• 제목/요약/키워드: Korean Tank

검색결과 4,088건 처리시간 0.029초

선박용 압축공기 탱크의 피로강도에 관한 연구(I) (A Study on the Fatigue Strength of Compressed Air Tank for Ships(I))

  • 김종호;안재형
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제29권8호
    • /
    • pp.923-928
    • /
    • 2005
  • The estimation of fatigue life at the design stage of the compressed air tank on board is very important in order to arrive at feasible and reliable solutions considering the total lifetime of the tank. In this paper the compressed air tank on board was selected as a model and the change of inside pressure of the tank during normal navigation period was measured and the cycle of fluctuation stress was presumed statistically based on this. Also the effect of stress concentration with the FEM analysis on the longitudinal weld and the mean stress effect on the fatigue strength of compressed air tank were discussed.

태양열 축열조의 종횡비에 따른 열성층화 수치해석 연구 (Numerical Study on Thermal Stratification of the Aspect ratio of Solar Thermal Storage Tank)

  • 주홍진;김정배;곽희열
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 추계학술발표대회 논문집
    • /
    • pp.178-183
    • /
    • 2008
  • The purpose of this study is to compare the effect on the thermal stratification under various aspect ratios in the solar storage tank using FLUENT. Numerical calculations of three designs with different aspect ratio were carried out to show the behaviour of stratification in a solar storage tank. The calculation results show that the thermal stratification of the 2.5:1 aspect ratio solar storage tank can be 6.22% higher then that of the 1.5:1 aspect ratio solar storage tank and 2.68% higher then that of the 2:1 aspect ratio solar storage tank.

  • PDF

Development of the computational program to evaluate heat leak on LNG tank of Natural Gas Vehicle

  • Minkasheva, Alena;Kim, Sung-Joon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제30권7호
    • /
    • pp.771-781
    • /
    • 2006
  • Car acceleration or deceleration induce the surface slope of liquid fuel in the LNG tank. Slope changes the surface area wetted by liquid fuel in the tank and consequently heat leak to the tank. The Fortran program, 'Pro-Heatleak', is developed to evaluate heat leak on LNG tank. The verification test proves the high accuracy of the developed program. The difference between MathCad and computational results is less than 0.07 %. Computational analyses of heat leak are carried out for 10 gallons and 20 gallons of fuel vapor in the tank. With the increasing of fuel vapor volume by 10 percent the wetted surface area and heat leak respectively decrease by 13 percent. The difference between maximum and minimum heat leak is about 10 percent for both 10 gallons and 20 gallons of fuel vapor in the tank.

Transfer Function Method를 이용한 자동차 연료탱크의 진동 피로 해석에 대한 연구 (Vibration Fatigue Analysis of Automotive Fuel Tank Using Transfer Function Method)

  • 안상호
    • 자동차안전학회지
    • /
    • 제12권3호
    • /
    • pp.27-33
    • /
    • 2020
  • In this paper, the process of predicting efficient durability performance for vibration durability test of automobile parts using vibration test load on automobile fuel tank is presented. First of all, the common standard load that can be applied to the initial development process of the automobile was used for the fuel tank and the vulnerability of the fuel tank to the vibration fatigue load was identified through frequency response analysis. In addition, the vulnerability of the fuel tank was re-enacted through vibration durability test results, and the scale factor was applied to the standard load. In order to predict the vibration durability performance required for detailed design, vibration fatigue analysis was performed on the developed vehicle with the frequency of vibration severity equivalent to the durability test, and the vulnerability and life span of the fuel tank were identified through the process of applying weights to these selected standard loads, thereby reducing the test time of the development vehicle.

An Empirical Study for the Safe and Effective Operations in Membrane LNG Ships focused on the Tank Cool Down

  • Gim, S.G.;Kim, S.W.
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2005년도 연구개발 발표회 논문집
    • /
    • pp.566-572
    • /
    • 2005
  • The most crucial factor in membrane LNG ships to ensure sage operations, is how to effectively control tank pressure at the time of excessive generation of boil off gas (BOG). When the ships carry out tank cool down with her retaining heel prior to arrival at loading port, the vessel encounters the critical situation of excessive BOG and high tank pressure that can lead to high degree of risk. This is to provide one of the best ways to secure safe and effective LNG ship operations focusing on the detailed methods of tank cool down to achieve ATR(Arrival Temperature requirement) without building up high tank pressure and excessive BOG and calculating the appropriate heel quantity to be unutilized for tank cool down and fuel during ballast voyage.

  • PDF

믹서의 가동 수 및 각도 변화에 따른 유동형 지붕 탱크의 유동특성 (Flow Characteristics of Floating Roof Tank with Varying the Number of Operation and Angle)

  • 김노형
    • 한국유체기계학회 논문집
    • /
    • 제18권3호
    • /
    • pp.20-25
    • /
    • 2015
  • In this study, there are 6 mixers that are installed in a 600,000 barrel tank. We identified internal flow characteristics of floating roof tank with varying the number of operation from 4 to 6 because mixer is a variable that influence flow characteristics of the tank. And while varying an angle from Right $60^{\circ}$, Right $30^{\circ}$, Left $30^{\circ}$ to Left $60^{\circ}$, we identified internal flow characteristics of the tank. As a result, maximum velocity of flow was 0.02m/s stationarily when we changed the number of operation from 4 to 6. Maximum velocity of flow by change of an angle was from 0.42m/s to 0.47m/s. Therefore, we identified that these factors don't have a great influence on internal flow characteristics of a tank by investigating results with varying the number of operation and an angle.

LNG 탱크 컨테이너의 내부압력 변화 분석 및 실제 홀딩타임 측정 (Internal Pressure Variation Analysis and Actual Holding Time Test on ISO LNG Tank Container)

  • 류영돈;이진한;조영도;오영삼;차경호
    • 한국가스학회지
    • /
    • 제17권6호
    • /
    • pp.1-7
    • /
    • 2013
  • 이 논문에서는 특례기준에 따라 국내에서 최초로 제작하고 검사한 LNG 탱크 컨테이너를 이용하여 육상 및 해상 운송 시연사업을 하고, 탱크 컨테이너를 운송할 때 탱크 컨테이너 내부에 충전된 LNG의 압력변화와 탱크 컨테이너의 실제 압력유지기간을 측정하였다. 탱크 컨테이너 내부의 압력은 충전 직후에는 급속하게 상승하고, 탱크 컨테이너를 이동할 때 급속히 하강하나, 일정시간이 경과한 후에는 기액평형상태 그래프의 온도-압력 변화와 일치함을 확인하였다. 또한, 탱크 컨테이너의 실제 압력유지기간은 특례기준에서 규정한 20일 이상을 만족함을 확인하였다.

외부화재시 LPG 소형저장탱크의 안전성에 관한 연구 (A Study on the Safety of Small LPG Storage Tanks at External Fires)

  • 임지표;마병철;정창복
    • 한국안전학회지
    • /
    • 제30권4호
    • /
    • pp.64-72
    • /
    • 2015
  • The purpose of this study is to study the safety of a small LPG storage tank with a capacity less than 3 ton when it is exposed to an external fire. First, simulation studies were carried out using ASPEN Plus and PHAST to demonstrate that overpressurization in the tank can be relieved by discharging the LPG through an adequately sized safety valve, but the release may lead to the secondary risk of fire and explosion around the tank. Next, the temporal variations of the temperatures of the lading and tank wall were obtained using AFFTAC, which showed that the tank wall adjacent to the vapor space could be overheated in about 11 min to such a point that the weakened strength might cause a rupture of the tank and subsequent BLEVE. The consequences of the BLEVE were estimated using PHAST. Finally, several practical measures for preventing the hazards of overheating were suggested, including an anti-explosion device, sprinkling system, insulation, heat-proof coating, and enhanced safety factor for tank fabrication. The effectiveness of these measures were examined by simulations using AFFTAC and ASPEN Plus.

전력용 변압기 외함 소음저감에 관한 연구 (A Study on the Tank Noise Reduction Techniques of Power Transformers)

  • 권동진;구교선;김정찬;김유현
    • 전기학회논문지
    • /
    • 제57권10호
    • /
    • pp.1759-1766
    • /
    • 2008
  • According to the increase of power demand and expansion of downtown, it is necessary to install transformers additionally in operating substations and construct substations in residential area. But the public complaint has been increased due to the transformer noise of the substation. KEPCO has used a vibration preventing pad, various soundproof walls and an encloser to transformers in outdoor substations, and a soundproof door, shutter and wind-path soundproof equipment in indoor substations to block the sound propagation from the transformers. But these noise reduction methods are not satisfied. It should be considered to reduce transformer noise itself. In this paper, we investigated tank noise reduction techniques to develope a low noise transformer. According to the mode analysis of transformer tank, we found out characteristics and locations of noise on the tank, and it's nature vibration was also analysed. On the basis of these analysis, reinforcement equipment was installed around transformer tank, and ellipse shape tank was changed to round shape tank. The effect of noise reduction was evaluated using noise generation source.

연료탱크의 낙하 시험 시뮬레이션 (Drop Test Simulation of a Fuel Tank)

  • 박선영;배재성;황재혁;이수용;정태경
    • 한국항공우주학회지
    • /
    • 제36권10호
    • /
    • pp.1032-1037
    • /
    • 2008
  • 항공기의 기체 생존성에 있어서 연료탱크는 중요한 부분이다. 회전익 항공기의 연료탱크는 자기 밀폐성과 내충돌성의 기능을 필요로 한다. 이에 따라 고기능유연연료탱크를 필요로한다. 이 논문에서는 상용 소프트웨어인 MSC.DYTRAN을 이용하여 연료탱크의 낙하시험을 시뮬레이션 하였다. 연료탱크 낙하 시험 시 시험 큐브의 파손 없이 내충돌성 요구조건을 만족하는지 알아보았다.