• Title/Summary/Keyword: KEPCO System

Search Result 1,667, Processing Time 0.028 seconds

Reactive Power Loadability in Korean Power System (한전 계통에서의 무효전력 부하 평가에 관한 연구)

  • Yoon, Jong-Su;Won, Jong-Ryul;Yoon, Yong-Beum;Jang, Byung-Hoon;Lee, Ki-Sun;Choo, Jin-Boo
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1472-1474
    • /
    • 1999
  • This paper proposes the estimation method about how much reactive power can be increased or decreased under prescribed bus voltage limits in non-linear reactive power and power flow equations. The static nonlinear reactive power voltage problem can be formulated using a linear resistive(I-V) network with voltage dependent current sources. Linear programming model is derived for finding bounds on reactive power. This method was applied to future Korean power system and proved its effectiveness.

  • PDF

Dynamic Equivalents of the KEPCO System for the Stability Analysis

  • Lee, Hanmin;Kwon, Sae-hyuk;Gilsoo Jang;Lee, Byongjun;Byunghun Chang
    • KIEE International Transactions on Power Engineering
    • /
    • v.12A no.1
    • /
    • pp.20-25
    • /
    • 2002
  • This paper deals with the development of dynamic equivalents of the Korea Electric Corporation (KEPCO) systems. Several coherency identification methods are studied in order to find a proper method to well represent the dynamic characteristics of the KEPCO system. Also, this paper presents the comparison of the detail and classical aggregation methods in terms of the dynamic and static characteristics of the system. The nonlinear time simulation of the developed KEPCO equivalent system and the original system is performed to illustrate the validity of the equivalent system.

A Study on Probabilistic Reliability Evaluation of KEPCO System using TRELSS (TRELSS를 이용한 우리나라 전력계통의 확률론적 신뢰도 평가에 관한 연구)

  • Jeon, Dong-Hoon;Choi, Jae-Seok;Kim, Kern-Joong
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.11
    • /
    • pp.453-462
    • /
    • 2006
  • This paper evaluates the reliability of KEPCO system using TRELSS, which is a probabilistic reliability evaluation program for large-scaled power system. In order to reflect the characteristic of KEPCO system, the sensitivity of reliability indices such as LOLP, EDLC, EENS and Energy Curtailment for variations of TRELSS parameter and input data was analyzed. Additionally, probabilistic reliability of KEPCO system reflecting sensitivity analysis results was systematically evaluated and simulated. Finally, maximum acceptable FOR of KEPCO system to satisfy reliability criterion, which meet in process of establishing the basic plan for long-term electricity supply and demand is suggested.

Large-scale AC/DC EMT Level System Simulations by a Real Time Digital Simulator (RTDS) in KEPRI-KEPCO

  • Park, In Kwon;Lee, Jaegul;Song, Jiyoung;Kim, Yonghak;Kim, Taekyun
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.3 no.1
    • /
    • pp.17-21
    • /
    • 2017
  • Recently, the Korea Enhanced Power system Simulator (KEPS) was upgraded with new processor cards and various peripheral devices. The purpose of the upgrade is for the large-scale AC/DC simulation studies for different purposes such as FACTS, PMU applications, and SPS. The need for such study is now growing in KEPCO network. Frequently, traditional ways of performing the necessary study had been found to be less adequate for guiding the key decisions in the company. Therefore, the growing needs, as well as the revealed inadequacy of the traditional system studies, had been attributing to the momentum for the upgrade project. This paper explains the details of the upgrade project. As an example of presenting the effectiveness of the upgraded RTDS system in KEPRI-KEPCO, a large-scale AC/DC real time simulation case which includes the entire Korean network and a planned MMC-HVDC system is introduced.

Feasibility Study for Application of Frequency Regulation ESS in Cuba: Technological Effects on Improving Frequency Compensation (쿠바 주파수조정 ESS 운영 전략 검토: 주파수 보상 효과 분석)

  • Kim, Soo-Yeol;Lee, Seong-eun;Kim, Jin-tae
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.6 no.2
    • /
    • pp.123-127
    • /
    • 2020
  • KEPCO has installed Frequency Regulation ESS (FR ESS) of 376 MW since 2015. Frequency Regulation is ancillary service to support stabilizing system frequency, which is divided into governor free and automatic generation control. KEPCO operates FR ESS as governor free application and leads FR ESS market with capability of diverse demonstration and operation experiences. To expand FR ESS role during transient states of power system, KEPCO has extended operating time of charging and discharging. KEPCO has also changed speed droop lower than before to improve contribution on frequency compensation, and acquired much experiences of differentiating bad cells from others. Based on these technologies and know-hows, KEPCO Research Institutes received request of feasibility study and technical cooperation for overseas FR ESS business. This paper suggests the simple and practical method for making technological feasibility study of FR ESS.

Development and Test of a Cooling System for a 154 kV Superconducting Fault Current Limiter

  • Kim, Heesun;Han, Young Hee;Yang, Seong-Eun;Yu, Seung-Duck;Park, Byung Jun;Park, Kijun;Yoo, Jaeun;Kim, Hye-Rim;In, Sehwan;Hong, Yong Joo;Yeom, Hankil
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.1 no.1
    • /
    • pp.141-144
    • /
    • 2015
  • The superconducting fault current limiter (SFCL) is an electric power device that limits the fault current immediately in a power grid. Korea Electric Power Corporation (KEPCO) has been developing a 154 kV, 2 kA SFCL since 2011 to protect power grids from increasing fault current and improve the stability and quality of electric power. This SFCL adopts 2G YBCO wires and operates at 71 K and 5 bars. In this paper, a cooling system for the 154 kV SFCL and its cooling test results are reported. This cooling system uses a Stirling-type cooler to make sub-cooled liquid nitrogen ($LN_2$), which cools the superconductor modules of the SFCL. The $LN_2$ is circulated between the cooler and the cryostat that contains superconductor modules. The $LN_2$ also plays the role of a high voltage insulator between the modules and the cryostat, so the pressure was maintained at 5 bars for high insulation performance. After installation in a test site, the cooling characteristics of the system were tested. In this operation test, some important data were measured such as temperature distribution in $LN_2$, pressure change, performance of the heat exchanger, and cooling capacity of the total system. Consequently, the results indicate that the cooling system operates well as designed.

Study on The Underground tunnel Cooling System (전력구 내부온도 예측 및 최적냉각설계에 관한 연구)

  • Kim, Min-ju;Kang, Yeon-woog;Jang, Tae-in;Kang, Ji-won;Kim, Du-jin;Yoon, Jong-keon;Kim, Jae-seung
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.424-425
    • /
    • 2015
  • In the underground cable tunnel, The transmission efficient is lowered due to the local heating region. In this reason, the cooling system is needed. For adapting the cooling system, Preceding study on the factor of increasing temperature in the underground tunnel is essential. In this paper optimal cooling system suggest.

  • PDF

Development of Noise Source Detection System using Array Microphone in Power Plant Equipment (배열형 음향센서를 이용한 발전설비 소음원 탐지시스템 개발)

  • Sohn, Seok-Man;Kim, Dong-Hwan;Lee, Wook-Ryun;Koo, Jae-Raeyang;Hong, Jin-Pyo
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.1 no.1
    • /
    • pp.99-104
    • /
    • 2015
  • In this study, it has been initiated to investigate the specific abnormal vibration signal that has been captured in the power equipment. Array Microphone can be used in order to detect the direction and the position of the noise source. It is possible to track the abnormal mechanical noise in the power plant by utilizing the program and the microphone array system developed from this research. Array microphone system can be operated as a constant monitoring system.

A Case Study on Probabilistic Adequacy Assessment of KEPCO System (우리나라 전력계통의 공급적정도 평가에 관한 사례연구)

  • Jeon, D.H.;Kyak, N.H.;Park, S.H.;Han, K.N.;Choi, J.S.;Kim, K.J.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.61-62
    • /
    • 2007
  • This paper evaluates probabilistic reliability of KEPCO system using TRELSS, which is a probabilistic reliability evaluation program for large-scaled power system. In order to systematically evaluate probabilistic reliability of KEPCO system, contingency cases causing load loss in (N-1) & (N-2) contingency depth was analyzed and reliability indices such as LOLP, EDLC, EENS according to change of FOR was calculated.

  • PDF

Development Study on the Power System Analysis in Myanmar (해외 송변전 사업 추진사례(미얀마 전력망 진단 및 분석))

  • Mun B. S.;Bang M. J.;Choi H. J.;Kim J. H.;Kim S. H.;Choi Y. S.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.51-53
    • /
    • 2004
  • KEPCO is now promoting the overseas transmission businesses on the basis of competitive transmission technology. This paper deals with a development study on the power system network analysis in Myanmar which was performed as the first overseas transmission business of KEPCO. The aim of this study is to establish comprehensive and stable power system network plan by analyzing the current and future system in Myanmar.

  • PDF