• 제목/요약/키워드: Kerr microscope

검색결과 25건 처리시간 0.019초

아몰퍼스 자성박막의 센싱기능에 관한 연구 (Study on the Sensing Function in Amorphous Magnetic Thin Films)

  • 김남규;진성빈;신용진;임재근;서강수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1996년도 춘계학술대회 논문집
    • /
    • pp.27-30
    • /
    • 1996
  • In this paper, we prove through the experiments the possibility that Co-amorphous magnetic films can be used as high sensibility materials. We fabricate amorphous film of Fe$\sub$4.7/Co$\sub$74.3/Si$_2$B$\sub$19/ by using sputtering method at high frequency. Then, we not only measure the magnetic Properties of the annealed samples, but also observe the magnetic domain by using an Kerr effect optical-microscope. As the result, we find that the samples have high sensibility

  • PDF

A newly-designed method to measure liner polymerization shrinkage

  • Ikejima, Iwao;Matsuzawa, Norihiko;Momol, Yasko;Kohno, Atsushi
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2003년도 제120회 추계학술대회 제 5차 한ㆍ일 치과보존학회 공동학술대회
    • /
    • pp.604-604
    • /
    • 2003
  • I. Objectives Newly-designed method was evaluated to measure the linear polymerization shrinkage of light-cured resin composites. II. Materials and Methods A resin composite(Clearfil AP-X, Kuraray, Japan) was filled into a vinyl-polysiloxan mold(1 to 8mm-depth, and 7mm-diameter). As indicators, 4 beads(Retention Beads 2 SS, GC, Japan;particle size $200{\;}\mu\textrm{m}$) were placed diagonally on the resin surface of a mold. The coordinates (x, y, z, pasition) of each indicator were measrued by a measuring-microscope after which the resin surface was irradiated by a curing-light source(Optilux 500, Demetron/Kerr, USA) for 40 sec. After 20 sec the coordinates were again measured.(omitted)

  • PDF

강자성 Co0.5Fe0.5 합금 박막에서의 자화역전현상 연구 (Study on Magnetization Reversal Behavior in Ferromagnetic Co0.5Fe0.5 Alloy Films)

  • 류광수
    • 한국자기학회지
    • /
    • 제25권6호
    • /
    • pp.180-184
    • /
    • 2015
  • 실시간 자구 관찰이 가능한 광자기 현미경을 이용하여 강자성 나노자성체 CoFe 박막에서의 자화역전현상을 연구하였다. 흥미롭게도, 박막의 두께가 증가함에 따라 자구벽의 운동이 단일 자구벽의 운동 성향에서 무작위적인 자구들의 역전 성향으로 변함을 알 수 있었다. 또한, 자구벽 운동에서의 자구들의 점프사이즈들의 통계적인 해석 결과, CoFe박막에서의 자구역전현상이 임계지수 ${\tau}{\sim}1.33$를 가지는 임계축척현상을 보임을 알 수 있었다.

Primer Bonding agent, 복합레진 내의 볼소의 법랑질에 대한 항우식 작용 (THE ANTICARIOGENIC EFFECT OF F IN PRIMER, BONDING AGENT AND COMPOSITE RESIN IN THE CAVOSURFACE ENAMEDL AREA)

  • 박성호
    • Restorative Dentistry and Endodontics
    • /
    • 제21권2호
    • /
    • pp.635-641
    • /
    • 1996
  • This study was designed to evaluate the anti cariogenic effect of F in primers, bonding agents, composite resins or glass ionomer cements in enamel. Twenty-five extracted teeth were selected and a cavity was prepared on either the buccal or the lingual surface of each tooth. After pumicing and etching, the samples were divided into 5 groups. In group A, the samples were primed, bonded and filled with ART bond and Brilliant Enamel (Coltene, Switzerland). Group B composed of Optibond and Herculited XRV (Kerr, USA), group C composed of Syntac and Tetric(Vivadent, Lichtenstein), and group D composed of Scotch-bond Multipurpose and Z 100 (3M, YSA). In group E, the samples were filled with glass ionomer cement (Fuji II LC, Japan), All surfaces except the 2mm beyond the cavosurface margin of the sample were protected, and samples were then put into an acid buffer for 3 days to develop the initial caries. The samples were then sectioned through the filling body into thin wafers and then examined with a polarizing microscope under water imbibition. The fluoride in primer, bonding agent, or composite filling material did not prevent the initial caries in the enamel area adjacent to the filling body whereas the fluoride in the glass ionomer did prevent the initial stage caries.

  • PDF

각종 근관충전용 시멘트의 미세누출에 관한 연구 (A STUDY ON THE MICROLEAKAGE OF ROOT CANAL SEALERS)

  • 조지선;황호길;조영곤
    • Restorative Dentistry and Endodontics
    • /
    • 제21권1호
    • /
    • pp.202-217
    • /
    • 1996
  • The purpose of this study was to compare the degree of microleakage of Glass-Ionomer root canal sealer possessed several enviable properties with that of the other sealers and to evaluate clinical performance. One hundred twenty single-rooted teeth were used in this experiment. The teeth were cleaned mechanically and immersed for 24 hours in 5.25% sodium hypochlorite and clinical crowns then were removed. After the root canals were instrumented using a step-back technique. one hundred twenty single-rooted teeth were divided into five groups of 24 in each. Group 1 : Tubli-Seal(Kerr Co., MI, U.S.A/ZOE-based), lateral condensation Group 2 : Sealapex(Kerr/Sybron, Romulus, MI/ $Ca(OH)_2$-based), lateral condensation Group 3 : AH 26(De Trey Co., Zurich Switzerland/Resin-based), lateral condensation Group 4 : Ketac-Endo(ESPE GMBH & CO. KG Seefeld:oberbay. Germany/ Glass Ionomer Cement-based), lateral condensation Control group : no sealer. lateral condensation And then. the root canals were obturated by lateral condensation technique with gutta-percha and experimental sealers. The control group were obturated without sealer. The teeth were placed in a vacuum chamber for 15 minutes and immersed 2% methylene blue under vacuum for 15 minutes. The teeth were passively stained for 1 week and 2 weeks and were cleared and evaluated for linear dye leakage using Tool maker's microscope(${\times}200$). The results were as follows: 1. There were statistically significant differences in the degree of dye penetration between the control group and experimental groups(p<0.05). 2. In the experimental groups, Sealapex($1.2871{\pm}0.9180mm$) exhibited the lowest mean value of dye penetration, followed by Ketac-Endo($1.4432{\pm}0.8082mm$), AH 26($1.5030{\pm}0.7752mm$) and Tubli-Seal($1.6458{\pm}1.0292mm$)(p>0.05). 3. There were statistically significant differences in the variation of microleakage between 1 week and 2weeks in Tubli-Seal and Seal apex groups (p<0.05). 4. The degree of dye penetration of all groups were increased as the time elapsed and AH 26 showed the lowest variation(+0.11) and Tubli-Seal(+ 1.03) showed the highest variation (p<0.001).

  • PDF

상아질 표면 젖음성이 수종 자가접착레진시멘트의 인장접착강도에 미치는 영향 (EFFECT OF DENTIN SURFACE WETNESS ON TENSILE BOND STRENGTH OF SELF ADHESIVE RESIN CEMENTS)

  • 윤성영;박세희;김진우;조경모
    • Restorative Dentistry and Endodontics
    • /
    • 제34권2호
    • /
    • pp.113-119
    • /
    • 2009
  • 본 연구의 목적은 다른 표면 젖음성을 갖는 상아질에 대한 수종의 자가접착레진시멘트의 인장접착강도를 비교하고자 하는 것이다. 이번 실험을 위해 Rely-X Unicem (3M, ESPE, St. Paul, MN, USA), Embrace Wetbond (Pulpdent, Oakland, MA, USA), Maxcem (Kerr, Orange, CA, USA) 3 종의 자기접착레진시멘트를 사용하였다. 발거한 상, 하악 대구치 60개를 미세절단기 (Acutom P-50, Struers, Copenhagen, Benmark)를 이용해 한 치아에서 $2mm{\times}2mm{\times}7mm$의 치아 시편 두개씩 얻었다. 상아질 표면을 건조 그룹은 10초간 강한 공기로 건조시켰고, 습윤 그룹은 과잉의 수분을 2 초간 거즈로 압박해 제거하였다. 상아질 표면의 젖음성을 달리한 시편에 자가접착레진시멘트를 접착한 후 상온의 상대습도 100% 상태에서 24시간 보관했고, 만능시험기 (EZ Test, Shimadzu corporation, Kyoto, Japan)를 이용해 인장접착강도를 측정했고, 분리된 접착면의 파절양상을 근관 치료용 현미경 (OPMI pro, Carl Zeiss, Oberkochen, Germany)을 이용해 20 배의 배율로 관찰하였다. $SPSS^{TM}$ Ver 10.0 (SPSS Inc., Chicago, IL, USA)을 사용하여 동일한 자가접착레진시멘트에서 상아질 젖음성에 따른 인장접착강도를 T-test로 비교하였으며, 각 자가접착레진시멘트간의 인장접착강도를 One way ANOVA test로 비교 분석하고 95% 유의수준에서 Scheffe's test로 사후검정 하였다. 실험 결과 자가접착레진시멘트의 인장접착강도는 상아질 젖음성에 영향을 받지 않았으며, 상아질 표면 젖음성과 상관없이 Maxcem의 인장접착강도가 Unicem과 Embrace의 인장접착강도보다 유의성 있는 낮은 값을 나타내었다. 또한 모든 시편의 분리된 접착면은 접착실패 양상을 나타내었다. 이상의 실험 결과로 볼 때 자가접착레진시멘트는 상아질 표면 젖음성에 상관없이 사용할 수 있을 것이라고 생각된다.

수직 자기 이방성을 갖는 Pt/Co/Pt 자성 박막의 세차 운동 측정 및 분석 (Precessional Motion of Ferromagnetic Pt/Co/Pt Thin Film with Perpendicular Magnetic Anisotropy)

  • 윤상준;이재철;최석봉;신경호
    • 한국자기학회지
    • /
    • 제21권6호
    • /
    • pp.204-207
    • /
    • 2011
  • 본 연구에서는 극초고속 시간 대역의 자성 동역학을 탐구하기 위해, 시간 분해능을 가진 주사식 광자기 현미경을 개발하였다. 타이타늄:사파이어 레이저를 펌프-프루브 방식으로 사용하여, 0.1 피코초의 시간 분해능을 확보하였다. 이를 이용하여 Co 층의 두께를 바꾸어가며 Pt/Co/Pt 자성 박막 시료에서의 자성 동역학을 측정하였다. 펌프 레이저로 시료를 직접 가열하는 경우, 모든 시료는 수 피코초 내에 탈자화가 일어났다. Co 층이 두꺼운 두 시료에서는 자화의 세차 운동을 관측할 수 있었고, 란다우-리프쉬츠-길버트 방정식으로부터 각 시료의 길버트 감쇠 상수를 구하였다.

서로 다른 거칠기의 복합레진에 표면 강화제 도포시 표면 거칠기의 변화 (Effect of surface sealant on surface roughness of dental composite with different surface roughness)

  • 신동아;진선주;배꽃별;황인남
    • 구강회복응용과학지
    • /
    • 제39권4호
    • /
    • pp.195-203
    • /
    • 2023
  • 목적: 본 연구는 서로 다른 필러를 가지는 복합레진에서 표면 연마 정도에 따라 수종의 레진 표면 강화제(Surface sealant)를 도포했을 때 복합레진의 거칠기에 미치는 영향에 대해 연구해 보고자 한다. 연구 재료 및 방법: 미세입자형 복합레진(Metafil CX, Sun Medical Co.)과 혼합형 복합레진(AeliteTM LS posterior, Bisco)을 사용하여 직경 8 mm, 높이 4 mm의 시편을 레진당 60개씩 제작하고, 3개 군으로 나누어 주수 하에 600, 1000, 2000 grit 사포(Tamiya finishing abrasives, Tamiya Inc.)로 연마하였다. 연마된 표면의 표면 조도(Ra)값은 Surface Roughness Tester (SJ-301, Mytutoyo)를 이용해 측정하였으며 연마된 각 시편에 레진 표면 강화제인 BisCoverTM LV (Bisco), Optiguard® (Kerr), and Seal-n-ShineTM (Pulpdent)를 각각 제조사의 지시에 따라 도포하였다. 레진 표면 강화제 처리 전과 후에 시편의 표면 조도를 측정하였으며 주사전자현미경(JSM-7500, JEOL)과 원자현미경(MultiMode IV, Veeco Instruments)으로 관찰하였다. 결과: 600 grit 사포로 연마한 후 레진 표면 강화제를 처리한 군은 도포 전보다 더 낮은 표면 조도(Ra)값을 보였으나(P < 0.05), 1000, 2000 grit으로 연마한 군에서는 도포 전 후 간에 통계적으로 유의한 차이를 보이지 않았다. 레진 표면 강화제 제품 간 뚜렷한 거칠기 차이는 나타나지 않았다. SEM과 AFM으로 시편을 관찰 시 마무리와 연마 후 레진 표면에 형성된 미세한 결함이 레진 표면 강화제를 처리한 후 현저히 줄어드는 양상을 보였다. 결론: 본 연구 결과, 마무리와 연마 후 복합레진 표면이 거친 경우에는 레진 표면 강화제의 도포가 미세한 결함을 채워서 거칠기에 영향을 줄 수 있지만 복합레진 표면의 연마 상태가 우수한 경우 레진 표면 강화제의 도포가 거칠기에 크게 영향을 주지 않음을 보여준다.

열시효 처리에 따른 상아질 접착 계면의 탄성계수의 변화 비교 (Comparison of the elastic modulus among three dentin adhesives before and after thermocycling)

  • 장주혜;이인복;조병훈;김혜영;손호현
    • Restorative Dentistry and Endodontics
    • /
    • 제33권1호
    • /
    • pp.45-53
    • /
    • 2008
  • 본 연구는 현재 시판되고 있는 여러 개의 상아질 접착제를 임상 술식에서와 같은 방법으로 사용한 후 열 시효처리를 통해 노화 과정을 재현한 다음 접착 계면의 탄성계수를 측정함으로써 가수분해에 따른 물성변화를 관찰 비교하고자 했다. 발거 한 지 2 주일 이내인 영구 대구치 21 개의 상아질 표면이 노출되도록 삭제하였다. 각각 7개의 치아에 시판되고 있는 3가지 상아질 접착제 (OptiBond FL, Clearfil SE, Xeno III)를 적용한 뒤 광중합 복합 레진(Premisa, Kerr, Orange, CA, USA) 를 1 mm 두께로 쌓아 올렸다. 각 치아를 이등분하여 절반 시편은 100,000회의 열 시효 처리를 가하도록 했다. Nanoindentation test를 통하여 각 시편의 adhesive layer와 hybrid layer의 탄성계수를 측정, 비교하였다. 열시효 처리 후 Xeno III군의 탄성계수가 통계학적으로 유의할 만한 감소를 보였다 (p < 0.05). Hydrophilic monomer를 많이 함유한 one-step self-etch adhesive system은 다른 제품에 비해 가수분해에 취약하여 이에 따른 물성 변화를 보이는 것으로 추정되며, 궁극적으로 수복물의 내구성에 영향을 미칠 것으로 여겨진다.

삼층박막 구조의 PHR 센서를 이용한 자기 박테리아 감지 (Detection of Magnetic Bacteria Using PHR Sensors with Trilayer Structure)

  • 유상엽;임병화;송인철;김철기;오선종
    • 한국자기학회지
    • /
    • 제23권6호
    • /
    • pp.200-204
    • /
    • 2013
  • 마그네트론 스퍼터를 이용하여 반강자성/비자성/강자성의 삼층박막 $50{\mu}m{\times}50{\mu}m$ 크기의 십자 형태의 PHR 자기센서를 제작하고, 도메인스코프를 이용하여 외부자기장에 의한 PHR 센서의 자화거동을 관찰하였다. 또 자기저항 신호로부터 센서 특성 및 자기 민감도를 측정하였다. 삼층 구조의 PHR 센서에서 자기이력곡선 이동으로부터 측정한 교환결합력은 20 Oe였으며, $20^{\circ}$에서 자기 민감도는 $20{\mu}V/Oe$이였다. 이를 이용하여 자기 모멘트가 $10^{-13}emu$인 자기 박테리아를 $1{\times}10^3$개 정도의 분해능까지 측정하였으며, 또한 자기 민감도와 박테리아에 의한 출력 전압을 이용해 계산한 결과 박테리아 한 마리가 가지는 자기장의 크기는 $5{\times}10^{-5}Oe$이였다.