• Title/Summary/Keyword: KV

Search Result 576, Processing Time 0.027 seconds

Estimation of the proper capacity of Dispersed Storage and Generation system for uninterruptable service in one bank outage case in 154/22.9KV S/S (154/22.9 KV S/S의 1 BANK 사고시 무정전 전력공급을 위한 분산형 전원의 적정용량 산정 검토)

  • Kim, Jae-Eon;Rho, Dae-Suk;Kim, Ho-Yong
    • Proceedings of the KIEE Conference
    • /
    • 1989.11a
    • /
    • pp.216-219
    • /
    • 1989
  • Over the last decade or so, there has been an increase in activity devoted to the development of renewable resources for generating electric energy. Many of these generators are small and can only be economically connected to the distribution system or to ths subtransmission system. Those which involve storage, a secondary source of energy, can provide a means to achieve more efficient use of existing generating plant. Such systems are known collectively as Dispersed Storage and Generation devices, or DSGs. So, in this paper, for uninterruptable service in one bank outage in 154/22.9KV substation, the proper capacity of DSGs is examined through the configuration and the reliability.

  • PDF

Development of Optical CT and PT using BSO Single Crystal (BSO를 이용한 광CT, PT 개발)

  • Shin, K.H.;Lee, B.K.;Cho, H.K.;Kim, Y.H.;Kim, Y.S.;Park, H.S.
    • Proceedings of the KIEE Conference
    • /
    • 1992.07a
    • /
    • pp.491-494
    • /
    • 1992
  • This paper described the development example of optical CT(Current Transformer) and optical PT (Potential Transformer) which is measurement system of current and voltage of electric power line using Electro-Optic effect and Magneto-Optic effect. We designed the optical CT of 22KV class and 154KV class and an optical PT of 22KV class. And now the filed testing is in progress in a KEPCO's substation.

  • PDF

가공 송전용 신전선의 개발동향

  • 이수홍;한광현;김신철
    • 전기의세계
    • /
    • v.45 no.1
    • /
    • pp.10-15
    • /
    • 1996
  • 가공송전망 고전압화는 세계적으로는 1,000KV까지 검토되고 있으며 우리나라에서도 765KV를 시험 운전추진중에 있다. 송전선의 전류용량 증대방법으로서는 도체크기의 대형화, 다도체화 뿐만 아니라 경 알루미늄을 도체로 사용한 종래의 ACSR을 대체할 수 있는, 초내열 알루미늄선을 사용하여 허용전류를 증가시킨 STACIR의 채택이 확대되고 있다. 증용양화 송전선의 본격적 도입과 함께 송전선로 운영시에 발생하는 공해성, 환경저해성을 촤소화시키는 환경조화선로및 지역별 특성에 맞는 특수기능 전선에도 그 관심이 고조되고 있는바 도체재료와 구조에 대한 꾸준한 기술 개발로 송전선의 고신뢰화, 다기능화가 지속적으로 진행되고 있다. 우리나라의 경우도 1960년대에 ACRS이 가설된 이후 늘어나는 전력수요에 부응하기 위하여 1995년 STACIR의 154KV 의정부-동두천 송전선로 구간에 가설운전을 시작으로 신송전로의 시대에 진입했다고 볼 수 있다.

  • PDF

A study on radio interference voltage(RIV) reduction of 22-9 KV-y distribution line (22.9 KV-y 배전선로 통신 유도장해전압(RIV)감소 대책에 관한 연구)

  • Chon, Y.K.;Sun, J.H.;Cho, K.H.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1670-1674
    • /
    • 1998
  • Now and then there are many electrical accidents between cable and line post insulator which is degraded by long time using, causing leakage current on the surface of insulator. In this paper it is denied that the 22.9 KV-y distribution lines are protected by binding cover which is needed from fog or rainy moisture, surges occurring by swiching or lightening pulse. It is analyzed to investgate the unballanced transfer characteristics and reflection coefficient by using bidding cover and non-cover. It was tested the radio interference voltage in the test room. In the factory it was tested the amount of leakage current causing on the surface of insulator in the state of no load and 70(%) load.

  • PDF

A INSULATING DESIGN OF $SF_6$ GAS SEALING END OF CONDENSER CONE TYPE USED FOR 345KV OF CABLE (콘덴서 콘 방식의 345KV OF 케이블용 $SF_6$ 가스중 종단접속함의 절연 설계)

  • Kim, H.J.;Lee, S.C.;Oh, O.J.;Lee, H.S.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1553-1555
    • /
    • 1994
  • In this paper, we describes the research in condenser cone of $SF_6$ gas sealing end for 345KV oil-filled cable. The designed of condenser cone based on the results electric field analysis by electrostatics theory ana FEM. As a results. we have been designed the condenser cone and the inner insulation part of $SF_6$ seating end, the width and length, the number of condenser, the length of stress relief slope, the total length of condenser cone.

  • PDF

Characteristic of Magnetic Fields Distribution in 345/154KV outdoor Substation (345/154KV 전력소 구내의 자계 분포 특성)

  • Sa, J.W.;Kim, S.M.;Hong, J.P.;Jeon, H.T.;Hahn, S.C.;Joo, S.W.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07a
    • /
    • pp.97-99
    • /
    • 1997
  • For two decades and more, a lot of research work on the biological effects of EMF (Electromagnetic Field) on human health have been reported. Electric facilities in a typical substation are the main source of magnetic field. This paper presents the measurement and analysis of magnetic field in 345/154KV outdoor substation. The magnetic field depends on the currents which distributed by electric facilities. The result of this paper will be able to be used as basic informations to reduce the level of EMF from the electric utility facilities.

  • PDF

Analysis of transient stability of 154KV power systems in Korea by digital computer techniques (디지탈 계산기에 의한 우리나라 154KV계통의 과도안정도 해석)

  • Man-Choon Han;Sang-Hee Park;Young-Chan Kim
    • 전기의세계
    • /
    • v.17 no.4
    • /
    • pp.18-27
    • /
    • 1968
  • Analysis of the transient stability of power systems following disturbances involves many sets of non-linear differential equations. This paper attempts to analyze the transient stability of multi-machine power systems by the step by step method, using the electronic digital computer. The critical switching times and phase angles for the main 154KV transmission system in Korea, are given from the swing curves of the probable conditions. It is concluded that the system is, in general, stable if the relay is cut off within 12 cycles after the fault. However the fault of DAEGU-SANGJU branch, accompanying much real power, makes the system unstable when the raly is cut off within 4 cycles after fault or automatic voltage regulators are equipped in this branch.

  • PDF

Analysis of Power System Dynamic Security Due to Operation of 345kv CLR (345kv한류리액터 운전에 따른 전력계통 동적안전도 해석)

  • Lee Baek Seok;Kang Dae Eon;Lee Kang Wan
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.24-26
    • /
    • 2004
  • The growing demand for electricity has result in a corresponding increase in power generated and transmitted. As the increase in installed capacity of power system, the fault currents of 345kv system will be increased beyond the interrupting duty of the circuit breakers. The current limiting reactors are used to limit the fault current. The paper presents the result of the transient stability and voltage stability due to install 345kV current limiting reactor to suppress the fault currents.

  • PDF

Cardiomyogenic Potential of Human Adipose Tissue and Umbilical Cord Derived-Mesenchymal Like Stem Cells (사람의 지방 및 제대에서 유래된 유사중간엽 줄기세포로부터 심근세포로의 분화 유도)

  • Park, Se-Ah;Kang, Hyeon-Mi;Kim, Eun-Su;Kim, Jin-Young;Kim, Hae-Kwon
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.34 no.4
    • /
    • pp.239-252
    • /
    • 2007
  • Objectives: In the present study, we examined the differentiation potential of human adipose-(HAD) and human umbilical cord-derived mesenchymal like stem cells (HUC) into cardiomyocytes. Methods: Cells were initially exposed to 5-azacytidine for 24h cells and then were cultivated in the presence or absence of activin A, TGF-$\beta$1, or Wnt inhibitor with various combinations of BMP and FGF. Assessment of cardiomyogenic differentiation was made upon the expression of cardiomyocyte-specific genes using RT-PCR. Results: HAD that cultivated in control medium for 4 weeks after 5-azacytidine expose showed new expression of TnT gene and increased expression of Cmlc1 and kv4.3 genes. However, HAD cultivated in the presence of combinations of BMP-4/FGF-4 (B4/F4) and BMP-4/FGF-8 (B4/F8) showed new expression of $\beta$-MHC gene and more increased expression of Cmlc1, TnT, TnI, Kv4.3 genes. Significantly enhanced expression of Cmlc1, TnT, and Kv4.3 genes were also observed compared to that cultivated in the control medium. Treatment of HUC with either 5-azacytidine or combinations of BMP and FGF did not affect the expression profile of these genes. However, when activin A or TGF-$\beta$1 was present in addition to the BMP-2/FGF-8 (B2/F8) after 5-azacytidine exposure, HUC exhibited new expression of $\beta$-MHC gene and increased expression of $\alpha$-CA, TnT and Kv4.3 genes. When Wnt inhibitor was present in addition to BMP and FGF, HUC showed new expression of Cmlc1 gene and increased expression of $\alpha$-CA, TnT, TnI and Kv4.3 genes. Conclusions: Based on these observations, it is suggested that HAD and HUC could differentiate into cardiomyocytes which might be used as therapeutic cells for the heart diseases.

A Study on the Development of a 1800KV Testing Chamber for Gas Insulation (가스 절연 시험용 체임버 개발 연구)

  • Cho, Yun-Ok;Choi, Byoung-Joo;Kim, Kwang-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1989.07a
    • /
    • pp.405-408
    • /
    • 1989
  • A 1800KV testing chamber for gas insulation has been developed. To develop the chamber, all parts consisting of the chamber, namely, bushing, main chamber, shield, conductor bus, inspection window, feedthrough, and spacer have been designed based on numerical electric field analysis. This paper presents the detailed design philosophy and methods of the chamber.