• Title/Summary/Keyword: KS examination

Search Result 34, Processing Time 0.021 seconds

Study on Comparison of Korean Industrial Standard and ASME BPV Code for Radiographic Examination (방사선투과시험(放射線透過試驗)에 있어서 KS와 ASME Code의 비교(比較)에 관(關)한 연구(硏究))

  • Kim, Jin-Koo;Park, Byung-Chul
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.4 no.2
    • /
    • pp.20-29
    • /
    • 1985
  • There are two basic concepts in industrial radiographic examination; one is a radio-graphic sensitivity, and the other is a acceptance criteria. The comparison of these main points are studied for KS Standard and ASME Boiler and Pressure Vessel Code. From the results of the experiment, higher radiographic sensitivity is required in KS Standard when the thickness of material to be examined is less than 20mm in single wall technique. The acceptance criteria for linear type indications are described on same concept in two standards, whereas the acceptance criteria for rounded indications of KS Standard which mainly depends upon the object thickness are more severe than those of ASME BPV Code.

  • PDF

A Study on SPC-related KS and KS A ISO 2859-3 (SPC관련 KS의 제개폐 및 KS A ISO 2859-3에 대한 고찰)

  • Lim Jae-Geun;Cho Byung-Sun;Jung Soo-Il
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.28 no.2
    • /
    • pp.75-80
    • /
    • 2005
  • As a result of globalization process and TBT agreement, KS is also being revised, reestablished and some are abolished according to international standards such as ISO, IEC, etc. Conventional KS sampling inspection standards contained many different procedures from ISO, but recently, to match with international standards, all the rest of the standards except KS A 3102, 3104, 3151 were abolished, and the even the ones being in use still are also scheduled and be revised. Especially, KS A 3101, KS A 3105, KS A 3109, which were used most frequently in Korea were abolished, and the KS A ISO $2859-0\~3$ which coincide with ISO standards were established 3 years ago, but the implementation rate is very slow. Starting next year the national examination for qualification process for the product quality related item will the started and the preparation is underway. This study will investigate the recent sampling inspection process of KS as well as SPC related KS overhaul problem and present the data to help workers in SPC related field. One of the main example will be on KS A ISO 2859-3 and will attempt to help those medium and small sized companies with examples.

Method of Radiographic Examination for Welded Joints in Steel(KS B 0845) - Explanation (강 용접이음의 방사선투과시험 방법(KS B 0845) 해설)

  • Chung, Ku-Pom
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.18 no.3
    • /
    • pp.223-240
    • /
    • 1998
  • 본 고는 1997년 12월 31일 개정된 "강 용접부의 방사선투과시험 방법 및 투과 사진의 등급분류 방법" (한국산업규격 KS B 0845)을 이해하는데 참고가 될 수 있도록 일본공업규격 JIS Z 3104의 해설부분을 번역한 것으로 KS B 0845의 모체가 되는 JIS Z 3104의 본래취지를 정확히 전달하기 위하여 편집하거나 가감하지 않고 원문 그대로 기술하였으며 KS B 0845와는 일부 용어나 항목구성에 차이가 있으나 번호에 관계없이 각항목의 제목을 보고 이해하게 하였다. 특히 일부 부속 규격의 미 제정상태에서 개정판이 발표되어 적용에 혼란을 초래할 수도 있겠으나 부분적인 적용은 가능할 것으로 판단된다.

  • PDF

Ashpalt 2 Component Adhesive Leakage Repair Sealant Evaluation (아스팔트 2액형 점착재의 누수보수 평가에 관한 연구)

  • Cho, Il-Kyu;Kim, Keun-Hur;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.140-141
    • /
    • 2017
  • This study is based on the evaluation of a single component injection type adhesive repair material and a new 2 component type used in leakage of underground concrete structures. The studies showed that based on different mix ratio of the 2 component type adhesive sealant comprised of an asphalt main and latex mixture agent the viscosity of the material compound differed significantly. Based on a permeability testing, injection and economic efficiency, and performance, the appropriate ratio was determined to be 6:1 and was proceeded to the KS F 4935 evaluation method. The 2 component type adhesive sealant uses a static mixer and a cartridge type container for the injection procedure and was able to satisfy the evaluation criteria outlined in the KS F 4935 standard.

  • PDF

Study of Misused Expressions in KS Related to Personal Protective Equipment (안전·위생보호구관련 KS의 오류 및 부정확한 표현사례 연구)

  • Rhee, Biung Hun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.6 no.2
    • /
    • pp.222-248
    • /
    • 1996
  • This study was designed to survey misused expression in 37 KS (Korean Industrial standards) related to personal protective equipment. The results were as follows: 1. One hundred and twenty five misused expressions were found - 44 expressions were used illogically (35.2 %). 80 expressions were wrongly described (64.0 %) The types of illogically misused are: 10 illogical cases, 4 cases of a wrongly designated provision when cited, 12 cases of the lack of provisons for KS, 7 cases of a inappropriate uses of units, 8 cases of an overlapped sizes between standards. - The types of expressions wrongly described are: 30 cases of confusion in using an terms, 4 case of making an error when proofreading, and 29 cases of choosing words not appropriate to describe technical standard, 18 cases of unclear provisons due to missing phrases and terms, and 11 cases of provisons described differently from original intended purposes. 2. There is one case, where the same standard is categorized as two different names. There are three major causes of the misused expressions as seen from the following summary: - Imitated the developed countries' standards without filtering them by considering domestic law and ocher KS standards. - Tended to create each definition for each standard instead use of the basic standard. - Insufficiency of synthetic examination to the correlation between standards.

  • PDF

2 Component Adhesive Leakage Repair Sealant Evaluation (2액형 점착 실링재의 누수보수재 평가에 관한 연구)

  • Cho, Il-Kyu;Kim, Keun-Hur;Oh, Sang-Keun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.4 no.4
    • /
    • pp.396-403
    • /
    • 2016
  • This study is based on the evaluation of a single component injection type adhesive repair material and a new 2 component type used in leakage of underground concrete structures. The studies showed that based on different mix ratio of the 2 component type adhesive sealant comprised of an asphalt main and latex mixture agent the viscosity of the material compound differed significantly. Based on a permeability testing, injection and economic efficiency, and performance, the appropriate ratio was determined to be 6:1 and was proceeded to the KS F 4935 evaluation method. The 2 component type adhesive sealant uses a static mixer and a cartridge type container for the injection procedure and was able to satisfy the evaluation criteria outlined in the KS F 4935 standard.

Relative Dynamic Modulus of Elasticity Comparison of the Eco-friendly Lightweight Concreate According to the Experimental Method (시험방법에 따른 친환경 경량콘크리트의 상대동탄성 계수 비교)

  • Lee, Soo-Hyung;Lee, Han-Baek
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.05a
    • /
    • pp.181-182
    • /
    • 2016
  • We developed eco-friendly lightweight concrete in order to apply eco-friendly lightweight concrete into structural wall or slab of shallow depth urban railway system. However, since lightweight aggregate has different structural feature of porous and it has been overvalued at current KS standard when applied, we did compare the characteristics of freezing and thawing of normal weight aggregate concrete by comparative test method(KS, ASTM). According to test method, there was a big difference of dynamic elastic modulus in lightweight concrete rather than in normal weight aggregate concrete. The big absorption factor in lightweight aggregate is main reason for that. For more detail, in KS law in which only 14 days water curing is carried out, the big amount of moisture in lightweight aggregate is frozen and high heaving pressure occurs and finally that lead to destruction of lightweight concrete. Therefore, it is considered that in case of lightweight concrete, resistibility against freezing and thawing has been undervalued in domestic KS law compared to ASTM law, which is overseas standard. So, a variety of examination about testing criteria and rule would be necessary for exact assessment of lightweight concrete.

  • PDF

Keratanase II Digestion Accompanied with a Liquid Chromatography/Tandem Mass Spectrometry for Urinary Keratan Sulfate Quantitative Analysis

  • Chuang, Chih-Kuang;Lin, Hsiang-Yu;Wang, Tuen-Jen;Huang, Sung-Fa;Lin, Shuan-Pei
    • Journal of mucopolysaccharidosis and rare diseases
    • /
    • v.3 no.1
    • /
    • pp.20-27
    • /
    • 2017
  • Purpose: Mucopolysaccharidosis IV (MPS IV) is a disease characterized by deficient activity of N-acetylgalactosamine-6-sulfatase (GALNS) causing excessive lysosomal storage of keratan sulfate (KS). The identification of the relevant disaccharide units of KS after keratanase II digestion followed by liquid chromatography/tandem mass spectrometry detection (LC-MS/MS) is validated and applicable for the preliminary diagnosis of MPS IV. Methods: A total of 67 urine samples were collected and analyzed from 11 MPS IV patients comprising 10 MPS IVA and one MPS IVB patients, and 56 normal controls. Urinary glycosaminoglycan was first precipitated by the Alcian blue method followed by a digestion of keratanase II. The protonated species of the digested disaccharide products were detected by using multiple reaction monitoring experiment. Results: One particular disaccharide of KS was selected. The transition mass-to-charge (m/z) of the parent ion and its daughter ion after collision was $462.0{\rightarrow}97.0$, whereas the chondrosine used as an internal standard in this assay was m/z $353.9{\rightarrow}73.0$. The results corresponded well with the two-dimensional electrophoresis method. The quantities of urinary KS were significantly raised in confirmed MPS IV patients when comparing with those of normal controls ($170.2{\pm}81.1$ vs. $4.06{\pm}1.92{\mu}g/mL$). Conclusion: The LC-MS/MS method for MPS IVA determination is specific, sensitive, validated, and applicable for urinary KS quantification. This method can be used not only as a first-line biochemistry examination of MPS IVA, but also as an outcome survey after enzyme replacement therapy.

A Present Views and Improvement policy of the Certification System in Korea (우리나라 인증제도의 현황과 개선방안)

  • 조남호;우태희;한우철
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.22 no.51
    • /
    • pp.211-220
    • /
    • 1999
  • The purpose of this study is the necessity of collaboration, equilibrium or the differences of examination items about certification system which is focused on products, such as KS, formal approval, and ISO 9000 family, QS 9000, etc, for Quality management system. We make expert group control this problem. Also we make examination items to be united. And the differences of certification body and personnel necessary is dissolved by proper instruction. Examination process and corrective maintenance should be improved by clarity, fairness and reliability. Problems through preparation for certification and certified company should be focused on reform of consciousness of top management and continuous instruction. And desirable solution for mutual certification problem and others should be found by information interchange system of international cooperation.

  • PDF

Ultrasonic Test Criterion for the Explosively Welded Fe-Naval Brass Bonding Quality (초음파법에 의한 폭발접합 이종금속 접합품질 판정레벨 설정에 관한 연구)

  • 장영권;백영남
    • Journal of Welding and Joining
    • /
    • v.19 no.1
    • /
    • pp.40-48
    • /
    • 2001
  • An ultrasonic test method, as a nondestructive test is applied to ensure the clad interface quality assessment. According to the reference codes and standards, not only korea Industrial Standard(KS) but also American Society for Testing and Materials (ASTM) Standard, ultrasonic examination procedures use the pulse-echo, A-scan, back reflection signal drop method and/or side drilled reference hole used to establish the acceptance criteria of clad material test. But the variety of bonding materials and sizes makes it difficult to produce the reference blocks, or thus the criteria. In order to overcome these practical difficulties, new ultrasonic testing criterion is suggested. In this new method, the theoretical interface reflection signal amplitude level is calculated and suggested as an acceptance criteria with the back reflection signal set to 100% FSH(Full Screen Height) which is based on acoustic impedance mismatch at the clad interface for the explosive clad ultrasonic inspection. Applicability of suggested criterion, for the explosive clad Fe-Naval Brass with different bonding quality is confirmed to the pre-existed KS and ASTM specifications and verified by using SEM (Seanning Electron Microscope) micrograph. The results obtained by the suggested method is more conservative than the results according to the KS B 0234 and ASTM A 578 specifications The suggested method could be applicable to any other combination of explosive clad ultrasonic inspection.

  • PDF