• 제목/요약/키워드: Kinematic Accuracy

검색결과 315건 처리시간 0.028초

위치 정밀도 향상을 위한 관절강성 파라미터 포함 로봇 캘리브레이션 (Robot Calibration with Joint Stiffness Parameters for the Enhanced Positioning Accuracy)

  • 강희준;신성원;노영식;서영수;임현규;김동혁
    • 제어로봇시스템학회논문지
    • /
    • 제14권4호
    • /
    • pp.406-410
    • /
    • 2008
  • This paper presents a new robot calibration algorithm with joint stiffness parameters for the enhanced positioning accuracy of industrial robot manipulators. This work is towards on-going development of an industrial robot calibration software which is able to identify both the kinematic and non-kinematic robot parameters. In this paper, the conventional kinematic calibration and its important considerations are briefly described first. Then, a new robot calibration algorithm which simultaneously identifies both the kinematic and joint stiffness parameters is presented and explained through a computer simulation with a 2 DOF manipulator. Finally, the developed algorithm is implemented to Hyundai HX165 robot and its resulting improvement of the positioning accuracy is addressed.

로보트 accuracy향상을 위한 kinematic identification (Kinematic Iidentification for Improving Robot Accuracy)

  • 조선휘;김문상;김귀식;장현상
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1989년도 한국자동제어학술회의논문집; Seoul, Korea; 27-28 Oct. 1989
    • /
    • pp.131-137
    • /
    • 1989
  • The effect of kinematic model choice on robot calibration is examined. This paper presents a complete formulation to identify the actual robot kinematic parameters directly from position data. The method presented in this paper applies to any serial link manipulator with arbitrary order and combination of revolute and prismatic joint.

  • PDF

국지측량에서의 현장 Calibration에 의한 RTK-GPS 정확도 분석 (The Accuracy Analysis of RTK-GPS by Field Calibration in Plane Surveying)

  • 박운용;신동수
    • 대한공간정보학회지
    • /
    • 제10권2호
    • /
    • pp.87-95
    • /
    • 2002
  • 실시간 동적(Real Time Kinematic) GPS는 실시간으로 높은 정밀도의 위치결정을 가능케 해준다. 만약 미지정수를 구하기 위하여 정수해를 사용한다면 수 mm의 정확도를 얻을 수 있고, 실 수해를 얻는다면 수십 cm 의 정확도를 얻을수 있다. 본 연구에서는 통일 측점에 대해 기존의 재래식 측량기법(Total Station), 정적(Static) 상대측위 GPS기법과 현장 Calibration에 의한 실시간 동적(Real Time Kinematic) GPS기법에 의해 측량을 수행하여 각 기법별 측정의 정확도 등을 비교 분석하여 현장 Calibration에 의한 실시간 동적 (Real Time Kinematic) GPS기법의 정확도를 분석고자 한다. 국소지역에서 기존의 실시간 동적(Real Time Kinematic) GPS방식을 보완한 현장 Calibration에 의한 실시간 동적(Real Time Kinematic) GPS 측량을 수행한 결과, 미지정수해의 고정해를 얻지 못하는 경우를 제외하고는 모두 6cm 이하의 오차가 나타났고, Control Point의 측점수를 3개와 4개로 변화시켜 실시간 동적(Real Time Kinematic) GPS 측량을 수행한 결과 두 측정치의 차이는 최대 3cm로 나타났다. 최종적으로 국소지역에서도 현장 Calibration에 의한 실시간 동적(Real Time Kinematic) GPS기법이 사용가능함을 알 수 있었다.

  • PDF

마이크로 병렬기구 플랫폼의 기구학적 보정 (Kinematic calibration for parallel micro machine platform)

  • 강득수;김종원
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2004년도 추계학술대회 논문집
    • /
    • pp.969-972
    • /
    • 2004
  • This paper describes the mechanism of parallel micro machine platform and its feedback control system for acquiring high accuracy. The parallel micro machine platform that has developed has 5x5x5 work-space and sub-micron accuracy. For the high accuracy, the feedback control system is important but errors in machining and assembling are inevitable. Kinematic calibration is important for this reason. In this paper, various error components are introduced and the effects of error component are analyzed.

  • PDF

5축 혼합형 공작기계의 정밀도 향상 연구 (Accuracy Improvement of a 5-axis Hybrid Machine Tool)

  • 김한성
    • 한국산업융합학회 논문집
    • /
    • 제17권3호
    • /
    • pp.84-92
    • /
    • 2014
  • In this paper, a novel 5-axis hybrid-kinematic machine tool is introduced and the research results on accuracy improvement of the prototype machine tool are presented. The 5-axis hybrid machine tool is made up of a 3-DOF parallel manipulator and a 2-DOF serial one connected in series. The machine tool maintains high ratio of stiffness to mass due to the parallel structure and high orientation capability due to the serial-type wrist. In order to acquire high accuracy, the methodology of measuring the output shafts by additional sensors instead of using encoder outputs at the motor shafts is proposed. In the kinematic view point, the hybrid manipulator reduces to a serial one, if the passive joints in the U-P serial chain at the center of the parallel manipulator are directly measured by additional sensors. Using the method of successive screw displacements, the kinematic error model is derived. Since a ball-bar is less expensive than a full position measurement device and sufficiently accurate for calibration, the kinematic calibration method of using a ball-bar is presented. The effectiveness of the calibration method has been verified through the simulations. Finally, the calibration experiment shows that the position accuracy of the prototype machine tool has been improved from 153 to $86{\mu}m$.

Comparisons of Accuracy of Knee Joint Motion During Closed verse Open Kinetic Chain Tasks in Subjects with Flexible Flatfeet

  • Kim, Ju Sang;Kwon, Younghyun;Lee, Mi Young
    • The Journal of Korean Physical Therapy
    • /
    • 제31권1호
    • /
    • pp.13-17
    • /
    • 2019
  • Purpose: This study examined the effects of flexible flatfeet on the accuracy of knee joint motions in closed and open kinetic chain tasks. Methods: Twenty-four healthy participants were recruited for this study. The subjects were divided into two groups using a navicular drop (ND) test: flexible flatfoot group (n=12, male: 6, aged $22.00{\pm}2.22years$) and age-matched control group (n=12, males: 6, aged $22.17{\pm}1.53years$). The accuracy of knee motion was measured quantitatively by tracing through the flexion and extension motion of the knee joints in the closed kinetic chain and the open kinetic chain. Results: There was a significant difference in the accuracy index between the groups in closed kinetic chain task, but there was no significant difference in the open kinetic chain task. In addition, there was a significant difference in the accuracy index between the closed kinetic chain and the open kinetic chain task in the flexible flatfoot group. In addition, a significant negative correlation was observed between the ND and accuracy index in the closed kinematic chain task, but there was no significant relationship between the ND and accuracy index in the open kinematic chain task. Conclusion: Flexible flatfeet can affect the accuracy of the adjacent joints, such as the knee joint in the closed kinematic chain.

병렬기구형 공작기졔의 기구학적 보정에 관한 연구 (Study on Kinematic Calibration of a Parallel-typed Machining Center Tool)

  • 이민기;김태성;박근우
    • 대한기계학회논문집A
    • /
    • 제26권11호
    • /
    • pp.2237-2244
    • /
    • 2002
  • This research develops a low-cost and high accuracy kinematic calibration method based on the following principles: 1) the platform locations are accurately measured by a constrained movement to inspect a calibration target; 2) the constrained movement is chosen to guarantee the parameter observability; 3) the mechanical fixture to constrain the movement and the sensor to check the constrained movement are implemented by low-cost and high-accuracy devices; 4) the calibration is easily done at an industrial environment. The kinematic parameters calibrated with respect to a single plane aren't influenced due to the misalignment of the plane. A parameter observability is successfully obtained even through one planar constraint, which guarantees that all kinematic parameters are estimated by minimizing the cost function.

병렬기구 공직기계의 머신시뮬레이션 및 가공정밀도 평가 (The Evaluation of Machining Accuracy and the Machine Simulation for Parallel Kinematic Machine Tool(PKMT))

  • 신혁;유한식;고해주;정윤교
    • 한국기계가공학회지
    • /
    • 제8권4호
    • /
    • pp.41-47
    • /
    • 2009
  • This research deals with evaluation of machining accuracy for Parallel Kinematic Machine Tool(PKMT) applied parallel type robot system with high precision and stiffness. For this purpose, machine simulation is carried out to foreknow collision and interference between workpiece and tool. Furthermore, on the basis of machine simulation data, PKMT is manufactured. Machining accuracy such as cylindricity straightness, squareness, parallelism circularity, concentricity pitch error and yaw error, is measured by using coordinate measuring machine. Test piece for evaluation of machining accuracy is designed and manufactured under the standard of ISO 10791-7.

  • PDF

병렬로봇의 설계 공차가 궤적 정밀도에 미치는 영향 분석 (The Analysis of Trajectory Tracking Error Caused by the Tolerance of the Design Parameters of a Parallel Kinematic Manipulator)

  • 박찬훈;박동일;김두형
    • 로봇학회논문지
    • /
    • 제11권4호
    • /
    • pp.248-255
    • /
    • 2016
  • Machining error makes the uncertainty of dimensional accuracy of the kinematic structure of a parallel robot system, which makes the uncertainty of kinematic accuracy of the end-effector of the parallel robot system. In this paper, the tendency of trajectory tracking error caused by the tolerance of design parameters of the parallel robot is analyzed. For this purpose, all the position errors are analyzed as the manipulator is moved on the target trajectory. X, Y, Z components of the trajectory errors are analyzed respectively, as well as resultant errors, which give the designer of the manipulator the intuitive and deep understanding on the effects of each design parameter to the trajectory tracking errors caused by the uncertainty of dimensional accuracy. The research results shows which design parameters are critically sensitive to the trajectory tracking error and the tendency of the trajectory tracking error caused by them.

네트워크 기반 키너매틱 위치결정을 위한 단일기선 GPS해의 최적 결합 (The Optimized Integration of Single-baseline GPS Solutions for Network-based Kinematic Positioning)

  • 최윤수;배태석;이종기;권재현
    • 한국측량학회지
    • /
    • 제25권3호
    • /
    • pp.207-213
    • /
    • 2007
  • 다수의 고정수신기를 이용하여 이동수신기의 위치를 정확히 측정하고자 하는 필요성은 계속적으로 대두되고 있었으나, 현재 사용되고 있는 대부분의 상용 소프트웨어에서는 단일기선에 대한 GPS 결과만을 제공하고 있다. 따라서 본 논문에서는 다수의 단일기선 결과를 이용하여 네트워크를 구성함으로써 이동수신기의 위치측정 정확도를 향상시키기 위한 방안을 연구하였다. 이를 위해 기존의 측지 망 조정 이론을 도입하여 이동수신기의 위치결정 분야에 적용함으로써 위치정확도 향상 뿐만 아니라 전체적인 네트워크의 안정에도 기여할 수 있음을 알 수 있었다. 또한 측지망의 계수부족(Rank-deficiency)을 제거하기 위해서 하나의 고정수신기의 위치를 고정시키는 방법(RLESS), 이동수신기의 바이어스(Bias)를 최소화하는 방법(BLIMPBE), 그리고 고정수신기의 위치에 확률적 제약 조건을 주는 방법(SCLESS)에 대해서 비교 분석하였다. 네트워크 기반의 위치결정을 통해서 3차원 평균제곱근오차(RMSE)는 최대 3.5cm에서 2.1cm 수준으로 향상되었고, 기준점의 위치정확도에 따라 BLIMPBE 및 SCLESS 방법을 적절히 적용하는 것이 바람직할 것으로 판단된다.