• Title/Summary/Keyword: Knife-edge

Search Result 96, Processing Time 0.025 seconds

Influence of ECC ductility on the diagonal tension behavior (shear capacity) of shear-wall panel (ECC (Engineered Cementitious Composite)의 연성이 전단벽의 사인장 거동에 미치는 영향)

  • Ha Gee-Joo;Shin Jong-Hack;Kim Yun Yong;Kim Jeong-Su;Kim Jin-Keun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05b
    • /
    • pp.321-324
    • /
    • 2005
  • This paper presents a preliminary study on the influence of material ductility on diagonal tension behavior of shear-wall panels. There have been a number of previous studies, which suggest that the use of high ductile material such as ECC (Engineered Cementitious Composite) significantly enhanced shear capacity of structural elements even without shear reinforcements involved. The present study emphasizes increased shear capacity of shear-wall panels by employing a unique strain-hardening ECC reinforced with poly(vinyl alcohol) (PVA) short random fibers. Normal concrete was adopted as the reference material. Experimental investigation was performed to assess the failure mode of shear-wall panels subjected to knife-edge loading. The results from experiments show that ECC panels exhibit a more ductile failure mode and higher shear capacity when compared to ordinary concrete panels. The superior ductility of ECC was clearly reflected by micro-crack development, suppressing the localized drastic fracture typically observed in concrete specimen. This enhanced structural performance indicates that the application of ECC for a in-filled frame panel can be effective in enhancing seismic resistance of an existing frame in service.

  • PDF

Response of low-temperature steel beams subjected to single and repeated lateral impacts

  • Truong, Dac Dung;Jung, Hae-Jung;Shin, Hyun Kyoung;Cho, Sang-Rai
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.10 no.6
    • /
    • pp.670-682
    • /
    • 2018
  • This paper presents the experimental and numerical investigation results of the response of low-temperature steel (LT-FH32 grade steel) beams under repeated impacts at room temperature and a single impact at a sub-zero temperature. After conducting tensile tests at room and sub-zero, repeated impact tests were conducted on two clamped single-beam models at room temperature, and single-impact tests of two other clamped single-beam models were conducted at $-50^{\circ}C$. The single and repeated impact tests were conducted by releasing a knife-edge striker using a drop testing machine. The permanent deflection of the model measured after each impact gradually increased with increasing number of impacts. Under the reduced temperature, the permanent deflection of the models slightly decreased. The numerical analyses were also performed to predict the damage response of the tested single-beam models. A comparison of the numerical prediction with those of experiments showed quite reasonable agreement.

Comparison of Liquid- and Vapor-Phase Spray Characteristics of E85 Fuel using Schlieren Visualization Technique (쉴리렌 가시화 기법을 이용한 E85 연료의 액상 및 기상 분무 비교)

  • Park, Suhan;Chang, Mengzhao
    • Journal of Institute of Convergence Technology
    • /
    • v.8 no.1
    • /
    • pp.9-13
    • /
    • 2018
  • The purpose of this study is to investigate the liquid- and vapor-phase spray characteristics, such as spray tip penetration and spray angle using gasoline direct injection (GDI) injector with multi-hole. The vapor-phase spray was captured by the Schlieren visualization system, which consists of high-speed camera, LED lamp, concave mirrors, and knife-edge. The liquid-phase spray was visualized by Mie-scattering techniques. Both spray images of vapor- and liquid-phase were visualized under 373 K of ambient temperature, 1 bar of ambient pressure, and 100/200 bar of injection pressure. The energizing duration was fixed at 1.5 ms. From the analysis of experimental results, it revealed that the increased injection pressure induced an early vaporization due to the improvement of droplet atomization. The spray tip penetration and spray angle in vapor-phase were higher than those in liquid-phase. The difference in the spray tip penetration between vapor- and liquid-spray gradually increased with the time elapsed after the injection. Even with the spray angle characteristics, it was found that the difference between the spray angle of liquid and vapor spray gradually grew after they entered steady-state conditions.

Millimeter-wave diffraction-loss model based on over-rooftop propagation measurements

  • Kim, Kyung-Won;Kim, Myung-Don;Lee, Juyul;Park, Jae-Joon;Yoon, Young Keun;Chong, Young Jun
    • ETRI Journal
    • /
    • v.42 no.6
    • /
    • pp.827-836
    • /
    • 2020
  • Measuring the diffraction loss for high frequencies, long distances, and large diffraction angles is difficult because of the high path loss. Securing a well-controlled environment to avoid reflected waves also makes long-range diffraction measurements challenging. Thus, the prediction of diffraction loss at millimeter-wave frequency bands relies on theoretical models, such as the knife-edge diffraction (KED) and geometrical theory of diffraction (GTD) models; however, these models produce different diffraction losses even under the same environment. Our observations revealed that the KED model underestimated the diffraction loss in a large Fresnel-Kirchhoff diffraction parameter environment. We collected power-delay profiles when millimeter waves propagated over a building rooftop at millimeter-wave frequency bands and calculated the diffraction losses from the measurements while eliminating the multipath effects. Comparisons between the measurements and the KED and GTD diffraction-loss models are shown. Based on the measurements, an approximation model is also proposed that provides a simple method for calculating the diffraction loss using geometrical parameters.

Optimal Path Search Algorithm for Urban Applying Received Signal Strength on Satellite Communication Environment (위성통신 환경에서 전파수신감도를 활용한 도심지 최적경로탐색 알고리즘)

  • Park, No-Uk;Kim, Joo-Seok;Lim, Joo-Yoeng;Lim, Tae-Hyuk;Yoo, Chang-Hyun;Kwon, Kun-Sup;Kim, Kyung-Seok
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.12 no.6
    • /
    • pp.189-197
    • /
    • 2012
  • In this paper, we propose an optimal path search algorithm that applies the received signal strength between a mobile device and a satellite. Because the common path search algorithm is only based on the shortest path search, it is difficult to provide stable multimedia services for the satellite mobile devices. The proposed algorithm provides the stable communication environment for the satellite mobile devices based on received signal strength. In Satellite communications, changes in the radio quality are severe depending on the receiving environment. Therefore, an accurate analysis of the receiving environment characteristics is very important for providing stable multimedia services of satellite communications. The causes of radio attenuation are atmosphere attenuation, vegetation attenuation and buildings attenuation. These factors were applied to analyze the received signal strength. The proposed algorithm can search the optimal path in urban for stable satellite multimedia services.

RADIOGRAPHIC STUDY OF PERI-IMPLANT BONE LOSS AND ITS RELATIONSHIP TO THE MORPHOLOGY ON MAXILLARY ANTERIOR ALVEOLAR RIDGE (임플란트주위골 흡수 및 상악전치부 치조제 형태와의 관계에 대한 방사선학적 연구)

  • Lee, Jun-Hee;Hong, Jong-Rak;Kim, Chang-Soo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.32 no.6
    • /
    • pp.575-579
    • /
    • 2006
  • Purpose : The purpose of this study was to evaluate peri-implant bone loss and implant success on anterior maxillary alveolar ridges and Compare Class III and Class IV ridges in the aspect of peri-implant bone loss. Material and Methods : 14 patients (aged 21 to 68, 6males and 8females), who lacked maxillary anterior teeth and were installed from January 2000 to April 2003 at Samsung Medical Center, were selected. The type of implant used included 30 $Br\ddot{a}nemark$ implant. They were taken with digital tomographic and conventional intraoral radiographic examinmation, and were treated with implant installaion without bone augmentation. The peri-implant bone resorption was measured at the mesial and distal aspect of implant on the conventional intraoral radiographs. Results : The study classified the anterior maxillary alveolar ridge and measured peri-implant bone resorption from the period of implant installation to the 2nd year after functional loading radiographically. The study revealed no statistically significant difference between two groups, which was classified by its morphology. The average bone resorption on healing period before loading was 0.18mm and 0.18mm, the 1st year of loading period, 0.77 mm and 0.84mm, and on the 2nd year of loading period, 0.07mm and 0.06mm, respectively on both Class III and class IV. Conclusion : In the knife edge form of anterior maxillary residual ridges(Class IV), implant placement without ridge augmentation does not have significant difference with that of Class III alveolar ridge in the concern of Implant success after 2 year functional loading period in the aspect of peri-implant bone resorption radiographically.

AN EXPERIMENTAL STUDY ON THE MARGINAL LEAKAGE ACCORDING TO THE FILLING METHOD OF THE ESTHETIC MATERIALS IN CLASS V CAVITIES (V급 와동에서 심미성 수복재의 충전 방법에 따른 변연누출에 관한 실험적 연구)

  • Park, Jin-Young;Cho, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.15 no.1
    • /
    • pp.217-227
    • /
    • 1990
  • The purpose of this study was to evaluate the marginal leakage of esthetic restorative materials according to the filling method in class V cavities. 60 cavities were prepared on buccal surface for dye penetration test and divided into 5 experimental groups according to the filling methods of esthetic materials: group 1 was filled with glass ionomer cement, group 2, 3 and 4 were filled with the chamfer, knife edge and butt joint shaped glass ionomer cement respectively and silux plus/scotchbond 2$^{(R)}$ by sandwich technique, group 5 was lined with Dycal$^{(R)}$ and filled with silux plus/scotchbond 2$^{(R)}$ by bulk filling technique. All the specimens were then thermocycled in a range of $4^{\circ}C-60^{\circ}C$ by and immersed in 2% methylene blue dye solution for 24 hours, and sectioned mesiodistally with carborundum disk into two parts under water spray. All the specimens were observed at the occlusal and gingival margins and statistical analysis was performed. The obtained results were as follows : 1. At the occlusal margins, group 2, 3, 4 and 5 showed less marginal leakage than group 1 (p<0.05) and there were not significant differences among group 2, 3, 4, and 5. 2. At the gingival margins, group 5 showed the least marginal leakage and group 4 and 5 showed less marginal leakage than group 1, 2 and 3 (p<0.05). 3. In the laminated groups, group 4 showed less marginal leakage than group 2 and 3 at the gingival margins. 4. In comparison to the occlusal and gingival margins, all groups showed less marginal leakage at the occlusal margins than at the gingival margins (p<0.05).

  • PDF

The Influence of [Mn/S] Ratios on the Fracture Morphology of a Heavy-section Steel Castings at Elevated Temperature (대형주강의 고온파단형태에 미치는 [Mn/S]비의 영향)

  • Kim, Sung-Gyoo;Kim, Ji-Tae;Park, Bong-Gyu;Park, Heung-Il
    • Journal of Korea Foundry Society
    • /
    • v.34 no.5
    • /
    • pp.170-178
    • /
    • 2014
  • Using the Gleeble test, the effects of [Mn/S] ratios and the presence of sulfides on the high-temperature fracture morphology of heavy-section steel castings were analysed via the observations of the microstructures. The specimens for which the [Mn/S] ratio was in the range of 60~80 showed a ductile fracture morphology with an area reduction of more than 60%, while some specimens with similar [Mn/S] ratios showed a brittle fracture morphology with an area reduction of 0.0% due to the liquidation of sulfides at the grain boundary. The fracture morphology was classified into three types in the Gleeble high-temperature tensile test specimens. The first type showed dimple formation at the grain boundary, the formation of globular MnS sulfides, and plastic deformation of sulfides at an elevated temperature, indicating a needle-point type of ductile fracture with area reductions of 96.0~97.8%. The second type was a knife-edge type brittle fracture with an area reduction of 0.0% due to the film-type liquidation of sulfides at the grain boundary, band-type liquidation, and the liquidation of a terraced nipple pattern. The third type was the typical ductile fracture with an area reduction of 31.3~81.0%, in accordance with the mixture of dimples with in the grains and terraced nipple pattern at the grain boundary.

Status of Facilities, Equipment, and Environmental Hygiene Management of School Foodservices in Daiyue-district, Taian-city, China (중국 태안시 다이웨구 학교급식소의 시설·기구·환경 위생관리 실태)

  • Cheng, Xiao Xia;Moon, Hye-Kyung
    • Journal of the FoodService Safety
    • /
    • v.2 no.2
    • /
    • pp.59-66
    • /
    • 2021
  • The results of the inspection based on the sanitation checklist and the measurement of refrigerator/freezer temperature, illuminance, and ATP were conducted at 12 school foodservices in Daiyue-district, Taian-city, Shandong Province, China, at the same time, and the results were as follows. Five items of 'Use sterilized cutting boards', 'Use sterilized knives', 'Use worktable after sterilization', 'Use sink after sterilization', 'Sterilize the interior/exterior of the refrigerator regularly' in the checklist inspection were found not to be performed (0%). Two items of 'Disinfect hands after washing', 'Equipped with hand sterilizer' and 'Sterilize the kitchen areas regularly' were investigated as being performed only in one foodservice (8%). The average illuminance of the receiving stand were 373.08±106.35 Lux, 8% when the standard (540 Lux or higher) was complied with, the average refrigerator temperature were 7.06±0.82℃, 38.9% when the standard (-2 to 5℃) was observed 8% of cases complying with the standard (below -18℃) at -8.56±0.76℃ were investigated. As a result of ATP measurement, the surfaces of knife edge, cutting board, refrigerator door handle, worktable, and sink, which are not sterilized at all, were not suitable (accept ratio 0%), sterilized food plate (accept ratio 54.2%) and utensil for preserved food (accept ratio 75%) had a relatively high accept ratio. China's hygiene regulations should be revised in the direction of strengthening disinfection practices for facilities, equipment, and the environment, and hygiene measures such as education on disinfection and preparation of economical disinfection methods should be established.

Punching System for Plastic Mulching at Soybean Field - Effect of Punching Knife Shape on the Cutting Performance (비닐 천공 시스템 개발 - 칼날 형상이 천공 성능에 미치는 영향)

  • Hong, Sungha;Choi, Ahnryul;Lee, Kyouseung
    • Journal of agriculture & life science
    • /
    • v.50 no.5
    • /
    • pp.217-224
    • /
    • 2016
  • In this study, performance of a developed automatic punching machine considering the planting density of soybeans was evaluated in the case of the operation speed of 0.18-0.28 m/s. The performance demonstrated a rate of 320-500 ㎡/h, 260-400 ㎡/h, and 210-330 ㎡/h for the 0.20 m, 0.25 m, and 0.30 m soybean planting density, respectively. One hundred percent punching capacity was confirmed in 30 mm distance between the ground and the blade. Additionally, in the 50 mm distance condition, the performance of round, square, and hexagonal blades were observed in the range of 16.7-25.2%, 33.0-42.3%, and 54.5-100.0%, respectively. Above all, the hexagonal blade with a 60° edge angle had the most superior cutting quality demonstrating a smooth and soft cutting plane of the plastic.