• Title/Summary/Keyword: Korean Fire Service

Search Result 629, Processing Time 0.023 seconds

Study on Hazard of Toner Cartridge at Recycle Facilities

  • Koseki, Hiroshi;Iwata, Yusaku;Lim, Woo-Sub
    • International Journal of Safety
    • /
    • v.11 no.1
    • /
    • pp.15-18
    • /
    • 2012
  • Because of development of printing technology, toner cartridge particle becomes smaller and more dangerous. And sometimes we had incidents with dust explosion of toner cartridge particle at recycling facilities in Japan. Therefore we studied on hazard of toner particle relating with dust explosion. We found that toner particle is so dangerous compared with most organic solids, even though it does not belong to hazardous materials in the UN regulation and the Japanese Fire Service Law.

Study on Guideline of Water Supply System for Forest Fire (산불방지 급수시설 설치 기준 마련에 관한 연구)

  • Kim, Dong-Hyun;Nam, Song-Hee;Keum, Si-Hoon
    • Fire Science and Engineering
    • /
    • v.27 no.3
    • /
    • pp.38-46
    • /
    • 2013
  • Permanent water supply and water sprinkling systems are essential to protect major forests and facilities from forest fire. Back in 2005, Naksan Temple, a valuable cultural asset of Korea, was burned down in a forest fire that took place in Yangyang. This started a series of movements including installing water supply facilities and managing forests near important cultural assets. As for the existing facilities, however, they were installed without any standard guidelines for management and installation according to each constructor's specifications, which were based on the National Fire Safety Code 109. Unfortunately, this is not effective in protecting facilities from forest fires such as they have a small protection area, limited simultaneous sprinkling, and a difficult the movement of fire hose. Against this background, the study examines the condition of water supply facilities currently in use, identifies their deficiencies, and suggests how to improve the criteria for water supply service to effectively prevent forest fire. Specifically, three systems were proposed: Water Sprinkler Tower System for preventing spread of crown fires, and Forest Fire Hydrant System and Portable Water Spray System to be effective for suppressing surface fires. In addition, the standards on the performance and components of water pumps are also suggested.

A Study on Activation device of 119 Emergency Care (119구급대의 활성화 방안에 관한 연구)

  • Koh, Jae-Moon;Kim, Gyoung-Wan;Chung, Yong-Tai
    • The Korean Journal of Emergency Medical Services
    • /
    • v.11 no.1
    • /
    • pp.27-40
    • /
    • 2007
  • Even now, 119 rescue services have dissatisfactory aspects in operation, system and equipments as discussed above, It is the most urgent subject to systemize rescue services so that they can be suitable for our status, for we will make 21C welfare state come true before long. So, this author suggest that the followings have to be raised to activate 119 rescue service. 1) Bring up experts and offer high-quality rescue service 2) Prepare more up-to-date equipments 3) Operate transfer joint organizations 4) Promote the ability to meet with a press at the time of rescue service activities 5) Adjust regulations related to rescue services 6) Make up for a countermeasure to traffic accidents of ambulances 7) Adjust regulations making it mandatory to establish heliport at the target on hospitals more than a defined scale 8) Install more rescue service teams 9) Educate and train officials belonging to briefing rooms, where the officials with long experiences are arranged 10) Minimize the time for rescue team to reach fields 11) Establish legal protection system for rescue the team Nowadays, our country operates the department of fire fighting and rescue services without great difficulty, even though the circumstances are bad - insufficient members and the inferior circumstances. All of the fire fighting officials are given heavy duties in bad circumstances, and so are the team of rescue service. The rescue service team, taking charge of some emergency medical system, do a fire fighting inspection as a non-duty service, though they are scanty of sleep due to prevention and protection services of the fire fighting service team. But, they can not engage in rescue services completely and have to deal with miscellaneous duties. So they can not offer professional emergency medical services. But now, almost every fire fighting organization, belonging to National Emergency Management Agency, are separating rescue services, which shows a lot of good results. People recognize rescue services to get better and better gradually and the demands for this rescue services increase. So, this is the best time when rescue service teams should offer qualitative services rather than quantitative services. The people will recognize this rescue service team to be an organization sacrificing and serving for them. However well institutes and operation systems should be established, the rescue service team can not come true their aim without strong wills that they will serve and sacrifice themselves for people from their hearts. In addition, it is essential for the officials in charge of policies about emergency medical services to have a concernment on and practice the policy without failure.

  • PDF

A Study on the Proposal of Durability and Service Life of Fire Door in apartment house (공동주택 방화문의 내구성능 및 내용연수 제안에 관한 연구)

  • Kwon, Yeong-Jin;Kim, Yun-Seong;Jin, Seung-Hyeon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.11a
    • /
    • pp.49-50
    • /
    • 2022
  • There are continuous cases of fire expansion due to fire door problems around the world, including the 2010 Shanghai Apartment Fire, the 2017 Grenfell Tower Fire in England, and the 2020 Ul-san Residential and Commercial Complex Fire. In order to prevent such fire damage, the country has strengthened the performance standards of fire doors, and recently, efforts have been made to ensure the best performance of fire doors by introducing a quality recognition system. Securing the performance of fire doors is a very important aspect. However, there is a concern that old fire doors may not function normally in the event of fire due to natural deterioration, corrosion, and damage during the use process, but countermeasures are insufficient. Therefore, from a management perspective, it is very important to maintain fire doors and secure an appropriate replacement time. Therefore, the purpose of this study is to determine whether the fire door has durability to prevent fire spread in the process of use through operation probability analysis and expert surveys, and to propose an appropriate useful life of the fire door.

  • PDF

A Study on Factors Affecting Formation of Social Capital for Volunteer Fire Brigade (의용소방대의 사회적 자본 영향요인 분석)

  • Woo, Seong-Cheon;Chae, Jin;Go, Gi-Bong
    • Fire Science and Engineering
    • /
    • v.28 no.1
    • /
    • pp.64-70
    • /
    • 2014
  • A Volunteer Fire Brigade is a voluntary social services organization that performs various assistance works in fire fighting activities such as fire fighting and rescue of human lives on a part-time basis. Recently, it has also assumed an important role in the creation of security culture of local society. Besides, it provides diverse service activities related to security of local society. However, as this kind of volunteer fire brigade organization is not in a vigorous state, research for an improvement is being carried out in earnest. As part of a vitalization plan of the volunteer fire brigade, an attempt was made in this research to present an activation plan of the volunteer fire brigade through formation of social capital. Accordingly, efforts were made in this research to investigate and analyze an awareness of social capital among the volunteers and to present on this basis a plan for formation of social capital for the volunteer fire brigade of local society. As a result of the research, it turned out that social norm has the major effect on the formation of social capital for volunteer fire brigade. Therefore, it is our belief that an independent statute should be established to nurture and develop volunteer fire brigades. And when strong mutual trust among the volunteers are formed and efforts for devotion to local society are made on this basis, the security level of local society will be enhanced further.

A Study on Proposals for Improving the Fire Protection Regulations for Nuclear Power Plants (원자력발전소 화재방호 규제 개선 방향에 관한 연구)

  • Ma, Jin-Soo;Kwon, Kyung-Ok
    • Fire Science and Engineering
    • /
    • v.24 no.4
    • /
    • pp.116-122
    • /
    • 2010
  • The fire protection system of nuclear power plants shall be designed, constructed and operated, through a defense-in depth criterion to suppress the leakage of radioactivity to the outside and to allow the safety shutdown function when a fire occurs. In order to achieve these purposes, most of countries abroad operating the nuclear power plants keep up the integrated regulations, however we have two guidelines, the fire protection service act and the nuclear energy act, as mandatory requirements to apply to the fire protection systems in nuclear power plants. It has shown that USA, Canada and Japan which have long experience in operating nuclear power plants have regulations integrated technically for fire protection system of nuclear power plants. It is proposed that the things once verified the risk analysis of the fire hazard by the nuclear law in the design for fire suppression system in plants should be authorized by the fire protection service act as an exception.