• Title/Summary/Keyword: K5 system

Search Result 31,957, Processing Time 0.057 seconds

Analysis for the Bit Error Probability in the PCM-NRZ/FM Telemetry System (PCM-NRZ/FM Telemetry 시스템에서 Bit 오차확률에 관한 분석)

  • 강정수
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.8 no.2
    • /
    • pp.76-81
    • /
    • 1983
  • PCM-NRZ/FM Telemetry system is constructed on the basis of RF link with FM modulatedand NRZ-L binary coded PCM data are assumed to transmit through 5th-order Bessel filter. Upon demodulated by the limiter-discriminator at the receiver, the probability of bit error, which is important for performance estimation of digital system, is analyzed against SNR. The analysis based on the following parameters, that is bit rate 140kHz, frequency of pre-modulation filter f-100kHz, maximum frequency deviation of transmitter 2f=300kHz, was performed. As a result, when the telemetry system with the parameters above is designed, the probability of bit error is obtained as 10 along with fT=0.7 and h=2, T=2.

  • PDF

Characteristics of Medical Polymer Based on Epoxy Resin System -Cure Characteristics for DGEBA/MDA/PGE- DMU System by Kissinger and Ozawa Equations- (에폭시 수지계 의료용 고분자 재료의 특성 연구 - Kissinger 식과 Ozawa 식에 의한 DGEBA/MDA/PGE-DMU 계의 경화특성 -)

  • Kim, Jang-Hoon;Lee, Jae-Young;Kim, Sang-Wook;Sim, Mi-Ja
    • Korean Journal of Materials Research
    • /
    • v.11 no.9
    • /
    • pp.727-732
    • /
    • 2001
  • The cure kinetics of diglycidyl ether of bisphenol A (DGEBA)/4,4'- methylene dianiline (MDA) system with synthesized phenyl glycidyl ether-dimethylurea (PGE-DMU) was studied by Kissinger and Ozawa equations with DSC analysis in the temperature range of $20~300^{\circ}C$ To investigate the reaction mechanism between epoxy group of PGE and urea group of DMU, FT-lR spectroscopy analysis was used. The epoxide group of PGE reacted with the urea group of DMU and formed a hydroxyl group which acted as a catalyst on the cure reaction of other epoxide and amine groups. The activation energy of DGEBA/MDA system without PGE-DMU was 46.5 kJ/mol and those of the system with 5 and 10 phr of PGE- DMU were 43.4 and 37.0 kJ/mol, respectively. Ozawa method also showed the same tendency.

  • PDF

Design Factor Calculation and Analysis of Grid-Connected Photovoltaic System (계통연계형 태양광발전시스템의 설계계수 산출분석)

  • So, Jung-Hun;Hwang, Hye-Mi;Jung, Young-Seok;Ko, Suk-Whan;Ju, Young-Chul;Lim, Hyun-Mook
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.5
    • /
    • pp.89-94
    • /
    • 2013
  • This paper presents a simple but valid design factor calculation method of grid-connected photovoltaic system using normalized yield model. The proposed calculation method can be represented as a quantitative value about five design factors from irradiance to system output power. The validity of this method is identified by analyzing design factor with three years monitored data. These results will indicate that it is useful to determine the optimal design and selection of grid-connected photovoltaic system to meet different user purposes and enhance long-term reliability and stability of grid-connected photovoltaic system.

Investigation of an Infrared Temperature Measurement System for Thermal Safety Verification of Plasma Skin Treatment Devices

  • Choi, Jong-ryul;Kim, Wookeun;Kang, Bongkeun;Song, Tae-Ha;Baek, Hee Gyu;Han, Yeong Gil;Park, Jungmoon;Seo, Soowon
    • Current Optics and Photonics
    • /
    • v.1 no.5
    • /
    • pp.500-504
    • /
    • 2017
  • In this paper, we developed a temperature measurement system based on an infrared temperature imaging module for thermal safety verification of a plasma skin treatment device (PSTD). We tested a pilot product of the low-temperature PSTD using the system, and the temperature increase of each plasma torch was well-monitored in real-time. Additionally, through the approximation of the temperature increase of the plasma torches, a certain limitation of the plasma treatment time on skin was established with the International Electrotechnical Commission (IEC) guideline. We determined an appropriate plasma treatment time ($T_{Safe}$ < 24 minutes) using the configured temperature measurement system. We believe that the temperature measurement system has a potential to be employed for testing thermal safety and suitability of various medical devices and industrial instruments.

The developement of multi-layer sterilizer using Ultra Violet irradiation (자외선 조사를 이용한 다단계 컨베이어 자동 살균기 개발에 관한 연구)

  • Kim, Y.C.;Yoo, G.H.;Jung, Y.G.;Kim, H.S.;Jung, T.S.;Yun, B.S.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07g
    • /
    • pp.3060-3063
    • /
    • 1999
  • We made a multi-layer conveyor sterilizing system using UV rays to prolong a storage period of dried marine products. The system is composed of 5 layer conveyor belt of 3 m long each, thus 15 m long in total. It is designed to radiate UV rays for 10 minutes the dried marine products, and can process 300 kg/hour. Eight UV lamps of 30 cm long and 15 W of power with 254 nm wave length are installed in parallel, 15 cm high above in each belt, and 40 lamps in total. The whole system is covered by 1 mm thick metal plates to block the UV rays except a front side which is covered with 5 mm thick plastic plates coated with UV protection film to survey inside of the system. A sterile ratio is about 99.97% with 10 minutes sterilization using this system.

  • PDF

Development of an automatic measurement system for the AC-DC current transfer difference of the thermal current converter (열전형 전류 변환기의 교류-직류 전류 변환차이 자동측정시스템 개발)

  • Kwon, Sung-Won;Jung, Jae-Kap;Kim, Mun-Seog;Kim, Kye-Tae;Ryu, Je-Cheon
    • Journal of Sensor Science and Technology
    • /
    • v.14 no.5
    • /
    • pp.350-356
    • /
    • 2005
  • We have developed a dual-channel type automatic measurement system to evaluate AC-DC current transfer difference of the thermal current converter(TCC) which is primary standard of AC current. The output drift effect of the TCC is minimized by measuring simultaneously the output voltages of two TCCs using voltmeter. Furthermore, the offset voltage of the voltmeter is cancelled nearly out by taking the average values of two outputs of TCCs measured with the forward-reverse directions using dual channel scanner. The uncertainties of the automatic system were 7 to $86{\mu}A/A$ for 3 mA to 10 A at 40 Hz to 20 kHz, which were evaluated by the comparisons between adjacent range of TCCs and inter-comparison with national measurement institute of Germany(PTB). The capability for ac-dc transfer difference measurement was improved by one order compared with that for the manual ac-dc measurement system.

Communication Architecture of the IEC 61850-based Micro Grid System

  • Yoo, Byong-Kwan;Yang, Seung-Ho;Yang, Hyo-Sik;Kim, Won-Yong;Jeong, Yu-Seok;Han, Byung-Moon;Jang, Kwang-Soo
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.5
    • /
    • pp.605-612
    • /
    • 2011
  • As the power grids are integrated into one big umbrella called a "smart grid," communication protocol plays a key role in successful operations. The successful deployment of smart grid interoperability is a major hurdle that must be overcome. The micro grid, a small power system that distributes energy resource, is operated in diverse regions. Different vendors use different communication protocols in the operation of the micro grid. Recently, the IEC 61850 has been legislated to solve the interoperability problems in power utility automation. The present paper presents a micro grid system based on the IEC 61850 protocol. It consists of a micro grid monitoring system, a protocol converter that transforms serial data to IEC 61850 data, and distributed energy resource controllers for diverse DER nodes. A developed communication gateway can be deployed for DER controllers with serial links to exchange data with IEC 61850-based devices. The gateway can be extended to IEC 61850-based distribution automation systems, substation automation systems, or SCADA.

Cure Characteristics and Mechanical Properties of Ternary Accelerator System in NR/BR Compounds (NR/BR Compounds의 가황촉진제 병용에 의한 가황 특성 및 기계적 물성 연구)

  • Kim, Il-Jin;Kim, Wook-Soo;Lee, Dong-Hyun;Bae, Jong-Woo;Byon, Young-Hoo;Kim, Wonho
    • Korean Chemical Engineering Research
    • /
    • v.47 no.4
    • /
    • pp.403-409
    • /
    • 2009
  • In the 1840s, Goodyear found out sulfur cure system, but cure time was too slow. So producing of rubber product takes a long time. In 1904, Oenslager et al. found that aniline is accelerated sulfur cure system. Recently, many rubber industries needed high yield and good quality. So, many researchers have studied a rubber system with fast vulcanization time and good mechanical properties. In this study, cure characteristics and mechanical properties of NR/BR compounds by accelerator with MBTS(2,2' Dithiobisbenzothiazole), TMTM(Tetramethylthiuram Monosulfide), ZDMC (Zinc dimethyldithiocarbamate), CBS(N-Cyclohexyl benzothiazolyl-2-sulfenamide), DPG(Diphenylguanidine) were evaluated. The results of the study indicate that cure charateristics($t_{90}$: 235 sec, $T_{max}$: 5.77 Nm) and mechanical properties (100, 300% modulus : 2,180, 5.656 Mpa and tear strength: 59.58 kgf/cm) of NR/BR compounds shows efficient acceleration with MBTS 1.5 phr, TMTM 0.5 phr, DPG 0.15phr. This is due to the synergistic activity of ternary accelerator system in rubber vulcanization.

Multichannel Audio Reproduction Technology based on 10.2ch for UHDTV (UHDTV를 위한 10.2 채널 기반 다채널 오디오 재현 기술)

  • Lee, Tae-Jin;Yoo, Jae-Hyoun;Seo, Jeong-Il;Kang, Kyeong-Ok;Kim, Whan-Woo
    • Journal of Broadcast Engineering
    • /
    • v.17 no.5
    • /
    • pp.827-837
    • /
    • 2012
  • As broadcasting environments change rapidly to digital, user requirements for next-generation broadcasting service which surpass current HDTV service become bigger and bigger. The next-generation broadcasting service progress from 2D to 3D, from HD to UHD and from 5.1ch audio to more than 10ch audio for high quality realistic broadcasting service. In this paper, we propose 10.2ch based multichannel audio reproduction system for UHDTV. The 10.2ch-based audio reproduction system add two side loudspeakers to enhance the surround sound localization effect and add two height and one ceiling loudspeakers to enhance the elevation localization effect. To evaluate the proposed system, we used APM(Auditory Process Model) for objective localization test and conducted subjective localization test. As a result of objective/subjective localization test, the proposed system shows the statistically same performance compare with 22.2ch audio system and shows the significantly better performance compared with 5.1ch audio system.

Development of an IGVM Integrated Navigation System for Vehicular Lane-Level Guidance Services

  • Cho, Seong Yun
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.5 no.3
    • /
    • pp.119-129
    • /
    • 2016
  • This paper presents an integrated navigation system for accurate navigation solution-based safety and convenience services in the vehicular augmented reality (AR)-head up display (HUD) system. For lane-level guidance service, especially, an accurate navigation system is essential. To achieve this, an inertial navigation system (INS)/global positioning system (GPS)/vision/digital map (IGVM) integrated navigation system has been developing. In this paper, the concept of the integrated navigation system is introduced and is implemented based on a multi-model switching filter and vehicle status decided by using the GPS data and inertial measurement unit (IMU) measurements. The performance of the implemented navigation system is verified experimentally.