• Title/Summary/Keyword: Korea Plateau

Search Result 305, Processing Time 0.023 seconds

Laboratory Tests of Chromium-51 Complexes for teak Detection in Pipes Carrying A Liquid Flow

  • Kim, You-Sun;Lee, Byung-Hyun
    • Nuclear Engineering and Technology
    • /
    • v.6 no.4
    • /
    • pp.231-237
    • /
    • 1974
  • For detection and localization of leaks in closed vessels or pipes carrying liquid flow, $^{51}$ Cr-EDTA and $^{51}$ Cr-DTPA were synthesized and, the column and batch equilibrium experiments were carried out. In the column experiment, the recovery of $^{51}$ Cr-EDTA is 100% in quartz sand and 80.9% in steel sawdust, and that of $^{51}$ Cr-DTPA is 77.4% in quartz sand and 6.4% in steel sawdust. The recovery curve. $^{51}$ Cr-DTPA system in steel sawdust does not show a certain plateau, exceptionally. In general, $^{51}$ Cr-EDTA is adsorbed less than $^{51}$ Cr-DTPA. In the batch equilibrium experiment, the distribution coefficients (Kd) and effect of pH were investigated by using quartz sand, montmorillonite, steel sawdust, and mixed cement raw material as media. In general, the Kd values for $^{51}$ Cr-EDTA are lower than that of $^{51}$ Cr-DTPA. The Kd values for $^{51}$ Cr-EDTA are almost zero at pH 6.0, 7.0, and 8.0.

  • PDF

Study on the Hydrogenation Properties of MmNi4.5Mn0.5Zrx(x=0, 0.025, 0.05, 0.1) Alloys Containing the Zr by Excess (과잉의 Zr을 첨가한 MmNi4.5Mn0.5Zrx(x=0, 0.025, 0.05, 0.1) 합금의 수소화특성에 관한 연구)

  • Kang, Kil-Ku;Park, Sung-Gap;Kang, Sei-Sun;Kwon, Ho-Young
    • Korean Journal of Materials Research
    • /
    • v.12 no.8
    • /
    • pp.617-623
    • /
    • 2002
  • In order to improve the hydrogen storage capacity and the activation properties of the hydrogen storage alloys, the rare-earth metal alloy series, $MmNi_{ 4.5}$$Mn_{0.5}$ $Zr_{x}$ (x=0, 0.025, 0.05, 0.1), are prepared by adding the excess Zr in $MmNi_{4.5}$ $Mn_{0.5}$ / alloy for the strong resistance to intrinsic degradation. The hydrogen storage alloys of rare-earth metal such as $LaNi_{5}$ , and $MmNi_{5}$X and $MmNi_{4.5}$ /$_Mn{0.5}$ alloys which substituted La by misch metal properties were characterized as well. The hydrogen storage alloys were produced by melting each metal mixture in arc melting furnace, and the as-cast alloys were heat-treated at $1100^{\circ}C$ for 10 hr. The major elements of misch metal(Mm) were La, Ce, Pr and Nd with some impurities less than 1wt.% determined by ICP-AES. X-ray diffraction indicated that the structure for these samples was a single phase of hexagonal with $CaCu^{5}$ type. As the Zr contents increases, the activation time and the plateau pressure decrease and sloping of the plateau pressure increase. Amount of the 2nd phases increases with increase in Zr contents in $MmNi_{ 4.5}$$Mn_{0.5}$ $Zr_{0.1}$ alloy, This phenomenon indicated that $ZrNi_3$ in this phase, which shows the maximum storage capacity and the strong resistance to intrinsic degradation, is considered as a proper alloy for hydrogen storage..

Identification of Limiting Amino Acids and Determination of Requirement of Total Sulfur-containing Amino Acids in a Low Protein Diet in Young Chicks. (어린병아리에서 저단백질사료내 제한아미노산의 규명과 함유황아미노산의 요구량 결정)

  • Chee, Kew-Mahn
    • Korean Journal of Poultry Science
    • /
    • v.11 no.1
    • /
    • pp.1-12
    • /
    • 1984
  • Since a 13% dietary protein level is generally accepted as a standard in evaluating net protein utilization values of protein sources in chicks, limiting amino acids a 13% protein basal diet containing 15% isolated soy-protein as the only source of dietary protein, were identified. Of such amino acids as methionine, lysine, threonine and tryptophan added to the basal diet singly or as a combination, methionine appeared as the only limiting amino acid for optimum growth of the chicks. When the requirement of total sulfur-containing acids (TSAA) was estimated as the point at which the dose-response curve intersected a line representing the plateau for maximum performance, the TSAA requirements for maximum growth and feed intake were 4.73% and 3.73% of dietary protein, respectively. The values, expressed in terms of TSAA intake, required for maximum weight gain, feed intake and gain/feed ratio were 167.1, 136.8 and 159.1 mg/bird/day, respectively.

  • PDF

Theoretical Basis and Application of the Neurac Technique Which Uses the Sling Exercise Therapy (슬링운동치료를 이 용한 Neurac 기법의 이론적 근거와 적용방법)

  • Kim, Suhn-Yeop;Kim, Taek-Yean
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.12 no.2
    • /
    • pp.52-65
    • /
    • 2006
  • Sling exercises therapy can speak as appliable comprehensive exercises therapy technique efficiently in general exercise field for injured worker's rehabilitation process and health improvement patient or athlete, injury or disease that have pain or dysfunction to neuromuscular system using that shake. At 1990 an early stage, because physical therapist and doctors of medical treatment developed country norway of north europe cooperate sling exercises therapy's concept trend spreading worldwide establishing theory newly based on scientific basic be. Musculoskeletal system, old man and young child's nervous system injurer's treatment and exercise and industry worker's rehabilitation process, athlete's rehabilitation etc. several fields introduced in early 2000s to Korea apply. Sling exercises therapy neuromuscular system disease continuous abatement as general concept of active exercise and treatment that use sling exercises equipment by purpose know can. This review article wishes to introduce about neuromuscular activation, "Neurac" technique that can speak as step developed more concept based on application principle etc, of basic sling exercises effort's change by suspension point's change that is concept, stability exercises principle, open kinetic chain exercises and closed kinetic chain exercises. Arranged about Plateau potential's characteristic and working mechanism and Neurac technique's application method that can say as Neurac technique's neuro-physiologic base, and presented treatment method of lumbar part disease and cervical part, shoulder joint part disease to application example. Because plateau potential forward player that induce using Neurac technique in part muscles that act role that keep spine surrounding stability in this article keeps muscle's contraction continuously, between global and local muscles, presented several study findings that can cause affirmative change in insufficient muscle adjustment state such as imbalance of muscles' action order. Expect that case studies that use this Neurac technique here after consist continuously.

  • PDF

Effects of the Addition of Mn and $AB_5$ Type Alloy on the Electrochemical Characteristics of Ti-Cr-V BCC Type Alloys (BCC계 Ti-Cr-V 합금의 전기화학적 특성에 미치는 Mn 및 $AB_5$계 합금 첨가 효과)

  • Kim, J.Y.;You, J.H.;Park, C.N.;Park, C.J.;Choi, J.;Cho, S.W.
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.18 no.1
    • /
    • pp.52-59
    • /
    • 2007
  • We investigated the effects of the addition of Mn and $AB_5$ type alloy on the electrochemical characteristics of Ti-Cr-V BCC type alloys as anode materials for Ni-MH battery. The activation behavior and discharge capacity of the BCC type alloys were significantly improved by ball-milling with the $LmNi_{4.1}Al_{0.25}Mn_{0.3}Co_{0.65}$ alloy, because the $AB_5$ type alloy acted as hydrogen path on the surface of the BCC type alloy. Among the Mn substituted alloys($Mn=0.03%{\sim}0.08%$), the $Ti_{0.32}Cr_{0.38}Mn_{0.05}V_{0.25}$ alloy ball-milled with $AB_5$ type alloy exhibited the greatest discharge capacity of $336\;mAh{\cdot}g^{-1}$. In addition, Mn substituted alloys exhibited the lower plateau pressure in P-C- T curve, the better hydrogen storage capacity and faster surface activation compared with the alloy without Mn.

Comparison of Topex/Poseidon sea levels data and Tide Gause sea levels data from the South Indian Ocean (남인도양에서의 해수면에 대한 위성자료(Topex/Poseidon 고도계)와 현장자료(Tide Gauge 해면계)간의 비교)

  • 윤홍주;김상우;이문옥;박일흠
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.10a
    • /
    • pp.281-285
    • /
    • 2001
  • According to standard procedures as defined in the users handbook for sea level data processes, I was compared to Topex/poseidon sea level data from the first 350days of mission and Tide Gauge sea level data from the Amsterdam- Crozet- Kerguelen region in the South Indian Ocean. The comparison improves significantly when many factors for the corrections were removed, then only the aliased oceanic tidal energy is removed by oceanic tide model in this period. Making the corrections and smoothing the sea level data over 60km along-track segments and the Tide Gauge sea level data for the time series results in the digital correlation and RMS difference between the two data of c=-0.12 and rms=11.4cm, c=0.55 and rms=5.38cm, and c=0.83 and rms=2.83cm for the Amsterdam, Crozet and Kerguelen plateau, respectively. It was also found that the Kerguelen plateau has a comparisons due to propagating signals(the baroclinic Rossby wave with velocity of -3.9~-4.2cm/sec, period of 167days and amplitude of 10cm) that introduce temporal lags($\tau$=10~30days) between the altimeter and tide gauge time series. The conclusion is that on timescales longer than about 10days the RMS sea level errors are less than or of the order of several centimeters and are mainly due to the effects of currents rather than the effects of sterics(water temperature, density) and winds.

  • PDF

Effects of Mold Temperatures on Physical Properites of Injection Molded Thermoplastic Polyurethanes (사출성형 열가소성 폴리우레탄의 물리적 성질에 미치는 금형 온도 영향)

  • Lee, Dai-Soo;Kim, Seong-Geun;Nguyen, Vinh-Khanh;Lee, Wing-Ji;Pang, Su-Jin
    • Elastomers and Composites
    • /
    • v.39 no.4
    • /
    • pp.286-293
    • /
    • 2004
  • Ester- and ether-based thermoplastic polyurethanes of different hardness were injection molded at different mold temperatures and effects of mold temperature on the physical properties of TPUs were investigated. Glass transition temperatures of soft segments of TPUs were hardly changed by mold temperatures. The phase separation of soft and hard segments of injection molded TPUs were affected little by mold temperatures. However, crystallinity of hard segments, temperature range of rubbery plateau, and tensile strength of injection molded TPUs decreased with increasing mold temperatures for TPUs of high hardness. However, injection molded TPUs of low hardness showed increases of crystallinity of hard segments, temperature range of rubbery plateau, and tensile strength with increasing mold temperatures. Different physical properties of injection molded TPUs depending on mold temperatures were attributed to different crystallization and physical crosslinking effects of hard segments.

Effects of reversing the coiling direction on the force-deflection characteristics of nickel-titanium closed-coil springs

  • Park, Hwan-Hyung;Jung, Suk-Hwan;Yoon, Juil;Jee, Kwang Koo;Han, Jun Hyun;Baek, Seung-Hak
    • The korean journal of orthodontics
    • /
    • v.49 no.4
    • /
    • pp.214-221
    • /
    • 2019
  • Objective: To investigate the effects of reversing the coiling direction of nickel-titanium closed-coil springs (NiTi-CCSs) on the force-deflection characteristics. Methods: The samples consisted of two commercially available conventional NiTi-CCS groups and two reverse-wound NiTi-CCS groups (Ormco-Conventional vs. Ormco-Reverse; GAC-Conventional vs. GAC-Reverse; n = 20 per group). The reverse-wound NiTi-CCSs were directly made from the corresponding conventional NiTi-CCSs by reversing the coiling direction. Tensile tests were performed for each group in a temperature-controlled acrylic chamber ($37{\pm}1^{\circ}C$). After measuring the force level, the range of the deactivation force plateau (DFP) and the amount of mechanical hysteresis (MH), statistical analyses were performed. Results: The Ormco-Reverse group exhibited a significant shift of the DFP end point toward the origin point (2.3 to 0.6 mm), an increase in the force level (1.2 to 1.3 N) and amount of MH (1.0 to 1.5 N) compared to the Ormco-Conventional group (all p < 0.001), which indicated that force could be constantly maintained until the end of the deactivation curve. In contrast, the GAC-Reverse group exhibited a significant shift of the DFP-end point away from the origin point (0.2 to 3.3 mm), a decrease in the force level (1.1 to 0.9 N) and amount of MH (0.6 to 0.4 N) compared to the GAC-Conventional group (all p < 0.001), which may hinder the maintenance of force until the end of the deactivation curve. Conclusions: The two commercially available NiTi-CCS groups exhibited different patterns of change in the force-deflection characteristics when the coiling direction was reversed.

Quench Characteristics of SSC Dipole Magnet Prototypes (SSC 쌍극자 마그네트의 퀜치 특성에 대한 연구)

  • Nah, Wan-Soo;Ryu, Kang-Sig;Kwon, Young-Kil;Cho, Jeon-Wook;Jin, Hong-Beom
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.1078-1080
    • /
    • 1993
  • The quench performance and ramp rate sensitivity of eighteen 5-cm-aperature, 15-m-long SSC dipole magnet prototypes are discussed. All the magnets appear to reach a quench plateau near their extrapolated short sample current limit and well in excess of the operating current with very little training. Most of the magnets, however, exibit a dramatic degradation of thier quench current as a function of ramp rate, which for the most part, can be attributed to large cable eddy currents.

  • PDF

Charge Transfer between STM Tip and Au(100) in Dry, H2O, and D2O Atmospheres

  • Utami, Anggi;Chung, Yonghwa;Lee, Chi-Woo
    • Journal of Electrochemical Science and Technology
    • /
    • v.4 no.4
    • /
    • pp.153-156
    • /
    • 2013
  • Charge transfer between STM tip and Au(100) has been investigated by using a Scanning Tunneling Microscopy (STM) technique in dry, $H_2O$, and $D_2O$ atmospheres. Dry atmosphere was indicated by humidity as low as 5 % and high humidity as high as 98% was managed by injecting $H_2O$ and $D_2O$ to the chamber. The current decayed more slowly in high humidity than in dry atmosphere. The plateau currents were found to appear at separations larger than ca. $5{\AA}$ where the current decay stopped depending on applied bias voltages. The polarity dependence was observed at the STM junction between Pt-Ir tip and the gold. On the contrary, little dependence was seen at the one between Au tip and the substrate electrode.