• Title/Summary/Keyword: Kinetic Coefficient

Search Result 324, Processing Time 0.022 seconds

Kinetic Friction of Grains on Surfaces (곡물의 동마찰계수 측정에 관한 연구)

  • 김만수;이동호
    • Journal of Biosystems Engineering
    • /
    • v.1 no.1
    • /
    • pp.49-54
    • /
    • 1976
  • No reliable basic data were available on the kinetic friction coefficients between grains and frictional surfaces being used in grain handling equipments in Korea. In order to determine appropriate kinetic friction coefficient between three grains (Tongil, Jinheung, barley) and two surfaces at four levels of moisture content of grain, the laboratory tests using the newly designed experimental apparatus and strain gage measuring system were carried out, and the relationship among factors that affect kinetic friction coefficients of grains were analyzed. The results of this study are summarized as follows ; 1. Kinetic friction coefficient of samples being tested was dependent on surfaces and moisture content of grains . The ranges of them were 0.369-0.512 for Tongil variety , 0.347-0.469 for Jinheung variety, and 0.360-0.502 for barley, respectively. 2. There was a little difference of kinetic friction coefficients between two varieties of rice at the same testing conditions. Because the interaction had been large among treatments , each value of kinetic friction coefficient determined in this study should be used only for the corresponding conditions in this study . 3. Kinetic friction coefficients in creased linearly with increase in moisture content of grains and their regression equations were shown in Table.4. 4. Kinetic friction coefficients on a PVC surfaces was shown a little lower values than on the steel surfaces at various moisture levels, but especially in Jinheung and barley, a big difference was shown.

  • PDF

Implementation and the Energy Efficiency of the Kinetic Shading System (가동형 차양 시스템의 구성과 에너지 효율)

  • Han, Seung-Hoon
    • KIEAE Journal
    • /
    • v.14 no.5
    • /
    • pp.67-73
    • /
    • 2014
  • This study aims at examining kinetic efficient shading systems and their implementation methods. These days, the importance of the shading devices are getting more significant due to the energy problem. Cordially, suitable shade designs are required as an important element for the exterior envelope of the building. This study employs the optimal shading design as an efficient shading method with the kinetic system that can be converted actively by the altitude of the sun. The proposed kinetic shading system works not only as a lightshelf in case the altitude of the sun is high but also as a vertical louver when the sun is getting lower in order to block the direct sunlight. This study has analyzed the thermal performance and shading coefficient of the kinetic shading system in comparison to existing fixed shading devices using the Ecotect. The results, in sum, conclude that the suggested kinetic shading system could decrease direct sunlights 26.2% more than the existing shading methods.

Energy Conservation for Runoff and Soil Erosion on the Hillslope (산지사면의 유출 및 토양침식에 대한 에너지 보존)

  • Shin, Seung-Sook;Park, Sang-Deog;Cho, Jae-Woong;Hong, Jong-Sun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.234-238
    • /
    • 2008
  • The energy conservation theory is introduced for investigating processes of runoff and soil erosion on the hillslope system changed vegetation condition by wildfire The rainfall energy, input energy consisted of kinetic and potential energy, is influenced by vegetation coverage and height. Output energy at the outlet of hillslope is decided as the kinetic energy of runoff and erosion soil, and mechanical work according to moving water and soil is influenced dominantly by the work rather than the kinetic energy. Relationship between output and input energy is possible to calculate the energy loss in the runoff and erosion process. The absolute value of the energy loss is controlled by the input energy size of rainfall because energy losses of runoff increase as many rainfall pass through the hillslope system. The energy coefficient which is dimensionless is defined as the ratio of input energy of rainfall to output energy of runoff water and erosion soil such as runoff coefficient. The energy coefficient and runoff coefficient showed the highest correlation coefficient with the vegetation coverage. Maximum energy coefficient is about 0.5 in the hillslope system. The energy theory for output energy of runoff and soil erosion is presented by the energy coefficient theory associated with vegetation factor. Also runoff and erosion soil resulting output energy have the relation of power function and the rates of these increase with rainfall.

  • PDF

Validation of Kinetic Method for the PKA Assay in Plasma-Derived Products

  • Shin, In-Soo;Hong, Choong-Man;Koh, Hyun-Chul;Hong, Seung-Hwa
    • Biomolecules & Therapeutics
    • /
    • v.13 no.1
    • /
    • pp.59-63
    • /
    • 2005
  • A kinetic assay was carried out in order to compare the ability of detection for prekallikrein activator(PKA) in plasma-derived products with that of an endpoint assay and a commercial method. Using these methods, 9 human albumin preparations were assayed and compared to each other. The coefficient of variation between the Kinetic assay and the end point assay was found within 6.6% and this result showed that two methods were highly correlative and the end point assay could act as a replacement of the kinetic assay. Another important goal of this study was to investigate the reproducibility among laboratories on the kinetic assay. A collaborative study was performed to validate the kinetic method with intra and inter assays. The coefficient of variation for the intra assay of each laboratory was less than 4% and that for between individuals in the inter assay was 4.1%. These results revealed that the kinetic assay showed good reproducibility. The contents of PKA in plasma-derived products were also determined by the kinetic assay. As a result, it was found that trace amounts of PKA were present in 32 human immunoglobulin preparations, however the average concentration of PKA in 171 albumin preparations was 5.8 IU/mL.

Development of New Measurement Device for the Coefficient of Kinetic Friction by Using Side Air-Guide Track (측면 에어 가이드 트랙을 이용한 새로운 운동마찰계수 측정 장치의 개발)

  • Nam, Hyoung Joo
    • Journal of Engineering Education Research
    • /
    • v.21 no.3
    • /
    • pp.12-19
    • /
    • 2018
  • In this study, a new experimental device was developed for measurement of the coefficient of kinetic friction using a photo gate timer system which have advantages of easy and accurate detection of motion. This device, consisting of a side air-guide track and a side friction-free glider, forces a friction sample to move in a straight line without producing unnecessary friction. The new device is compared to two conventional measuring methods of friction for four different friction samples: one is using a camera system and the other is using a force sensor. It is demonstrated that the developed friction device in this study is easier to operate and produces the most accurate and the least deviating results among them. On the basis of these results, we propose that friction experiment using the new friction device is included in general physics experiment, so that engineering students should have a chance to get correct understanding of classical mechanics including friction phenomenon.

Effect of Recalcitrant Organics on Bio-kinetic Coeffcient and Biodegradable in Box-mill Wastewater (판지공장 폐수 중 난분해성 유기물질이 동력학적 계수 및 생분해에 미치는 영향)

  • Cho, Yong Duck;Lee, Sang Wha
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.3
    • /
    • pp.329-338
    • /
    • 2006
  • The research aims to provide the basic data for practical applications by correlating the bio-kinetic coefficients with the load of recalcitrant organic matter in box-mill wastewater. The activated sludge process was employed to a Wastewater disposal plant in an industrial setting, increase of consequently leading to the organic load. The parameter values derived by Monod-kinetic analysis were as follows:specific substrate removal rate $K_{max}=0.17day^{-1}$, half saturation constants $K_s=60.37mg/l$, decay coefficient $K_d=0.142day^{-1}$, microbial yield coefficient y = 0.388mg/mg, and max specific growth rate ${\mu}_{max}=0.006day^{-1}$. In view of biodegradability, the $TCOD_{Mn}/TBOD_5$ ratios of inflow and outflow were 1.07 and 1.41, and the $SCOD_{Mn}/SBOD_5$ ratios of inflow and outflow were 1.10 and 1.50, respectively. The higher $TCOD_{Mn}/TBOD_5$ ratio of outflow indicated that metabolites of a microorganism have accumulated in the cells.

Friction-induced Vibration of a Linear Compressor (Linear Compressor에서 발생하는 마찰에 의한 진동 연구)

  • 박종찬;왕세명;정충민
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.695-700
    • /
    • 2003
  • This paper dealt with friction-induced vibrations in engineering practice, specifically arising at the moment of counterturn of two friction surfaces. The harshness of the vibrations are attributed to the sharp change of the friction coefficients from kinetic to static near zero relative velocity, which is one of the examples of the stick slip. But the experimental results and numerical analysis of piston and cylinder operation showed that transition of the friction coefficient from kinetic to static is insignificant in vibrations. Dry friction itself dominates the harshness of vibrations. This study shows that how dry friction triggers the vibrations and demonstrates the effect of sharp transition from kinetic to static friction coefficient on the vibrations.

  • PDF

Kinetic Features of the Cobalt Dihalide/Methylaluminoxane Catalytic System in 1,3-Butadiene Polymerization

  • Nath Dilip Chandra Deb;Fellows Christopher M.;Shiono Takeshi
    • Macromolecular Research
    • /
    • v.14 no.3
    • /
    • pp.338-342
    • /
    • 2006
  • The kinetic features of polymerization with an active site comprising cobalt dihalides ($CoX_2$, where X=Cl, Br, I) activated by methylaluminoxane (MAO) were investigated in 1,3-butadiene polymerization. The catalytic system exhibited the characteristic features of living polymerization. The initiation ($k_i$) and propagation ($k_p$) rate coefficients were estimated using the kinetic model for slow initiation previously reported by Shiono et al. The energy of activation fur the propagation reaction was calculated to be 27-30 $kJmol^{-1}$. The marked changes in reaction rate observed with different halides could be adequately described in terms of variations in the initiation process, with the same Arrhenius curve fitting propagation rate coeffcients estimated from all three halides, suggesting that the halide does not participate in the growing chain end.

Adsorption Kinetic Study of Ruthenium Complex Dyes onto TiO2 Anodes for Dye-sensitized Solar Cells (DSSCs) (염료감응 태양전지용 루테늄 금속착체 염료의 이산화티타늄 전극에 대한 동적 흡착 연구)

  • An, Byeong-Kwan
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.11
    • /
    • pp.929-934
    • /
    • 2011
  • The adsorption kinetic study of ruthenium complex, N3, onto nanoporous titanium dioxide ($TiO_2$) photoanodes has been carried out by measuring dye uptake in-situ. Three simplified kinetic models including a pseudo first-order equation, pseudo second-order equation and intraparticle diffusion equation were chosen to follow the adsorption process. Kinetic parameters, rate constant, equilibrium adsorption capacities and related coefficient coefficients for each kinetic model were calculated and discussed. It was shown that the adsorption kinetics of N3 dye molecules onto porous $TiO_2$ obeys pseudo second-order kinetics with chemisorption being the rate determining step. Additionally the heterogeneous surface and the pore size distribution of porous $TiO_2$ adsorbents were also discussed.

Drug-Induced Diabetes Mellitus and Monitoring Hyperglycemic Control in Dogs 1. Comparison of Three Methods of Measuring Fructosamine (개에 있어서 약물에 의한 당뇨병의 유발과 혈당제어의 감시에 관한 연구 1. 세 가지 Fructosamine측정법의 비교 실험)

  • 이창우;최희인;김본원
    • Journal of Veterinary Clinics
    • /
    • v.15 no.2
    • /
    • pp.279-290
    • /
    • 1998
  • The diagnosis of canine diabetes mellitus is generally made by measuring serum fructosamine levels. The Rosental's end points Tas and El Din's kinetic, and Johnson and colleagues'kinetic techiniques were compared for the measuring serum fructosamine levels. In the Rosental's end point methods within-run and between-run coefficient of variability (CV) were 2.4-3.5% and 6.8-8.5%, respectively, and in the Tas and El Din's kinetic method, within-run and between-run CV were 1.3-3.0% and 3.4-3.9%, respectively. In the Johnson and colleagues'kinetic methods within-run and between-run CV were 0-1.8% and 3.1-6.8%1 ruts- pectively. Hyperlipidemia induced by oral administration of 3 ml of corn oil per kilogram body weight did not affect serum fructosamine concentration significantly in the Johnson and colleagues' kinetic method Johnson and colleagues'kinetic method is most reliable and consistant on the basis of comparison study.

  • PDF