• Title/Summary/Keyword: Kerr microscope

Search Result 25, Processing Time 0.024 seconds

THE EFFECT OF INTRACANAL BASE ON PREVENTION OF APICAL LEAKAGE OF BLEACHING AGENTS (무수치 표백술에서 근관내 Base가 표백약제의 누출 방지에 미치는 영향)

  • Choi, Seung-Ho;Ro, Byeng-Duck;Park, Sung-Ho;Lee, Seung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.3
    • /
    • pp.453-464
    • /
    • 1999
  • The non-vital bleaching technique has been used widely as a very effective treatment method on discolored non-vital teeth. But periodontal tissue deterioration and cervical external root resorption have been reported because of the high toxicity of hydrogen peroxide in bleaching agents. So in previous studies, placement of base over the root canal obturation prior to bleaching has been suggested in order to prevent microleakage of bleaching agents, however, the effectiveness of base is still controversial. The purpose of this study was to evaluate the effects of base and root canal sealer on prevention of leakage of bleaching agents in non-vital bleaching. Fifty-two extracted sound teeth with single root were used. For root canal obturation, Tubuli seal$^{(R)}$(Kerr Co., USA) was used in 39 teeth and in others, AH-26$^{(R)}$(De Trey Dentsply, Inc., Switzerland) was used as a root canal sealer. 26 teeth among the teeth obturated with Tubuli seal$^{(R)}$ were divided into two groups, and Dentin cement$^{(R)}$(GC corp., Japan) and JRM$^{(R)}$(De Trey Dentsply, Inc. Germany) were used in each group as a intracanal base. In all teeth, non-vital bleaching using bleaching agent mixed with methylene blue dye was performed and all specimens were stored in $37^{\circ}C$ water bath for 72 hours. After sectioning longitudinally, the depth of dye leakage was measured with digital vernier calipers under the stereobinocular microscope using ${\times}40$ magnification. It can be concluded as follows: 1. The microleakage of bleaching agent was observed ill all groups regardless of type of the base and the sealer. 2. The microleakage in the groups using AH-26$^{(R)}$ as a sealer was significantly reduced (p<0.05). 3. In the groups with intracanal base, micro leakage was observed through almost the whole depth of the base and there was no significant difference between Dentin cement$^{(R)}$ and IRM$^{(R)}$ group(p>0.05). In conclusion, all the basing materials and the sealers in this study did not prevent the microleakage of bleaching agent. Therefore further studies and attempts to seal off the pulp chamber will be necessary.

  • PDF

MICROTENSILE BOND STRENGTH OF SELF-ETCHING AND SELF-ADHESIVE RESIN CEMENTS TO DENTIN AND INDIRECT COMPOSITE RESIN (간접 복합레진 합착 시 자가부식형과 자가접착형 레진시멘트의 상아질에 대한 미세인장 결합강도)

  • Park, Jae-Gu;Cho, Young-Gon;Kim, Il-Sin
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.2
    • /
    • pp.106-115
    • /
    • 2010
  • The purpose of this study was to evaluate the microtensile bond strength (${\mu}TBS$), failure modes and bonding interfaces of self-etching and three self-adhesive resin cements to dentin and indirect composite resin. Cylindrical composite blocks (Tescera, Bisco Inc.) were luted with resin cements (PA: Panavia F 2.0, Kuraray Medical Inc., RE: RelyX Unicem Clicker, 3M ESPE., MA: Maxem, Kerr Co., BI: BisCem, Bisco Inc.) on the prepared occlusal dentin surfaces of 20 extracted molars. After storage in distilled water for 24 h, $1.0\;mm\;{\times}\;1.0\;mm$ composite-dentin beams were prepared. ${\mu}TBS$ was tested at a cross-head speed of 0.5 mm/min. Data were analyzed with one-way ANOVA and Tukey's HSD test. Dentin sides of all fractured specimens and interfaces of resin cements-dentin or resin cements-composite were examined at FESEM (Field Emission-Scanning Electron Microscope). In conclusion, PA and RE showed higher bond strength and closer adaptation than MA and BI when indirect composite blocks were luted to dentin using a self-etching and three self-adhesive resin cements.

Fracture resistance and marginal fidelity of zirconia crown according to the coping design and the cement type (코핑 디자인과 시멘트에 따른 지르코니아 도재관의 파절 저항성)

  • Sim, Hun-Bo;Kim, Yu-Jin;Kim, Min-Jeong;Shin, Mee-Ran;Oh, Sang-Chun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.3
    • /
    • pp.194-201
    • /
    • 2010
  • Purpose: The purpose was to compare the marginal fidelity and the fracture resistance of the zirconia crowns according to the various coping designs with different thicknesses and cement types. Materials and methods: Zirconia copings were designed and fabricated with various thicknesses using the CAD/CAM system (Everest, KaVo Dental GmbH, Biberach., Germany). Eighty zirconia copings were divided into 4 groups (Group I: even 0.3 mm thickness, Group II: 0.3 mm thickness on the buccal surface and the buccal half of occlusal surface and the 0.6 mm thickness on the lingual surface and the lingual half of occlusal surface, Group III: even 0.6 mm thickness, Group IV: 0.6 mm thickness on the buccal surface and the buccal half of occlusal surface and the 1.0 mm thickness on the lingual surface and the lingual half of occlusal surface) of 20. By using a putty index, zirconia crowns with the same size and contour were fabricated. Each group was divided into two subgroups by type of cement: Cavitec$^{(R)}$ (Kerr Co, USA) and Panavia-$F^{(R)}$ (Kuraray Medical Inc, Japan). After the cementation of the crowns with a static load compressor, the marginal fidelity of the zirconia crowns were measured at margins on the buccal, lingual, mesial and distal surfaces, using a microscope of microhardness tester (Matsuzawa, MXT-70, Japan, ${\times}100$). The fracture resistance of each crown was measured using a universal testing machine (Z020, Zwick, Germany) at a crosshead speed of 1 mm/min. The results were analyzed statistically by the two-way ANOVA and oneway ANOVA and Duncan's multiple range test at $\alpha$=.05. Results: Group I and III showed the smallest marginal fidelity, while group II demonstrated the largest value in Cavitec$^{(R)}$ subgroup (P<.05). For fracture resistance, group III and IV were significantly higher than group I and II in Cavitec$^{(R)}$ subgroup (P<.05). The fracture resistances of Panavia-$F^{(R)}$ subgroup were not significantly different among the groups (P>.05). Panavia-$F^{(R)}$ subgroup showed significantly higher fracture resistance than Cavitec$^{(R)}$ subgroup in group I and II (P<.05). Conclusion: Within the limitation of this study, considering fracture resistance or marginal fidelity and esthetics, a functional ceramic substructure design of the coping with slim visible surface can be used for esthetic purposes, or a thick invisible surface to support the veneering ceramic can be used depending on the priority.

A COMPARATIVE STUDY ON THE MICROLEAKAGE OF PRVENTIVE RESIN RESTORATION USING FLOWABLE COMPOSITE RESIN (유동성 복합 레진을 적용한 예방적 레진 수복물의 미세 누출 양상에 관한 비교 연구)

  • Park, Heon-Jeong;Kim, Jong-Soo;Kim, Yong-Kee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.27 no.3
    • /
    • pp.419-430
    • /
    • 2000
  • The purpose of this study was to compare the microleakage pattern of preventive resin restoration using conventional composite resin and flowable composite resin that recently developed. 60 sound premolar teeth were allocated to three groups. Flowable composite resin was used for the experimental groups(Group I and II) and conventional resin for the control group(Group III). After composite filling and sealant application, all teeth were thermocycled and evaluated for microleakage under light microscope. Additionally, a variety of voids formed inside restorations were also evaluated. Data were analyzed statistically using Kruskal-Wallis test and/or Mann-Whitney U-test. The results of the present study were as follows. 1. Microleakage found in all samples was only limited to the interface of restoration margin and enamel. 2. The flowable composite resin groups (Group I, II) generally showed less microleakage than control groups (conventional preventive resin restoration) (p<0.05) 3. Various types of voids were observed in most specimens. Especially, there was a tendency for more and larger voids to be found in group I, II than group III (p<0.05).

  • PDF

Effect of Ethanol Addition on Efficacy of Dental Adhesive (에탄올의 첨가가 치과용 접착제의 효율에 미치는 영향)

  • Min, Jeong-Bum;Kim, Hee-Jung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.2
    • /
    • pp.161-174
    • /
    • 2011
  • The purpose of this study was to evaluate the effect of ethanol addition on efficacy of two-step total-etch adhesive under over-wet condition by measurement of remaining volatile part (RVP), microtensile bond strength (${\mu}TBS$), and degree of conversion (DC). Two-step total-etch adhesive, Optibond Solo Plus (Kerr, Orange, USA), was used. Experimental groups were divided into 8 groups: Group 1 (only 10 ${\mu}l$ adhesive), Group 2 (mixture of 3 ${\mu}l$ distilled water and 10 ${\mu}l$ adhesive), From Group 3 to Group 8 (mixture of 3 ${\mu}l$ distilled water, 10 ${\mu}l$ adhesive, and ethanol added in 1 ${\mu}l$ increment from 1 ${\mu}l$ to 6 ${\mu}l$). The mixtures were placed on slide glass and evaporated for 10 s, 30 s, and 60 s by air-drying. The weight of RVP was measured by precision weight. Same procedures were performed for ${\mu}TBS$ test and measurement of DC. The condition of mixed solution was observed under light microscope. For RVP weight, the weights of experimental groups except for group 1 decreased with the increase of air-drying time (p<0.05). The DC increased with the increase of air-drying time in only group 5 and 6 (p<0.05). The ${\mu}TBS$ increased with the increase of air-drying time in group only 5, 6, and 7 (p<0.05). The phase separation was examined and water blisters were diminished with the increase of air-drying time in group 5, 6, 7, and 8. Within the limits of this study, ethanol additionally applied to adhesive decreased RVP and increased DC and ${\mu}TBS$ under over-wet condition. It was shown that the addition of ethanol to two-step total-etch adhesive under over-wet condition would remove water and increase the efficacy of adhesive.