• Title/Summary/Keyword: K5 system

Search Result 31,957, Processing Time 0.059 seconds

Health monitoring of a bridge system using strong motion data

  • Mosalam, K.M.;Arici, Y.
    • Smart Structures and Systems
    • /
    • v.5 no.4
    • /
    • pp.427-442
    • /
    • 2009
  • In this paper, the acceptability of system identification results for health monitoring of instrumented bridges is addressed. This is conducted by comparing the confidence intervals of identified modal parameters for a bridge in California, namely Truckee I80/Truckee river bridge, with the change of these parameters caused by several damage scenarios. A challenge to the accuracy of the identified modal parameters involves consequences regarding the damage detection and health monitoring, as some of the identified modal information is essentially not useable for acquiring a reliable damage diagnosis of the bridge system. Use of strong motion data has limitations that should not be ignored. The results and conclusions underline these limitations while presenting the opportunities offered by system identification using strong motion data for better understanding and monitoring the health of bridge systems.

A SYSTEM OF NONLINEAR VARIATIONAL INCLUSIONS WITH GENERAL H-MONOTONE OPERATORS IN BANACH SPACES

  • Li, Jinsong;Wang, Wei;Cho, Min-Hyung;Kang, Shin-Min
    • East Asian mathematical journal
    • /
    • v.26 no.5
    • /
    • pp.671-680
    • /
    • 2010
  • A system of nonlinear variational inclusions involving general H-monotone operators in Banach spaces is introduced. Using the resolvent operator technique, we suggest an iterative algorithm for finding approximate solutions to the system of nonlinear variational inclusions, and establish the existence of solutions and convergence of the iterative algorithm for the system of nonlinear variational inclusions.

Characteristics of Thermodynamic Performance of Organic Flash Cycle (OFC) with Double Expansion (이중 팽창을 채용한 유기 플래시 사이클(OFC)의 열역학적 성능 특성)

  • KIM, KYOUNG HOON;HAN, CHUL HO;JUNG, YOUNG GUAN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.29 no.5
    • /
    • pp.483-489
    • /
    • 2018
  • Recently proposed organic flash cycle (OFC) was shown to potentially improve power generation using low grade heat source. In this paper, a thermodynamic performance is carried out for a modified OFC employed double expansions. Effects of the selection of working fluid and the important system parameters such as the temperatures in flash evaporators on the system performance were extensively investigated. Results showed that the system performances are strongly influenced with the system parameters and selection of the working fluid, and the power generation can be increased compared to the basic OFC.

Sliding Mode Control based on Disturbance Observer for Magnetic Levitation Positioning Stage

  • Zhang, Shansi;Ma, Shuyuan;Wang, Weiming
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.5
    • /
    • pp.2116-2124
    • /
    • 2018
  • Magnetic levitation system with the advantages of non-contact, no friction and no wear can satisfy the requirement of high precision and high speed positioning. In this paper, magnetic levitation positioning stage which mainly consists of planar coil and HALBACH permanent magnet array and its control and driving system are designed. Magnetic levitation system is a highly nonlinear and strongly coupled complex system and its control performance can be influenced by the uncertainty and external disturbance. So exact feedback linearization method is used to realize exact linearization and decoupling, and a strategy of sliding mode control based on disturbance observer is proposed to compensate the uncertainty and external disturbance. Detailed proofs of observer's convergence property and system stability are derived. Both the simulation and experiment results verify the effectiveness of sliding mode control algorithm based on disturbance observer.

System Level ESD Analysis - A Comprehensive Review II on ESD Coupling Analysis Techniques

  • Yousaf, Jawad;Lee, Hosang;Nah, Wansoo
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.5
    • /
    • pp.2033-2044
    • /
    • 2018
  • This study presents states-of-the art overview of the system level electrostatic discharge (ESD) analysis and testing. After brief description of ESD compliance standards and ESD coupling mechanisms, the study provides an in-depth review and comparison of the various techniques for the system level ESD coupling analysis using time and frequency domain techniques, full wave electromagnetic modeling and hybrid modeling. The methods used for improving system level ESD testing using troubleshooting and determining the root causes of soft failures, the optimization of ESD testing and the countermeasures to mitigate ESD problems are also discussed.

Enhanced Liver Targeting by Synthesis of $N_{\b{1}}-Stearyl-5-Fu$ and Incorporation into Solid lipid Nanoparticles

  • Yu, Bo-Tao;Xun-Sun;Zhang, Zhi-Rong
    • Archives of Pharmacal Research
    • /
    • v.26 no.12
    • /
    • pp.1096-1101
    • /
    • 2003
  • To enhance the liver targeting and reduce the side effects of 5-fluorouracil (5-Fu), it was acylated by stearyl chloride to obtain .$\b{N}_{\b{1}}$stearyl-5-Fu (5-FuS). The chemical structure of the prodrug was confirmed by Nuclear Magnetic Resonance and Infrared Spectrometry. 5-FuS was incorporated into solid lipid nanoparticles (SLN), which were prepared by the physical agglomeration method. The mean diameter of 5-FuS-SLN was 240.19 nm and the drug loading was 20.53%. The release characteristics in vitro of 5-FuS-SLN were fitted to the first-order pharmacokinetic model. Compared with 5-Fu injection, a study on the distribution of 5-FuS-SLN in mice showed that 5-FuS-SLN could double 5-Fu concentration in mice livers. The main pharmacokinetic parameters of 5-FuS-SLN in rabbits is shown as follows: $V_d$=0.04336L/kg, $T_{1/2} \beta$=1.2834h, CL=0.1632 L/h. In conclusion, 5-FuS-SLN has significant liver targeting properties. The employment of a prodrug to enhance drug liposoluble properties and the preparation method presented in this paper, seem to be an alternative strategy to the traditional colloidal delivery system.

Effect of DyFeO3 Addition on Crystal Structure and Ferrcelectricity of the BiFeO3-PbTiO3 System

  • Kim, Seong-Seog;Kwon, Jong-Uk;Cheon, Chae Il
    • Journal of the Korean Ceramic Society
    • /
    • v.42 no.5 s.276
    • /
    • pp.299-303
    • /
    • 2005
  • The crystal structure and ferroelectricity of the $(1-x)BiFeO_3\;(BF)-xPbTiO_3$ (PT) ceramic system with the addition of $DyFeO_3$ (DF) have been investigated for attaining a high temperature piezoelectric material. This study is focused on the relation between crystal structure and ferroelectric property with the addition of DF over the phase boundary in the (1-x)BF-xPT system. Hysteresis curves of polarization-electric field at room temperature have been measured. The X-ray and neutron diffraction data were analyzed by the rietveld refinement method. The addition of 0.1 mole DF into BF-PT system greatly increases the ferroelectric remanant polarization Pr values, e.g. 17 ${\mu}C/cm^2$ in 0.6BF-yDF-(0.4-y)PT and 31${\mu}C/cm^2$ in 0.5BF-yDF-(0.5.y)PT, respectively. The improved Pr value has been discussed in relation with crystal structure and electrical property.

Prediction of Pressure Drop Using the Internal Flow Simulation of Pulse Air Jet Bag Filters (충격기류식 여과집진기의 내부 유동 시뮬레이션 해석을 통한 압력손실 예측)

  • Jang, Kyeong-Min;Jung, Eun-Sang;Suh, Jeong-Min
    • Journal of Environmental Science International
    • /
    • v.29 no.5
    • /
    • pp.457-468
    • /
    • 2020
  • With continuous industrial development, the types, and amount of particulate matter (PM) have been increasing. Since 2018, environmental standards regarding PM have become more stringent. Pulse air jet bag filters are suitable for PM under the 20 ㎛ and, can function regardless of size, concentration and type. Filtration velocity and shape are important factors in the operation and design of the pulse air jet bag filters however, few established studies support this theory. In this research, numerical simulations were conducted based on experimental values and, several methods were employed for minimizing the pressure drop. In the pilot system, as the inlet duct velocity was faster than 19 m/sec, flow was not distributed equally and, re-entrainment occurred due to the hopper directional vortex. The multi-inlet system decelerated the hopper directional vortex by 25 ~ 30%, thereby decreasing total pressure drop by 6.6 ~ 14.7%. The guide vane system blocked the hopper directional vortex, which resulted optimal vane angle of 53°. The total pressure of the guide vane system increased by 0.5 ~ 3% at 1.5 m/min conditions. However, the filtration pressure drop decreased by 4.8 ~ 12.3% in all conditions, thereby reducing the operating cost of filter bags.

Manufature of Telemetry System for Multiple Subjects Using CMOS Custom IC (전용 CMOS IC에 의한 다중 생체 텔레미트리 시스템 제작)

  • Choi, Se-Gon;Seo, Hee-Don;Park, Jong-Dae;Kim, Jae-Mun
    • Journal of Sensor Science and Technology
    • /
    • v.5 no.1
    • /
    • pp.43-50
    • /
    • 1996
  • This paper presents a manufacture of the multiple subjects biotelemetry system using custom CMOS IC fabricated $1.5{\mu}m$ n-well process technology. The implantable circuits of the system except sensor interface circuits including FM transmitter are fabricated on a single chip with the sire of $4{\times}4mm^{2}$. It is possible to assemble the implantable system in a hybrid package as small as $3{\times}3{\times}2.5cm$ by using this chip, It's main function is to enable continuous measurement simultaneously up to 7-channel physiological signals from the selected one among 8 subjects. Another features of this system are to enable continuous measurement of physiological signals, and to accomplish ON/OFF switching of an implanted battery by subject selection signal with command signal from the external circuit. If this system is coupled with another appropriate sensors in medical field, various physiological parameters such as pressure, pH and temperature are to be measured effectively in the near future.

  • PDF

Research Trend in 5G-TSN for Industrial IoT (Industrial IoT를 위한 5G-TSN 기술 동향)

  • Kim, K.S.;Kang, Y.H.;Kim, C.K.
    • Electronics and Telecommunications Trends
    • /
    • v.35 no.5
    • /
    • pp.43-56
    • /
    • 2020
  • The 5G system standardization body has been developing standard functions to provide ultra-high speed, ultra-high reliability, ultra-low latency, and ultra-connected services. In 3GPP Rel-16, which was recently completed, this system has begun to develop ultra-high reliability and ultra-low latency communication functions to support the vertical industry. It is expected that the trend in the adoption of mobile communication by the vertical industry will continue with the introduction of 5G. In this paper, we present the industrial Internet-of-Things (IIoT) service scenarios and requirements for the adoption of 5G systems by the vertical industry and the related standardization trend at present. In particular, we introduce the 5G time-sensitive networking standard technology, a core technology for realizing 5G-based smart factories, for IIoT services.