• Title/Summary/Keyword: KEPCO Power System

Search Result 1,269, Processing Time 0.028 seconds

Reaction Characteristics of New Oxygen Carrier for 0.5 MWth Chemical Looping Combustion System at High Temperature and High Pressure Conditions (0.5 MWth 케미컬루핑 연소 시스템 적용을 위한 신규 산소전달입자의 고온·고압 반응 특성)

  • KIM, JUNGHWAN;LEE, DOYEON;NAM, HYUNGSEOK;JO, SUNG-HO;HWANG, BYUNG WOOK;BAEK, JEOM-IN;RYU, HO-JUNG
    • Journal of Hydrogen and New Energy
    • /
    • v.29 no.5
    • /
    • pp.473-482
    • /
    • 2018
  • To check applicability of recently developed new oxygen carrier for 0.5 MWth chemical looping combustion system, reactivity tests were carried out at high temperature and high pressure conditions. Pressure, temperature, gas velocity, $CH_4$ flow rate, and solid height were considered as operating variables. The new oxygen carrier (N016-R4) showed not only high fuel conversion but also high $CO_2$ selectivity within all the operating conditions in this study. The reactivity of N016-R4 particle was compared with previous oxygen carriers. The N016-R4 particle represented outstanding reactivity among 10 oxygen carriers in terms of fuel conversion and $CO_2$ selectivity.

Development of the Corrosion Deterioration Inspection Tool for Transmission Tower Members (송전철탑 부재 부식열화 검사장비 개발)

  • Woo, Sang-Kyun;Youn, Byong-Don;Kim, Ki-Jung;Chu, In-Yeop
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.4
    • /
    • pp.77-83
    • /
    • 2016
  • Recently, interests for maintenance of transmission tower are increasing to extend life of structures and reduce maintenance cost. However, existing classical diagnosis method of corrosion deteriorated degree on the transmission tower steel members, visual inspection, has a problem that error often due to difference of inspector's individual knowledge and experience. In order to solve the problem, this study carried out to develop the corrosion deterioration inspection tool for transmission tower steel members. This tool is composed of camera equipment and computer-aided diagnosis system. We standardized the photographing method by camera equipment to obtain suitable pictures for image processing. Diagnosis system was designed to evaluate automatically degree of corrosion deterioration for member of transmission tower on the basis of the RGB color image processing techniques. It is anticipated that developed the corrosion deterioration inspection tool will be very helpful in decision of optimal maintenance time for transmission tower corrosion.

The study on the effect of fracture zone and its orientation on the behavior of shield TBM cable tunnel (단층파쇄대 규모 및 조우 조건에 따른 전력구 쉴드 TBM 터널의 거동 특성 분석)

  • Cho, Won-Sub;Song, Ki-Il;Kim, Kyoung-Yul
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.16 no.4
    • /
    • pp.403-415
    • /
    • 2014
  • Recently, the temperature rise in the summer due to climate change, power usage is increasing rapidly. As a result, power generation facilities have been newly completed and the need for ultra-high-voltage transmission line for power transmission of electricity to the urban area has increased. The mechanized tunnelling method using a shield TBM have an advantage that it can minimize vibrations transmitted to the ground and ground subsidence as compared with the conventional tunnelling method. Despite the popularity of shield TBM for cable tunnel construction, study on the mechanical behavior of cable tunnel driven by shield TBM is insufficient. Thus, in this study, the effect of fractured zone ahead of tunnel face on the mechanical behavior of the shield TBM cable tunnel is investigated. In addition, it is intended to compare the behavior characteristics of the fractured zone with continuous model and applying the interface elements. Tunnelling with shield TBM is simulated using 3D FEM. According to the change of the direction and magnitude of the fractured zone, Sectional forces such as axial force, shear force and bending moment are monitored and vertical displacement at the ground surface is measured. Based on the stability analysis with the results obtained from the numerical analysis, it is possible to predict fractured zone ahead of the shield TBM and ensure the stability of the tunnel structure.

Economic Assessment of the Battery Energy Storage System with Its Customer Type (수용가 형태에 따른 전지전력저장시스템의 경제성 평가)

  • 손학식;최준호;김재철
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.2
    • /
    • pp.81-89
    • /
    • 2002
  • The Battery Energy Storage System (BESS) has lots of advantages such as load leveling, quick response emergency power (spinning reserve), frequency and voltage control, improvement of reliability, and deferred generation and transmission construction. However, it is very critical that economic feasibility requires justification from the customer side of meter to promoting the dissemination of BESS in nation widely. In this paper, we proposed the economic assessment model of customer owned BESS which is complemented and improved the existing model. The proposed model is applied to the typical customer types, i.e. light industrial, commercial, and residential, which are taken from the statistical analysis on the load profile survey of Korea Electric Power COmpany (KEPCO). The economic viability performed for each customer load type to justifying their economic feasibility of BESS installation from the economic measures such as payback period, Net Present Worth (NPW), Rate Of Return (ROR). The results show that the BESS has economic benefits to the specific customer type, i.e. residential customer. Therefore, the government and the energy agency should be committing the support program, such as tax incentive, financial support, to disseminate the BESS nation widely. The results of this paper are useful to the customer investment decision-making and the national energy policy & strategy in Korea.

Assessment of FEED Structure and Functions for Project Management of Thermal Power Plant Construction (사업관리 관점의 FEED 업무 프로세스 구조 및 항목 평가 - 화력발전소를 중심으로 -)

  • Kim, Namjoon;Jung, Youngsoo;Yang, Myungdirk
    • Korean Journal of Construction Engineering and Management
    • /
    • v.16 no.5
    • /
    • pp.65-76
    • /
    • 2015
  • FEED (Front End Engineering and Design) is the key area that determines the competitiveness of procurement and construction in the EPC contracts especially in terms of the added value. Nevertheless, previous researches in FEED have been limited to the process and deliverable of design work or the particular management business function (e.g. System Engineering, collaboration, information etc.). In this context, the purpose of this study is to propose a comprehensive FEED structure and its functions from the project management perspective throughout the whole project life-cycle for thermal power plants. Proposed FEED business procedures are classified into three levels; First level is the classification of FEED business phases, the second level defines major FEED management functions, and the third level is detailed FEED functions. A survey using proposed FEED functions and assessment variable was conducted in order to analyze the current status and the areas for future improvement. It is expected that the proposed structure, functions, and evaluation methodology for FEED management will contribute to effective practice of FEED as well as to improvement of competitive capability for engineering, procurement, and construction (EPC) companies.

Fatigue Damage Analysis of a Low-Pressure Turbine Blade (저압터빈 블레이드의 피로손상 해석)

  • Youn, Hee Chul;Woo, Chang Ki;Hwang, Jai Kon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.7
    • /
    • pp.713-720
    • /
    • 2015
  • The sizes of the final blades of a low-pressure (LP) steam turbine have been getting larger for the development of high-capacity power plants. They are also larger than the other blades in the same system. As a result, fatigue damage is caused by a large centrifugal force and a low natural frequency of the blade. Recently, many failure cases have been reported due to repeated turbine startups and their prolonged use. In this study, the causes and mechanism of failure of a LP turbine blade were analyzed by using a finite element method to calculate the centrifugal force, the natural frequency of a stress-stiffening effect, and the harmonic response. It was observed that the expected fatigue damage position matched the real crack position at the airfoil's leading edge, and an equivalence fatigue limit approached a notch fatigue limit.

A Study on Numerical Analysis of the AC Loss in a Single-layer Superconducting Cable Sample (단층 초전도케이블 샘플에서 교류손실의 수치해석에 대한 연구)

  • Li, Zhu-Yong;Ma, Yong-Hu;Ryu, Kyung-Woo;Hwang, Si-Dole
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.7
    • /
    • pp.606-611
    • /
    • 2009
  • AC loss is one of the important factors for commercialization of a high temperature superconducting (HTS) cable from an economic point of view. But AC loss characteristics of the HTS-cable are not elucidated completely because of its complex structure. As an earlier stage of analyzing the AC loss in the 22.9 kV/50 MVA, 100m HTS-cable system of Korea Electric Power Corporation (KEPCO) which is now in collaboration with us, a two-dimensional (2D) numerical model, which takes into account the nonlinear conductivity properties of a high temperature superconductor, has been developed. In order to examine our 2D model, we have prepared several single-layer cable samples whose AC losses are sufficiently reliable due to their simple structure. The AC losses of the samples were experimentally investigated and then compared with our 2D model. The results show that the numerically calculated AC losses are not in good agreement with the measured ones for the cylindrical cable and deca-cable samples with low critical current density. However, the numerically calculated and measured AC losses are relatively in good agreement for the deca-cable and hex-cable samples with high critical current density, although the difference between these two loss data in the deca-cable sample tends to increase in the low current region.

A Modified EGEAS Model with Avoided Cost and the Optimization of Generation Expansion Plan (회피비용을 고려한 EGEAS 모형 개발과 전원개발계획의 최적화)

  • 이재관;홍성의
    • Korean Management Science Review
    • /
    • v.17 no.1
    • /
    • pp.117-134
    • /
    • 2000
  • Pubilc utility industries including the electric utility industry are facing a new stream of privatization com-petition with the private sector and deregulation. The necewssity to solve now and in the future power supply and demand problems has been increasing through the sophisticated generation expansion plan(GEP) approach con-sidering not only KEPCo's supply-side resources but also outside resources such as non-utility generation(NUG) demand-side management (DSM). Under the environmental situation in the current electric utility industry a new approach is needed to acquire multiple resources competitively. This study presents the development of a modified electric generation expansion analysis system(EGEAS) model with avoided cost based on the existing EGEAS model which is a dynamic program to develope an optimal generation expansion plan for the electric utility. We are trying to find optimal GEP in Korea's case using our modified model and observe the difference for the level of reliabilities such as the reserve margin(RM) loss of load probability(LOLP) and expected unserved energy percent(EUEP) between the existing EGEAS model and our model. In addition we are trying to calculate avoided cost for NUG resources which is a criterion to evaluate herem and test possibility of connection calculation of avoided cost with GEP implementation using our modified model. The results of our case study are as follows. First we were able to find that the generation expansion plan and reliability measures were largely influenced by capacity size and loading status of NUG resources, Second we were able to find that avoided cost which are criteria to evaluate NUG resources could be calculated by using our modified EGEAS model with avoided cost. We also note that avoided costs were calculated by our model in connection with generation expansion plans.

  • PDF

Selection of the Best Oxygen Carrier for Chemical Looping Combustion in a Bubbling Fluidized Bed Reactor (기포유동층에서 케미컬루핑 연소시스템을 위한 최적 산소전달입자 선정)

  • Kim, Hana;Kim, Jung-Hwan;Yoon, Joo-Young;Lee, Doyeon;Baek, Jeom-In;Ryu, Ho-Jung
    • Clean Technology
    • /
    • v.24 no.1
    • /
    • pp.63-69
    • /
    • 2018
  • The reduction reaction characteristics and physicochemical properties were studied for the selection of oxygen carrier, which is the core of the chemical looping combustion (CLC) technology. Fuel conversion and $CO_2$ selectivity of oxygen carrier according to the concentration of reducing gas and the reduction temperature using three kinds of oxygen carrier (SDN70, N018-R2, N016-R4) were measured and compared. In addition, Attrition Index (AI) and BET surface area were measured to analyze the attrition resistance and the surface characteristics of the oxygen carrier. As a result, it was confirmed that all three kinds of oxygen carrier were suitable for use in chemical roofing combustion system, and the best particle was determined to be N016-R4.

Effects of Operating Variables on Separation Rate and Separation Efficiency in Ash Separator for Solid Fuel Chemical Looping Combustor (고체연료 매체순환연소기를 위한 회재분리기에서 분리속도 및 분리효율에 미치는 조업변수들의 영향)

  • RYU, HOJUNG;LEE, DONGHO;YOON, JOOYOUNG;JANG, MYOUNGSOO;BAE, DALHEE;PARK, JAEHYEON;BAEK, JEOMIN
    • Journal of Hydrogen and New Energy
    • /
    • v.27 no.2
    • /
    • pp.211-219
    • /
    • 2016
  • To develop an ash separator for the solid fuel chemical looping combustion system, effects of operating variables such as solid injection nozzle velocity, diameter of solid injection nozzle, gap between solid injection line and vent line, vent line inside diameter, and solid intake height on solid separation rate and solid separation efficiency were measured and discussed using heavy and coarse particle and light and fine particles mixture as bed material in an acrylic fluidized bed apparatus. The solid separation rate increased as the solid injection nozzle velocity and the diameter of solid injection nozzle increased. However, the solid separation rate decreased as the gap between solid injection line and vent line, the vent line inside diameter, and the solid intake height increased. The solid separation efficiency was in inverse proportion to the solid separation rate. In this study, we could get high solid separation rate up to 2.39 kg/hr with 91.6% of solid separation efficiency.