• Title/Summary/Keyword: Kinematic Accuracy

Search Result 315, Processing Time 0.033 seconds

Robot Calibration with Joint Stiffness Parameters for the Enhanced Positioning Accuracy (위치 정밀도 향상을 위한 관절강성 파라미터 포함 로봇 캘리브레이션)

  • Kang, Hee-Jun;Shin, Sung-Won;Ro, Young-Shick;Suh, Young-Soo;Lim, Hyun-Kyu;Kim, Dong-Hyeok
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.14 no.4
    • /
    • pp.406-410
    • /
    • 2008
  • This paper presents a new robot calibration algorithm with joint stiffness parameters for the enhanced positioning accuracy of industrial robot manipulators. This work is towards on-going development of an industrial robot calibration software which is able to identify both the kinematic and non-kinematic robot parameters. In this paper, the conventional kinematic calibration and its important considerations are briefly described first. Then, a new robot calibration algorithm which simultaneously identifies both the kinematic and joint stiffness parameters is presented and explained through a computer simulation with a 2 DOF manipulator. Finally, the developed algorithm is implemented to Hyundai HX165 robot and its resulting improvement of the positioning accuracy is addressed.

Kinematic Iidentification for Improving Robot Accuracy (로보트 accuracy향상을 위한 kinematic identification)

  • 조선휘;김문상;김귀식;장현상
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1989.10a
    • /
    • pp.131-137
    • /
    • 1989
  • The effect of kinematic model choice on robot calibration is examined. This paper presents a complete formulation to identify the actual robot kinematic parameters directly from position data. The method presented in this paper applies to any serial link manipulator with arbitrary order and combination of revolute and prismatic joint.

  • PDF

The Accuracy Analysis of RTK-GPS by Field Calibration in Plane Surveying (국지측량에서의 현장 Calibration에 의한 RTK-GPS 정확도 분석)

  • Park, Woon-Yong;Shin, Dong-Soo
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.10 no.2 s.20
    • /
    • pp.87-95
    • /
    • 2002
  • Real-time Kinematic GPS enables high accuracy Positioning by real time. If ambiguity use an integer solution, can obtain accuracy of several 'mm', and can obtain accuracy of tens 'em' if use real solution. In this study, We accomplish surveying by existent traditional surveying techniques (Total Station), Static GPS techniques and RTK-GPS techniques by Field Calibration about uniformity measuring point and then compared and ana1yzed each techniques positioning accuracy etc.. Result that achieve by Static-GPS in Plane area, about all measuring points, expressed error fewer than 3cm. Result that achieve RTK-GPS Surveying by Field Calibration in Plane area, could know that RTK-GPS techniques by Field Calibration is available in Plane area because expressing errors fewer than all 6cm, except case that do not get fixed solution of ambiguity Field Calibration RTK-GPS could know economically than existent conventional type measurement and existent GPS's measurement techniques that efficiency is very high.

  • PDF

Kinematic calibration for parallel micro machine platform (마이크로 병렬기구 플랫폼의 기구학적 보정)

  • 강득수;김종원
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.969-972
    • /
    • 2004
  • This paper describes the mechanism of parallel micro machine platform and its feedback control system for acquiring high accuracy. The parallel micro machine platform that has developed has 5x5x5 work-space and sub-micron accuracy. For the high accuracy, the feedback control system is important but errors in machining and assembling are inevitable. Kinematic calibration is important for this reason. In this paper, various error components are introduced and the effects of error component are analyzed.

  • PDF

Accuracy Improvement of a 5-axis Hybrid Machine Tool (5축 혼합형 공작기계의 정밀도 향상 연구)

  • Kim, Han Sung
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.17 no.3
    • /
    • pp.84-92
    • /
    • 2014
  • In this paper, a novel 5-axis hybrid-kinematic machine tool is introduced and the research results on accuracy improvement of the prototype machine tool are presented. The 5-axis hybrid machine tool is made up of a 3-DOF parallel manipulator and a 2-DOF serial one connected in series. The machine tool maintains high ratio of stiffness to mass due to the parallel structure and high orientation capability due to the serial-type wrist. In order to acquire high accuracy, the methodology of measuring the output shafts by additional sensors instead of using encoder outputs at the motor shafts is proposed. In the kinematic view point, the hybrid manipulator reduces to a serial one, if the passive joints in the U-P serial chain at the center of the parallel manipulator are directly measured by additional sensors. Using the method of successive screw displacements, the kinematic error model is derived. Since a ball-bar is less expensive than a full position measurement device and sufficiently accurate for calibration, the kinematic calibration method of using a ball-bar is presented. The effectiveness of the calibration method has been verified through the simulations. Finally, the calibration experiment shows that the position accuracy of the prototype machine tool has been improved from 153 to $86{\mu}m$.

Comparisons of Accuracy of Knee Joint Motion During Closed verse Open Kinetic Chain Tasks in Subjects with Flexible Flatfeet

  • Kim, Ju Sang;Kwon, Younghyun;Lee, Mi Young
    • The Journal of Korean Physical Therapy
    • /
    • v.31 no.1
    • /
    • pp.13-17
    • /
    • 2019
  • Purpose: This study examined the effects of flexible flatfeet on the accuracy of knee joint motions in closed and open kinetic chain tasks. Methods: Twenty-four healthy participants were recruited for this study. The subjects were divided into two groups using a navicular drop (ND) test: flexible flatfoot group (n=12, male: 6, aged $22.00{\pm}2.22years$) and age-matched control group (n=12, males: 6, aged $22.17{\pm}1.53years$). The accuracy of knee motion was measured quantitatively by tracing through the flexion and extension motion of the knee joints in the closed kinetic chain and the open kinetic chain. Results: There was a significant difference in the accuracy index between the groups in closed kinetic chain task, but there was no significant difference in the open kinetic chain task. In addition, there was a significant difference in the accuracy index between the closed kinetic chain and the open kinetic chain task in the flexible flatfoot group. In addition, a significant negative correlation was observed between the ND and accuracy index in the closed kinematic chain task, but there was no significant relationship between the ND and accuracy index in the open kinematic chain task. Conclusion: Flexible flatfeet can affect the accuracy of the adjacent joints, such as the knee joint in the closed kinematic chain.

Study on Kinematic Calibration of a Parallel-typed Machining Center Tool (병렬기구형 공작기졔의 기구학적 보정에 관한 연구)

  • Lee, Min-Ki;Kim, Tae-Sung;Park, Kun-Woo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.11
    • /
    • pp.2237-2244
    • /
    • 2002
  • This research develops a low-cost and high accuracy kinematic calibration method based on the following principles: 1) the platform locations are accurately measured by a constrained movement to inspect a calibration target; 2) the constrained movement is chosen to guarantee the parameter observability; 3) the mechanical fixture to constrain the movement and the sensor to check the constrained movement are implemented by low-cost and high-accuracy devices; 4) the calibration is easily done at an industrial environment. The kinematic parameters calibrated with respect to a single plane aren't influenced due to the misalignment of the plane. A parameter observability is successfully obtained even through one planar constraint, which guarantees that all kinematic parameters are estimated by minimizing the cost function.

The Evaluation of Machining Accuracy and the Machine Simulation for Parallel Kinematic Machine Tool(PKMT) (병렬기구 공직기계의 머신시뮬레이션 및 가공정밀도 평가)

  • Shin, Hyeuk;Ryou, Han-Sik;Ko, Hae-ju;Jung, Yoon-gyo
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.8 no.4
    • /
    • pp.41-47
    • /
    • 2009
  • This research deals with evaluation of machining accuracy for Parallel Kinematic Machine Tool(PKMT) applied parallel type robot system with high precision and stiffness. For this purpose, machine simulation is carried out to foreknow collision and interference between workpiece and tool. Furthermore, on the basis of machine simulation data, PKMT is manufactured. Machining accuracy such as cylindricity straightness, squareness, parallelism circularity, concentricity pitch error and yaw error, is measured by using coordinate measuring machine. Test piece for evaluation of machining accuracy is designed and manufactured under the standard of ISO 10791-7.

  • PDF

The Analysis of Trajectory Tracking Error Caused by the Tolerance of the Design Parameters of a Parallel Kinematic Manipulator (병렬로봇의 설계 공차가 궤적 정밀도에 미치는 영향 분석)

  • Park, Chanhun;Park, DongIl;Kim, Doohyung
    • The Journal of Korea Robotics Society
    • /
    • v.11 no.4
    • /
    • pp.248-255
    • /
    • 2016
  • Machining error makes the uncertainty of dimensional accuracy of the kinematic structure of a parallel robot system, which makes the uncertainty of kinematic accuracy of the end-effector of the parallel robot system. In this paper, the tendency of trajectory tracking error caused by the tolerance of design parameters of the parallel robot is analyzed. For this purpose, all the position errors are analyzed as the manipulator is moved on the target trajectory. X, Y, Z components of the trajectory errors are analyzed respectively, as well as resultant errors, which give the designer of the manipulator the intuitive and deep understanding on the effects of each design parameter to the trajectory tracking errors caused by the uncertainty of dimensional accuracy. The research results shows which design parameters are critically sensitive to the trajectory tracking error and the tendency of the trajectory tracking error caused by them.

The Optimized Integration of Single-baseline GPS Solutions for Network-based Kinematic Positioning (네트워크 기반 키너매틱 위치결정을 위한 단일기선 GPS해의 최적 결합)

  • Choi, Yun-Soo;Bae, Tae-Suk;Lee, Jong-Ki;Kwon, Jay-Hyoun
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.25 no.3
    • /
    • pp.207-213
    • /
    • 2007
  • For several years, although the demand of high accuracy kinematic positing using multiple bases has been increased, most of the commercial GPS processing softwares can provide the single-baseline solutions only. Thus, we studied the methods to improve the accuracy of the kinematic positioning using the network configuration based on the several single-baseline solutions. As discussed in this study, the positioning accuracy as well as the network stability is improved by introducing the geodetic network adjustment theories into the kinematic positioning application. Three different methods to remove the rank-deficiency, RLESS, BLIMPBE and SCLESS, are analyzed in this study. The 3D RMS error has been improved from 3.5cm(max) to 2.1cm using the network-based kinematic positioning, and it is desired to choose BLIMPBE and SCLESS depending on the accuracy of the base stations.