• Title/Summary/Keyword: Kim Jung-Il

Search Result 6,088, Processing Time 0.036 seconds

Evaluation of Setup Uncertainty on the CTV Dose and Setup Margin Using Monte Carlo Simulation (몬테칼로 전산모사를 이용한 셋업오차가 임상표적체적에 전달되는 선량과 셋업마진에 대하여 미치는 영향 평가)

  • Cho, Il-Sung;Kwark, Jung-Won;Cho, Byung-Chul;Kim, Jong-Hoon;Ahn, Seung-Do;Park, Sung-Ho
    • Progress in Medical Physics
    • /
    • v.23 no.2
    • /
    • pp.81-90
    • /
    • 2012
  • The effect of setup uncertainties on CTV dose and the correlation between setup uncertainties and setup margin were evaluated by Monte Carlo based numerical simulation. Patient specific information of IMRT treatment plan for rectal cancer designed on the VARIAN Eclipse planning system was utilized for the Monte Carlo simulation program including the planned dose distribution and tumor volume information of a rectal cancer patient. The simulation program was developed for the purpose of the study on Linux environment using open source packages, GNU C++ and ROOT data analysis framework. All misalignments of patient setup were assumed to follow the central limit theorem. Thus systematic and random errors were generated according to the gaussian statistics with a given standard deviation as simulation input parameter. After the setup error simulations, the change of dose in CTV volume was analyzed with the simulation result. In order to verify the conventional margin recipe, the correlation between setup error and setup margin was compared with the margin formula developed on three dimensional conformal radiation therapy. The simulation was performed total 2,000 times for each simulation input of systematic and random errors independently. The size of standard deviation for generating patient setup errors was changed from 1 mm to 10 mm with 1 mm step. In case for the systematic error the minimum dose on CTV $D_{min}^{stat{\cdot}}$ was decreased from 100.4 to 72.50% and the mean dose $\bar{D}_{syst{\cdot}}$ was decreased from 100.45% to 97.88%. However the standard deviation of dose distribution in CTV volume was increased from 0.02% to 3.33%. The effect of random error gave the same result of a reduction of mean and minimum dose to CTV volume. It was found that the minimum dose on CTV volume $D_{min}^{rand{\cdot}}$ was reduced from 100.45% to 94.80% and the mean dose to CTV $\bar{D}_{rand{\cdot}}$ was decreased from 100.46% to 97.87%. Like systematic error, the standard deviation of CTV dose ${\Delta}D_{rand}$ was increased from 0.01% to 0.63%. After calculating a size of margin for each systematic and random error the "population ratio" was introduced and applied to verify margin recipe. It was found that the conventional margin formula satisfy margin object on IMRT treatment for rectal cancer. It is considered that the developed Monte-carlo based simulation program might be useful to study for patient setup error and dose coverage in CTV volume due to variations of margin size and setup error.

Biological stability of Zirconia/Alumina composite ceramic Implant abutment (지르코니아/알루미나 복합 지대주의 생물학적 안정성에 관한 연구)

  • Bae, Kyu-Hyun;Han, Jung-Suk.;Kim, Tae-Il;Seol, Yang-Jo;Lee, Yong-Moo;Ku, Young;Cho, Ki-Young;Chung, Chong-Pyoung;Han, Soo-Boo;Rhyu, In-Chul
    • Journal of Periodontal and Implant Science
    • /
    • v.36 no.2
    • /
    • pp.555-565
    • /
    • 2006
  • The purpose of the present study is to evaluate the biological stability of the zirconia/alumina composite abutment by histologic and radiographic examination in clinical cases. 17 partially edentulous patients (5 men and 12 women, mean age 47) were treated with 37 implants. The implants were placed following the standard two-stage protocol. After a healing period of 3 to 6 months, zirconia/alumina composite abutments were connected. All radiographs were taken using paralleling technique with individually fabricated impression bite block, following insertion of the prosthesis and at the 3-, 6-, 12 month re-examinations. After processing the obtained images, the osseous level was calculated using the digital image in the mesial and distal aspect in each implant. An ANOVA and t-test were used to test for difference between the baseline and 3-, 6-, 12 months re-examinations, and for difference between maxilla and mandible. Differences at P <0.05 were considered statistically significant. For histologic examination, sample was obtained from the palatal gingiva which implant functioned for 12 months. Sections were examined under a light microscope under various magnifications. Clinically, no abutment fracture or crack as well as periimplantitis was observed during the period of study. The mean bone level reduction(${\pm}standard$ deviation) was 0.34 rom(${\pm}\;0.26$) at 3-months, 0.4 2mm(${\pm}\;0.30$) at 6-months, 0.62 mm(${\pm}\;0.28$) at 12-months respectively. No statistically significant difference was found between baseline and 3-, 6-, 12-months re-examinations (p > 0.05). The mean bone level reduction in maxilla was 0.33(${\pm}0.25$) at 3-months, 0.36(${\pm}0.33$) at 6-months, 0.56(${\pm}0.26$) at 12-months. And the mean bone level reduction in mandible was 0.35(${\pm}0.27$) at 3-months, 0,49(${\pm}0.27$) at 6-months, 0.68(${\pm}0.30$) at 12-months. No statistical difference in bone level reduction between implants placed in the maxilla and mandible. Histologically, the height of the junctional epithelium was about 2.09 mm. And the width was about 0.51 mm. Scattered fibroblasts and inflammatory cells, and dense collagen network with few vascular structures characterized the portion of connective tissue. The inflammatory cell infiltration was observed just beneath the apical end of junctional epithelium and the area of direct in contact with zirconia/alumina abutment. These results suggest the zirconia/alumina composite abutment can be used in variable intraoral condition, in posterior segment as well as anterior segment without adverse effects.

Comparison of the Quality Characteristics between Spring Cultivars of Kimchi cabbage (Brassica rapa L. ssp. pekinensis) (봄 배추 품종별 품질 특성 비교)

  • Lee, Kwang-Hee;Kuack, Han-Seup;Jung, Ji-Won;Lee, Eun-Joon;Jeong, Da-Mi;Kang, Ki-Young;Chae, Kyung-Il;Yun, Seok-Hun;Jang, Mi-Ran;Cho, Sun-Duk;Kim, Gun-Hee;Oh, Ji-Young
    • Food Science and Preservation
    • /
    • v.20 no.2
    • /
    • pp.182-190
    • /
    • 2013
  • This study investigated the quality characteristics between spring cultivars of Kimchi cabbage(Brassica rapa L. ssp. pekinesis). We measured the weight, length, width, formation index, midrib thickness and moisture contents of fresh Kimchi cabbage for characteristics of growth. And we analyzed the free sugar, amino acid, organic acid, mineral, pectin and cellulose contents of fresh Kimchi cabbage. The hardness and firmness were measured for texture of fresh Kimchi cabbage. The weight of 'K-power' cultivar was the highest than other cultivars. The 'Jeongsang' cultivars was the thinnest midrib thickness in cultivars, but it was not significantly different. The free sugar levels of spring cultivars was the highest in 'Chunkwang'. Malic acid content of 'Jeongsang' was significantly different among spring cultivars. Also amino acid content of 'K-power' and 'Chunkwang' were significantly different among spring cultivars Mineral content in 'K-power' and 'Bomaknorang' were greater than that of other cultivars. Especially Na, Ca and Mg contents of 'K-power' and 'Bomaknorang' were higher four times than that of other cultivars. Pectin content of 'Jeongsang' was higher than that of other cultivars, but it was not significantly different. Hardness and Firmness were not significantly different among spring cultivars.

A Study on Stable Isotope Ratio of Circulated Honey in Korea (국내 유통 벌꿀의 안정동위원소 비율에 관한 연구)

  • Cho, Yoon-Jae;Kim, Jae-Young;Chang, Moon-Ik;Kang, Kyung-Mo;Park, Yong-Chjun;Kang, Il-Hyun;Do, Jung-Ah;Kwon, Ki-Sung;Oh, Jae-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.44 no.4
    • /
    • pp.401-410
    • /
    • 2012
  • This study examines the authenticity discrimination of the circulated honey by using stable isotope ratio methods. In the case of domestic honey, the range of ${\delta}^{13}C$ for the samples labeled as pure honey was about -27- -21‰ at the $C_3$ origin, and the range of that for artificial honey was over -19‰ at the $C_4$ origin. The range of ${\delta}^{13}C$ for all imported honey was over -27- -23‰ originating from the $C_3$ plant. According to the nectar-source, ${\delta}^2H$ and ${\delta}^{18}O$ for domestic honey were significantly different for 6 and 5 groups, respectively. However, we could not explain the detailed relationship as well as the geographical feature of ${\delta}^2H$ and ${\delta}^{18}O$. The difference for ${\delta}^2H$ and ${\delta}^{18}O$ in the wide range of latitude, such as between Australia and Canada, was more or less shown. However, it was difficult to find out the trends of ${\delta}^2H$ and ${\delta}^{18}O$ for imported honey versus the geographical information in the similar latitudinal country.

A Study on Heavy Metal Contents in Processed Foods and Their Safety Evaluations (가공식품 중 중금속 함량 및 안전성 평가)

  • Lee, Hyo-Jung;Shim, Jee-Youn;Oh, Hyun-Suk;Jang, Mi-Ran;Lee, Yoon-Ae;Lee, Ryun-Kyung;Kim, Min-A;Lee, Sang-Min;Cho, Tae-Yong;Kang, Ho-Il
    • Korean Journal of Food Science and Technology
    • /
    • v.44 no.1
    • /
    • pp.21-27
    • /
    • 2012
  • This research was carried out as a survey on the contents of lead, cadmium, and arsenic in processed foods (milk, vegetable oil, and margarine) in Korea. The limits of quantification (LOQs) were Pb 0.3 ${\mu}g/kg$, Cd 0.15 ${\mu}g/kg$, and As 0.45 ${\mu}g/kg$ for milk and Pb 0.61 ${\mu}g/kg$, Cd 0.31 ${\mu}g/kg$, and As 0.91 ${\mu}g/kg$ for vegetable oil and margarine. The recoveries were 92.6-98.0% for Pb, 91.2-98.9% for Cd, and 97.9-104.7% for As. The average levels of Pb were 2.395 ${\mu}g/kg$ for milk, and 7.656 ${\mu}g/kg$ for vegetable oil. The average levels of Cd were 0.483 ${\mu}g/kg$ for milk, and 0.380 ${\mu}g/kg$ for vegetable oil, and levels of As were 0.781 ${\mu}g/kg$ for milk, and 1.241 ${\mu}g/kg$ for vegetable oil. The results of this study showed that Pb, Cd, and As contents in the whole samples were less than the maximum residual levels in the processed foods that were specified by the Codex standard.

Development and Application of a Novel Mammalian Cell Culture System for the Biocompatibility and Toxicity of Polymer Films and Metal Plate Biomaterials (고분자필름과 금속막 의료소재에 대한 생체적합성 및 독성 평가를 위한 새로운 세포배양시스템의 개발 및 적용)

  • Kwak, Moon Hwa;Yun, Woo Bin;Kim, Ji Eun;Sung, Ji Eun;Lee, Hyun Ah;Seo, Eun Ji;Nam, Gug Il;Jung, Young Jin;Hwang, Dae Youn
    • Journal of Life Science
    • /
    • v.26 no.6
    • /
    • pp.633-639
    • /
    • 2016
  • Biomaterials including polymer, metal, ceramic, and composite have been widely applied for medical uses as medical fibers, artificial blood vessels, artificial joints, implants, soft tissue, and plastic surgery materials owing to their physicochemical properties. However, the biocompatibility and toxicity for film- and plate-form biomaterials is difficult to measure in mammalian cells because there is no appropriate incubation system. To solve these problems, we developed a novel mammalian cell culture system consisting of a silicone ring, top panel, and bottom panel and we applied two polymer films (PF) and one metal plate (MP). This system was based on the principal of sandwiching a test sample between the top panel and the bottom panel. Following the assembly of the culture system, SK-MEL-2 cells were seeded onto Styela Clava Tunic (SCT)-PF, NaHCO3-added SCT (SCTN)-PF, and magnesium MP (MMP) and incubated at 37℃ for 24 hr and 48 hr. An MTT assay revealed that cell viability was maintained at a normal level in the SCT-PF culture group at 24 or 48 hr, although it rapidly decreased in the SCTN-PF culture group at 48 hr. Furthermore, the cell viability in the MMP culture group was very similar to that of the control group after incubation for 24 hr and 48 hr. Together, these results suggest the sandwich-type mammalian culture system developed here has the potential for the evaluation of the biocompatibility and toxicity of cells against PF- and MP-form biomaterials.

Physiological Changes of Saccharomyces cerevisiae KNU5377 Occurred in the Process of the 48-hour Ethanol Fermentation at 40℃ (40℃ 48시간 에탄올발효 과정 중 일어나는 Saccharomyces cerevisiae KNU5377의 생리 변화)

  • Kwak, Sun-Hye;Kim, Il-Sup;Kang, Kyung-Hee;Lee, Jung-Sook;Jin, Ingn-Yol
    • Journal of Life Science
    • /
    • v.21 no.1
    • /
    • pp.146-154
    • /
    • 2011
  • In this study, physiological changes in a thermotolerant yeast Saccharomyces cerevisiae KNU5377 cell exposed to 48-hour alcohol fermentation at $40^{\circ}C$ were investigated. After 12 hours of alcohol fermentation at $40^{\circ}C$, the $C_{16:1}$ unsaturated acid of plasma membrane increased to 1.5 times more than the $C_{16:0}$ saturated fatty acid, and to about 2 times more for the $C_{18:1}$ unsaturated fatty acid. Fermentation at both $30^{\circ}C$ and $37^{\circ}C$ fermentation showed the same pattern as that done at $40^{\circ}C$. The pH of the alcohol-fermentation medium was reduced to pH 4.1 from a starting pH of 6.0 through the 12-hr fermentation and then maintained this level during the continuing fermentation. With the process of fermentation, the remaining glucose was reduced, but its amount remaining during the $40^{\circ}C$-fermentation was less reduced than those fermented at $30^{\circ}C$ and $37^{\circ}C$. In the study investigating the changing pattern of cellular proteins in the alcohol-fermenting cells, the SDS-PAGE and 2-D data indicated the most expressed dot was phosphoglycerate kinase, which is one enzyme involved in glycolysis. Why this enzyme was most expressed in the cells exposed to unfavorable conditions such as high temperature, increasing concentration of produced alcohol and long time exposure to other stress factors remains unsolved.

Spectral Response of $TiO_{2}$/Se : Te Heterojunction for Color Sensor (컬러센서를 위한 $TiO_{2}$/Se : Te 이종접합의 스펙트럼 응답)

  • Woo, Jung-Ok;Park, Wug-Dong;Kim, Ki-Wan;Lee, Wu-Il
    • Journal of Sensor Science and Technology
    • /
    • v.2 no.1
    • /
    • pp.101-108
    • /
    • 1993
  • $TiO_{2}$/Se : Te heterojunction for color sensor has been fabricated by RF reactive sputtering and thermal evaporation methods onto glass substrate. The optimum deposition condition of $TiO_{2}$ films was such that RF power was 120 W, substrate temperature was $100^{\circ}C$, oxygen concentration was 50%, working pressure was 50 mTorr for the $TiO_{2}$ film thickness of $1000{\AA}$. In this case, the optical transmittance of $TiO_{2}$ film at 550 nm-wavelength was 85%, resistivity was $2{\times}10^9{\Omega}{\cdot}cm$, refractive index was 2.3, and optical bandgap was 3.58 eV. The composition ratio of 0 to Ti by AES analysis was 1.7. When $TiO_{2}$ films were annealed at $400^{\circ}C$ for 30 min. in $O_{2}$ ambient, the optical transmittance of $TiO_{2}$ films at the wavelength range of $300{\sim}580$ nm was improved from 0 to 25%. When Se : Te films were annealed at $190^{\circ}C$ for 1 min., photosensitivity under illumination of 1000 lux was 0.75. The optical bandgap of Se : Te films was 1.7 eV. The structures of Se : Te films were the hexagonal with (100) and (110) orientation. The spectral response of a-Se was improved by the addition of Te, especially in the long wavelength region. The $TiO_{2}$/Se : Te heterojunction showed wide spectral response, and more improved one than that of a-Si film in the blue light region.

  • PDF

Possibility of Repeated Use of Elite Donor Cows for Mass Production of OPU-Derived Embryos (OPU 유래 수정란의 대량생산을 위한 고능력 공란우 반복사용 가능성에 관한 연구)

  • Jin, Jong-In;Choi, Byung-Hyun;Kim, Seong-Su;Park, Bun-Young;Lee, Jung-Gyu;Kong, Il-Keun
    • Journal of Embryo Transfer
    • /
    • v.30 no.3
    • /
    • pp.149-159
    • /
    • 2015
  • This study was designed to know the possibility in repeat uses of elite donor cows for getting mass production of OPU-derived embryo production (OPU-IVP). Ultrasound transvaginal ovum pick-up (OPU) performed in 6 Korean native cows was aged 4 to 10 years old. The aspiration of immature oocytes for OPU derived embryo was carried out 2 times per week, and OPU-IVP of $1^{st}$ period was carried out 22~48 sessions from each donors. And the break time for OPU-IVP of $2^{nd}$ period after $1^{st}$ OPU from each donors were 2~25 months. The OPU-IVP of $2^{nd}$ period each donors conducted total 15~65 times for 2~8 months by an ultrasonographic, was guided follicular aspiration system. The average numbers of collected oocytes, grade 1 + grade 2(G1+G2) oocytes and cleavage embryo from $1^{st}$ period OPU-IVP were significantly differences between donors (p<0.05). Total collected oocytes of donor D were significantly higher compared with donors of A, B, C, E and F (average 17.0 per session vs. 11.2, 10.1, 8.5, 10.2 and 9.6; p<0.05) and also oocytes of G1+G2 were significantly higher compared with r A and D and subsequently to donors of B, C, E and F (average 7.9 and 8.5 per session vs. 5.0, 2.7, 6.0 and 1.6; p<0.05). Cleavage rate of donor D was significantly higher compared with donors of A, B, C, E and F (average 13.1 per session vs. 10.1, 9.1, 6.9, 8.9 and 6.7; p<0.05). The average numbers of OPU-IVP for $1^{st}$ period was significantly higher from donors of B, D and E than those from donors of A, C and F (average 6.5, 7.1 and 6.5 per session vs. 3.5, 4.2 and 2.8; p<0.05). The possibility investigation of $2^{nd}$ OPU-IVP was carried out after 2~25 months rest periods from $1^{st}$ period OPU session. Total average numbers of collected oocytes, cleavages and blastocyst development rates were significantly higher from $1^{st}$ period OPU compared with $2^{nd}$ period one (p<0.05). The OPU-IVP efficiency by break for more embryo production from elite cow was analysis comparing without rest of donor A, under 6 months rest period as B and over 6 months rest period as C and then the average numbers of collected oocytes, cleavages and blastocysts were significantly higher from A group (11.8, 9.5 and 5.2 per session) than those from B and C groups (7.9, 6.2 and 2.6 vs. 9.2, 7.5 and 3.9, p<0.05), and also C group was significantly higher than B group. In conclusion, $1^{st}$ period OPU-IVP was more efficient compared with $2^{nd}$ period repeated uses of donor, and the break times for additional production of embryo on donor were needed more than over 6 months after $1^{st}$ period OPU-IVP. This repeating uses of elite donor cows given more emphasis for getting the opportunity on mass production of elite cow OPU-IVP embryo should be increased G1+G2 possibility of genetic improvement of livestock within short period.

Clinical Features of BCG Lymphadenitis (BCG 림프절염의 임상양상)

  • Kwon, Hyo Jin;Song, Doo Il;Kim, Yun Kyung;Jang, Gi Young;Choi, Byung Min;Lee, Jung Hwa
    • Pediatric Infection and Vaccine
    • /
    • v.16 no.1
    • /
    • pp.80-86
    • /
    • 2009
  • Purpose : This study was performed to determine the clinical course of BCG lymphadenitis. Methods : Between May 2005 and April 2009, the medical records of 33 patients with BCG lymphadenitis were retrospectively reviewed. If needed, needle aspiration was recommended without surgical resection or antituberculous medication. Results : Of the 33 patients who were identified, 21 were males and 12 were females. Among the 33 patients, 32 were full-term babies. The mean age was 6 months (range, 2-35 months) and the most prevalent site of the lesion was the left axilla. BCG lymphadenitis was observed 1-34 months after BCG vaccination, mostly 1-6 months after vaccination. The size of the enlargement was generally 1-3 cm. The strains were identified as French (n=14), Danish (n=7), and Tokyo (n=12). BCG lymphadenitis regressed spontaneously in 19 patients. After 1-5 needle aspirations, 14 patients recovered completely. Complete regression of lymphadenitis was recorded over an average period of 4 months. Conclusion : Clinicians need to be aware of the clinical features of BCG lymphadenitis. For management of BCG lymphadenitis, regular follow-up with observation should be the mainstay. Needle aspiration is a safe and easy treatment for suppurative BCG lymphadenitis.

  • PDF