• Title/Summary/Keyword: Korean Oncology

Search Result 6,372, Processing Time 0.033 seconds

Study on Absorbed Dose Determination of Electron Beam Quality for Cross-calibration with Plane-parallel Ionization Chamber (평행평판형이온함의 교차교정 시 전자선 선질에 따른 흡수선량 결정에 대한 연구)

  • Rah, Jeong-Eun;Shin, Dong-Oh;Park, So-Hyun;Jeong, Ho-Jin;Hwang, Ui-Jung;Ahn, Sung-Hwan;Lim, Young-Kyung;Kim, Dong-Wook;Yoon, Myong-Geun;Shin, Dong-Ho;Lee, Se-Byeong;Suh, Tae-Suk;Park, Sung-Yong
    • Progress in Medical Physics
    • /
    • v.20 no.2
    • /
    • pp.97-105
    • /
    • 2009
  • Absorbed dose to water based protocols recommended that plane-parallel chambers be calibrated against calibrated cylindrical chambers in a high energy electron beam with $R_{50}$>7 $g/cm^2$ (E${\gtrsim}$16 MeV). However, such high-energy electron beams are not available at all radiotherapy centers. In this study, we are compared the absorbed dose to water determined according to cross-calibration method in a high energy electron beam of 16 MeV and in electron beam energies of 12 MeV below the cross-calibration quality remark. Absorbed dose were performed for PTW 30013, Wellhofer FC65G Farmer type cylindrical chamber and for PTW 34001, Wellhofer PPC40 Roos type plane-parallel chamber. The cylindrical and the plane-parallel chamber to be calibrated are compared by alternately positioning each at reference depth, $Z_{ret}=0.6R_{50}-0.1$ in water phantom. The $D_W$ of plane-parallel chamber are derived using across-calibration method at high-energy electron beams of 16, 20 MeV. Then a good agreement is obtained the $D_W$ of plane-parallel chamber in 12 MeV. The agreement between 20 MeV and 12 MeV are within 0.2% for IAEA TRS-398.

  • PDF

Burden, Job Satisfaction and Quality of Life of Nurses Caring for Cancer Patients (암 환자를 돌보는 간호사의 부담감, 직무 만족도 및 삶의 질)

  • Park, Mi-Sun;Yoo, Yang-Sook
    • Journal of Hospice and Palliative Care
    • /
    • v.8 no.1
    • /
    • pp.8-17
    • /
    • 2005
  • Purpose: This study was performed to investigate burden, job satisfaction and quality of life of nurses who take care of cancer patients. Methods: The subjects were 237 nurses working at the oncology unit of hospitals with over 500 beds in Seoul and Gyeonggi-do. Data were collected using questionnaire from the February to March, 2005. Data were analyzed through t-test, ANOVA, Pearson's correlation coefficient and stepwise multiple regression using SAS. Results: 1. The item that showed the highest level of burden was 'I feel limited even if I make efforts to reduce patients' pain. 'Burden was high in those group both who were younger than 35 years old and who had clinical experiences caring cancer patients for $3{\sim}4$ years. 2. The item that showed the lowest level of job satisfaction was 'the possibility of promotion'. Job satisfaction was high in those group both who had a spouse and were head nurses or incharge nurses. 3. The item that showed the lowest level of quality of life was 'I am physically exhausted'. Over 35 years old who had a spouse, and over 2,000,000 won monthly income made a high score in the quality of life. 4. There were negative correlations among burden, iob satisfaction and the quality of life. 5. The major factor affecting the quality of life was burden. Conclusion: The results of this study are expected to be utilized as basic data for developing support system to improve nurses' work conditions and quality of life.

  • PDF

Evaluation of cardiac function by tissue Doppler imaging in children with cancer (Tissue Doppler imaging을 이용한 소아 종양 환자에서의 심기능 평가)

  • Kim, Yeo Hyang
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.4
    • /
    • pp.417-423
    • /
    • 2006
  • Purpose : The objectives of this study were to assess ventricular function by tissue Doppler imaging in children who were receiving chemotherapy or who had received chemotherapy, and to apply repeated tissue Doppler imaging to make an early assessment in cardiac toxicity studies. Methods : This study was conducted on 23 oncology patients on-treatment or off-treatment from April 2005 to July 2005 at Dongsan Medical Center, Keimyung University. All patients(group 1) were divided into two groups, fractional shortening(FS) over 29 percent(group 2) and FS under 28 percent (group 3) in the first category. These same patients were also divided into the following groups : group treated with anthracyclin(group 4) and group treated without anthracyclin(group 5). Deceleration time(DT), isovolumic relaxation time(IVRT), FS, peak early diastolic(E), and peak late diastolic (A) velocity of transmitral flow were measured by M-mode and pulsed wave Doppler. Systolic(Sm), peak early diastolic(Em), and peak late diastolic(Am) velocity in apical 4-chamber and 2-chamber views were measured by tissue Doppler imaging. The author calculated a modified Tei index, E/A, E/Em ratio by using measured values. Results : Twenty three patients were enrolled : 12 boys and 11 girls. The average age of patients was 8 years and 4 months. Thirteen out of 23 patients were in the group treated with anthracyclin (group 4) and 6 had FS under 28 percent(group 3). E/Em ratio showed a significant difference between group 1 and control group($6.46{\pm}1.85$ vs $7.06{\pm}1.64$, P<0.05). Other parameters had no difference statistically. Conclusion : This study showed that the change of cardiac function developed earlier in diastolic function than in systolic function, as E/Em ratio reflecting the mean LV diastolic pressure showed a significant difference between the control group and chemotherapy groups. Echocardiography using tissue Doppler imaging is a non-invasive, comfortable and reliable method for post-chemotherapy follow up.

The anti-tumor mechanisms of p53 through the regulation of expression and glycosylation of insulin-like growth factor binding protein-3 (암억제 유전자 p53에 의한 insulin-like growth factor binding protein-3의 발현과 glycosylation를 통한 항암작용)

  • Kim, Sun Young;Kim, Se Rim;Lee, Jung Chang;Yi, Ho Keun;Lee, Dae Yeol;Hwang, Pyoung Han
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.4
    • /
    • pp.431-438
    • /
    • 2006
  • Purpose : Insulin-like growth factor binding protein(IGFBP)-3 has been known as a tumor suppressor gene, and its anti-tumor function was divided into insulin-like growth factor(IGF)-dependent and IGF-independent mechanism. In IGF-independent mechanism, IGFBP-3 directly interacts with a cell without binding of IGFs, becoming an interesting object in oncology. Several studies demonstrate that one of the well-known tumor suppressor genes, p53, induces directly IGFBP-3 transcription, and the increment of IGFBP-3 expression induces apoptosis of many cancer cells. Recently, the anti-tumor mechanisms of IGFBP-3 have been reported, but post-translational modification of IGFBP-3 and its anti-tumor mechanism are not well known. In this study, we examined whether p53 regulated the glycosylation of IGFBP-3, and analysed the meaning of IGFBP-3 glycosylation related to the apoptosis of cancer cell. Methods : The p53-mutated status of MDA-MB-231 human breast cancer cells was used in this experiment. The expression and glycosylation of IGFBP-3 were tested by Western blot analysis after infection of adenovirus mediated Ad/p53 and/or Ad/IGFBP-3. Results : Ad/p53 infected cells resulted in growth retardation and the induced apoptosis. p53 induced direct expression and glycosylation of IGFBP-3. The increase of glcosylated IGFBP-3 was able to promote cellular apoptosis, and the glycosylation of IGFBP-3 was more activated by the double treatment of Ad/p53 and Ad/IGFBP-3. Conclusion : From this study, the anti-tumor activity of IGFBP-3 was shown to improve the stabilization of IGFBP-3 through the increment of glycosylation of IGFBP-3 by p53. This result suggests that the combined gene therapy of p53 and IGFBP-3 may appropriate treatment of cancer.

Eating patterns and use of nutritional information in breast cancer survivors treated with radiation therapy in South Korea (일반인과 유방암 환자간의 식행동 및 영양정보에 관한 인식조사)

  • Kim, Kyoung-Ok;Park, Hyunjin;Chun, Mison;Lee, Eun Hyun;Kim, Hyun-Sook
    • Journal of Nutrition and Health
    • /
    • v.46 no.3
    • /
    • pp.250-260
    • /
    • 2013
  • The purposes of this study were 1) to investigate eating behaviors and patterns in breast cancer patients using a newly developed food frequency questionnaire and 2) to examine perception and use of nutritional information about breast cancer treatment among cancer patients treated with radiation therapy. Sixty breast cancer patients (case group) undergoing radiation therapy in Ajou University Hospital, Suwon, South Korea and 79 healthy women (control group) participated in this study. Mean age of subjects in the control group was $46.00{\pm}7.88$ years and BMI was $23.12{\pm}2.85kg/m^2$, and that of the case group was $50.06{\pm}11.64$ years and $22.32{\pm}3.24kg/m^2$. The results of eating behaviors showed several significant differences between control and case groups. Breast cancer patients ate meals on a more regular basis, on time, and more frequently compared to control subjects. In addition, they preferred more salty or spicy and bland food compared to healthy women. According to answers from the food frequency questionnaire, breast cancer patients consumed significantly lower amounts of boiled white rice, meats and processed food, fish and shellfish, coffee, milk, and cheese, whereas they consumed a significantly large amount of boiled multigrain rice, vegetable, seaweeds, soybean and processed food, and yoghurt compared to healthy women. This study also observed the way in which cancer patients and healthy control subjects obtain information about breast cancer treatment and its reliabilities. Results showed that healthy women did not hesitate to obtain information from mass media, while breast cancer patients would obtain nutritional information from specialists rather than mass media. Results of this survey confirmed that breast cancer patients avoided intake of red meat protein, even though they already recognized the importance of dietary protein intake for recuperation and treatment of the disease. These results could be used for future diet and nutrition guidelines for breast cancer patients.

Inhibition of Graft Versus Host Disease Using CD4+CD25+ T Cells Induced with Interleukin-2 in Mismatched Allogeneic Murine Hematopoietic Stem Cell Transplantation (주조직적합항원이 불일치하는 마우스 동종 조혈모세포이식에서 IL-2로 유도된 CD4+CD25+ T세포를 이용한 이식편대숙주병의 억제)

  • Hyun, Jae Ho;Jeong, Dae Chul;Chung, Nak Gyun;Park, Soo Jeong;Min, Woo Sung;Kim, Tai Gyu;Choi, Byung Ock;Kim, Won Il;Han, Chi Wha;Kim, Hack Ki
    • IMMUNE NETWORK
    • /
    • v.3 no.4
    • /
    • pp.287-294
    • /
    • 2003
  • Background: In kidney transplantation, donor specific transfusion may induce tolerance as a result of some immune regulatory cells against the graft. In organ transplantation, the immune state arises from a relationship between the immunocompromised graft and the immunocompetent host. However, a reverse immunological situation exists between the graft and the host in hematopoietic stem cell transplantation (HSCT). In addition, early IL-2 injections after an allogeneic murine HSCT have been shown to prevent lethal graft versus host disease (GVHD) due to CD4+ cells. We investigated the induction of the regulatory CD4+CD25+ cells after a transfusion of irradiated recipient cells with IL-2 into a donor. Methods: The splenocytes (SP) were obtained from 6 week-old BALB/c mice ($H-2^d$) and irradiated as a single cell suspension. The donor mice (C3H/He, $H-2^k$) received $5{\times}10^6$ irradiated SP, and 5,000 IU IL-2 injected intraperitoneally on the day prior to HSCT. The CD4+CD25+ cell populations in SP treated C3H/He were analyzed. In order to determine the in vivo effect of CD4+CD25+ cells, the lethally irradiated BALB/c were transplanted with $1{\times}10^7$ donor BM and $5{\times}10^6$ CD4+CD25+ cells. The other recipient mice received either $1{\times}10^7$ donor BM with $5{\times}10^6$ CD4+ CD25- cells or the untreated SP. The survival and GVHD was assessed daily by a clinical scoring system. Results: In the MLR assay, BALB/c SP was used as a stimulator with C3H/He SP, as a responder, with or without treatment. The inhibition of proliferation was $30.0{\pm}13%$ compared to the control. In addition, the MLR with either the CD4+CD25+ or CD4+CD25- cells, which were isolated by MidiMacs, from the C3H/He SP treated with the recipient SP and IL-2 was evaluated. The donor SP treated with the recipient cells and IL-2 contained more CD4+CD25+ cells ($5.4{\pm}1.5%$) than the untreated mice SP ($1.4{\pm}0.3%$)(P<0.01). There was a profound inhibition in the CD4+CD25+ cells ($61.1{\pm}6.1%$), but a marked proliferation in the CD4+CD25- cells ($129.8{\pm}65.2%$). Mice in the CD4+CD25+ group showed low GVHD scores and a slow progression from the post-HSCT day 4 to day 9, but those in the control and CD4+CD25- groups had a high score and rapid progression (P<0.001). The probability of survival was 83.3% in the CD4+CD25+ group until post-HSC day 35 and all mice in the control and CD4+CD25- groups died on post-HSCT day 8 or 9 (P=0.0105). Conclusion: Donor graft engineering with irradiated recipient SP and IL-2 (recipient specific transfusion) can induce abundant regulatory CD4+CD25+ cells to prevent GVHD.

Analysis on the Positional Accuracy of the Non-orthogonal Two-pair kV Imaging Systems for Real-time Tumor Tracking Using XCAT (XCAT를 이용한 실시간 종양 위치 추적을 위한 비직교 스테레오 엑스선 영상시스템에서의 위치 추정 정확도 분석에 관한 연구)

  • Jeong, Hanseong;Kim, Youngju;Oh, Ohsung;Lee, Seho;Jeon, Hosang;Lee, Seung Wook
    • Progress in Medical Physics
    • /
    • v.26 no.3
    • /
    • pp.143-152
    • /
    • 2015
  • In this study, we aim to design the architecture of the kV imaging system for tumor tracking in the dual-head gantry system and analyze its accuracy by simulations. We established mathematical formulas and algorithms to track the tumor position with the two-pair kV imaging systems when they are in the non-orthogonal positions. The algorithms have been designed in the homogeneous coordinate framework and the position of the source and the detector coordinates are used to estimate the tumor position. 4D XCAT (4D extended cardiac-torso) software was used in the simulation to identify the influence of the angle between the two-pair kV imaging systems and the resolution of the detectors to the accuracy in the position estimation. A metal marker fiducial has been inserted in a numerical human phantom of XCAT and the kV projections were acquired at various angles and resolutions using CT projection software of the XCAT. As a result, a positional accuracy of less than about 1mm was achieved when the resolution of the detector is higher than 1.5 mm/pixel and the angle between the kV imaging systems is approximately between $90^{\circ}$ and $50^{\circ}$. When the resolution is lower than 1.5 mm/pixel, the positional errors were higher than 1mm and the error fluctuation by the angles was greater. The resolution of the detector was critical in the positional accuracy for the tumor tracking and determines the range for the acceptable angle range between the kV imaging systems. Also, we found that the positional accuracy analysis method using XCAT developed in this study is highly useful and will be a invaluable tool for further refined design of the kV imaging systems for tumor tracking systems.

Improvement of the Dose Calculation Accuracy Using MVCBCT Image Processing (Megavoltage Cone-Beam CT 영상의 변환을 이용한 선량 계산의 정확성 향상)

  • Kim, Min-Joo;Cho, Woong;Kang, Young-Nam;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.23 no.1
    • /
    • pp.62-69
    • /
    • 2012
  • The dose re-calculation process using Megavoltage cone-beam CT images is inevitable process to perform the Adaptive Radiation Therapy (ART). The purpose of this study is to improve dose re-calculation accuracy using MVCBCT images by applying intensity calibration method and three dimensional rigid body transform and filtering process. The three dimensional rigid body transform and Gaussian smoothing filtering process to MVCBCT Rando phantom images was applied to reduce image orientation error and the noise of the MVCBCT images. Then, to obtain the predefined modification level for intensity calibration, the cheese phantom images from kilo-voltage CT (kV CT), MVCBCT was acquired. From these cheese phantom images, the calibration table for MVCBCT images was defined from the relationship between Hounsfield Units (HUs) of kV CT and MVCBCT images at the same electron density plugs. The intensity of MVCBCT images from Rando phantom was calibrated using the predefined modification level as discussed above to have the intensity of the kV CT images to make the two images have the same intensity range as if they were obtained from the same modality. Finally, the dose calculation using kV CT, MVCBCT with/without intensity calibration was applied using radiation treatment planning system. As a result, the percentage difference of dose distributions between dose calculation based on kVCT and MVCBCT with intensity calibration was reduced comparing to the percentage difference of dose distribution between dose calculation based on kVCT and MVCBCT without intensity calibration. For head and neck, lung images, the percentage difference between kV CT and non-calibrated MVCBCT images was 1.08%, 2.44%, respectively. In summary, our method has quantitatively improved the accuracy of dose calculation and could be a useful solution to enhance the dose calculation accuracy using MVCBCT images.

A Study of Radiation Exposure in Proton Therapy Facility (양성자치료기 가속기 시설에서의 작업종사자의 방사선 피폭 연구)

  • Lee, Sang-Hoon;Shin, Dong-Ho;Yoon, Myong-Geun;Shin, Jung-Wook;Rah, Jeong-Eun;Kwak, Jung-Won;Park, Sung-Yong;Shin, Kyung-Hwan;Lee, Doo-Hyun;Ahn, Sung-Hwan;Kim, Dae-Yong;Cho, Kwan-Ho;Lee, Se-Byeong
    • Progress in Medical Physics
    • /
    • v.20 no.1
    • /
    • pp.37-42
    • /
    • 2009
  • Proton therapy facility, which is recently installed at National Cancer Center in Korea, generally produces a large amount of radiation near cyclotron due to the secondary particles and radioisotopes caused by collision between proton and nearby materials during the acceleration. Although the level of radiation by radioisotope decreases in length of time, radiation exposure problem still exists since workers are easily exposed by a low level of radiation for a long time due to their job assignment for maintenance or repair of the proton facility. In this paper, the working environment near cyclotron, where the highest radiation exposure is expected, was studied by measuring the degree of radiation and its duration for an appropriate level of protective action guide. To do this, we measured the radiation change in the graphite based energy degrader, the efficiency of transmitted beam and relative activation degree of the transmission beam line. The results showed that while the level of radiation exposure around cyclotron and beam line during the operation is much higher than the other radiation therapy facilities, the radiation exposure rate per year is under the limit recommended by the law showing 1~3 mSv/year.

  • PDF

Bronchoscopy and Surgical Lung Biopsy for the Diagnosis and Management of Pulmonary Infiltrates in Immunocompromised Hosts (면역저하환자에서 발생한 폐침윤에서 기관지내시경과 수술적 폐생검의 유용성)

  • Park, Sang-Joon;Kang, Soo-Jung;Koh, Young-Min;Suh, Gee-Young;Kim, Ho-Joong;Kwon, O-Jung;Lee, Hong-Ghi;Rhee, Chong-H.;Chung, Man-Pyo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.47 no.2
    • /
    • pp.195-208
    • /
    • 1999
  • Background: Pulmonary infiltrate in immunocompromised hosts has many infectious and non-infectios etiologies. To evaluate the diagnostic yield and therapeutic implication of two invasive diagnostic methods, such as bronchoscopy and surgical lung biopsy, we performed retrospective analysis of these patients. Methods: All immunocompromised patients admitted to Samsung Medical Center from October 1995 to August 1998 who underwent bronchoscopy and/or surgical lung biopsy for the diagnosis of pulmonary infiltrates were included in this study. Confirmative diagnostic yield, the rate of changed therapeutic plan and patients' survival were investigated. Results: Seventy-five episodes of pulmonary infiltrates developed in 70 patients(M : F=46 : 24, median age 51). Underlying diseases of patients were hematologic malignancy(n=30), organ transplantation(n=11), solid tumor(n= 12), connective tissue disease(n=6) and others. Confirmative diagnosis was made in total 53 cases (70.7%), of which 70.2% had infectious etiology. Diagnostic yields of bronchoscopy, bronchoalveolar lavage(BAL), transbronchiallung biopsy(TBLB) and surgical lung biopsy were 35.0%(21/60), 31.4%(16/51), 25.0%(9/36) and 80.0%(20/25). Therapeutic plan was changed in 40%(24/60) of patients after bronchoscopy and in 36%(9/25) of patients after surgical lung biopsy. More patients survived (84.4% vs 60.5%, p=0.024) when therapeutic plan was changed after invasive diagnostic study. Conclusion: Bronchoscopy and surgical lung biopsy are helpful for the therapeutic implication of pulmonary infiltrates in immunocompromised hosts. Large-scale prospective case-control study may further clarify their limitation and usefulness.

  • PDF