• Title/Summary/Keyword: Korean body image

Search Result 1,711, Processing Time 0.027 seconds

Early and Midterm Results of the Extracardiac Fontan Operation and the Change of Internal Diameter of the Conduit (심외도관 폰탄수술후 중단기 성적 및 심외도관의 내경의 변화)

  • 성시찬;김시호
    • Journal of Chest Surgery
    • /
    • v.35 no.3
    • /
    • pp.177-181
    • /
    • 2002
  • Background: Follow-up studies have shown that although outcomes have improved substantially over time, results of the Fontan operation and its modifications remain suboptimal. In this study, we reviewed our experience with the extracardiac conduit Fontan operation, with a focus early and midterm change of internal diameter of PTFE conduit. Material and Method: Between April 1997 and July 2000 were reviewed. Twelve patients (M:6, F:6, mean age 42.04 $\pm$ 12.43months, mean body weight 13.80$\pm$ 1.94kg) underwent extracardiac conduit Fontan operation with expanded PTFE graft. Mean cardiopulmonary bypass time was 109.7$\pm$26.99minute and mean operation time was 455$\pm$89.51minute. Intraoperative fenestration was performed in 10 patients. The aortic cross clamping was not performed in all patients. Result: There was no early deaths and no postoperative dysrhythmia. Postoperative protein losing enteropathy and prolonged pleural effusion occurred in 1(8.3%) and 4 patients(33.3%). Conduit patency was evaluated by magnetic resonance imaging studies. A 9.84$\pm$3.84% mean reduction in conduit internal diameter and there was no statistical correlation between the change of internal diameter of conduit and the postoperative duration after partial correlation analysis(r=0.019, p=0.955). Conclusion: These results demonstrate that the extracardiac conduit Fontan operation provies good early and midterm results and may reduce the prevalence of late arrhythmia. And there is no correlation between the change of internal diameter of conduit and the postoperative duration after extracardiac conduit Fontan operation with the expanded PTFE graft conduit.

Impact of the Planning CT Scan Time on the Reflection of the Lung Tumor Motion (전산화단층촬영 주사시간(Scan Time)이 폐종양운동의 재현성에 미치는 영향 분석)

  • Kim Su Ssan;Ha Sung Whan;Choi Eun Kyung;Yi Byong Yong
    • Radiation Oncology Journal
    • /
    • v.22 no.1
    • /
    • pp.55-63
    • /
    • 2004
  • Purpose : To evaluate the reflection of tumor motion according to the planning CT scan time. Material and Methods : A model of N-shape, which moved aiong the longitudinal axis during the ventilation caused by a mechanical ventilator, was produced. The model was scanned by planning CT, while setting the relative CT scan time (T: CT scan time/ventilatory period) to 0.33, 0.50, 0.67, 0.75, 1.00, 1.337, and 1.537. In addition, three patients with non-small cell lung cancer who received stereotactic radiosurgery In the Department of Radiation Oncology, Asan Medical Center from 03/19/2002 to 05/21/2002 were scanned. Slow (10 Premier, Picker, scan time 2.0 seconds per slice) and fast CT scans (Lightspeed, GE Medical Systems, with a scan time of 0.8 second per slice) were peformed for each patient. The magnitude of reflected movement of the N-shaped model was evaluated by measuring the transverse length, which reflected the movement of the declined bar of the model at each slice. For patients' scans, all CT data sets were registered using a stereotactic body frame scale with the gross tumor volumes delineated in one CT image set. The volume and three-dimensional diameter of the gross tumor volume were measured and analyzed between the slow and fast CT scans. Results : The reflection degree of longitudinal movement of the model increased in proportion to the relative CT scan times below 1.00 7, but remained constant above 1.00 T Assuming the mean value of scanned transverse lengths with CT scan time 1.00 T to be $100\%$, CT scans with scan times of 0.33, 0.50, 0.57, and 0.75 T missed the tumor motion by 30, 27, 20, and $7.0\%$ respectively, Slow (scan time 2.0 sec) and Fast (scan time 0.8 sec) CT scans of three patients with longitudinal movement of 3, 5, and 10 mm measured by fluoroscopy revealed the increases in the diameter along the longitudinal axis Increased by 6.3, 17, and $23\%$ in the slow CT scans. Conculsion : As the relative CT scan time increased, the reflection of the respiratory tumor movement on planning CT also Increased, but remained constant with relative CT scan times above 1.00 T When setting the planning CT scan time above one respiration period (>1.00 T), only the set-up margin is needed to delineate the planning target volume. Therefore, therapeutic ratio can be increased by reducing the radiation dose delivered to normal lung tissue.

Radiographic, MRI and Histopathologic Assessment to Standardize Canine Spinal Cord Injury Model (척수손상 모델 견 표준화를 위한 방사선, 자기공명영상 및 조직 병리 평가)

  • Seong, Yun-Sang;Yun, Sung-Ho;Park, Jai-Soon;Kim, Hee-Kyung;Chang, Yong-Min;Ku, Sae-Kwang;Park, Hyun-Jeong;Jang, Kwang-Ho
    • Journal of Veterinary Clinics
    • /
    • v.27 no.5
    • /
    • pp.546-552
    • /
    • 2010
  • Previous studies could not offer available guideline to decide size of balloon and grade of injury before induction of spinal cord injury (SCI) because grade of SCI was assessed after inserting a catheter and each experimental animal were different in body size and weight as well as in species. This study was performed to provide guideline for standardized SCI model. Eight healthy adult beagle dogs that had 8 mm of spinal canal height were assigned to four groups according to the diameter of balloon and compression time: 4 mm/3hrs, 4 mm/6hrs, 4 mm/12hrs and 6 mm/3hrs group. Radiography was performed to standardize between experimental animal and balloon before selecting balloon diameter to induce SCI. Behaviors outcomes, somatosensory evoked potentials (SEPs), magnetic resonance imaging (MRI) and histopathological examination were evaluated. Behaviors outcomes and SEPs were not available to assess grade of SCI and those only indicate SCI. The damaged area was revealed clear hyperintensity on STIR image and T2WI after induction of SCI. The hyperintense area on MRI was cranially and caudally expanded with increasing of the diameter of balloon or the compression time. Well corresponded to expanding of hyperintense area on MRI, the damaged region and the numbers of caspase-3 and PARP immunoreactive cells were increased on histopathological findings. Therefore, these results will be considered fundamental data to induce standardized SCI model in experimental animal that has various weight and size.

A Microgravity for Mapping and Monitoring the Subsurface Cavities (지하 공동의 탐지와 모니터링을 위한 고정밀 중력탐사)

  • Park, Yeong-Sue;Rim, Hyoung-Rae;Lim, Mu-Taek;Koo, Sung-Bon
    • Geophysics and Geophysical Exploration
    • /
    • v.10 no.4
    • /
    • pp.383-392
    • /
    • 2007
  • Karstic features and mining-related cavities not only lead to severe restrictions in land utilizations, but also constitute serious concern about geohazard and groundwater contamination. A microgravity survey was applied for detecting, mapping and monitoring karstic cavities in the test site at Muan prepared by KIGAM. The gravity data were collected using an AutoGrav CG-3 gravimeter at about 800 stations by 5 m interval along paddy paths. The density distribution beneath the profiles was drawn by two dimensional inversion based on the minimum support stabilizing functional, which generated better focused images of density discontinuities. We also imaged three dimensional density distribution by growing body inversion with solution from Euler deconvolution as a priori information. The density image showed that the cavities were dissolved, enlarged and connected into a cavity network system, which was supported by drill hole logs. A time-lapse microgravity was executed on the road in the test site for monitoring the change of the subsurface density distribution before and after grouting. The data were adjusted for reducing the effects due to the different condition of each survey, and inverted to density distributions. They show the change of density structure during the lapsed time, which implies the effects of grouting. This case history at the Muan test site showed that the microgravity with accuracy and precision of ${\mu}Gal$ is an effective and practical tool for detecting, mapping and monitoring the subsurface cavities.

The Differentiation of Malignant and Benign Musculoskeletal Tumors by F-18 FDG PET/CT Studies - Determination of maxSUV by Analysis of ROC Curve (F-18 FDG PET/CT에서 양성과 악성 근골격 종양의 감별진단 - 수신자 판단특성곡선을 이용한 maxSUV의 절단값 결정)

  • Kong, Eun-Jung;Cho, Ihn-Ho;Chun, Kyung-Ah;Won, Kyu-Chang;Lee, Hyung-Woo;Choi, Jun-Heok;Shin, Duk-Seop
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.6
    • /
    • pp.553-560
    • /
    • 2007
  • Purpose: We evaluated the standard uptake value (SUV) of F-18 FDG at PET/CT for differentiation of benign from malignant tumor in primary musculoskeletal tumors. Materials and Methods: Forty-six tumors (11 benign and 12 malignant soft tissue tumors, 9 benign and 14 malignant bone tumors) were examined with F-18 FDG PET/CT (Discovery ST, GE) prior to tissue diagnosis. The maxSUV(maximum value of SUV) were calculated and compared between benign and malignant lesions. The lesion analysis was based on the transverse whole body image. The maxSUV with cutoff of 4.1 was used in distinguishing benign from malignant soft tissue tumor and 3.05 was used in bone tumor by ROC curve. Results: There was a statistically significant difference in maxSUV between benign (n=11; maxSUV $3.4{\pm}3.2$) and malignant (n=12; maxSUV $14.8{\pm}12.2$) lesions in soft tissue tumor (p=0.001). Between benign bone tumor (n=9; maxSUV $5.4{\pm}4.0$) and malignant bone tumor (n=14; maxSUV $7.3{\pm}3.2$), there was not a significant difference in maxSUV. The sensitivity and specificity for differentiating malignant from benign soft tissue tumor was 83% and 91%, respectively. There were four false positive malignant bone tumor cases to include fibrous dysplasia, Langerhans-cell histiocytosis (n=2) and osteoid osteoma. Also, one false positive case of malignant soft tissue tumor was nodular fasciitis. Conclusion: The maxSUV was useful for differentiation of benign from malignant lesion in primary soft tissue tumors. In bone tumor, the low maxSUV correlated well with benign lesions but high maxSUV did not always mean malignancy.

Simultaneous Removal of NO and SO2 using Microbubble and Reducing Agent (마이크로버블과 환원제를 이용한 습식 NO 및 SO2의 동시제거)

  • Song, Dong Hun;Kang, Jo Hong;Park, Hyun Sic;Song, Hojun;Chung, Yongchul G.
    • Clean Technology
    • /
    • v.27 no.4
    • /
    • pp.341-349
    • /
    • 2021
  • In combustion facilities, the nitrogen and sulfur in fossil fuels react with oxygen to generate air pollutants such as nitrogen oxides (NOX) and sulfur oxides (SOX), which are harmful to the human body and cause environmental pollution. There are regulations worldwide to reduce NOX and SOX, and various technologies are being applied to meet these regulations. There are commercialized methods to reduce NOX and SOX emissions such as selective catalytic reduction (SCR), selective non-catalytic reduction (SNCR) and wet flue gas desulfurization (WFGD), but due to the disadvantages of these methods, many studies have been conducted to simultaneously remove NOX and SOX. However, even in the NOX and SOX simultaneous removal methods, there are problems with wastewater generation due to oxidants and absorbents, costs incurred due to the use of catalysts and electrolysis to activate specific oxidants, and the harmfulness of gas oxidants themselves. Therefore, in this research, microbubbles generated in a high-pressure disperser and reducing agents were used to reduce costs and facilitate wastewater treatment in order to compensate for the shortcomings of the NOX, SOX simultaneous treatment method. It was confirmed through image processing and ESR (electron spin resonance) analysis that the disperser generates real microbubbles. NOX and SOX removal tests according to temperature were also conducted using only microbubbles. In addition, the removal efficiencies of NOX and SOX are about 75% and 99% using a reducing agent and microbubbles to reduce wastewater. When a small amount of oxidizing agent was added to this microbubble system, both NOX and SOX removal rates achieved 99% or more. Based on these findings, it is expected that this suggested method will contribute to solving the cost and environmental problems associated with the wet oxidation removal method.

Assessment of Bone Metastasis using Nuclear Medicine Imaging in Breast Cancer : Comparison between PET/CT and Bone Scan (유방암 환자에서 골전이에 대한 핵의학적 평가)

  • Cho, Dae-Hyoun;Ahn, Byeong-Cheol;Kang, Sung-Min;Seo, Ji-Hyoung;Bae, Jin-Ho;Lee, Sang-Woo;Jeong, Jin-Hyang;Yoo, Jeong-Soo;Park, Ho-Young;Lee, Jae-Tae
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.1
    • /
    • pp.30-41
    • /
    • 2007
  • Purpose: Bone metastasis in breast cancer patients are usually assessed by conventional Tc-99m methylene diphosphonate whole-body bone scan, which has a high sensitivity but a poor specificity. However, positron emission tomography with $^{18}F-2-deoxyglucose$ (FDG-PET) can offer superior spatial resolution and improved specificity. FDG-PET/CT can offer more information to assess bone metastasis than PET alone, by giving a anatomical information of non-enhanced CT image. We attempted to evaluate the usefulness of FDG-PET/CT for detecting bone metastasis in breast cancer and to compare FDG-PET/CT results with bone scan findings. Materials and Methods: The study group comprised 157 women patients (range: $28{\sim}78$ years old, $mean{\pm}SD=49.5{\pm}8.5$) with biopsy-proven breast cancer who underwent bone scan and FDG-PET/CT within 1 week interval. The final diagnosis of bone metastasis was established by histopathological findings, radiological correlation, or clinical follow-up. Bone scan was acquired over 4 hours after administration of 740 MBq Tc-99m MDP. Bone scan image was interpreted as normal, low, intermediate or high probability for osseous metastasis. FDG PET/CT was performed after 6 hours fasting. 370 MBq F-18 FDG was administered intravenously 1 hour before imaging. PET data was obtained by 3D mode and CT data, used as transmission correction database, was acquired during shallow respiration. PET images were evaluated by visual interpretation, and quantification of FDG accumulation in bone lesion was performed by maximal SUV(SUVmax) and relative SUV(SUVrel). Results: Six patients(4.4%) showed metastatic bone lesions. Four(66.6%) of 6 patients with osseous metastasis was detected by bone scan and all 6 patients(100%) were detected by PET/CT. A total of 135 bone lesions found on either FDG-PET or bone scan were consist of 108 osseous metastatic lesion and 27 benign bone lesions. Osseous metastatic lesion had higher SUVmax and SUVrel compared to benign bone lesion($4.79{\pm}3.32$ vs $1.45{\pm}0.44$, p=0.000, $3.08{\pm}2.85$ vs $0.30{\pm}0.43$, p=0.000). Among 108 osseous metastatic lesions, 76 lesions showed as abnormal uptake on bone scan, and 76 lesions also showed as increased FDG uptake on PET/CT scan. There was good agreement between FDG uptake and abnormal bone scan finding (Kendall tau-b : 0.689, p=0.000). Lesion showed increased bone tracer uptake had higher SUVmax and SUVrel compared to lesion showed no abnormal bone scan finding ($6.03{\pm}3.12$ vs $1.09{\pm}1.49$, p=0.000, $4.76{\pm}3.31$ vs $1.29{\pm}0.92$, p=0.000). The order of frequency of osseous metastatic site was vertebra, pelvis, rib, skull, sternum, scapula, femur, clavicle, and humerus. Metastatic lesion on skull had highest SUVmax and metastatic lesion on rib had highest SUVrel. Osteosclerotic metastatic lesion had lowest SUVmax and SUVrel. Conclusion: These results suggest that FDG-PET/CT is more sensitive to detect breast cancer patients with osseous metastasis. CT scan must be reviewed cautiously skeleton with bone window, because osteosclerotic metastatic lesion did not showed abnormal FDG accumulation frequently.

A Study of Influence of Filgrastim on PET/CT In Diffuse Large B cell Lymphoma (미만성 거대 B 세포 림프종 환자에서 Filgrastim 사용이 PET/CT 영상에 미치는 영향에 대한 고찰)

  • NamKoong, Hyuk;Park, Hoon-Hee;Ban, Yung-Gak;Kang, Sin-Chang;Kim, Sang-Kyoo;Lim, Han-Sang;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.17-23
    • /
    • 2009
  • Purpose: It has been known that PET/CT is very valuable in follow-up study of diffuse large B cell lymphoma (DLBCL). Generally, in DLBCL, radiotherapy and chemotherapy has been progressed, because the lesion hasn‘t been limited to one site. And, it has lead to the decrease of leukocyte like neutropenia, due to myelosuppression of chemotherapy. So, in that case, administration of Filgrastim (Granulocyte colony-stimulating factor; G-CSF) is universal. However, in short time after administration, PET/CT has limitation to offer accurate images, through the uptake of $^{18}F$-FDG is increased in the region that is activated bone marrow by hematopoietic growth. Therefore, the aim of this study is that PET/CT in a certain period of time after administration of Filgrastim is able to show normal degree of $^{18}F$-FDG uptake. Materials and Methods: 10 patients under follow-up study of diffuse large B cell lymphoma were examined in this study from January, 2007 to January, 2009 (Male: 4 persons; Female: 6 persons; The mean age: 53.8 years old; The mean weight: 57.3 Kg). Using PET/CT (Discovery STe; GE Healthcare, Milwaukee, WI, USA), whole body images were acquired in 1 hour after $^{18}F$-FDG injection. For image analysis, each ROI ($120\;mm^2$) was drawn on $C^6$ (the sixth C-spine), $L_4$ (the forth L-spine), liver, spleen, and lung, then SUV (Standard Uptake Value)s were measured. We compared with each uptake between in 1-day and 5~7 days after administration of Filgrastim at same patient, so confirmed significance about these by SPSS version 12. Results: In case of $C_6$, $L_4$, spleen, every SUV of 1 day later was remarkably higher than that of 5~7 days later, but liver and lung were similar. Also, the images acquired after 5~7 days distinct remarkably and show normal degree of $^{18}F$-FDG uptake, because uptake of bone was almost disappeared. Conclusions: In this study, each SUV was prominent difference as a period of time after Filgrastim’s administration. And Filgrastim makes concentrate uptake of $^{18}F$-FDG in bone, but, after 5~7 days, bone‘s uptake was greatly decreased. Therefore, we are able to infer a certain period of time that shows normal degree of uptake, by numerical value proven. Also, we consider that this study contribute to advanced study about the other agent like Pegfilgrastim, Lenograstim besides Filgrastim, afterwards.

  • PDF

Performance Evaluation of Siemens CTI ECAT EXACT 47 Scanner Using NEMA NU2-2001 (NEMA NU2-2001을 이용한 Siemens CTI ECAT EXACT 47 스캐너의 표준 성능 평가)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.3
    • /
    • pp.259-267
    • /
    • 2004
  • Purpose: NEMA NU2-2001 was proposed as a new standard for performance evaluation of whole body PET scanners. in this study, system performance of Siemens CTI ECAT EXACT 47 PET scanner including spatial resolution, sensitivity, scatter fraction, and count rate performance in 2D and 3D mode was evaluated using this new standard method. Methods: ECAT EXACT 47 is a BGO crystal based PET scanner and covers an axial field of view (FOV) of 16.2 cm. Retractable septa allow 2D and 3D data acquisition. All the PET data were acquired according to the NEMA NU2-2001 protocols (coincidence window: 12 ns, energy window: $250{\sim}650$ keV). For the spatial resolution measurement, F-18 point source was placed at the center of the axial FOV((a) x=0, and y=1, (b)x=0, and y=10, (c)x=70, and y=0cm) and a position one fourth of the axial FOV from the center ((a) x=0, and y=1, (b)x=0, and y=10, (c)x=10, and y=0cm). In this case, x and y are transaxial horizontal and vertical, and z is the scanner's axial direction. Images were reconstructed using FBP with ramp filter without any post processing. To measure the system sensitivity, NEMA sensitivity phantom filled with F-18 solution and surrounded by $1{\sim}5$ aluminum sleeves were scanned at the center of transaxial FOV and 10 cm offset from the center. Attenuation free values of sensitivity wire estimated by extrapolating data to the zero wall thickness. NEMA scatter phantom with length of 70 cm was filled with F-18 or C-11solution (2D: 2,900 MBq, 3D: 407 MBq), and coincidence count rates wire measured for 7 half-lives to obtain noise equivalent count rate (MECR) and scatter fraction. We confirmed that dead time loss of the last flame were below 1%. Scatter fraction was estimated by averaging the true to background (staffer+random) ratios of last 3 frames in which the fractions of random rate art negligibly small. Results: Axial and transverse resolutions at 1cm offset from the center were 0.62 and 0.66 cm (FBP in 2D and 3D), and 0.67 and 0.69 cm (FBP in 2D and 3D). Axial, transverse radial, and transverse tangential resolutions at 10cm offset from the center were 0.72 and 0.68 cm (FBP in 2D and 3D), 0.63 and 0.66 cm (FBP in 2D and 3D), and 0.72 and 0.66 cm (FBP in 2D and 3D). Sensitivity values were 708.6 (2D), 2931.3 (3D) counts/sec/MBq at the center and 728.7 (2D, 3398.2 (3D) counts/sec/MBq at 10 cm offset from the center. Scatter fractions were 0.19 (2D) and 0.49 (3D). Peak true count rate and NECR were 64.0 kcps at 40.1 kBq/mL and 49.6 kcps at 40.1 kBq/mL in 2D and 53.7 kcps at 4.76 kBq/mL and 26.4 kcps at 4.47 kBq/mL in 3D. Conclusion: Information about the performance of CTI ECAT EXACT 47 PET scanner reported in this study will be useful for the quantitative analysis of data and determination of optimal image acquisition protocols using this widely used scanner for clinical and research purposes.

A Comparative Survey on Misconception and Desire for Physique of College Women in Taegu and Fukuoka (한.일 여대생의 자기 체형 인식 및 체형 불안도에 관한 비교 연구)

  • Hong, Jin-Pyo;Choi, Bong-Soon
    • Journal of the Korean Society of Food Culture
    • /
    • v.15 no.5
    • /
    • pp.435-442
    • /
    • 2000
  • This study was carried out to investigate misconception for physique and desire for physique of college women in Taegu(412 subjects) and Fukuoka(423 subjects). The data was collected by questionnaire interview and anthropometric measurement. The results were as follows : The mean age, height, weight, and BMI of Taegu subjects were $19.9{\pm}1.2$ years old, $159.6{\pm}4.9cm,\;51.2{\pm}6.0kg\;and\;20.1{\pm}2.2$, respectively. The mean age, height , weight, and BMI of Fukuoka subjects were $18.3{\pm}0.6$ year old, $157.5{\pm}5.0cm,\;53.3{\pm}6.9kg\;and\;21.5{\pm}2.5$, respectively. The average ideal height desired by subjects in Taegu was higher than their real mean height by 5.1cm ; while the average ideal weight desired by subjects was lower than real mean weight by 2.6kg. The average ideal height desired by subjects in Fukuoka was higher than their real mean height by 3.2cm ; while the average ideal weight desired by subjects was lower than real mean weight by 5.4kg. The percentage of Taegu subjects who desired to be slender, be fatty and maintain weight were 70.1%, 7.3%, and 22.6% respectively. The percentage of Fukuoka subjects who desired to be slender, be fatty and maintain weight were 85.3%,2.6% and 12.1% respectively. The rate of misconception for the actual physique was 56.5% in Taegu subjects, and 57.2% In fukuoka subjects. The over estimation rate was higher in subjects desired for slenderness than in others. The adolescent females having a fatty body image in self-consciousness indicated that they felt high social physique anxiousness. Finally, the rate of misconception and the degree of social physique anxiousness were higher in those who had a desire for slenderness.

  • PDF