• 제목/요약/키워드: Korean Oncology

검색결과 6,345건 처리시간 0.035초

Need to Pay More Attention to Attendance at Follow-Up Consultation after Cancer Screening in Smokers and Drinkers

  • Shin, Jaeyong;Park, Eun-Cheol;Bae, Hong-Chul;Hong, Seri;Jang, Suk-Yong;Kim, Jae-Hyun;Chang, Jee Suk;Lee, Sang Gyu
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권1호
    • /
    • pp.109-117
    • /
    • 2015
  • Background: Follow-up clinical consultations could improve overall health status as well provide knowledge and education for cancer prevention. Materials and Methods: This is the cross-sectional study using the Korean Community Health Survey (KCHS) 6th edition for 2012, with 115,083 respondents who underwent cancer checkups selected as subjects. Associations between the presence of consultation and the socioeconomic status were determined using statistical methods with the SAS 9.3 statistical package (Cary, NC, USA). Findings: Among the recipients, 32,179 (28.0%) received clinical consultations after cancer screenings. Those in rural areas (odds ratio, OR=0.71, 95% confidence interval (CI), 0.69-0.73) visited follow-up clinics less frequently than did those in urban areas. Starting at the elementary school level, as the education level increased to middle school (OR=1.26, 95% CI: 1.19-1.34), high school (OR=1.29, 95% CI: 1.23-1.36) or college (OR=1.76, 95% CI: 1.65-1.89), the participation rates also increased. When compared with the lowest quartile group, the quartile income level showed a statistical trend and difference as follows: second lowest quartile (OR=1.11, 95% CI: 1.07-1.16), third lowest (OR=1.12, 95% CI: 1.07-1.17) and highest quartile income (OR=1.29, 95% CI: 1.23-1.35). In addition, the people with economic activities (OR=0.87, 95% CI: 0.84-0.90) visited follow-up clinics less frequently than did the others. Current smokers (OR=0.93, 95% CI: 0.89-0.98) and inveterate drinkers (OR=0.88, 95% CI: 0.85-0.94) had a tendency to visit less often than did non-smokers and other drinkers with all cancers combined. Interpretation: We suggest primary prevention through lifestyle modifications including smoking and drinking, and environmental interventions may offer the most cost-effective approach to reduce the cancer burden.

방사선 수술시 경험적 표적 근사화에 근거한 최적화 방법 개선 (Improvement of a Planning Technique Based on Heuristic Target Shaping for Stereotactic Radiosurgery)

  • 오승종;최경식;송주영;서태석
    • 한국의학물리학회지:의학물리
    • /
    • 제16권4호
    • /
    • pp.176-182
    • /
    • 2005
  • 정위적 방사선수술(stereotactic radiosurgery, SRS)은 한번에 고선량의 방사선을 병변에 조사하는 방사선 치료법으로 단 한번의 조사로 고선량의 방사선이 환자에게 주어지므로 정확한 수술계획의 수립이 필요하다. 현재, 수술계획은 수술계획자에 의해 직접 시행착오를 거듭하며 수립되고 있으며 이로 인해 계획의 재연성과 신뢰성에 문제가 제기되고 있다. 본 연구에서는 경험적 표적 근사화에 근거한 오등의 연구방법을 바탕으로 각 단계를 개선하여 더 나은 수술계획 결과를 얻을 수 있도록 하였다. 주어지는 병소의 다양한 모양을 동일한 높이의 원통을 사용해 근사화하고, 각각의 원통의 중심점의 위치와 지름에 의해 주변의 원통과 하나로 결합시켰다. 그 후 각각의 원통 내에 등선량중심점(Isocenter)을 모사한 구를 미리 정의된 규칙에 의해 채워 나갔다. 두 개의 가상 표적을 이용해 기존 알고리듬과 본 연구에서 개선한 알고리듬을 이용해 최적화를 수행하였다. 그 결과 두 개의 가상 표적에서 PITV (proscription isodose to tumour volume ratio)와 MDPD (maximum dose to prescription dose ratio)의 별다른 차이가 보이지 않았으며, 사용된 구의 수를 각각 $36\%$, $26\%$ 줄일 수 있었다. 원통과 구형을 이용한 이러한 기법은 정위적 방사선 수술시 수술 계획자에게 도움을 줄 수 있을 것으로 생각된다.

  • PDF

방사선치료계획을 위한 PET 종양용적 결정 연구: 컴퓨터 모의실험 (Determination of Tumor Volume in PET for the Radiation Treatment Planning: Computer Simulation)

  • 윤석남;조철우;이재성
    • 한국의학물리학회지:의학물리
    • /
    • 제16권4호
    • /
    • pp.183-191
    • /
    • 2005
  • PET 기기의 보급이 급속도로 증가하고 있으며 여러 임상 및 연구 분야에서 그 유용성이 입증되어 널리 이용되고 있다. 이 가운데서도 종양 진단 분야에서 PET의 활용도는 매우 높아 대부분의 PET검사를 종양 검사가 차지하고 있으며 특히 양성과 악성종양의 감별, 종양의 치료효과 판정 및 종양의 재발진단 등에 널리 이용되고 있다. 최근에는 PET과 CT를 결합한 PET-CT의 사용이 증가됨에 따라 방사선치료분야에서 PET의 활용에 대한 관심이 커지고 있다. 방사선치료를 위한 종양의 경계를 결정하기 위하여 해부학적인 영상인 CT를 이용하는 것이 보편적이나 이 경우 실제 암조직에 상관없이 모양만을 기준으로 삼으므로 암조직에 대한 방사선 치료 용량이 많거나 적을 수 있어 적절한 치료가 되지 않을 수 있다. 따라서 PET을 이용한 기능적이고 살아 있는 암조직의 정확한 용적 측정은 적절한 치료 지표를 줄 수 있어 매우 중요한 일이나 상대적으로 낮은 공간해상도에 의해 정확한 경계를 결정하기 어려운 문제가 있다. 이 연구에서는 실제 종양의 용적을 구할 수 있는 영상화소 값의 역치가 변변의 크기, PET 기기의 공간해상도, 병변 대 주변 섭취비에 어떠한 영향을 받는지를 평가하기 위한 컴퓨터 모의실험을 수행하였다.

  • PDF

열형광선량계용 팬톰을 이용한 호흡 움직임에 따른 선량분포의 평가 (Analysis of the Respiratory Motion Effects on Dose Distribution Using TLD Phantom)

  • 홍주영;김연래;라정은;정진범;서태석
    • 한국의학물리학회지:의학물리
    • /
    • 제17권4호
    • /
    • pp.187-191
    • /
    • 2006
  • 본 연구에서는 열형광선량계(TLD)용 팬톰을 설계 및 제작하고 구동장치에 위치시켜 팬톰이 호흡과 유사하게 움직이는 경우에 선량분포의 변화를 측정하였다. 제작된 팬톰은 TLD를 최소 3 mm 간격으로 위치시킬 수 있는 TLD용 판과 필름을 장착시킬 수 있는 판으로 구성된다. 선량분포 측정을 위하여 팬톰 속 깊이 1.5 cm ($d_{max}$)에 TLD가 배열된 판을 삽입하고, 6 MV X-선이 조사되는 상태에서 팬톰을 SI 방향으로 $1{\sim}2cm$ 범위에서 0.5 cm 간격으로 왕복운동하도록 하였다. 측정된 선량 프로파일에서 이동범위에 따른 반음영과 반측폭을 구하여 정지 상태와 비교한 결과 팬톰의 이동범위가 증가함에 따라 반음영 영역은 0.71 cm에서 2.10 cm로 증가하였으며 반측폭은 7.52 cm에서 7.02 cm로 감소하였다. 본 연구에서는 필름을 사용하여 위의 결과를 재확인한 결과 유사한 경향을 나타내었다. 따라서 호흡에 의해 위치의 변화가 발생하는 종양에 대하여 치료계획을 수립하는 경우에 이 결과를 고려한다면 치료 효과 향상에 기여할 것으로 기대된다.

  • PDF

F-18 FDG PET/CT 전신 영상에서 SUVs 측정에 기반한 조기/정밀 진단 연구 (Enhancement of the Early/Precise Diagnosis Based on the Measurement of SUVs in F-18 FDG PET/CT Whole-body Image)

  • 박정규;김성규;조인호;공은정;박명환;조복연
    • 한국의학물리학회지:의학물리
    • /
    • 제24권3호
    • /
    • pp.176-182
    • /
    • 2013
  • 본 연구의 목적은 건강한 검진자들을 대상으로 F-18 FDG PET/CT 전신 영상에서 진단 수준을 향상하고자 관심부피를 이용하여 정상부위의 SUVs, 즉 SUVLBM, SUVBW, SUVBSA의 데이터를 마련하였다. 각각의 최대치(maximum), 평균치(mean), 표준편차(standard deviation), 역치(threshold)를 제시 하고자 한다. 2012년 7월부터 8월까지 전신 F-18 FDG PET/CT 검사를 시행한 총 31명을 대상으로 SUVs를 측정 하였다. 측정의 정확도를 높이고자 핵의학 전문의의 소견으로 이중에서 26명의 건강한 수검자를 대상으로 하였다. 조영제 사용유무와 관계없이 PET/CT의 SUVs 측정에서 SUVBW의 측정치가 가장 높았으며, SUVLBM, SUVBSA 순으로 나타났다. SUVLBM-최대치를 이용하여 조영제를 사용하지 않은 군과 사용한 군을 비교했을 경우, 조영제를 사용했을 경우 측정치가 증가하는 경향을 보였으며, 8부위 중 간, 대동맥, 요추-5, 소뇌는 매우 유의하게 차이가 있는 것으로 나타났다(p<0.05). PET/CT의 모든 영상의 판독에서 본 SUVs 데이터가 조기정밀/진단 수준을 향상 하는데 기초 자료가 될 것이라고 판단되며, VOI를 이용한 연구가 활발히 이루어지길 기대한다.

CCD기반의 방사선치료 중 실시간 자동 환자 위치보정 시스템 개발: 타당성 연구 (The Development of Real Time Automatic Patient Position Correction System during the Radiation Therapy Based on CCD: A Feasibility Study)

  • 신동호;정광주;김미영;손재만;윤명근;임영경;이세병
    • 한국의학물리학회지:의학물리
    • /
    • 제24권3호
    • /
    • pp.191-197
    • /
    • 2013
  • 방사선 치료 시 방사선이 조사되는 동안 환자의 움직임을 모니터링하는 것은 치료의 성공을 결정 하는 중요한 요인이다. 따라서 방사선이 조사되는 동안 환자의 움직임을 실시간으로 감시하고 움직인 치료위치를 자동으로 보정 할 수 있는 시스템을 개발 하였다. 원점을 중심으로 직교하게 위치한 2개의 CCD 카메라를 이용하여 3차원적 환자의 위치를 확인 하고, 틀 맞춘 상호교차 비교법(normalized cross-correlation method)을 이용한 영상 본 맞춤(image pattern matching) 방법을 이용한 환자위치 모니터링 시스템을 개발하였다. CCD카메라로부터 촬영된 영상을 컴퓨터로 전달하여 위치 변화를 정량적으로 분석 하여 빔 켜고 끔(beam on and off)를 위한 방아쇠신호(trigger signal)를 발생시키고, 이동치료대(moving couch)의 모터를 제어할 수 있는 시스템을 개발하였다. 이 시스템은 0.5 mm 이하의 분해능으로 환자의 위치를 자동으로 보정할 수 있었다.

Evaluating Correlation between Geometrical Relationship and Dose Difference Caused by Respiratory Motion Using Statistical Analysis

  • Shin, Dong-Seok;Kang, Seong-Hee;Kim, Dong-Su;Kim, Tae-Ho;Kim, Kyeong-Hyeon;Cho, Min-Seok;Noh, Yu-Yoon;Yoon, Do-Kun;Suh, Tae Suk
    • 한국의학물리학회지:의학물리
    • /
    • 제27권4호
    • /
    • pp.203-212
    • /
    • 2016
  • Dose differences between three-dimensional (3D) and four-dimensional (4D) doses could be varied according to the geometrical relationship between a planning target volume (PTV) and an organ at risk (OAR). The purpose of this study is to evaluate the correlation between the overlap volume histogram (OVH), which quantitatively shows the geometrical relationship between the PTV and OAR, and the dose differences. 4D computed tomography (4DCT) images were acquired for 10 liver cancer patients. Internal target volume-based treatment planning was performed. A 3D dose was calculated on a reference phase (end-exhalation). A 4D dose was accumulated using deformation vector fields between the reference and other phase images of 4DCT from deformable image registration, and dose differences between the 3D and 4D doses were calculated. An OVH between the PTV and selected OAR (duodenum) was calculated and quantified on the basis of specific overlap volumes that corresponded to 10%, 20%, 30%, 40%, and 50% of the OAR volume overlapped with the expanded PTV. Statistical analysis was performed to verify the correlation with the OVH and dose difference for the OAR. The minimum mean dose difference was 0.50 Gy from case 3, and the maximum mean dose difference was 4.96 Gy from case 2. The calculated range of the correlation coefficients between the OVH and dose difference was from -0.720 to -0.712, and the R-square range for regression analysis was from 0.506 to 0.518 (p-value <0.05). However, when the 10% overlap volume was applied in the six cases that had OVH value ${\leq}2$, the average percent mean dose differences were $34.80{\pm}12.42%$. Cases with quantified OVH values of 2 or more had mean dose differences of $29.16{\pm}11.36%$. In conclusion, no significant statistical correlation was found between the OVH and dose differences. However, it was confirmed that a higher difference between the 3D and 4D doses could occur in cases that have smaller OVH value.

Differentiation between Glioblastoma and Primary Central Nervous System Lymphoma Using Dynamic Susceptibility Contrast-Enhanced Perfusion MR Imaging: Comparison Study of the Manual versus Semiautomatic Segmentation Method

  • Kim, Ye Eun;Choi, Seung Hong;Lee, Soon Tae;Kim, Tae Min;Park, Chul-Kee;Park, Sung-Hye;Kim, Il Han
    • Investigative Magnetic Resonance Imaging
    • /
    • 제21권1호
    • /
    • pp.9-19
    • /
    • 2017
  • Background: Normalized cerebral blood volume (nCBV) can be measured using manual or semiautomatic segmentation method. However, the difference in diagnostic performance on brain tumor differentiation between differently measured nCBV has not been evaluated. Purpose: To compare the diagnostic performance of manually obtained nCBV to that of semiautomatically obtained nCBV on glioblastoma (GBM) and primary central nervous system lymphoma (PCNSL) differentiation. Materials and Methods: Histopathologically confirmed forty GBM and eleven PCNSL patients underwent 3T MR imaging with dynamic susceptibility contrast-enhanced perfusion MR imaging before any treatment or biopsy. Based on the contrast-enhanced T1-weighted imaging, the mean nCBV (mCBV) was measured using the manual method (manual mCBV), random regions of interest (ROIs) placement by the observer, or the semiautomatic segmentation method (semiautomatic mCBV). The volume of enhancing portion of the tumor was also measured during semiautomatic segmentation process. T-test, ROC curve analysis, Fisher's exact test and multivariate regression analysis were performed to compare the value and evaluate the diagnostic performance of each parameter. Results: GBM showed a higher enhancing volume (P = 0.0307), a higher manual mCBV (P = 0.018) and a higher semiautomatic mCBV (P = 0.0111) than that of the PCNSL. Semiautomatic mCBV had the highest value (0.815) for the area under the curve (AUC), however, the AUCs of the three parameters were not significantly different from each other. The semiautomatic mCBV was the best independent predictor for the GBM and PCNSL differential diagnosis according to the stepwise multiple regression analysis. Conclusion: We found that the semiautomatic mCBV could be a better predictor than the manual mCBV for the GBM and PCNSL differentiation. We believe that the semiautomatic segmentation method can contribute to the advancement of perfusion based brain tumor evaluation.

실시간 광학적 생검에서 형광분광법의 산란과 흡수에 대한 영향 (The Scattering and Absorption Effects of Fluorescence Spectroscopy in a Real Time Optical Biopsy)

  • Han, Seunghee;Muller, Markus G.;Kang, Seunghee;Kang, Haejin
    • 한국의학물리학회지:의학물리
    • /
    • 제12권1호
    • /
    • pp.79-94
    • /
    • 2001
  • 생물학적 조직(Biological Tissue)에서 얻어내는 형광(Fluorescence)은 산란(Scattrering), 흡수(Absorption), 그리고 형광체(Fluorophores)가 원인이 되는, 인트린식 형광(Intrinsic Fluorescence)들에 관한 정보를 갖고 있다. 생물학적 조직의 형광스펙트럼은 조직 내에 존재하는 흡수체(Absorber)와 산란물질(Scatters)들의 영향을 받기 때문에 다른 조직의 생화학적인 인트린식 형광을 선형적인 조합으로 해석할 수 없었다. 생물학적 조직 같은 터비드 매질(Turbid Media)로부터 실험적으로 형광을 얻어서 산란과 흡수의 영향을 조사하기 위하여 본 연구소에서 제작한 장치를 소개하고, 넓은 범위의 흡수체와 산란물질의 농도를 갖고 제작한 조직 팬텀(Tissue Phantom)에 대한 형광과 반사(Reflectance) 스펙트럼을 측정하였다. 형광스펙트럼에 존재하는 산란과 흡수의 왜곡(Distortion)을 제거하기 위하여, 반사스펙트럼에 포함된 산란과 흡수 정보를 이용하는 ‘광자 이동 모델(Photon Migration Model)’을 적용하였고, 이러한 조직모델에 대한 인트린식 형광을 얻었다 연구 결과, 모델 값과 실제 인트린식 형광 스펙트럼이 훌륭하게 일치함을 확인하였다. 이런 연구를 하게된 동기는, 인간의 조직이 병들어서 진화하면 조직의 생화학적 구성의 변화가 발생하고 이때 인트린식 형광의 변화가 생기기 때문이다 결론적으로, 조직에 대한 실시간 광학적 생검에서 병든 조직과 정상조직을 단지 형광스펙트럼만으로 구분하는 것은 어렵지만, 인트린식 형광을 이용하면 가능하다.

  • PDF

화학증착된 다이어몬드 박막의 파장 분해된 열자극발광 (Wavelength-resolved Thermoluminescence of Chemical-vapor-deposited Diamond Thin Film)

  • Cho, Jung-Gil;Yi, Byong-Yong;Kim, Tae-Kyu
    • 한국의학물리학회지:의학물리
    • /
    • 제12권1호
    • /
    • pp.1-8
    • /
    • 2001
  • 다이아몬드는 radiation hardness가 크고, 화학적으로 안정하고, 특히 조직 등 물질이기 때문에, 선량계 분야에서 각광을 받고 있다. 화학증착법(CVD)에 의해 다이아몬드 박막을 성장시켰고, 선량계로 응용될 수 있는 열자극발광 특성을 조사하였다. 다이아몬드 박막의 라만 스펙트럼은 1332 cm-1에서 peak를 가졌고, X-선 굴절 패턴은 (111) 면을 보였다. 전자주사사진으로부터 다이아몬드박막은 pyramidal hillock을 가지는 unepitaxial crystallite 로 성장됨을 알았다. X-선 조사된 CVD 다이어몬드 박막의 파장 분해된 열자극발광은 430 nm 및 560 K에서 하나의 봉우리를 가졌다. 560 K에서 주된 봉우리를 가지는 CVD 다이어몬드 박막의 열자극발광 곡선은 1st-order kinetics에 기인한다. 이 봉우리의 활성화 에너지 및 이탈진동수는 각각 0.92 ~ 1.05 eV 및 1.34 $\times$ $10^{7}$ sec$^{-1}$ 이다. 560 K에서 방출되는 스펙트럼은 1.63-eV, 2.60-eV 및 3.07-eV 방출 띠로 분해되며, 이들은 각각 silicon-vacancy center, A center 및 H3 center에 기인한다.

  • PDF