• Title/Summary/Keyword: Knife

Search Result 654, Processing Time 0.027 seconds

Efficacy and Safety of ClearCutTM Knife H-type in Endoscopic Submucosal Dissection for Gastric Neoplasms: A Multicenter, Randomized Trial

  • Eun Jeong Gong;Hyun Lim;Sang Jin Lee;Do Hoon Kim
    • Journal of Gastric Cancer
    • /
    • v.23 no.3
    • /
    • pp.451-461
    • /
    • 2023
  • Purpose: Endoscopic submucosal dissection (ESD) is an effective treatment for early gastrointestinal neoplasms. However, this is a time-consuming procedure requiring various devices. This study aimed to evaluate the efficacy and safety of the ClearCutTM Knife H-type, which is an integrated needle-tipped and insulated-tipped (IT) knife. Materials and Methods: Between July 2020 and September 2021, 99 patients with gastric epithelial neoplasms scheduled for ESD at three tertiary care hospitals were randomly assigned to H-knife (ClearCutTM Knife H-type) or IT-knife (conventional IT knife) groups. Procedure times, therapeutic outcomes, and adverse events were analyzed. Results: A total of 98 patients (50 in the H-knife group and 48 in the IT-knife group) were analyzed. The median total procedure time was 11.9 minutes (range, 4.4-47.2 minutes) in the H-knife group and 12.7 minutes (range, 5.2-137.7 minutes) in the IT-knife group (P=0.209). Unlike the IT-knife group, which required additional devices in all cases, no additional devices were used in the H-knife group (P<0.001). En-bloc resection was performed for all lesions in both groups. The incidence of adverse events was not significantly different between groups (4.0% in the H-knife group vs. 8.3% in the IT-knife group; P=0.431). Conclusions: The newly developed hybrid device, the ClearCutTM Knife H-type, had comparable efficacy to the conventional IT knife for gastric ESD.

Development of Gap Measuring System Between Strip and Air Knife in Continuous Galvanizing Line

  • Lee, Jang-Myung;Ryu, Young-Kee
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.53.5-53
    • /
    • 2001
  • In continuous galvanizing process at steel making plant, coating weight on the surface of strip that pass through air knife is controlled by the pressure at the chamber of air knife and the gap between the nozzle of air knife and strip. The pressure can be easily measured and controlled. But it is difficult to measure the distance between Air knife nozzle and strip, and also difficult to decide how much distance air knife move. Because, the gap between nozzle and strip varies with the height of air knife, intermesh of stabilizing roll and welding of strips that have different thickness. In this research, we developed a gap sensor that can measure the relative distance between Air knife nozzle and strip. And several tests are performed to find optimal condition for application at real plant. We performed test in which the possibility of the sensor to apply ...

  • PDF

Effects of Cutting Methods on Qualities of Fresh-Cut Apples and Leafy Vegetables (절단방법이 신선절단 사과와 엽채류의 품질에 미치는 영향)

  • Chung, Hun-Sik;Jeong, Moon-Cheol;Moon, Kwang-Deog
    • Food Science and Preservation
    • /
    • v.19 no.2
    • /
    • pp.173-177
    • /
    • 2012
  • Whole apples were cut with a sharp or dull knife, and whole cabbages and crisp lettuce heads were cut into salad or thin strips with a knife or by hand. The fresh-cut apples, cabbages, and lettuce were packed in low-density polyethylene bags and kept at $4^{\circ}C$, and their qualities were investigated. Browning and softening of the apples that were cut with a sharp knife were more delayed than those of the apples that were cut with a dull knife. The soluble solids and pH of the fresh-cut apples were not affected by the sharpness of the cutting blade. The browning indexes of the fresh-cut cabbages and lettuce were significantly lower in the samples that were cut with a knife than by hand and in the samples that were cut into large pieces. The results suggest that the cutting blade sharpness, cutting tools, and cut types affected the quality of the fresh-cut apples and leafy vegetables, and that the cutting methods which minimized the cutting damage should be used to retard the browning and softening of the produce.

Biomechanics of stabbing knife attack for trauma surgeons in Korea: a narrative review

  • Kun Hwang;Chan Yong Park
    • Journal of Trauma and Injury
    • /
    • v.37 no.1
    • /
    • pp.1-5
    • /
    • 2024
  • The aim of this paper was to review the biomechanics of knife injuries, including those that occur during stabbing rampages. In knife stab attacks, axial force and energy were found to be 1,885 N and 69 J, respectively. The mean velocity of a stabbing motion has been reported to range from 5 to 10 m/sec, with knife motions occurring between 0.62 and 1.07 seconds. This speed appears to surpass the defensive capabilities of unarmed, ordinarily trained law enforcement officers. Therefore, it is advisable to maintain a minimum distance of more than an arm's length from an individual visibly armed with a knife. In training for knife defense, particularly in preparation for close-quarter knife attacks, this timing should be kept in mind. Self-inflicted stab wounds exhibited a higher proportion of wounds to the neck and abdomen than assault wounds. Injuries from assault wounds presented a higher Injury Severity Score, but more procedures were performed on self-inflicted stab wounds. Wound characteristics are not different between nonsuicidal self-injury and suicidal self-wrist cutting injuries. Consequently, trauma surgeons cannot determine a patient's suicidal intent based solely on the characteristics of the wound. In Korea, percent of usage of lethal weapon is increasing. In violence as well as murders, the most frequently used weapon is knife. In the crimes using knife, 4.8% of victims are killed. Therefore, the provision of prehospital care by an emergency medical technician is crucial.

Validation of Gamma Knife Perfexion Dose Profile Distribution by a Modified Variable Ellipsoid Modeling Technique

  • Hur, Beong Ik;Jin, Seong Jin;Kim, Gyeong Rip;Kwak, Jong Hyeok;Kim, Young Ha;Lee, Sang Weon;Sung, Soon Ki
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.1
    • /
    • pp.13-22
    • /
    • 2021
  • Objective : High precision and accuracy are expected in gamma knife radiosurgery treatment. Because of the requirement of clinically applying complex radiation and dose gradients together with a rapid radiation decline, a dedicated quality assurance program is required to maintain the radiation dosimetry and geometric accuracy and to reduce all associated risk factors. This study investigates the validity of Leksell Gamma plan (LGP)10.1.1 system of 5th generation Gamma Knife Perfexion as modified variable ellipsoid modeling technique (VEMT) method. Methods : To verify LGP10.1.1 system, we compare the treatment plan program system of the Gamma Knife Perfexion, that is, the LGP, with the calculated value of the proposed modified VEMT program. To verify a modified VEMT method, we compare the distributions of the dose of Gamma Knife Perfexion measured by Gafchromic EBT3 and EBT-XD films. For verification, the center of an 80 mm radius solid water phantom is placed in the center of all sectors positioned at 16 mm, 4 mm and 8 mm; that is, the dose distribution is similar to the method used in the x, y, and z directions by the VEMT. The dose distribution in the axial direction is compared and analyzed based on Full-Width-of-Half-Maximum (FWHM) evaluation. Results : The dose profile distribution was evaluated by FWHM, and it showed an average difference of 0.104 mm for the LGP value and 0.130 mm for the EBT-XD film. Conclusion : The modified VEMT yielded consistent results in the two processes. The use of the modified VEMT as a verification tool can enable the system to stably test and operate the Gamma Knife Perfexion treatment planning system.

Estimation on Formability of ]Knife Press Forming Process for the Thick Pipes (Knife Press Forming 공정의 후육관 성형성 예측)

  • Park, J.W.;Noh, H.G.;Ku, T.W.;Kang, B.S.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2009.10a
    • /
    • pp.319-322
    • /
    • 2009
  • Roll bending process has been used for manufacturing the pipes. However, it is not suitable process for the thick pipes. Knife press forming is acceptable process for the thick pipes. Recently, the knife press forming process using brake bending press have been performed. In this study, the estimation on formability of knife press forming process for the thick pipes is carried out. From the results, it is ensured that the thick pipes could be obtained by the knife press forming process.

  • PDF

Evaluation of the Accuracy of the CyberKnife

  • Jang, Ji-Sun;Kang, Young-Nam;Choi, Byung-Ock;Choi, Ihl-Bohng;Kim, Moon-Chan;Shin, Dong-Oh;Shin, Dong-Ho;Cho, Kwang-Hwan;Min, Chul-Kee;Kwon, Soo-Il
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2006.08a
    • /
    • pp.119-119
    • /
    • 2006
  • PDF

Extracorporeal High Intensity Focused Ultrasound Therapy (체외강력집속초음파치료)

  • Han, Sang-Suk
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.11 no.1
    • /
    • pp.17-24
    • /
    • 2005
  • Local treatment for tumors has developed from extended radical surgery to function preserving surgery on the basis of modern biology. With the development of minimally invasive technique, it changed to be minimal-invasive surgery. And nowadays technical revolution made non-invasive surgery possible with appearance of several kinds of non-surgical knives such as gamma knife, cyber knife, and HIFU (high intensity focused ultrasound) knife. In this article, history, HIFU machine and treatment procedure, histological change and its mechanism, clinical applications, advantage, disadvantage, and future prospect of extracorporeal high intensity focused ultrasound therapy using HIFU knife will be reviewed.

  • PDF

The effect of wear on the damage of slitting knife (Slitting Knife의 손상에 미치는 마모의 영향)

  • Nam, Ki-Woo;Kim, Cheol-Soo;Ahn, Seok-Hwan
    • Journal of Power System Engineering
    • /
    • v.20 no.4
    • /
    • pp.5-11
    • /
    • 2016
  • This study analyzed the damage to a slitting knife after cutting steel sheets. Damages to the structure were observed and wear tests were conducted. In addition, the degradation on the damaged and undamaged parts was compared with a micro Vickers hardness test. Weibull statistical analysis was carried out in order to evaluate the reliability of the micro Vickers hardness measured data. Spalling of the edge portion occurred by degradation during use over a long period. Rough parts in the specimens were caused by damage because the slitting knife was used for 1 year. The friction coefficient and wear loss at the damaged parts of the knife edge were slightly larger from shock due to repetitive cutting operation. The micro Vickers hardness followed a two-parameter Weibull probability distribution.

Frequency Controllable Ultrasonic knife and made by multi-layered PZT ultrasonic transducer (다층 압전진동자를 이용한 주파수 가변 초음파 메스의 개발)

  • 김무준;하강열
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.506-512
    • /
    • 1997
  • Ultrasonic knives have been successfully used for the surgery of many medical fields. However, the conventional ultrasonic knives for surgical operation cannot be controlled its resonant frequency. So if the material to cut has different characteristic impedance then different ultrasonic knife will be needed. Because the optimum driving frequency of ultrasonic knife is different by characteristic impedance of material. In this work, using a frequency variable ultrasonic transducer made of multi-layered PZT vibrator, a frequency controllable ultrasonic knife will be suggested. The design and computation principles will be also derived. For this work, firstly, the characteristics of this ultrasonic knife will be analyzed by transmission line model equivalent circuit, and the free admittance characteristics and vibrational velocity distributions will be obtained. Secondly, we will design and make the frequency controllable electrical oscillator for driving this ultrasonic knife.

  • PDF