eco-friendly artificial stone according to the mixing ratio of geopolymer-based recycled aggregate. As a result of the experiment, when the addition rate of the alkali stimulant was 15% and the mixing ratio of the circulating aggregate was 70%, the flexural strength and compressive strength were the highest. Density and water absorption decreased as density of circulating aggregates increased and water absorption increased. However, when the mixing ratio of the circulating aggregate exceeded 70%, the flexural strength and compressive strength decreased. Therefore, in order to obtain strengths meeting the KS standards, the mixing ratio of recycled aggregate was set to 70%, and artificial stone was manufactured using industrial by-products.

  • PDF

Performance Evaluation of Concrete Bench Flume Using Industrial by Products (산업부산물을 이용한 콘크리트 벤치플룸의 성능평가)

  • Jae-Ho Jung
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.11 no.3
    • /
    • pp.276-281
    • /
    • 2023
  • Water pipes manufactured using existing Portland cement suffer from the problem of rapid deterioration and reduced durability due to the hydration product of cement being vulnerable to acids. Therefore, in this study, water pipes were manufactured using slag and fly ash, which are industrial by-products from various industries, and their characteristics were analyzed. As a result of the experiment, slump in unhardened concrete tended to increase due to the ball bearing action of fly ash, and the amount of air was reduced due to unburned coal, indicating that measures for frost resistance were needed. In addition, the initial strength of the compressive strength was increased through steam curing, and the results were equal to or better than OPC when mixing more than 50 % of slag. The acid resistance results showed that the mass reduction rate was less than 5 %, showing excellent durability performance, and the bending failure load of the water pipe also exceeded the KS standards, so it is judged to be commercializable.

Consideration of a LED Luminaire Standard for Naval Vessels (함정용 LED 조명기구의 표준화 방안)

  • Kim, Il-Kwon;Cho, Hyang-Eun;Kil, Gyung-Suk;Kwon, Hyuk-Sang;Cho, Heung-Gi
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2011.06a
    • /
    • pp.182-182
    • /
    • 2011
  • This paper dealt with a design guide of LED luminaire standard for naval vessels. Several standards such as Korean Industrial Standard (KS), Korea Defence Standard (KDS) and US Military Standard (MIL) were compared in terms of safety and performance of lighting fixtures. The electrical and optical characteristics of the FL fixtures were experimentally analyzed to acquire design rules for LED luminaires. Based on the study results, we proposed the concept of a LED luminaire standard.

  • PDF

Empirical Evaluation of Optimal User-Centered LED Lighting Environments in Residential Bathrooms

  • Lee, Jeongmin;Choi, Kyungah;Suk, Hyeon-Jeong
    • Science of Emotion and Sensibility
    • /
    • v.16 no.3
    • /
    • pp.305-310
    • /
    • 2013
  • This user-centered research aims to empirically evaluate color temperature (K) and illuminance (lx) of residential bathroom lightings to determine the most optimal lighting conditions for productive task performance as well as for satisfying users' emotional needs. Using 3 LED lighting fixtures, 4 types of lighting contexts were investigated; main lighting, task lighting, shower lighting, and bath lighting. Two lightings were installed parallel to the vertical edges of the main bathroom mirror to be used as main and task lighting, while another fixture was installed above the bathtub to be used for shower and bathing. For each lighting context, subjects (N=54) were instructed to perform a few tasks during which time the users were exposed to different lighting conditions with color temperature ranging from 2700 K ~ 6500 K and illuminance ranging from 100 lx ~ 700 lx. Upon completing the given tasks, subjects were asked to evaluate the lighting conditions and their applicability for performing the given tasks. Based on the user evaluations, the most optimal lighting conditions for the different lighting scenarios are as follow: 1) 3500 K ~ 4300 K and 150 lx for main lighting, 2) 3500 K ~ 4300 K and 500 lx ~ 700 lx for task lighting, and 3) 2700 K ~ 3500 K and 100 lx ~ 150 lx for shower/bath lighting. These results can be used to adjust the lighting standards suggested by KS, as well as be utilized by both engineers and designers in designing new types of user-centered bathroom lightings.

  • PDF

Primary and Ultimate Biodegradation of Dishwashing Detergents (주방용세제의 일차적 생분해도 및 최종적 생분해도)

  • Kim, Mann-Young;Choi, Ung-Su;Kim, Jae-Yong;Kim, Kwang-Ryul
    • Applied Chemistry for Engineering
    • /
    • v.4 no.3
    • /
    • pp.558-563
    • /
    • 1993
  • To reveal the effect of synthetic detergent on the water pollution as a preliminary step, we measured the primary biodegradation and ultimate biodegradation with three kinds of dishwashing detergents being sold at market. Consequently, the primary biodegradation of above mentioned samples were suited to Korean Standards. Above all, the goods that has fast primary biodegradation shows the tendency to fast ultimate biodegradation.

  • PDF

A Study on the Standard Criteria of Solid Particle Separation Test for Marine Centrifugal Purifier (선박용 정유기 고형분 분리 성능시험 규격기준에 관한 연구)

  • Jeong, Sang-Hu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.8
    • /
    • pp.1028-1034
    • /
    • 2007
  • In order to establish a criteria of solid particle separation performance test on marine centrifugal purifier at factory acceptance test, an investigation had been done on criteria of test standards, regulations and test specifications of purifier manufactures. KS V 7836, fuel oil and lubricating oil purifiers for marine use-centrifugal type, the criteria of solid particle separation is studied in the point of reality, restricts and analysis method. It is proposed that a reasonable criteria and analysis method should be adopted, and the current criteria shall be revised to adequate levels considering reasonable basis and industrial technology levels. Also, the test analysis conceptions, separation efficiency method and particle size restriction method, are reviewed to fulfil separation performance test for marine centrifugal purifiers.

An Experimental Study on Precision Improvement of Chloride Ion Estimation of Hardened Concrete with Method of Sample Preparation (전처리 방법에 따른 경화콘크리트 전염화물량 측정의 정밀도 향상을 위한 실험적 연구)

  • Kim, Young-Sun;Nam, Jeong-Soo;Kim, Young-Duck;Cho, Bong-Suk;Kim, Gyu-Yong;Kim, Moo-Han
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.557-560
    • /
    • 2006
  • Worldwide, Certification systems for standard of material and quality of product exist very variously. Korean industrial Standard (KS) is most representatively certification systems in Korea. But laboratory of korea uses often ASTM, RILEM and JIS and these standards do not get into unionization. so, Granted that experiment is same, result still can different. Therefore, this research measured chloride amount of hardened concrete using identical material and wished to improve accuracy of chloride estimation as that comparison evaluate to each examination.

  • PDF

A Study on the Prevention of Lightning Accidents According to Climate Change Response (기후변화에 따른 낙뢰사고 예방을 위한 제도 방안 연구)

  • Ju, Suk-won;Kim, Seong-Bin;Rie, Dong-Ho
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.4
    • /
    • pp.48-55
    • /
    • 2020
  • The installation of lightning protection system has recently been increasing, but the amount of damage has still been increasing. In this study, survey (interview) and field conditions were conducted to identify the installation and safety standards of the lightning protection system. it was analyzed that the safety management system is non-existent at the stage of the design, manufacturing and construction of the site lightning protection system, and that the safety inspection of the lightning protection facility is not properly managed. It has been shown that lightning protection systems, that can solve these problems, need to be re-established according to the reality so that safety inspection can be carried out in accordance with safety standards such as management of safety certification products, operation of survey institutions, design, manufacturing, and construction of safety standards at a national level.

A Study on the Applicability of Water Footprint Methodology in Korea by Analyzing Domestic Water Resources Statistics (국내 물 자원 통계자료 분석을 통한 물발자국 방법론 국내 적용 가능성 확인 연구)

  • Kim, Sun Uk;Jo, Seo Weon;Ahn, Jae Hyun;Lee, Han Woong;Yeon, Sung Mo
    • Clean Technology
    • /
    • v.24 no.2
    • /
    • pp.146-153
    • /
    • 2018
  • The water footprint is an important component of the Single Market for Green Product initiative based on the EU's Roadmap to a Resource Efficient Europe. In July 2014, the EU has established the International Standard for Water Footprint (ISO 14046) and Korea has complied with the Korean Industrial Standard (KS I ISO 14046) in April 2015. If a certification system based on the international standard (ISO 14046) is introduced, developing countries such as India and Vietnam, which are not equipped with bases, can become a trade barriers in exporting, so Korea should establish a strategy to reverse them. On the other hand, water footprints are designed to take into account local environmental impacts when compared to similar footprints (eg, carbon footprint) using LCA, so that products manufactured and manufactured in Korea will have an impact on domestic waters Should be considered. Therefore, the method of the water footprint should conform to the standard for compatibility with other countries. In order to consider the domestic water condition, it is necessary to identify suitable indicator or factor for estimating water footprint on Korea. For this purpose, this study analyzed the water footprint estimation study conducted at domestic and foreign based on international standards and through the analysis of statistical data related to domestic water resources, we confirmed the applicability of the water footprint methodology in Korea.

Characteristics of Soil Chemical Properties in Abandoned Coal Mine Forest Rehabilitation Areas in Boryeong City, Chungcheongnam-do

  • Jung, Mun Ho;Shim, Yon Sik;Kim, Yoon Su;Park, Mi Jeong;Jung, Kang Ho
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.48 no.6
    • /
    • pp.744-750
    • /
    • 2015
  • The objectives of this study were to investigate soil chemical characteristics for forest rehabilitation and suggest management in abandoned coal mine areas in Boryeong City, Chungcheongnam-do. Total study sites were seven sites, and soil properties analyzed were soil pH, total organic carbon (TOC), total-N, C/N ratio, and available $P_2O_5$ (A.v. P). Average soil pH (range) was 5.9 (4.5~7.0). Three study sites (Samgwang, Shinsung1, and Shimwon1) showed lower soil pH than standard (pH 5.6~7.3) of Korea Industrial Standards (KS) for abandoned coal mine forest rehabilitation. Average contents of TOC, and total-N were 1.5% (0.1~4.7%), and 0.10% (0.03~0.23%), respectively. Five study sites where the collapsed time was less than 10 years (Wangjashingang, Wonpoong, Samgwang, Shinsung1, and Shinsung2) showed lower TOC level than standard of KS (more than 1.2%). Wangjashingang, Wonpoong, Samgwang, and Shinsung1 showed lower level of total-N than standard of KS (more than 0.09%). C/N ratio of six study sites except Shimwon1 was out of proper range (15:1~30:1). Average A.v. P (range) was $20.7mgkg^{-1}$ (4.8~63.1), less than other abandoned coal mine fores rehabilitation areas in Mungyong City, and Hwasun-gun. TOC, total N and A.v. P increased with elapsed time from forest rehabilitation, while other soil properties did not show distinct pattern. Betula platyphylla was planted in Samkwang and Sinsung where soil pH was less than KS standard. Because the growth of Betula platyphylla can be limited in acid soil, it is necessary to neutralize soil pH to proper level with some soil amendment such as lime or shell of oyster. Furthermore, TOC, total-N and A.v. P in early stage of forest rehabilitation showed lower level than proper to vegetation growth. Therefore it needs continuous monitoring of soil characteristics and fertilization for vegetation growth and influx from surrounding forest in early stage of rehabilitation.