• 제목/요약/키워드: K5 system

검색결과 31,959건 처리시간 0.062초

학교 건물에 설치된 지열원 열펌프 시스템의 실사용을 통한 냉난방성능 연구 (Cooling and Heating Performance Under the Actual Operating Condition of a Ground Source Heat Pump System in a School Building)

  • 김의영;정영만;송재도;이재근;김인규;이동혁
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.586-589
    • /
    • 2009
  • This paper presents the performance of a water-to-refrigerant type ground source heat pump (GSHP) system installed in a school building in Korea. For analyzing the performance of the GSHP system, we monitored various operating conditions, including the outdoor temperature, the ground temperature, and the input power of the GSHP system. The average cooling coefficient of performance (COP) of the heat pump was found to be 8.5 at 60% partial load condition, while the overall system COP was found to be 5.9. The average heating COP of the heat pump was found to be 6.5 at 45% partial load condition, while the overall system COP was found to be 5.0.

  • PDF

5″ FED True Color 구동시스템 설계 (Design of 5" True Color FED Driving System)

  • 신홍재;최창운;김진;최정옥;권오경
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 하계종합학술대회 논문집(5)
    • /
    • pp.65-68
    • /
    • 2000
  • We design a new driving system of 5" true color FED using current controlled PWM method. Further more, we successfully developed a 5" FED panel, which resolution is 320$\times$240(Color). When we design a 5" FED driving circuit, FED tips are modeled as R-C for circuit simulator of FED driving circuit. In Video data processing, parallel R, G, B input signals is processed independently, so duty ratio increase and no noise, high quality performance is achieved in display of 5" FED. The luminance is about 100cd/$m^2$, the anode power consumption Is 2.1W and total power of the driving system is 21.54W

  • PDF

한국 소방용 방화복의 치수체계 개발 (Sizing System Development of Korean Structural Firefighting Protective Clothing)

  • 한설아;남윤자;최영림
    • 한국의류학회지
    • /
    • 제33권5호
    • /
    • pp.827-839
    • /
    • 2009
  • Sizing system of Korean structural firefighting protective clothing that is national approved should be met for specification of structural firefighting protective clothing that is identified by Ministry of Public Administration and Security(MOPAS). However if you look over the specification of sizing system, the standard is based on only 'height' and the others are indicated as the size of completed product. KS K ISO 13688 and EN 340 which is met on ISO 13688 which indicates sizing system about protective clothing has the standards of height, chest and waist circumference. Also NFPA 1971 that has standards of sizing system is based on chest circumference, cervical to wrist length, waist circumference and inseam. That is different from Korean standards. Therefore, fire fighting protective clothing standards which is based on only height should be compensated and not be relied on foreign standards like ISO. It is indispensable for developing our own sizing system of structural fire fighting protective clothing. In this studying, Korean new sizing system of structural fire fighting protective clothing was developed for providing basic information of ergonomic structural fire fighting protective clothing. The analyzed target age was between 20 and 59 years old fire fighter who extinguish the fire. And it was analyzed by 3D measurement among data of the $5^{th}$ Size Korea. On conclusion, in case of structural fire fighting protective clothing coat, physical dimension was to be chest circumference, cervical to wrist length. Three dimensions as 5cm space of circumference and four dimensions as 2.5cm space of cervical to wrist length were derived, which means that totally 12 dimensions were defined. Dimension standards of pants was based on the analysis of waist circumference and crotch height. Six dimensions as 5cm space of waist circumference and three dimensions as 5cm space of crotch height were derived, which means that totally 14 dimensions were defined.

분광복사조도 측정 장치 개발 (Development of Spectral Irradiance Measurement System)

  • 서정철
    • 조명전기설비학회논문지
    • /
    • 제18권5호
    • /
    • pp.48-53
    • /
    • 2004
  • 광원의 분광복사조도를 250∼1600[nm] 파장 영역에서 정확하게 측정하기 위한 분광복사조도 측정 장치를 개발하였다. 분광복사조도 측정 장치는 광원 장치, 광학계, 분광장치, 광검출장치, 신호 처리 장치 등으로 이루어져 있다. 광검출 장치는 PMT, Si, InGaAs 및 IR enhanced InGaAs 광검출기를 이용함으로써 자외선, 가시광선, 적외선을 포함하는 넓은 파장 범위에서 광원의 스펙트럼을 측정할 수 있다. 개발된 측정 장치를 이용하여 1[kW] quartz-halogen 텅스텐 전구의 분광복사조도를 측정하여 비교하였는데, 측정 결과와 NIST에서 측정된 결과와는 차이는 450∼700[nm] 파장 영역에서 3[%] 이하이며, 700∼1600[m] 파장영역에서는 3.5[%] 이하이며, 250∼400[nm] 파장영역에서는 5[%] 이하로 측정되었다.

간호전달 체계 개선 방안 - 일 병동을 중심으로 - (Nursing Delivery System Improvement Plan in A Hospital)

  • 이진희;이승애;함용희;양명주;김옥선
    • 한국의료질향상학회지
    • /
    • 제3권2호
    • /
    • pp.52-59
    • /
    • 1997
  • Background : In many Nursing Delivery System, Nursing Department at D Hospital had used to traditional nursing practice model what is called functional activities based system. It has a lot of merit that carried out specialized and rapid works but tend to ignore indivisual professional responsibility and task-based work assignments. In addition this system showed high turnover rates due to heavy workload, timesum of handing over duties, lack of support from peers and interstaff communication. So we performed conversion of Nursing Delivery System to My Patients Nursing Care System for providing comprehensive nursing to patient and reducing turnover rates and increasing job satisfaction to nurse. Method : 1. 1st step(96.4.9): Detected the problem of Nursing delivery System and estabilished improving planning 2. 2nd step(96.4.26): Visited other hospital on job training 3. 3th step(96.4.29): Discussed to premonitoring problem after conversion Nursing Delivery System and prepared structure 4. 4th step(96.5.6): My Patients Nursing Care System practical application 5. 5th step(96.7.20): Held complementary meeting 6. 6th step(96. 7): The other ward application 7. 7th step(96. 10): Extended application to whole wards Results: 1. Workload: (1) reduction(55.6%) (2) addition(44.4%) 2. Strong points after conversion: (1) decreased timesum of handing overduties (35.2%) (2) increased responsibility(33%) (3) broaden nurse's outlook to duties(14.8%) 3. Shortcoming after conversion: (1) understanding difficulties except my patient(57.8%) (2) weak teamwork(23.3%) (3) intensive stress to low grade nurse(12.2%) 4. Effective complemental way: (1) manpower(76.7%) (2) conversion of though (8.9%) (3) education(14.4%) 5. Patient's satisfaction: (1) satisfaction(64%) (2) no effect(36%) 6. Physician and peer's satisfaction: (1) satisfaction(12.5%) (2) dissatisfaction(21.6%) (3) no interest(44.3%) 7. Nurse's satisfaction: (1) satisfaction(74.7%) (2) dissatisfaction(5.5%) (3) unknown(20.5%) 8. Want to continued: (1) want(76.4%) (2) try to any other system(18%) Conclusion : Even though Nursing Delivery System conversion still has many problem, we gained more merits than traditional nursing delivery system. So we suggest that My Patients Nursing Care System should be encouraged for comprehensive nursing care and satisfaction to nurses.

  • PDF

5.9kW 인산형 연료전지 발전시스템의 설계, 구성 및 특성 연구 (A Study on the Design, Fabrication and Characteristcs of the 5.9kW PAFC Power Generation System)

  • 이선근;신동렬;정두환;이원용;임희천;이창우;최수현
    • 대한전기학회논문지
    • /
    • 제43권4호
    • /
    • pp.569-579
    • /
    • 1994
  • A 5.9kW phosphoric acid fuel cell(PAFC) power generation system that consists of a reformer, a stack, heat exchangers, an automatic data acquisition and control system was designed, fabricated and analyzed. This system which was firstly fabricated in Korea has been operated for 140 hours with an electricity generation of 684kWh. The PAFC generate electricity in the range of 38-52V and 50-160A and has a typical I-V characteristics of a fuel cell. Using the reformed fuel, the system performance is decreased in some degree due to CO content, compared to using the simulated fuel. At steady state operation condition, the total efficency of this system was 45.2%.

도로터널의 모사시험을 통한 배수공 스케일 억제 기술 평가 (An Evaluation of Treatment Technologies for Anti-scale in Drainage Works Using Simulation Test of Road Tunnel)

  • 박은형;남중우;한윤수;김현기;천병식
    • 한국지반공학회논문집
    • /
    • 제29권7호
    • /
    • pp.5-15
    • /
    • 2013
  • 노후화된 터널에서 배수공의 막힘현상은 중요한 문제점으로 대두되며, 장기적으로는 배수시스템에 폐색현상을 일으킨다. 배수시스템에서의 침전물 방지를 위한 요소기술 검증을 위해 본 연구에서는 도로터널의 토사층 및 라이닝을 모사하여 배수공의 유출수에서의 침전현상을 살펴보았다. 또한 기존의 배수공들은 대부분$5^{\circ}$ 이하로 설치되었기 때문에 배수공의 기울기를 변화시켜가며 시험하였다. 배수공의 기울기를 $2^{\circ}$로 한 경우에는 퀀텀스틱은 스케일의 생성을 방지하는 데 효과가 있었으나 자화장치는 효과가 없는 것으로 나타났다. 배수공의 기울기를 $5^{\circ}$로 한 경우에는 퀀텀스틱과 자화장치 모두 배수공내 스케일의 생성을 방지하는 데 효과가 있었으나, 특히 퀀텀스틱이 자화장치보다 더욱 효과가 있는 것으로 나타났다.

Vacuum Test of Cavity with Liquid Nitrogen

  • Choi, Suk;Park, Gunn-Tae;Kim, Heetae
    • Applied Science and Convergence Technology
    • /
    • 제24권5호
    • /
    • pp.132-135
    • /
    • 2015
  • Schematic of RAON vacuum system is introduced. Vacuum test for superconducting cavity with liquid nitrogen is performed. Schematic plan for RAON vacuum system is introduced and vacuum control system for superconducting cavity test is constructed. Vacuum pressure of cavity is shown as a function of pumping time. The temperature of cavity is shown as a function of cooling time. Outgassing species from cavity is also detected. Detailed experimental procedure is presented to test the cavity vacuum with liquid nitrogen.

화학공정에서의 플래어 시스템 안전성 향상 방안 (A Study on the Safety Improvement at the Flare System in the Chemical Process)

  • 마병철;권혁면;김영철
    • 한국안전학회지
    • /
    • 제27권5호
    • /
    • pp.55-63
    • /
    • 2012
  • The purpose of this study is to suggest new safety code to improve the safety of the flare safety system. Firstly, we analyzed the major accidents occurred at the flare system since 1996 and proposed 3 articles which is required to be added newly to the existing KOSHA code. Secondly, we also performed the HAZOP study for each study node and also suggested 5 articles. Finally, we analyzed the commented contents of PSM reports which have been submitted from the enterprise located in Honam province since 2005 and proposed 5 articles as well. We understand that all 13 articles proposed above, should be added to the KOSHA code in order to improve the safety in the flare system and to prevent the major fire and explosion accidents in the design stage.

Effects of Synthetic Pseudoceramides on Sphingosine Kinase Activity in F9-12 Cells

  • Jin, You-Xun;Shin, Kyong-Oh;Park, Myung-Yong;Lee, Shin-Hee;Park, Byeong-Deog;Oh, Sei-Kwan;Yoo, Hwan-Soo;Lee, Yong-Moon
    • Biomolecules & Therapeutics
    • /
    • 제19권1호
    • /
    • pp.134-139
    • /
    • 2011
  • Sphingosine kinase (SPHK) has a central role to control cell death and cell proliferation, which is suggested as a sphingolipid rheostat by regulating the levels between ceramide and sphingosine 1-phosphate (S1P). Therefore, physiological regulators of SPHK will be a good candidate to develop a new targeted drug. For this purpose, a series of synthetic pseudoceramides were tested by SPHK assay either cell-based or cell-free system. K10PC-5 strongly inhibited SPHK, while K6PC-5 activated SPHK in cell-free system. Specifically, K6PC-5 activated SPHK under the co-treatment with $50\;{\mu}M$ dimethylsphingosine (DMS), a SPHK inhibitor. Collectively, we developed a simple SPHK assay system to find SPHK regulatory pseudoceramide compounds, K10PC-5 and K6PC-5 which may be useful to cancer treatment or immune regulation like FTY720, a synthetic sphingolipid mimetic compound.