• Title/Summary/Keyword: Kangwon-do

Search Result 1,397, Processing Time 0.031 seconds

Preliminary Study for Tidal Flat Detection in Yeongjong-do according to Tide Level using Landsat Images (Landsat 위성을 이용한 조위에 따른 영종도 갯벌의 면적 탐지에 관한 선행 연구)

  • Lee, Seulki;Kim, Gyuyeon;Lee, Changwook
    • Korean Journal of Remote Sensing
    • /
    • v.32 no.6
    • /
    • pp.639-645
    • /
    • 2016
  • Yeongjong-do is seventh largest island in the west coast of Korea which is 4.8 km away in the direction of south-west from Incheon. The mudflat area around the Yeongjong-do has variable dimension according to tide level. In addition, Yeongjong-do is important area with high environmental value as wintering sites for migratory birds. The mudflat of Yeongjong-do is also meaningful region because it is used as place of education and tourist attraction. But, there are increasing concerns about preservation of mudflat area caused by artificial development such as land reclamation project and Incheon airport construction. In this paper, mudflat area was detected using Landsat 7 ETM+ images that United States Geological Survey (USGS) is providing the data in 16 days period. The false color composite was made from band 7, 5, and 3 that could dividing boundary between water and land for the purpose of appearance of boundary line in mudflat region. This area was calculated using results of classification based on false color composite images and was digitized through repetitive algorithm during research of period. Therefore, the change of northeastern area in Yeongjong-do was detected according to tide level during 16 years from 2000 to 2015 on the basis of providing period at tide station. This paper will expect as indicator for range of area in same tide level prior to the start of the research for preservation of mudflat. It will be also scientific grounds about change of mudflat area caused by artificial development.

The pre-hospital analysis of patients with suicide attempts in Gangwon-do (일개 도 지역 자살 시도 환자에 대한 병원전 단계 분석)

  • Kim, Gi Whan;Cho, Jun Hwi;Moon, Joong Bum;Park, Chan Woo;Shin, Myoung Cheol;Kim, Ka Eul;Lee, Joon Seok;Park, Yoon Soo;Ohk, Taek Geun
    • Journal of The Korean Society of Emergency Medicine
    • /
    • v.29 no.6
    • /
    • pp.687-698
    • /
    • 2018
  • Objective: This study examined the characteristics of suicidal attempters, including pre-hospital patients and those who visited the emergency department. Methods: Suicidal attempters who had been reported to the 119 call center were selected between July 2015 and June 2016. Sex, age, place, methods of suicidal attempt, season, time, and suicide success rate were reviewed in the fire center records. Results: A total 961 suicide attempters were enrolled. Among them, 53.6% were males who had an approximately 2.6 times higher mortality than that of females (9.2%). The most preferred place to commit suicide was the home in both sexes (68.0% in male, 82.8% in female) and the most preferred methods was drug intoxication, particularly pesticide. The method with the highest mortality was hanging and the lowest was self-harm. The season of the highest mortality was spring. The success of suicide and the time variation were similar. Most of the un-transferred patients also selected fatal suicide attempts compared to transfer patients. Conclusion: Unlike previous studies, this study includes information on un-transferred patients. Overall, the probability of death was highest as more than 50 years men chose hanging as a method, which had an influence on the un-transferred patients group.

A Study on the Space Composition of Welfare Center for the Old who stay at home by remodeling Closed School -Focused on Samcheok district of Kangwon-do- (폐교를 활용한 재가노인복지센터의 공간구성에 관한 연구 - 강원도 삼척지역을 중심으로 -)

  • Chai, Hee-Jai;Rim, Sang-Kyu
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.10 no.4
    • /
    • pp.1-8
    • /
    • 2008
  • The policy that do so the Geritol generation with advanced age generation's increase may be not estranged and can human down life is necessary times. The Medical treatment and welfare service is essential, and the aged support domiciliary care facility in the rudiments step more expand must. It is real condition that Kangwon-do's number of closed school appears by many things thirdly in whole country and the post management countermeasure is urgent. Because this research chooses the closed school by way to solve the closed school problem that happen by the child of school age decrease the farming and fishing villages or small city and the shortage problem of old people's welfare facilities by population graying at the same time. There is the purpose to grope practical use the possibility of local closed school as welfare center for the old who stay at home present remodeling to welfare facilities for the old man. Keeping the structure condition of a closed school maximum, the welfare center for the old who stay at home by remodeling a closed school ultimately proposed.

  • PDF

Waterproofing Mechanism of Hardened Cement Paste with Waterproofing Materials (구체방수제가 혼입된 시멘트 경화체의 방수 메카니즘)

  • Kang, Hyun Ju;Song, Myong Shin;Park, Jong Hun;Jeon, Se Hoon;Lee, Sung Hyun
    • Journal of the Korean Ceramic Society
    • /
    • v.50 no.1
    • /
    • pp.25-30
    • /
    • 2013
  • The pore volume of hardened cement with waterproofing materials is lower compared to that of hardened cement without waterproofing materials. Thus, fewer gaps will appear by means of chemical reactions between $Ca^{2+}$ ions in hardened cement and water, solutes, and other ions. Due to the selective permeability, the osmotic pressure of hardened cement can change due to physical effects such as the reduction of the pore volume and the reduction in the number of pores, as well as by the electrochemical reaction between water, solutes, other ions and $Ca^{2+}$ ions in hardened cement. Of course, these factors do not have independent effects but instead a combined complex effect. Accordingly, we studied changes in the osmotic pressure due to the difference in the pore structure of hardened cement. A pore size smaller than 1 nm in hardened cement had only a slight effect on the osmotic pressure, whereas a pore size larger than 1 nm had a direct effect on the osmotic pressure.

Variations of Disinfection By-products in a Chlorinated Drinking Water Distribution System

  • Lee, Soo-Hyung;Park, Jeong-Kun;Lee, Hyung-Jun;Kim, He-Kap
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • v.4 no.2
    • /
    • pp.71-78
    • /
    • 2000
  • The chlorination of municipal drinking water supplies leads to the formation of so-called disinfection by-products(DBPs), many of which have been reported to cause harmful health effects based on animal studies. This study was conducted: 1) to observe seasonal changes in the major DBPs at four sampling sites on a drinking water distribution system located in Chunchon, Kangwon Do; and 2) to examine the effects of major water quality parameters on the formation of DBPs. During the field sampling, the water temperature, pH, and total and free chlorine residuals were all measured. The water samples were then analyzed for total organic carbon(TOC) and eight disinfection by-products in the laboratory. Chloroform, dichloroacetic acid, and trichloroacetic acid were the major constituents of the measured DBPs. The concentrations of the total DBPs were highest in fall, particularly in October, and lowest in summer. The concentrations of the total DBPs increased with increasing TOC concentrations. Multiple regression analyses showed that the concentrations of chloroform, bromodichloromethane, and chloral hydrate were linearly correlated with the pH. Other water parameters were not included in the regression equations. Accordingly, these results suggest that TOC and pH are both important factors in the formation of DBPs.

  • PDF

Oxygen Supersaturation in Korean Streams as a Stress Factor to Fish (어류 스트레스 요인으로서 우리나라 하천의 산소과포화 실태)

  • Lee, Saeromi;Lee, JaeYong;Choi, Jaeseok;Kim, Sunjung;Ahn, Buyoung;Kim, Bomchul
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.2
    • /
    • pp.213-218
    • /
    • 2012
  • Abnormal dissolved oxygen concentration in aquatic habitat, both depletion and supersaturation, can be stress factor to aquatic animals. In this study the nationwide distribution of oxygen supersaturation was analyzed for three categories of streams (43 urban streams, 15 rural streams, and 14 forest streams) by using monitoring network data of the Korean Ministry of Environment. From the distribution analysis 30% of urban streams showed hyperoxic condition of eutrophic level, while no forest stream showed hyperoxic condition. The physiological effect of hyperoxia on fish was examined using two species of fish Zacco koreanus, which resulted in higher concentration of a stress hormone (cortisol) in fish exposed to hyperoxic concentration (196%) of oxygen. This study shows that hyperoxic condition is ubiquitous in urban and rural Korean streams, and it can be a stress factor to aquatic animals.

Productivity and Cost of Tree-length Harvesting Using Cable Yarding System in a Larch (Larix leptolepis) Clear-cutting Stand

  • Jeong, Eungjin;Cho, Koohyun;Cho, Minjae;Choi, Byoungkoo;Cha, Dusong
    • Journal of Forest and Environmental Science
    • /
    • v.33 no.2
    • /
    • pp.147-153
    • /
    • 2017
  • The purpose of this study was to examine productivity and cost of tree-length harvesting using cable yarding system in a larch (Larix leptolepis) clear-cutting stand located in Pyeongchang-gun, Gangwon-do. We used tree-length harvesting method using cable yarding system with a tower yarder HAM300. The productivity was $17.6m^3/hr$ for felling, $12.4m^3/hr$ for delimbing, $4.2m^3/hr$ for yarding, and $8.1m^3/hr$ for processing. The total cost of the harvesting system was $48,381won/m^3$, which was majorly composed of yarding operation cost, at $40,169won/m^3$ (79.3%), while felling had the lowest cost at $1,154won/m^3$ (4.1%). Major factors affecting felling and processing productivity was tree volume and the number and thickness of branches for delimbing productivity. In addition, we suggest that training and education for machine operators were critical to improve yarding productivity.

Seismic Performance Evaluation of An Old School Building Through Linear Analysis (선형구조해석을 통한 노후된 학교시설 내진성능평가)

  • LEE, Do Hyung;Kim, Taewan;Kim, Seung Re;Chu, Yurim;Kim, Hyun Sik
    • Journal of Industrial Technology
    • /
    • v.38 no.1
    • /
    • pp.21-27
    • /
    • 2018
  • In January 2018, the Ministry of Education published "Seismic design criteria for school buildings" and "Manual for seismic performance evaluation and retrofit of school buildings" to evaluate seismic performances through linear analysis. This paper evaluates the seismic performance of an old school building through the linear analysis. The target building was constructed in the late 1970s, and the seismic-force-resisting system was assumed to be a reinforced concrete moment frame with an un-reinforced masonry wall. As a result of the evaluation, the target building does not satisfy the 'life safety' level of 1.2 times the design spectrum. The average strength ratio of moment frames, an indicator of the level of seismic performance tends to be controlled by beams. However, through the Pohang earthquake, it was known that the short column effect caused by the partially infilled masonry wall caused shear failure of the columns in school buildings. Therefore, it is necessary to improve the linear analysis so that the column controls the average strength ratio of moment frames.

A Study on the Applicability of Decision Support System for the Permission of Forest Land-Use Conversion (산지전용허가 의사결정지원시스템의 실제 운용가능성에 관한 연구)

  • Choi, Sang Hyun;Kim, Eun Jin;Nam, Joo Hee;Woo, Jong Choon
    • Journal of Forest and Environmental Science
    • /
    • v.30 no.1
    • /
    • pp.45-49
    • /
    • 2014
  • This study was tried to find out the applicability of decision support system for forest land use conversion, which developed based on algorithm for forest land-use conversion. Decision support system developed by Ministry of Safety Administration is free from the existing licensed laws omission. And it made the input requirements for each value of the final result so that you can determine whether the permit was available by the laws and regulations related to the algorithm for forest land use conversion. Also, in order to do field surveys, equal sampling interval method is used to extract samples for the operability by comparing and analyzing the actual area. As a result, 88 areas of total 100 areas are able to get permission by the decision support system for forest land use conversion, and it means if there is enough data with sufficient research, it can make the availability permits easily.

A Study on Electric Safety Control Device for Prevention of Over Current and Short Circuit Faults (과전류 및 단락사고 방지용 전기안전 제어장치에 관한 연구)

  • Jo, Si-Hwan;Kwak, Dong-Kurl;Jung, Do-Young;Shim, Jae-Sun;Kim, Jung-Sook
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2100-2101
    • /
    • 2008
  • This paper is studied on a protective control system for electrical fire and electrical faults due to over current or electric short circuit faults by using electrical thermal characteristics of PTC (Positive Temperature Coefficient) thermistor and current response characteristics of high sensitive reed switch. The PTC thermistor has characteristic of positive resistivity temperature coefficient according to the temperature variation, which is construction of a regular square and cube demarcation with BaTiO3_Ceramics of positive temperature coefficient. Also PTC thermistor shows the phenomenon which is rapidly increased in the resistivity if the temperature is increased over Curie temperature point, and reed switch, which is used for electrical fault current sensing devices, have a excellent characteristic of response velocity in degree of ${\mu}s{\sim}ms$ that sensing magnetic flux in proportion to dimension of line current. This paper is proposed on a protective control system use PTC thermistor and reed switch for sensor which is protected from electrical fire due to overload faults or electric short circuit faults. Some experimental results of the proposed electric safety control device are confirmed to the validity of the analytical results.

  • PDF