• Title/Summary/Keyword: King Sejong Station

Search Result 80, Processing Time 0.022 seconds

Wind Resource Assessment of the Antarctic King Sejong Station by Computational Flow Analysis (남극 세종기지의 전산유동해석에 의한 풍력자원평가)

  • Kim, Seok-Woo;Kim, Hyun-Goo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.376-377
    • /
    • 2007
  • In accordance with Madrid and Kyoto Protocols, a 10kW wind turbine installed about 625m away from the King Sejong Station in the Antarctica has been in operation successfully. The current location of the wind turbine has different geographic surroundings from the previous candidate site considered in 2005 and that makes re-evaluation of wind resource at the current site including geographic effects necessary. Especially, strong wind flow derived by steep and complex terrain is dominant in the Antarctica so that computational flow analysis is required. The wind rose measured at the previous and current installation location are identical with strong meteorological correlation but prevailing directions of wind power density are different because of local wind acceleration due to complex terrain. Numerical analysis explains which effects brings this discordance between the two sites, and a design guideline required for additional wind turbine installation has been secured.

  • PDF

Ground-based Observations for the Upper Atmosphere at King Sejong Station, Antarctica

  • Jee, Geonhwa;Kim, Jeong-Han;Lee, Changsup;Kim, Yong Ha
    • Journal of Astronomy and Space Sciences
    • /
    • v.31 no.2
    • /
    • pp.169-176
    • /
    • 2014
  • Since the operation of the King Sejong Station (KSS) started in Antarctic Peninsula in 1989, there have been continuous efforts to perform the observation for the upper atmosphere. The observations during the initial period of the station include Fabry-Perot Interferometer (FPI) and Michelson Interferometer for the mesosphere and thermosphere, which are no longer in operation. In 2002, in collaboration with York University, Canada, the Spectral Airglow Temperature Imager (SATI) was installed to observe the temperature in the mesosphere and lower thermosphere (MLT) region and it has still been producing the mesopause temperature data until present. The observation was extended by installing the meteor radar in 2007 to observe the neutral winds and temperature in the MLT region during the day and night in collaboration with Chungnam National University. We also installed the all sky camera in 2008 to observe the wave structures in the MLT region. All these observations are utilized to study on the physical characteristics of the MLT region and also on the wave phenomena such as the tide and gravity wave in the upper atmosphere over KSS that is well known for the strong gravity wave activity. In this article, brief introductions for the currently operating instruments at KSS will be presented with their applications for the study of the upper atmosphere.

Year-round Monitoring of Atmospheric Polychlorinated Biphenyls (PCBs) at the King Sejong Station in the Antarctic (남극 세종기지에서의 대기 중 PCB 모니터링)

  • Choi, Sung-Deuk;Baek, Song-Yee;Chang, Yoon-Seok;Yoon, Young-Jun;Park, Byong-Kwon;Hong, Sung-Min
    • Ocean and Polar Research
    • /
    • v.29 no.4
    • /
    • pp.297-302
    • /
    • 2007
  • Atmospheric levels of polychlorinated biphenyls (PCBs) at the King Sejong station were monitored for one year using passive air samplers. Low-chlorinated PCB homologues were predominant in all samples. PCB levels were observed to decrease with distance from the station, which may indicate that a significant part of PCBs could be of local origin. Although the level of PCBs at the King Sejong station is very low (${\Sigma}_9PCB$ (18, 52, 101, 118, 128, 138, 153, 180, 187): $2.3\;pg\;m^{-3}$) probably due to decrease in the global PCB emissions, it is one order of magnitude higher than a background level in the Antarctic. Based on this preliminary study, more interpretation on PCB data and meteorological conditions is required.

A Study of Applicability of Monitoring System through Polar Environment around the King Sejong Station, Antarctica (극지환경을 고려한 남극 세종과학기지 계측시스템 적용성에 관한 연구)

  • Park, Keunbo;Kim, Young Seok
    • Journal of the Korean Geosynthetics Society
    • /
    • v.12 no.2
    • /
    • pp.43-53
    • /
    • 2013
  • Environmental monitoring analysis were analyzed for the period from 1988 to 2007 near King Sejong Station. Extreme environment structure behaviors(Marine Biology Lab.) were evaluated using monitoring sensors developed commercial sensors. Also when installing the sensors ambient environment of the King Sejong Station, to analyze the measured data and the comparative behavior of the structure were analyzed. As a environmental monitoring analysis result at King Sejong Station temperature, sensors were installed to withstand about $-25.6^{\circ}C$ or less and 49.5m/s. They were needed that the height of 225.0cm or more to be installed during the installation. For several monitoring sensors used in Antarctic, temperature, snow and strong winds were very sensitive to the atmospheric environment. Quite often a camouflage(animals and humans) would make it necessary to provide housing for monitoring sensors. Therefore, protection system developed for these sensors were to protect the sensors and data logger. Protection system the newly developed, is economical, easy to install even in harsh environments. Based on the measurement result of the one year, consider electrode applicability of the protection system, it was confirmed that the behavior of the structure is also predictable.

Power Quality Analysis of Wind-Diesel Hybrid Generation System Installation Area (복합발전 풍력-디젤 하이브리드 시스템 설치 지역의 전력품질 분석)

  • An, Hae-Joon;Kim, Hyun-Goo;Kim, Seok-Woo;Ko, Seok-Whan;Jang, Gil-Soo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.539-541
    • /
    • 2009
  • A severely cold weather condition of King Sejong Station, Antarctica becomes a very severe condition for an installation/operation of wind generation system. When the existing wind generation system works, it may cause a damage and destruction of wind generation system and can bring about big problems in terms of the power quality. Accordingly, it is essential to obtain technologies for the installation and operation of small wind generation system for the polar region's wind generation, and to assess and demonstrate the performance in the severely-cold environment and the polar wind generation system's development, supplementation, alteration. Also, as the available power of King Sejong Station, Antarctica, the diesel generator has been mainly used, and the wind generator has been used in the hybrid form. Wind generation and diesel generation has the different load following control each other. In the wind generation, the generated power very rapidly changes according to the change of the velocity of the wind. On the other hand, the diesel generation shows very gentle change in the velocity of output. Therefore, the study is intended to analyze the 10kw small wind generator-diesel generator's power quality of King Sejong Station, Antarctica, which is the hybrid system installation area.

  • PDF

The Vertical Distribution of Radiative Flux and Heating Rate at King Sejong Station in West Antarctica (남극 세종기지에서 복사 속 및 복사 가열률의 연직 분포)

  • Lee, Kyu-Tae;Lee, Bang-Yong;Lee, Won-Hak;Jee, Joon-Bum;Lee, Min-Kyung
    • Ocean and Polar Research
    • /
    • v.27 no.1
    • /
    • pp.87-95
    • /
    • 2005
  • The vertical profiles of radiative flux and heating rate at King Sejong Station in West Antarctica were calculated with radiative transfe model by Chou and Suarez (1999) and Chou et al (2001). To run this model, the profiles of temperature, mixing ratios of water vapor and ozone at King Sejng Station were derived from ECMWF Reanalysis data. The surface temperature and albedo were also derived from NCEP/NCAR Reanalysis and CERES data. The radiative flux strongly depends on the cloud optical path length that was calculated using the measured W-h data and model by Chou and Lee(1996). Durins the period of $2000{\sim}2001$ (12 and 18 UTC), the correlation coefficient between calculated and measured downward solar fluxes at surface was 0.90 and the coefficient for downward longwave flux was 0.61. The calculated net heating rates of surface layer decreased during the same period, the trend of which was in accordance with the decrease of measured temperature.

Preliminary Report on the Ecology of the Penguins Observed in the Cold Years and a Less Cold Year in the Vicinity of King Sejong Station, King George Island off the Antarctic Peninsula (남극 세종기지에서 추운 해와 덜 추운 해에 관찰된 펭귄들의 생태에 관한 1차보고)

  • Chang, Soon-Keun
    • Ocean and Polar Research
    • /
    • v.26 no.1
    • /
    • pp.87-101
    • /
    • 2004
  • This paper delineated the ecology including movement (departure from the rookery and returning to the rookery), egg-laying, and hatch of the penguins occurred in the cold years and a less cold year in the vicinity of King Sejong Station, King George Island off the Antarctic Peninsula. The years of 1988, 1991, 1992, and 1995 were selected as cold years and the year of 2001 was selected as a less cold year based on the mean annual temperature of the years. Gentoo Penguin (Pygoscelis papua) left their rookery in May, meanwhile some remained around the station. They returned in middle-September in the less cold .year, and returned in late-September to early-October in the cold years. Chinstrap Penguin (Pygoscelis antarctica) left their rookery in early-April in the cold years as well as in the less cold year without exception. They returned to the rookery in late-October to early-November in cold years, meanwhile in early-October in the less cold year. This difference in the returning of this bird seems to be related with the exposed sea water, i.e., sea ice condition to feed in the sea. The global warming will lead to the appearance of birds which breed in the Sub-Antarctic. For example, one pair of King Penguin (Aptenodytes patagonicus) was observed in the Maxwell Bay in austral summer. And a pair of snide-like bird was recently observed for the first time in November 2001 at the penguin rookery located in the Barton Peninsula, King George Island. And it will also lead to the disappearance of an Emperor Penguin (Aptenodytes forsteri) which appeared in the full winter when Maxwell Bay and Marian Cove were frozen. It seems that the behaviour of the penguins observed around the station shows the complex effects of the ecology of the birds in combination with the natural environments, which include feeding strategy and areas, animal Instincts, exposed terrain related to weather conditions, and globa1 warming. It is necessary to take further observation and carry out systematic researches on the birds including penguins around the station which show the ecology of the birds as well as the environmental changes.

Land-Cover Classification of Barton Peninsular around King Sejong station located in the Antarctic using KOMPSAT-2 Satellite Imagery (KOMPSAT-2 위성 영상을 이용한 남극 세종기지 주변 바톤반도의 토지피복분류)

  • Kim, Sang-Il;Kim, Hyun-Cheol;Shin, Jung-Il;Hong, Soon-Gu
    • Korean Journal of Remote Sensing
    • /
    • v.29 no.5
    • /
    • pp.537-544
    • /
    • 2013
  • Baton Peninsula, where Sejong station is located, mainly covered with snow and vegetation. Because this area is sensitive to climate change, monitoring of surface variation is important to understand climate change on the polar region. Due to the inaccessibility, the remote sensing is useful to continuously monitor the area. The objectives of this research are 1) map classification of land-cover types in the Barton Peninsular around King Sejong station and 2) grasp distribution of vegetation species in classified area. A KOMPSAT-2 multispectral satellite image was used to classify land-cover types and vegetation species. We performed classification with hierarchical procedure using KOMPSAT-2 satellite image and ground reference data, and the result is evaluated for accuracy as well. As the results, vegetation and non-vegetation were clearly classified although species shown lower accuracies within vegetation class.

Demonstration of 10kw Wind Turbine System at the King Sejong Station (극한환경에서의 소형풍력발전 실증운전)

  • Kim, Seok-Woo;Kyong, Nam-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.26 no.4
    • /
    • pp.25-30
    • /
    • 2006
  • 10kW wind turbine has been successfully commissioned at the King Sejong station in April, 2006. The wind turbine installed is a part of the R&D program for developing a solid wind/diesel hybrid power control system for a remote area such as Antarctica. At the same time, the current research aims to develop an anti-icing and de-icing technologies for a small wind turbine rated under 50kW. Since its commissioning, the turbine has generated about 500kWh for 47days without any system faults. Although sufficient data have not been obtained yet, any trouble has not occurred in the wind/diesel hybrid system based on the current analysis. Concerning on the environmental impact by the wind turbine operation, the turbine is installed within the station boundary in order to meet the Madrid protocol. Therefore, wind turbine operation meets the international requirements for preservation of antarctic ecosystem.