• Title/Summary/Keyword: Korean Teeth

Search Result 6,129, Processing Time 0.039 seconds

INFLUENCE OF A SODIUM HYPOCHLORITE GEL ON MICROLEAKAGE OF COMPOSITE RESIN RESTORATIONS (차아염소산 나트륨의 사용이 복합레진 수복물의 미세누출에 미치는 영향)

  • Yang, Kye-Sik;Kim, Dae-Eop;Lee, Kwang-Hee;Jeong, Young-Nam
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.1
    • /
    • pp.54-60
    • /
    • 2003
  • This study evaluated the influence of chemomechanical caries removal agent $Carisolv^{TM}$(MediTeam, Sweden) for composite resin adhesion to sound human permanent and primary dentin. The buccal/labial surfaces of 80 permanent molars and 80 primary incisors were used. Four types of adhesives and one composite resin were used; AQ Bond(Sun Medical, Japan), Clearfil SE Bond(Kuraray, Japan), Single Bond(3M, USA), Scotchbond Multi-Purpose(3M, USA) and Z100(3M, USA). One drop of $Carisolv^{TM}$(MediTeam, Sweden) was pretreated on the dentin for 0 second(control) and 60 seconds. The specimens were thermocycled for 1,000 times in baths kept 5 degrees C and 55 degrees C with a 30 seconds dwell time. Shear bond strengths were tested and the data was statistically analyzed using one-way ANOVA with subsequent post hoc Scheffe test at p<0.05. $Carisolv^{TM}$ treatment significantly decreased the shear bond strength. Shear bond strength of permanent dentin was significantly higher than that of primary dentin. Clearfil SE Bond treatment groups showed the highest shear bond strength and AQ Bond treatment groups showed the lowest shear bond strength.

  • PDF

INHIBITORY EFFECT OF Er:YAG LASER ON THE GROWTH OF STREPTOCOCCUS MUTANS (Er:YAG 레이저 조사가 Streptococcus mutans의 증식억제에 미치는 효과)

  • Song, Gwang-Chul;Lee, Chang-Seop;Lee, Sang-Ho;Lee, Nan-Young
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.1
    • /
    • pp.15-24
    • /
    • 2003
  • The purpose of this study is to investigate the sterilization effect of Er:YAG laser against the intraoral acid producing bacterium, S. mutans, by irradiating the culture solution containing S. mutans KCTC 3065 with Er:YAG laser having a $650{\mu}m$ diameter beam through the non-contact method. We obtained the following results after examining the temperature changes of the culture solution, numbers of bacterial colonies, and acid-producing ability and attaching ability on teeth by measuring the amount of extracellular polysaccharide produced by S. mutans. The number of bacterial colony was decreased in $10{\mu}l$ culture solution irradiated with laser in overall compared to the control solution. The number decreased as the irradiation intensity and pulse repetition rate were larger and as the exposure time was increased. However, it did not change significantly in $100{\mu}l$ culture solution compared to the control solution. Although the acid-producing ability of S. mutans was inhibited for a certain duration after laser irradiation in 10r1 bacterial culture solution, it did not change in $100{\mu}m$ solution compared with the control solution. The amount of extracellular polysaccharide synthesized by S. mutans was partially decreased through laser irradiation in $10{\mu}m$ culture solution but did not change in $100{\mu}m$ culture solution. Based on these findings, we concluded that Er:YAG laser has an sterilization effect on S. mutans in which we presume that the mechanism is through the heat effect rather than the mechanical effect from development of ultrasound.

  • PDF

THE CLINICAL APPLICATION OF BUCCAL ACRYLIC APPLIANCES (Buccal acrylic appliance의 임상적 적용)

  • Noh, Hong-Seok;Kim, Shin;Jeong, Tae-Sung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.34 no.2
    • /
    • pp.315-321
    • /
    • 2007
  • Removable appliance has many utilities in pediatric dentistry in the fields of space maintainance or occlusal guidance. In contrast to maxilla, many problems have occurred with mandible in using removable appliance such as deteriorated retention, inconvenience and patient's unwillingness to wear. It is probably due to adapting several retentive clasps at buccal side of the tooth, where there is actually little or no undercut especially in young children having the erupting teeth Moreover, acrylic base plate of conventional removable appliance is located at lingual parts, which leads to the conflict with alveolar crest undercut and sublingual soft tissues. Moreover, young children frequently do not follow the dentist's direction to elevate tongue properly during the impression taking process. Throughout this study, the position of clasps and acrylic baseplate was changed opposite to the traditional Hawley acrylic appliance in order to make a buccal acrylic appliance with buccal base plate and lingual clasp into primary dentition and early mixed dentition. This study was performed for the purpose of evaluating the buccal acrylic appliance in regards of patient compliance, retention and efficiency compared with traditional lingual acrylic appliance along with its merits and demerits. Buccal and lingual acrylic appliance were applied to 5 cases respectively which required space maintaining and tooth movement, and drew a comparison in relevance to patients' compliance, combination with the tongue's function and clinical effectiveness. According to this study, in every case buccal appliance was proved superior to lingual appliance in terms of retention and patients' compliance. Moreover, buccal appliance has shown to be similar to lingual appliance with respect to clinical effectiveness. Throughout this study, it was thought that, if removable appliance is to be applied to mandible, several drawbacks related to conventional lingual appliance shall be resolved. Conclusively, the buccal acrylic appliance is thought to be a good alternative in designing a mandibular appliance in young children and recommended to clinical applications.

  • PDF

AGE ESTIMATION USING PANORAMIC RADIOGRAPHS OF DEVELOPING PERMANENT TEETH (발육중인 영구치의 파노라마 방사선 사진 계측을 이용한 연령 추정)

  • Choi, Eun-Young;Choi, Nam-Ki;Kim, Seon-Mi;Yang, Kyu-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.34 no.2
    • /
    • pp.215-221
    • /
    • 2007
  • The aim of this study was to test whether metric measurements of crown length, root length and apex width during tooth development could be a better basis for correlation with age than the classical methods based on subjective estimations of various stages of tooth development. Panoramic radiographs of 120 children, aged 7 to 9 years, were collected from the department of the pediatric dentistry of Chonnam National University Hospital, Korea. The methods of Mornstad was used to estimate age. The structures measured were crown length root length and apex width in panoramic radiographic. The results were as follows : 1. In the boys, it showed higher correlation between lower 2nd molar crown length, lower 1st molar root length or lower 1st permolar apical width and age. In the girls, it showed higher correlation between lower 2nd premolar crown length, lower 2nd molar root length or lower 1st molar apical width and age. 2. With the aid of a multiple regression model, a linear relationship between some of these distances and age was shown. Boy(months) = 43.958 + lower 2nd molar crown length ${\times}$ 4.392 + lower 1st molar root length ${\times}$ 2.255 - lower 1st permolar apical width ${\times}$ 2.046, Girl(months) = 75.213 + lower 2nd premolar crown length ${\times}$ 3.910 lower 2nd molar root length ${\times}$ 2.280 - lower 1st molar apical width ${\times}$ 6.217 Age was estimated in boys and girls using the mathematic model ; the mean difference between chronological and estimated ages was $-2.1{\pm}6.8$ months for boys and $6.1{\pm}6.2$ months for girls. Therefore, it seems to be more accurate and easier than the earlier methods.

  • PDF

IN VITRO STUDY OF CARIOGENIC POTENTIAL OF INFANT CONFECTIONARIES (유아용 과자의 우식유발능에 관한 생체 외 연구)

  • Song, Ji-Hyon;Lee, Kwang-Hee;Kim, Dae-Eup;Ra, Ji-Young;Lee, Dong-Jin;An, So-Youn
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.1
    • /
    • pp.39-46
    • /
    • 2008
  • The purpose of this study was to assess the cariogenic potential of infant confectionaries. In vitro, as compaired with 10% sucrose solution and whole bovine milk. Buffering capability were determined by amount of 0.1N lactic acid consumed to titrate the 50ml specimen solutions to pH 4.0. The pH of the specimen solution inoculated by streptococcus mutans was measured by pH meter and the surface microhardness tester, before and after 48 hours incubation. The buffering capacity of infant confectionaries was higher than that of sucrose solution and lower than that of milk, and there were significant difference between infant confectionaries(p<0.05). The pH of infant confectionaries after 48 hours incubation was similar to 10% sucrose solution, and there were significant difference between infant confectionaries and milk(p<0.05). The microhardness change of primary tooth enamel of infant confectionaries group after 48 hours incubation was similar to that of 10% sucrose solution, and there were significant difference between infant confectionaries and milk(p<0.05). In conclusion, infant confectionaries seemed to have the ability to cause dental caries in primary teeth, and there were significant differences of cariogenic potential among infant confectionaries. Cooperative efforts of dentistry and manufacturers to reduce the cariogenic potential of infant confectionaries would be necessary to prevent the early childhood caries in children.

  • PDF

INFLUENCE OF SEVERAL POSTS AND IPS-EMPRESS INGOT THICKNESS ON THE FINAL SHADE OF ALL-CERAMIC CROWNS (수종의 post와 IPS-Empress Ingot 두께가 전부 도재 수복물 최종색조에 미치는 영향)

  • Bok Won-Mi;Choi Keun-Bae;Park Charn-Woon;Ahn Seung-Geun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.5
    • /
    • pp.514-523
    • /
    • 2004
  • Statement of problem: All-ceramic restorations have been advocated for superior esthetics. Various post and core systems have been used to improve the strength of damaged teeth, but it is unclear whether they affect the final shade of finished all-ceramic restorations. Purpose: The influence of different types of post and core systems on light transmission through all-ceramic crowns was assessed by spectrophotometric analysis. Also the masking effect of different thickness of ceramic ingot was evaluated. Material and Methods : Forty-five sample disks (15mm in diameter) at several thickness(1.0, 1.5, 2.0mm) and value(shade 100, 200, 300) were made in heat pressed ceramic(IPS-Empress). Background specimens simulating gold-alloy cast posts(Type III casting gold alloy), metal posts(Ni-Cr casting alloy) and ceramic posts(CosmoPost) were fabrica-ted. Resin composite(Z250, A3 shade) was used as a tooth substrate reference. For each combination, the change in color was measured with a spectrophotometer. Readings were performed for 2 conditions (1) ability of ceramic to mask the core in relation to its thickness(1.0, 1.5, or 2.0mm) ; (2) influence of post and core types on the final color of the ceramic. Data were recorded according to the CIE $L^*a^*b^*$ systems and color difference($\Delta$E) was calculated. Results: 100 shade ingot: when ceramic thickness was 1.0mm, $\Delta$E value for ceramic post larger than 1 but $\Delta$E value for metal and gold post was larger than 2. For ceramic thickness of 1.5mm, only $\Delta$E value for metal was larger than 2, and the other samples' $\Delta$E value was smaller than 2. For ceramic thickness of 2.0mm, $\Delta$E values for all specimens was smaller than 2. 200 shade ingot: when ceramic thickness was 1.0mm, $\Delta$E value for ceramic post was smaller than 1 but $\Delta$E value for metal and gold post was larger than 2. For ceramic thickness of 1.5 mm, only the $\Delta$E value for metal was larger than 2, and the other samples' $\Delta$E value was smaller than 2. For ceramic thickness of 2.0mm, $\Delta$E values for all specimens was smaller than 1. 300 shade ingot: when ceramic thickness was 1.0mm, only $\Delta$E value for metal was larger than 2 and the other samples' $\Delta$E value was smaller than 2. For ceramic thickness of 1.5mm, $\Delta$E values for all specimens was smaller than 1. For ceramic thickness of 2.0mm, $\Delta$E values for all specimens was smaller than 1. Conclusion: The final esthetic result of the IPS-Empress glass-ceramic restoration was not affected by the presence of different core materials when the thickness was more than 2.0 mm. When ceramic thickness decreases to 1.5mm, it is advised to take the substrate aspects into consideration. If the ceramic thickness is less than 1.0mm, using the tooth color matched substrate is strongly recommended.

Influence of bone loss pattern on stress distribution in bone and implant: 3D-FEA study (주변 골흡수 양상에 따른 임플란트와 골의 응력분산에 관한 유한요소 분석)

  • Lee, Jong-Hyuk;Kim, Sung-Hun;Lee, Jae-Bong;Han, Jung-Suk;Yang, Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.2
    • /
    • pp.111-121
    • /
    • 2010
  • Purpose: This 3D-FEA study was performed to investigate the influence of marginal bone loss pattern around the implant to the stress distribution. Material and methods: From the right second premolar to the right second molar of the mandible was modeled according to the CT data of a dentate patient. Teeth were removed and an implant ($\Phi\;4.0{\times}10.0mm$) was placed in the first molar area. Twelve bone models were created; Studied bone loss conditions were horizontal bone loss and vertical bone loss, assumed bone loss patterns during biologic width formation, and pathologic vertical bone loss with or without cortification. Axial, buccolingual, and oblique force was applied independently to the center of the implant crown. The Maximum von Mises stress value and stress contour was observed and von Mises stresses at the measuring points were recorded. Results: The stress distribution patterns were similar in the non-resorption and horizontal resorption models, but differed from those in the vertical resorption models. Models assuming biologic width formation showed altered stress distribution, and weak bone to implant at the implant neck area seams accelerates stress generation. In case of vertical bone resorption, contact of cortical bone to the implant may positively affect the stress distribution.

Shade comparative analysis of natural tooth measured by visual and spectrophotometric methods (육안과 분광 측정기를 이용한 자연 치아의 색조비교분석)

  • Kim, Bum-Suk;Shin, Soo-Yeon;Lee, Jong-Hyuk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.5
    • /
    • pp.443-454
    • /
    • 2008
  • Statement of problem: A clinically successful color match is one of the important factor to get an esthetic dental restoration. Dental shade guides are commonly used to evaluate tooth color in restorative procedure. But numerous reports have indicated that common shade guides do not provide sufficient spectral coverage of the natural tooth colors. To address issues associated with the shade guide, distinct avenues have been pursued objective spectrophotometric / colorimetric assessment. Purpose: This study compared the accuracy of tooth color selection of spectrophotometer with that of human visual determination. Three main factors were investigated, namely, the effect of light, the individual variation and the experience of the observer. Material and methods: At the first experiment, on ten patients, one operator independently selected the best matching shade to the unrestored maxillary central incisor, using a Vita Classical Shade Guide in the morning, at noon and in the afternoon. The same teeth were measured by means of a reflectance spectrophotometer. At the second experiment, on ten patients, ten operators (5 experts, 5 novices) selected and measured by the same method above at noon. At the third experiment, the results of the second experiment were divided into two groups, expert and novice, and analyzed. Results: 1. There was significant difference between visual and spectrophotometric assessment (mean ${\Delta}E$ values) in experiment 1, 2, 3 (P < .05). 2. There was no significant difference between experts and novices group, when comparing with each visual and spectrophotometric assessment (mean ${\Delta}E$ values). Conclusion: Spectrophotometer could be used to analyze the shade of natural tooth objectively. Thereby, this method offers the potential tominimize considerably the need for corrections or even remakesafter intraoral try-in of restoration. Furthermore, to achieve its advantage, both the shade-matching environment and communication between dentist and technician should be optimized with use of visual and instrumental shade-matching systems.

Shear bond strength of the three different kinds of resin cement on CAD/CAM ceramic inlay (CAD/CAM 세라믹 인레이에 대한 3종의 레진 시멘트의 전단결합강도에 관한 연구)

  • Baek, Chul-Woo;Park, Cheol-Woo;Park, Jun-Sub;Ryu, Jae-Jun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.1
    • /
    • pp.20-26
    • /
    • 2013
  • Purpose: The purpose of this study was to evaluate the bond strengths between the latest CAD/CAM ceramic inlay and various resin cements which are used primarily for esthetic restoration. Materials and methods: Cylindrical ceramic blocks(Height: 5 mm, diameter: 3 mm) were fabricated by using Cerec3 and bonded on the dentin of the ninety extracted caries-free molars using three different kinds of resin cement(Unicem$^{(R)}$, Biscem$^{(R)}$, and Variolink II$^{(R)}$) according to the manufacturer's instructions. Ninety specimens were divided into 3 groups according to three different kinds of resin cement. Half of each group were conducted thermocycling under the conditions of the $5-55^{\circ}C$, 5,000 cycle but the other half of them weren't. All specimens were kept in normal saline $37^{\circ}C$, for 24 hours before measuring the bond strength. The shear bond strength was measured by Universal testing machine with a cross head speed of 0.5 mm/min. The results were analyzed statistically by t-test and one-way ANOVA. Results: Unicem$^{(R)}$ group showed the highest shear bond strength despite a slight decline by thermocycling. The shear bond strength of Unicem$^{(R)}$ group and ValiolinkII$^{(R)}$ group were significantly influenced by thermocycling, whereas Biscem$^{(R)}$ group was not influenced (P<.05). There were no significant differences in the bond strength between the three groups without thermocycling, but there was significant differences between Unicem$^{(R)}$ group and Valiolink II$^{(R)}$ group with thermocycling(P<.05). Conclusion: It has been shown to be clinically effective when the self-adhesive resin cements Unicem$^{(R)}$ and Biscem$^{(R)}$ were used instead of the etch-and-rinse resin cement Valiolink II$^{(R)}$ during the bonding of CAD/CAM ceramic inlay restorations with teeth.

A STUDY ON MICROLEAKAGE OF PIT AND FISSURE SEALANT AFTER ENAMEL SURFACE TREATMENT (법랑질 표면처리방법에 따른 치면열구전색재의 미세누출에 관한 비교연구)

  • Hyun, Hong-Keun;Kim, Jung-Wook;Lee, Sang-Hoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.3
    • /
    • pp.512-521
    • /
    • 2001
  • Recently. the reintroduction of air-abrasion technology in dentistry has added a new potential method of pretreating teeth prior to placing sealants. The purpose of this in vitro study was to investigate microleakages of several pit and fissure sealants following various surface pre-treatment methods to the enamel, because there was a question concerning the validity of claim that this method was better than the conventional acid etching. Permanent molars were divided randomly into nine groups and treated accordingly: acid etching(group 1, 4, 7), air-abrasion(group 2, 5, 8), acid etching after air-abrasion(group 3, 6, 9). Then the authors placed and cured the three kinds of sealants(group $1\sim3$: Teethmate-F, group $4\sim6$: Ultraseal XT plus, group $7\sim9$: Denseal) according to the manufacturer's order. They were observed to determine the degree of microleakage. And these specimens were separated from the corresponding enamels and examined by Scanning Electron Microscope. The following results were obtained: 1. In comparing microleakage among tooth surface treatment methods, air-abrasion group(group 2, 5, 8) showed the greatest microleakage, while combination(air-abrasion + acid etching) group showed the least (p<0.05). However, no significant differences were found between group 7 and 9. 2. The mean microleakages were ranked as follows(p<0.05): In acid etching groups, group 7> group 4> group 1. In air-abrasive groups, group 8>groups 5> group 2. In combination groups, group 9>group 3> group 6. However, no significant differences were found between group 4 and 7 between group 2 and 5 and between group 3 and 6. 3. SEM showed that comparably longer resin tags were distributed regularly in acid etching groups and that shorter ones irregularly in air-abrasion groups. It also showed that these two kinds of tags were distributed simultaneously in combination groups.

  • PDF