• Title/Summary/Keyword: KS examination

Search Result 34, Processing Time 0.028 seconds

Measures and Cause Analysis of Electrical Disturbance for Elevator Equipment of the Apartment House (공동주택 승강기 설비의 전기적 장해 원인 분석 및 대책에 관한 연구)

  • Kim, Gi-Hyun;Bae, Suk-Myong;Park, Chee-Hyun;Choi, Myeong-Il
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.3
    • /
    • pp.88-95
    • /
    • 2007
  • Domestic elevator accidents which are related to human life such as death are occurring steadily. This research measured and analyzed for the quality of power source which has possibility to be associated with fault and malfunction of elevator equipment although it is not direct cause examination. In conclusion, we acquired the result that there is possibility that the quality of power source(Sag, Interruption, Harmonic, Electromagnetism emission waveform, Static electricity etc) has an effect on movement of elevator through examination of three elevator facility models and suggested measures for it. Accordingly, this research result will be used as data to suggest establishment of elevator examination regulations and KS regulations for domestic elevator industry and the least safety of household using elevator.

A study on the improvable decision of saturated surface dry of fine aggregate (잔골재 표건상태 판정방법 개선에 관한 연구)

  • Song Ji-Heup;Cho Hyun-Dae;Choi Hyun-Soo;Jun Myoung-Hoon;Lee Do-Heun;Jaung Jae-Dong
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05b
    • /
    • pp.153-156
    • /
    • 2005
  • Surface dry condition examination method on the KS F 2504(Testing method for specific gravity and absorption of fine aggregate) has dim detail prescriptions which can cause different ways of understanding based on one's convinence, not on correct means of rule. So we investigate the problems about the inconsistency on decisioing surface dry condition at management examination in the lab and scene. In conclusion, free-falling method is easier and faster than self-weight method. And we also found that the most important face on decisioning surface dry is compacting factor of tamping rod.

  • PDF

The Status of Clay Minerals in Aggregates and Their Effect on the Concrete Performance (골재에 포함된 토분의 현황 조사 및 콘크리트의 성능에 미치는 영향)

  • Kim, In;Han, Min-Cheol
    • Journal of the Korea Institute of Building Construction
    • /
    • v.24 no.4
    • /
    • pp.393-402
    • /
    • 2024
  • The Korean Industrial Standard(KS) KS F 2527("Aggregates for Concrete") does not explicitly define criteria for clay mineral content in aggregates. This lack of clear quality standards and testing methodologies is further compounded by a scarcity of relevant research within both academic and industrial spheres. Consequently, the construction industry, encompassing both aggregate production and utilization, often overlooks the management of clay mineral content due to its perceived economic implications. This study addresses this gap by investigating the current state of regulations concerning clay mineral content in aggregates, exploring the causes of its occurrence, and evaluating its impact on concrete performance. The chemical composition of the clay minerals was determined to primarily consist of Al2O3, Fe2O3, and SiO2, which are commonly found in clay. X-ray diffraction(XRD) analysis revealed that the predominant clay minerals were montmorillonite and illite, both known for their high absorption capacity. An examination of domestic and international standards for clay mineral content in aggregates demonstrated that the density and absorption rate specifications outlined in KS F 2527("Aggregates for Concrete") only offer indirect estimations of clay mineral levels. Furthermore, the investigation into the influence of clay mineral content on concrete performance suggests that a higher clay mineral content necessitates a corresponding increase in the unit quantity of aggregates to maintain adequate workability. This, however, has a detrimental effect on the compressive strength of the concrete.

Mechanical Properties of Dissimilar Friction Welded Steel Bars in Relation to Post Weld Heat Treatment (이종 마찰용접 강봉재의 후열처리에 따른 기계적 특성)

  • Kong Yu-Sik;Kim Seon-Jin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.4 s.247
    • /
    • pp.402-408
    • /
    • 2006
  • Dissimilar friction welding were produced using 15(mm) diameter solid bar in chrome molybedenum steel(KS SCM440) to carbon steel(KS S45C) to investigate their mechanical properties. The main friction welding parameters were selected to endure good quality welds on the basis of visual examination, tensile tests, Vickers hardness surveys of the bond of area and H.A.Z and microstructure investigations. The specimens were tested as-welded and post-weld heat treated(PWHT). The tensile strength of the friction welded steel bars was increased up to 100% of the S45C base metal under the condition of all heating time. Optimal welding conditions were n=2,000(rpm), $P_1=60(MPa),\;P_2=100(MPa),\;t_1=4(s),\;t_2=5(s)$ when the total upset length is 5.4 and 5.7(mm), respectively. The peak of hardness distribution of the friction welded joints can be eliminated by PWHT. Two different kinds of materials are strongly mixed to show a well-combined structure of macro-particles without any molten material and particle growth or any defects.

Optimization of Friction Welding for Motor Vehicle Safety Belts: Part 1-Mechanical Properties and Microstructure (수송차량 안전벨트용 모터축재의 마찰용접 최적화(1) - 기계적 특성 및 조직)

  • Kong, Yu-Sik;Ahn, Seok-Hwn
    • Journal of Ocean Engineering and Technology
    • /
    • v.26 no.1
    • /
    • pp.64-69
    • /
    • 2012
  • Dissimilar friction welds were produced using 15-mm diameter solid bars of chrome molybdenum steel (KS SCM440) and carbon steel (KS SM20C) to investigate their mechanical properties. The main friction welding parameters were selected to ensure good quality welds on the basis of visual examination, tensile tests, Vickers hardness surveys of the bond area and HAZ, and macro-structure investigations. The specimens were tested as-welded and post-weld heat treated (PWHT). The tensile strength of the friction welded steel bars was increased to 100% of the SM20C base metal under the condition of a heating time of more than four seconds. Optimal welding conditions were n = 2,000 (rpm), HP = 60 (MPa), UP = 100 (MPa), HT = 5 (s),and UT = 5 (s), when the total upset length was 7.8 (mm). The hardness distribution peak of the friction welded joints could be eliminated using PWHT. The two different kinds of materials were strongly mixed to show a well-combined structure of macro-particles, with no molten material, particle growth, or defects.

Phylogenetic Positioning of a Strongyloides stercoralis Isolate Recovered from a Korean Patient and Comparison with Other Asian Isolates

  • Bae, Jaeho;Jeong, Mi Jin;Shin, Dong hoon;Kim, Hyun Woo;Ahn, Sung Ho;Choi, Jun Ho;Yu, Hak Sun
    • Parasites, Hosts and Diseases
    • /
    • v.58 no.6
    • /
    • pp.689-694
    • /
    • 2020
  • Strongyloidiasis is caused by Strongyloides stercoralis and is one of the most neglected tropical diseases in tropical and subtropical regions. Although several strongyloidiasis cases have been reported in Korea, genetic analysis of Korean isolates is still incomplete. In this study, a parasite was isolated from a 61-year-old man diagnosed with strongyloidiasis during the treatment of lymphoma on his retroperitoneal lymph node. Diffuse symmetric wall thickening from the ascending to descending colon and a nematode-infected intestine was observed following microscopic examination. Genomic DNA was isolated from a patient tissue block, and S. stercoralis was identified by PCR and sequencing (18S rDNA). In order to determine phylogenetic location of a Korean isolate (named KS1), we analyzed cox1 gene (500-bp) and compared it with that from 47 previous S. stercoralis isolates (28 human isolates and 19 canid isolates) from Asian countries. Our results showed that phylogenetic tree could clearly be divided into 5 different groups according to hosts and regions. KS1 was most closely related with the Chinese isolates in terms of genetic distance.

Development of the Testing Method for Impurity Content in Recycled Aggregate for Concrete Structure (구조체 콘크리트용 순화골재의 이물질 함유량 시험방법 개발)

  • Lee, Do-Heun;Jun, Myoung-Hoon;Jaung, Jae-Dong
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.1 no.1
    • /
    • pp.72-80
    • /
    • 2005
  • A recycled aggregate contains impurities that affect negative effects on physical properties of concrete. Therefore, a test method for examining impurities content in recycled aggregate is necessary before use of recycled aggregate. In this study, the test method by visual examination for separating impurities in recycled fine and coarse aggregates was developed. The results of the test are as follow: 1. The current KS F 2576 was necessary for comprehensive revision including types of tested recycled aggregate, definition of terminology, quantity of sample, and test method. 2. Visual examination is appropriate for larger than impurity panicle size of 1.2mm, and the larger panicle size the shorter time was required. 3. For the impurity content test by visual examination, the easiness and accuracy of the test can be obtained from the condition of sample weight of 30 grams with particle size of 2.5mm to 5mm for recycled fine aggregate and the condition of sample weight of 1 kilogram with panicle size of larger than 5mm for recycled coarse aggregate.

  • PDF

A Study on the Properties and Friendly Environment Efficiency Charcoal Concrete Bricks (숯 첨가 콘크리트벽돌의 물성특성과 친환경 성능에 관한 연구)

  • Kim Young-Min;Choi Hee-Yong;Chung Yu-Gun;Ryu Hyun-Gi
    • Journal of the Korea Institute of Building Construction
    • /
    • v.6 no.1 s.19
    • /
    • pp.123-130
    • /
    • 2006
  • After the new house symptoms recently, room environment pollution problem of building syndrome and so on is becoming research about ways to solve this being risen. Is taking advantage of nature data by building materials by one of this way, but Friendly Environmental performance examination for structure material is insufficient misgovernment being real condition that put emphasis in ability as most embellishment and in finish. Environmental examination is insufficient misgovernment on factor itself as structure material. Also, being real condition that radon that is responsible for lung cancer occurrence next to smoke in building materials such as concrete and so on is happened, the danger is reported much through mass communications and research paper etc. Therefore, this research measured radon release amount and the carbon dioxide adsorption rate for physical special quality measuring and Friendly Environment Efficiency that follow to 'KS F 4004 Concrete bricks' regulation after manufacture Concrete Bricks utilizing charcoal that is nature material by sand. This study finding carbon dioxide density appeared and displayed effect that charcoal Controls radon release that happen in Concrete Bricks to maximum 74% that decrease to best 95% though decreased the charcoal addition rate increases.

A study on design and performance test of fire door with high endurance performance in submarine tunnel (고내구성능을 갖는 해저터널 방화문 설계방안 및 성능시험 연구)

  • Park, Sang-Heon;Hwang, Ju-Hwan;Choi, Young-Hwan;An, Sung-Joo;Yoo, Yong-Ho
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.2
    • /
    • pp.331-346
    • /
    • 2018
  • In the tunnel of domestic high - speed railway, the main fire - fighting facility, fire - extinguishing passageway, is installed. However, due to the high pressure of the high - speed train, frequent breakage and maintenance are caused by strong shock and long - term vibration. In order to solve these problems, it is necessary to improve the fire door, but in Korea, it is installed by submitting a certificate by simple KS F 2296 performance test. At present, it is developed as a simple test certification by producing a real scale fireproof door without the theoretical examination in advance, so that a high cost for improvement is occurring in Korea. Therefore, through this study, structural analysis study which can preliminary structure review was carried out in order to design the refuge connection passage fire door and to improve the performance improvement. In order to secure the reliability of the result value, the official authentication test (KS F 2296) were compared.

Failure Analysis of Welded Pipe in Water Supplies for Apartment

  • Lee, Jong Kwon;Hong, Kyung Tae;Hwang, Woon Seok;Koh, Yong Tae;Park, Yong Soo
    • Corrosion Science and Technology
    • /
    • v.3 no.2
    • /
    • pp.67-71
    • /
    • 2004
  • Galvanized Steel pipes have been widely used in industries and apartments, Unexpected early leakage has been found in an apartment. Tunneling corrosion or penetration was found in the water supply pipes. The chemical compositions of the pipes and properties of coating layer were evaluated. The pipes met the specification of KS D 3507. The cause of early failure was analyzed through the examination of macrostructures and microstructures, It was found that the pipes were failed by grooving corrosion, which resulted from galvanic corrosion of weld bead and matrix.