• Title/Summary/Keyword: Kitchen fire

Search Result 36, Processing Time 0.022 seconds

The Proposal of Installations Standards for Commercial Kitchen Automatic Fire System (상업용 주방자동소화장치 도입과 설치기준 제안)

  • Lee, Changwoo;Kang, Dowoo;Oh, Seungju;Ham, Eungu;Cho, Yongsun
    • Journal of the Society of Disaster Information
    • /
    • v.12 no.1
    • /
    • pp.89-97
    • /
    • 2016
  • According to the statistics released by Ministry of Public Safety and Security, the number of restaurant fires in Korea reached around 2,400 and 169 damages of human life and damages to property was approximately over $8.8 billion for recent 3 years. It could be desirable having automatic commercial fire-extinguishing equipment at commercial facilities excluding housing facilities for the safety, applying at the place first where it has been more risky and expected fire can be occurred relatively because economical burden can be accelerated. In order to do this, adjust its level to meet the same level of the kitchen for 'Specific Target for Fire Fighting' that "gas leak alarm" has be equipped relevant regulations and it is considered and reasonable to expand the limit of application gradually.

A Full-scale Fire Test of an Apartment House (공동주택 실물화재 실험)

  • Kim, Myung-Bae;Han, Yong-Shik;Choi, Byung-Il;Do, Kyu-Hyung
    • Fire Science and Engineering
    • /
    • v.23 no.4
    • /
    • pp.104-111
    • /
    • 2009
  • To research about the fire spread in Korean apartment house, a full-scale fire test in a four-story apartment was executed. The fire started at the third floor, and originated from overheated cooking oil in the kitchen. The apartment included all combustibles in general house. Through measuring temperature, measuring the concentration of oxygen and observing, we investigated the fire spread inside the apartment house. As a result, we got the data of the time needed for the initiation of fire, the time for fire to spread into each area in the house, and the time required until flash-over was seen. Also we grasped the understanding of the fire spread to the upper floor.

Application Plan of Exhaust Systems in Strengthening Evacuation Safety in Apartment Houses (공동주택의 피난안전성 강화를 위한 배기시스템 활용 방안 연구)

  • Lee, Hyun-Sang;Yoon, Myung-Oh;Lee, Young-Ju;Kim, Jeong-Joon
    • Fire Science and Engineering
    • /
    • v.34 no.3
    • /
    • pp.49-57
    • /
    • 2020
  • Apartment buildings are becoming taller and more densely populated with the advancements in science and the development of cities, Consequently, various amenities and safety facilities are being developed to improve the quality of life for residents. However, according to statistics, the number of casualties in apartments accounts for a high proportion of accidents, and the leading cause of the casualties is smoke emitted from fires while sleeping at night. Although it is best to install separate indoor facilities in apartments to minimize smoke damages to occupants, it is useful to minimize the smoke damages by utilizing the installed facilities while reducing the financial burden of occupants. Based on the review, the heat exchanger ventilation system and the kitchen collective exhaust system were selected, and the feasibility of these systems was verified through fire simulation. From the verification results, the available safe egress time improved by 27, 30, and 35 s on the 25th, 35th, 50th floors, respectively.

A Study of the Ondol (Gudul, Floor Heating System) and Kitchen Space in the Traditional Houses on Jeju Island, Korea

  • Kim, Bong-Ae;Lee, Jeong-Lim
    • International Journal of Human Ecology
    • /
    • v.4 no.1
    • /
    • pp.15-23
    • /
    • 2003
  • Jeju-do is a volcanic island located off the shore of the Korean peninsula facing the Pacific Ocean. The traditional housing styles of the Jeju Province, therefore, reflect the impact of these natural backgrounds and reveal different housing styles that are distinctive from those of mainland Korea. The purpose of this research is to analyze the peculiarities of the Ondol (floor heating system) and the kitchen space of traditional housing of Jeju Island in terms of lifestyles. This study shall employ two research methods: a literature review and field survey methods. The literature review shall focus on the observations of characteristics noted in previous studies of Jeju's private houses. The field survey shall employ field survey and interview methods originating from the ethnography of the culturological-anthropologist approach. (1) The Jeju-do Ondol system is a “Weibang-eudul” system which means one Gudul per fire hole. (2) The definition of terms for Gulmook show variations depending on the various regions on Jeiu-do. (3) Major facilities in Jeongji include Gulmook, Sotduck, and Busup. Gulmook is a heating facility and Sotduck refers to a cooking facility; Busup refers to a combination of heating, cooking, and illuminating facilities.

Exhaust Characteristics of Kitchen Hood System with Inclined Air Curtain (에어커튼형 주방 레인지후드의 배기 특성)

  • Sung, Sun-Kyung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.12
    • /
    • pp.594-599
    • /
    • 2014
  • There have been many cases that the air curtain installed in the apartment can not well remove the gases such as carbon dioxide and particles such as smokes, oils and vapors generated during the cooking to disperse the pollutants into the room. This study uses the numerical analysis to show how the pollutant-removing performance of the range hood is changed when the air curtain is installed on the range hood of kitchen. As a result of the study, it turned out that, when the air amount supplied by air curtain through the slot was about 60% of exhaust amount, the capturing efficiency of range hood for pollutants increased by 70~80% more than the case without the air curtain. Even when the exhaust amount was small, the capturing efficiency was improved a lot with the use of air curtain. In case that the air flow velocity of slot was greater than 2 m/s, the capturing efficiency turned out to decrease.

Fire Extinguishing Capability of an Automatic Spreading Fire Extinguisher in Accordance with Horizontal Distance from a Fire Source (자동확산소화장치의 이격거리에 따른 소화성능평가연구)

  • Kwark, Ji-Hyun;Kim, Dong-Suk;Ku, Jae-Hyun
    • Fire Science and Engineering
    • /
    • v.27 no.5
    • /
    • pp.38-43
    • /
    • 2013
  • An automatic spreading fire extinguisher usually installed in a closed area like a boiler room, a laundry store or a restaurant's kitchen room is one of the fire protection equipments. This extinguisher automatically discharges dry powder, extinguishing fire. As this extinguisher has the extinguishing capability applicable to the nominal protection area, objects outside the area cannot be properly extinguished. However only its number is being requested according to the floor area in the related laws, and the extinguishing capability depends on the distance from a fire source. In this study we tried to investigate the extinguishing capability of the automatic spreading fire extinguisher in accordance with horizontal separation distance from a fire source. It appeared that the maximum horizontal separation distance was about 30 cm for both class A and B fire to be certainly extinguished.

Comparative Study on the Estimation Method of Fire Load for Residential Combustibles (주거공간 가연물의 화재하중 산정방법의 비교연구)

  • Choi, Su-Young;Kim, Jung-Yong;Nam, Dong-Gun;Kim, Sung-Chan
    • Fire Science and Engineering
    • /
    • v.27 no.6
    • /
    • pp.38-43
    • /
    • 2013
  • As a preliminary study to evaluate the reliability of the calculation method of fire load for residential furniture combustibles, the present study estimates the fire load considering the volume data obtained by the 3D geometrical information of combustibles and material properties based on the literature survey and sample burning test. A kitchen sink cabinet, couch and workstation were investigated for estimating its fire load and real fire test have been performed to measure total energy released from the combustibles. Based on total energy measured from real fire test, the relative error of the estimated fire load due to literature survey and measured material properties showed 6~120% and less than 20%, respectively. It shows that the estimation error of fire load are greatly affected by its material properties as well as geometrical information of combustibles and the present study will be able to contribute to accurate estimation of fire load.

A Study on the condition of Indoor environmental safety in kindergarten (유아교육기관의 실내 환경 안전 실태에 관한 연구)

  • Choi, Eun-Jin;Han, Hae-Ryon
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2008.05a
    • /
    • pp.242-246
    • /
    • 2008
  • This study is to research on the condition of safe environment of kindergartens. This study is to supplement the preceding study which was based only on survey to show the result and analyze the condition and problems of the safety of kindergartens to suggest the basic database of indoor environment that cause accident. First as a theoretical study, we analyze the preceding studies according to the related regulations. And we made checklist based on this and visited and investigated two kindergartens where applied for the case study As the result, we could understand factors that can cause accidents from classroom, corridor, door, stairs, balustrade, toilet, kitchen, front door, and fire exit/shelter. Especially, in case of fire exit/shelter, the whole renewal of kindergarten was necessary which is difficult. But, though it can not be advanced right away, they should try to have facility expansion and repair works gradually. And for more study on this, active cooperation from kindergartens are in need.

  • PDF

Performance Analysis of the the Single Alarm Detector in the Rooms of Single Houses by Computer Simulation (시뮬레이션을 통한 주거공간 단독경보형감지기의 성능 분석)

  • Lim, Geun-Joo;Park, Sang-Cheon;Baek, Eun-Sun
    • Fire Science and Engineering
    • /
    • v.34 no.4
    • /
    • pp.29-35
    • /
    • 2020
  • This study was conducted to examine the performance in the space for a single alarm type detector installed in a single house. Three types of houses were used, including two types of one-story and two-story houses. A computer simulation program was used to predict the sound pressure level in response to the occurrence of an alarm sound in a residential space. The characteristics of the sound source applied to the simulation were directly measured and used as input data. As a result of simulation, it was found that the sound pressure level in the kitchen and living room generally met the standard when the alarm sound of the detector occurred. However, the sound pressure level in the bedroom was predicted to be at least 20 dB (A) lower than the American Fire Protection Association standard of 75 dB (A). Therefore, a plan should be prepared to maintain a sufficient sound level in the bedroom space inside the house, and efforts will be needed to ensure safe evacuation in case of fire by establishing relevant standards.

A study on Fire Case and Countermeasure of Tourist Hotel (관광호텔의 화재손해 위험관리방안 - 화재발생현황과 대형화재사례 분석 중심)

  • Han, Sukman;Son, Jung Hyoun;Kim, Jong Won
    • Journal of the Society of Disaster Information
    • /
    • v.8 no.4
    • /
    • pp.362-375
    • /
    • 2012
  • Tourist hotels are equipped with facilities such as accommodation and restaurants, exercise, recreation. Unspecified guests, visitors and management of tourist hotels are very vulnerable on the casualties and property losses due to fire peril exist. In this study, we analysis that the fire statistics status of tourist hotels from 2001 to 2010. And the 15 cases of a large hotel fire are reviewed. The total number of fires on hotel are consist of a hotel rooms fire(33.2%), a restaurant kitchen fire(11.8%). And the major causes of the fire are an electrical fire (40.8%), a cigarette fire (14.5%) and a hot-work fire (9.2%). In case study, the fire wall defect and combustible materials are major fire loss causes for 10year. Each tourist hotels are needed a development of suitable fire risk management and a field operations. A hotel is required an active fire risk management on a preventive inspection, an education and training, and a preventive maintenance. It is necessary that a fire wall maintenance to prevent of the spread of a fire and a sprinkler installation of whole area to protect fire. And it is very important an emergency response for evacuation of guest, and operate emergency procedures on a fire or emergency situation.