• Title/Summary/Keyword: Korean inclination

Search Result 1,592, Processing Time 0.022 seconds

A Study on the Design Applicability of Soil Nailing Using Limit Equilibrium Analysis and Finite Element Model (한계평형 및 FEM 해석을 통한 Soil Nailing의 설계 적용성에 관한 연구)

  • Kim, Won-Cheul;Chun, Byung-Sik;Yoon, Chang-Ki;Park, Shin-Young
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2004.03b
    • /
    • pp.301-310
    • /
    • 2004
  • The several computer programs for the design of soil nailed wall are often used in Korea. However, these programs have been used without and practical justification. Therefore, in order to evaluate the applicability of these programs for the design of soil nailing, these computer results were analyzed and compared with one another. The performance evaluations by the available programs, such as SNAILZ, TALREN97, SLOPE/W STABL6, and NAILMI6, were applied and the applied data were from 6 case history(21 section). The estimated factors of safety with available programs were compared with observed horizontal deformation from the field. This study showed that the program SNAILZ is most adequate tool for the design of soil nailed wall. Also, The finite element program SOILSTRUCT was applied for the analysis of nail inclination effect in soil nailed wall. The program SOILSTRUCT showed that the most optimal inclination of nail was $20^{\circ}$. However, the effect of nail inclination on the wall deformation was negligible. Also, the tension force of the nail were increased as the nail inclination increased, and the tension force of the nail increased as the depth increased, except the deepest nail. Therefore, the larger diameter nail should be considered if the inclination of nail is steeper than the suggested range, and the deeper nails should have the larger diameters than those of shallower nails except for the deepest one.

  • PDF

Behavior Characteristics of Batter Piles by Model Test (모형실험에 의한 경사말뚝의 거동 특성)

  • 권오균;이활;석정우
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.8
    • /
    • pp.59-66
    • /
    • 2004
  • In this study, the behavior characteristics of vertical and batter piles were analyzed by the model tests and the numerical analyses. Model steel pipe piles with the inclination of 0$^{\circ}$, 10$^{\circ}$, 20$^{\circ}$ and 30$^{\circ}$ were driven into sands with the relative density of 79%. The static compression load tests and numerical analyses using PENTAGON 3D were performed. The bearing capacities of batter piles with inclination of 10$^{\circ}$, 20$^{\circ}$ and 30$^{\circ}$ were 111, 95, and 81% of those of vertical pile in model tests, and the results of numerical analyses were similar to those of model tests. The bearing capacities p.oposed by Petrasovits and Award (1968) were similar to those of model test in the inclination of 10$^{\circ}$, but overestimated in the inclination of 20$^{\circ}$ and 30$^{\circ}$. The skin frictions and end bearing loads were the maximum in the inclination of 10$^{\circ}$ and decreased with increasing the inclination angle.

FRACTURE STRENGTH OF THE IPS EMPRESS CROWN : THE EFFECTS OF INCISAL REDUCTION AND AXIAL INCLINATION ON UPPER CANINE (IPS Empress 도재관의 파절강도 : 상악 견치에서 절단연 삭제량과 축면 경사도에 따른 영향)

  • Shin Dong-Kuk;Kang Han-Joong;Park Yong-Suck;Park Kwang-Soo;Dong Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.1
    • /
    • pp.30-40
    • /
    • 2005
  • Purpose. The purpose of this study was to compare the fracture strength of the IPS Empress ceramic crown according to the incisal reduction (2.0mm, 2.5mm, 3.0mm) and axial inclination ($4^{\circ}$, $8^{\circ}$, $12^{\circ}$) of the upper canine. Material and methods. After 10 metal dies were made for each group, the IPS Empress ceramic crowns were fabricated and each crown was cemented on each metal die with resin cement. The cemented crowns mounted on the testing jig were inclined 30 degrees and the universal testing machine was used to measure the fracture strength. Results. 1. The fracture strength of the ceramic crown with 3.0mm depth and $12^{\circ}$ inclination was the highest (839N) Crowns of 2.0mm depth and $12^{\circ}$ inclination had the lowest strength (559N). 2. There was no significant difference in the fracture strength by axial inclination in the same incisal reduction group. 3. The fracture mode of the crowns was similar. Most of fracture lines began at the loading area and extended through proximal surface perpendicular to the margin irrespective of incisal reduction.

Correlation between the Inclinations of the Incisors and Lips in Mixed Dentition (혼합치열기 아동의 전치 경사도와 입술 경사도 사이의 상관관계)

  • Oh, Sungdong;Lee, Jewoo;Kim, Jinyoung;Ra, Jiyoung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.45 no.1
    • /
    • pp.21-31
    • /
    • 2018
  • This study aimed to investigate the correlation between the inclinations of the incisors and lips in mixed dentition aged 7 - 11 years. Lateral cephalometric radiographs of 353 children were analyzed to measure the upper incisor inclination, lower incisor inclination, lower-nasolabial angle, and mentolabial angle in relation to the skeletal malocclusion classification. The measurements were then assessed using the Kruskal-Wallis test, Pearson correlation, and multiple regression analysis. There were significant negative correlations between the inclination of the upper incisors and lower-nasolabial angle in all classes of skeletal malocclusion. There was a negative correlation between the inclination of the lower incisors and mentolabial angle; however, class II malocclusion had a significant positive correlation. This study identified the factors that affect lip inclination and verified their associations.

Comparison of inclination and vertical changes between single-wire and double-wire retraction techniques in lingual orthodontics

  • Hung, Bui Quang;Hong, Mihee;Yu, Wonjae;Kyung, Hee-Moon
    • The korean journal of orthodontics
    • /
    • v.50 no.1
    • /
    • pp.26-32
    • /
    • 2020
  • Objective: The Heat Induction Typodont System (HITS), used in some recent studies, has a distinct advantage over previous tooth movement simulation methods. This study aimed to compare inclination and vertical changes between the single-wire and double-wire techniques during en masse retraction with different lengths of lever arms in lingual orthodontics using an upgraded version of the HITS. Methods: Duet lingual brackets, which have two main slots, were used in this study. Forty samples were divided into four groups according to the length of the lever arm (3-mm or 6-mm hook) and the retraction wire (single-wire or double-wire). Four millimeters of en masse retraction was performed using lingual appliances. Thereafter, 3-dimensional-scanned images of the typodont were analyzed to measure inclination and vertical changes of the anterior teeth. Results: Incisor inclination presented more changes in the single-wire groups than in the double-wire groups. However, canine inclination did not differ between these groups. Regarding vertical changes, only the lateral incisors in the single-wire groups presented significantly larger values than did those in the double-wire groups. Combining the effect of hook lengths, among the four groups, the single-wire group with the 3-mm hook had the highest value, while the double-wire group with the 6-mm hook showed the least decrease in crown inclination and extrusion. Conclusions: The double-wire technique with an extended lever arm provided advantages over the single-wire technique with the same lever arm length in preventing torque loss and extrusion of the anterior teeth during en masse retraction in lingual orthodontics.

Effect of labiolingual inclination of a maxillary central incisor and surrounding alveolar bone loss on periodontal stress: A finite element analysis

  • Choi, Sung-Hwan;Kim, Young-Hoon;Lee, Kee-Joon;Hwang, Chung-Ju
    • The korean journal of orthodontics
    • /
    • v.46 no.3
    • /
    • pp.155-162
    • /
    • 2016
  • Objective: The aim of this study was to investigate whether labial tooth inclination and alveolar bone loss affect the moment per unit of force ($M_t/F$) in controlled tipping and consequent stresses on the periodontal ligament (PDL). Methods: Three-dimensional models (n = 20) of maxillary central incisors were created with different labial inclinations ($5^{\circ}$, $10^{\circ}$, $15^{\circ}$, and $20^{\circ}$) and different amounts of alveolar bone loss (0, 2, 4, and 6 mm). The $M_t/F$ necessary for controlled tipping ($M_t/F_{cont}$) and the principal stresses on the PDL were calculated for each model separately in a finite element analysis. Results: As labial inclination increased, $M_t/F_{cont}$ and the length of the moment arm decreased. In contrast, increased alveolar bone loss caused increases in $M_t/F_{cont}$ and the length of the moment arm. When $M_t/F$ was near $M_t/F_{cont}$, increases in Mt/F caused compressive stresses to move from a predominantly labial apical region to a palatal apical position, and tensile stresses in the labial area moved from a cervical position to a mid-root position. Although controlled tipping was applied to the incisors, increases in alveolar bone loss and labial tooth inclination caused increases in maximum compressive and tensile stresses at the root apices. Conclusions: Increases in alveolar bone loss and labial tooth inclination caused increases in stresses that might cause root resorption at the root apex, despite the application of controlled tipping to the incisors.

Flow Characteristics around Underwater Triangular Structure with Different Inclination (경사도가 다른 수중 삼각형상구조물 주위의 유동특성)

  • Choe, Sang-Bom;Cho, Dae-Hwan
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.20 no.2
    • /
    • pp.241-246
    • /
    • 2014
  • The purpose of this study is to investigate the flow characteristics around underwater triangular structure with various inclination and Reynolds number. A flow fields around the triangular structure model were measured by visualization method and PIV in the circulating water channel. The result of the experiment is where the triangular structure that has a inclination of $45^{\circ}$ and the reynolds number at $Re=2.9{\times}10^3$ showed rising velocity component to 2.7 times of the structure height. When the reynolds number is steady and when the inclination is greater the descending velocity component of the structure's rears current form is greatly shown and for the areas where it's more than y/hs=1.75 has a change in the angle of inclination but it doesn't give a great effect to it.

An Experimental study on the gap of movement by the hinge articulator (단순교합기에 의한 하악운동의 오차에 대한 실험적 연구)

  • Moon, Hee-Kyung
    • Journal of Technologic Dentistry
    • /
    • v.25 no.1
    • /
    • pp.111-118
    • /
    • 2003
  • I measured the movement range on the hinge articulator and the movement range in an oral. And then I studied to analyze the gap. I got wax records by the movement on the hinge articulator, the movement in an oral and the movement on the hand articulating. I measured the distance of the cusp tips that are close to the mesial direction and the distal direction, the buccal direction and the lingual direction then I compared gaps. As I saw results on data, I knew that the hinge articulator represented the range of mandibular movement restrictively. I could find the decisive contradiction that the sliding movement finished on the hinge articulator although it did not finish in an oral. If the sliding movement does not reappear exactly, it brings a fatal failure to the dental prosthesis. In addition it is impossible that the hinge articulator restores the movement in an oral because the lateral condyle inclination and the horizontal condyle inclination are fixed previously. Therefore dental prosthesisses were made by the hinge articulator, they will interfere with a mastication. I have obtained the following results; 1. The distance of sliding movement on the hinge articulator showed shorter than the distance of sliding movement in oral. This means the increase of cusp inclination of the dental prosthesis that was made on the hinge articulator. Therefore, when the lateral movement occurs in oral, there is a possibility to become the premature as the increase of cusp inclination. 2. The results that were impressed records in oral and impressed records on the hand articulating have many congruities. I think that the simple crown etc. that were made by the hand articulating method except the long span bridge and the free end case that can not measure the vertical dimension exactly can represent similarly the mandibular movement. 3. If we want to represent the mandibular movement similarly, we have to use the articulator that can adjust the horizontal condyle inclination and the lateral condyle inclination at least.

  • PDF

The Effect of Breast Hypertrophy on Patient Posture

  • Lapid, Oren;de Groof, E. Joline;Corion, Leonard U.M.C.;Smeulders, Mark J.C.;van der Horst, Chantal M.A.M.
    • Archives of Plastic Surgery
    • /
    • v.40 no.5
    • /
    • pp.559-563
    • /
    • 2013
  • Background One of the reasons women with macromastia chose to undergo a breast reduction is to relieve their complaints of back, neck, and shoulder pain. We hypothesized that changes in posture after surgery may be the reason for the pain relief and that patient posture may correlate with symptomatic macromastia and may serve as an objective measure for complaints. The purpose of our study was to evaluate the effect of reduction mammaplasty on the posture of women with macromastia. Methods A prospective controlled study at a university medical center. Forty-two patients that underwent breast reduction were studied before surgery and an average of 4.3 years following surgery. Thirty-seven healthy women served as controls. Standardized lateral photos were taken. The inclination angle of the back was measured. Regression analysis was performed for the inclination angle. Results Preoperatively, the mean inclination angle was 1.61 degrees ventrally; this diminished postoperatively to 0.72 degrees ventrally. This change was not significant (P-value=0.104). In the control group that angle was 0.28 degrees dorsally. Univariate regression analysis revealed that the inclination was dependent on body mass index (BMI) and having symptomatic macromastia; on multiple regression it was only dependent on BMI. Conclusions The inclination angle of the back in breast reduction candidates is significantly different from that of controls; however, this difference is small and probably does not account for the symptoms associated with macromastia. Back inclination should not be used as a surrogate "objective" measure for symptomatic macromastia.

Comparative study of glenoid version and inclination using two-dimensional images from computed tomography and three-dimensional reconstructed bone models

  • Choi, Chang-Hyuk;Kim, Hee-Chan;Kang, Daewon;Kim, Jun-Young
    • Clinics in Shoulder and Elbow
    • /
    • v.23 no.3
    • /
    • pp.119-124
    • /
    • 2020
  • Background: This study was performed to compare glenoid version and inclination measured using two-dimensional (2D) images from computed tomography (CT) scans or three-dimensional (3D) reconstructed bone models. Methods: Thirty patients who had undergone conventional CT scans were included. Two orthopedic surgeons measured glenoid version and inclination three times on 2D images from CT scans (2D measurement), and two other orthopedic surgeons performed the same measurements using 3D reconstructed bone models (3D measurement). The 3D-reconstructed bone models were acquired and measured with Mimics and 3-Matics (Materialise). Results: Mean glenoid version and inclination in 2D measurements were -1.705° and 9.08°, respectively, while those in 3D measurements were 2.635° and 7.23°. The intra-observer reliability in 2D measurements was 0.605 and 0.698, respectively, while that in 3D measurements was 0.883 and 0.892. The inter-observer reliability in 2D measurements was 0.456 and 0.374, respectively, while that in 3D measurements was 0.853 and 0.845. Conclusions: The difference between 2D and 3D measurements is not due to differences in image data but to the use of different tools. However, more consistent results were obtained in 3D measurement. Therefore, 3D measurement can be a good alternative for measuring glenoid version and inclination.