• Title/Summary/Keyword: Korean Input

Search Result 18,886, Processing Time 0.049 seconds

A Ripple-free Input Current Interleaved Converter with Dual Coupled Inductors for High Step-up Applications

  • Hu, Xuefeng;Zhang, Meng;Li, Yongchao;Li, Linpeng;Wu, Guiyang
    • Journal of Power Electronics
    • /
    • v.17 no.3
    • /
    • pp.590-600
    • /
    • 2017
  • This paper presents a ripple-free input current modified interleaved boost converter for high step-up applications. By integrating dual coupled inductors and voltage multiplier techniques, the proposed converter can reach a high step-up gain without an extremely high turn-ON period. In addition, a very small auxiliary inductor employed in series to the input dc source makes the input current ripple theoretically decreased to zero, which simplifies the design of the electromagnetic interference (EMI) filter. In addition, the voltage stresses on the semiconductor devices of the proposed converter are efficiently reduced, which makes high performance MOSFETs with low voltage rated and low resistance $r_{DS}$(ON) available to reduce the cost and conduction loss. The operating principles and steady-state analyses of the proposed converter are introduced in detail. Finally, a prototype circuit rated at 400W with a 42-50V input voltage and a 400V output voltage is built and tested to verify the effectiveness of theoretical analysis. Experimental results show that an efficiency of 95.3% can be achieved.

Performance of Compressor with Variable Capacity (용량가변 방식을 적용한 압축기의 성능연구)

  • 권영철;진의선;허삼행;김대훈;홍주태;문제명
    • Journal of Energy Engineering
    • /
    • v.13 no.3
    • /
    • pp.214-218
    • /
    • 2004
  • In the present study, the variation of input power and efficiency improvement of a scroll compressor applying PWM method are experimentally investigated. The cooling capacity, input power and COP are measured under the cooling operation. The input power due to the change of the condenser and the coil addition in a main current part is measured to enhance the compressor efficiency. Measured results show that the input power and COP increase with increasing the tooling capacity. And the minimum input power of the compressor is observed. By the adoption of the double system, the consumption of compressor input power is reduced, compared with the existing system.

Multimode Hybrid Control Strategy of LLC Resonant Converter in Applications with Wide Input Voltage Range

  • Li, Yan;Zhang, Kun;Yang, Shuaifei
    • Journal of Power Electronics
    • /
    • v.19 no.1
    • /
    • pp.201-210
    • /
    • 2019
  • This paper proposes a multimode hybrid control strategy that can achieve zero-voltage switching of primary switches and zero-current switching of secondary rectifier diodes in a wide input voltage range for full-bridge LLC resonant converters. When the input voltage is lower than the rated voltage, the converter operates in Mode 1 through the variable-frequency control strategy. When the input voltage is higher than the rated voltage, the converter operates in Mode 2 through the VF and phase-shift control strategy until the switching frequency reaches the upper limit. Then, the converter operates in Mode 3 through the constant-frequency and phase-shift control strategy. The secondary-side diode current will operate in the discontinuous current mode in Modes 1 and 3, whereas it will operate in the boundary current mode in Mode 2. The current RMS value and conduction loss can be reduced in Mode 2. A detailed theoretical analysis of the operation principle, the voltage gain characteristics, and the realization method is presented in this paper. Finally, a 500 W prototype with 100-200 V input voltage and 40 V output voltage is built to verify the feasibility of the multimode hybrid control strategy.

Considerations on Screening for the Input Data of the Biosphere Model in the Radioactive Waste Disposal Facility (방사성폐기물 처분시설에서 생태계 모델의 입력데이터 선정에 대한 고찰)

  • Mi-Seon Jeong;Dong-Kuk Park;Soo-Gin Kim;Kang-Il Jung
    • Journal of Radiation Industry
    • /
    • v.17 no.2
    • /
    • pp.209-217
    • /
    • 2023
  • The biosphere has important function in the safety assessment of a radioactive waste disposal facility. A biosphere model in the safety assessment needs various input data that contain significantly inherent uncertainties. This paper reviews the effects of the input data on the radiological impact assessment from main radionuclides such as 14C and 99Tc in the biosphere model. In addition, it is confirmed that the safety criteria is met, when the conservative input data for the intake rate, soil to plant concentration ratio, and distribution coefficients of the radionuclides are applied and probabilistic analysis are conducted in the biosphere model. Nevertheless, it is required to generate site-specific input data for the confidence building and reduce excessive conservatism in the biosphere model.

An Inter-industry Analysis of the Korean Railway with Input-Output Statistics: A Decade Comparison (철도운송산업의 산업연관 분석 2003~2013년, 지난 10년의 비교)

  • Yoon, Jae-Ho
    • Journal of the Korean Society for Railway
    • /
    • v.19 no.6
    • /
    • pp.815-825
    • /
    • 2016
  • The inter-industrial inducement effects of the Korean railway services on the output, value-added, and imports of 383 industrial sectors of the Korean economy have been computed by the input-output analysis technique utilizing the '2013 Input-Output Statistics', which was published most recently in December 2015 by the Bank of Korea. The research results are, then, compared and contrasted with the former research results with the '2003 Input-0utput Statistics', which were published in the Journal of the Korean Society for Railway, August, 2008. The economic inducement effects computed in this study are as follows. The Korean railway service industry produced \5,841 billion worth of passenger and freight railroad services in the year 2013, and it induced \8,511 billion worth of output, \84 billion worth of value-added, and \1,050 billion worth of imports for Korean industry as a whole.; the production inducement multiplier, value-added multiplier, and imports inducement multiplier of 2013 results are shown to be quite different from 2003 multipliers.; it has been shown that it is necessary to utilize the most recent Input-Output Statistics for the computation of the most recent inter-industrial analysis.

Fuzzy Neural Newtork Pattern Classifier

  • Kim, Dae-Su;Hun
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.1 no.3
    • /
    • pp.4-19
    • /
    • 1991
  • In this paper, we propose a fuzzy neural network pattern classifier utilizing fuzzy information. This system works without any a priori information about the number of clusters or cluster centers. It classifies each input according to the distance between the weights and the normalized input using Bezdek's [1] fuzzy membership value equation. This model returns the correct membership value for each input vector and find several cluster centers. Some experimental studies of comparison with other algorithms will be presented for sample data sets.

  • PDF