• Title/Summary/Keyword: K5 system

Search Result 31,957, Processing Time 0.057 seconds

PERFORMANCE EVALUATION OF DIGITAL DATA PROCESSING SYSTEM FOR KOREAN VLBI NETWORK(KVN) (KVN을 위한 디지털 데이터 처리 시스템의 성능평가)

  • Oh, Se-Jin;Roh, Duk-Gyoo;Yeom, Jae-Hwan;Byun, Do-Young;Lee, Chang-Hoon;Chung, Hyun-Soo;Je, Do-Heung;Wajima, Kiyoaki;Kawakami, Kazuyuki
    • Publications of The Korean Astronomical Society
    • /
    • v.22 no.3
    • /
    • pp.63-73
    • /
    • 2007
  • In this paper, we introduce the performance test results of digital data processing system for KVN (Korean VLBI Network). The digital data processing system for KVN consists of DAS (Data Acquisition System) and high-speed recorder which called Mark5B system. DAS system performs the digitalization of analog radio signal through ADS-1000 gigabit sampler with 1 Gsps/2-bit and process the digital filtering of digital signal. Mark5B system records the output data of DFB (Digital Filter Bank) with about 1 Gbps. In this paper, we carried out the preliminary evaluation experiments of the KVN digital data processing system connected between DAS system and Mark5B with VSI (VLBI Standard Interface) interface which is designed for compatible in each VLBI system. We first performed all of the KVN digital data processing system connected by VSI interface in the world. In factory inspection phase, we found that the DAS system has a memory read/write error in DSM (Digital Spectrometer) by analyzing the recorded data in Mark5B system. We confirmed that the DSM memory error has been correctly solved by comparing DSM results with Mark5B results. The effectiveness of KVN digital data processing system has been verified through the preliminary experiments such as data transmission, recording with VSI interface connection and data analysis between DSM and Mark5B system. In future work, we will perform the real astronomical observation by using the KVN 21m radio telescopes so as to verify its stability and performance.

Field study of 5kW class PEMFC system (5kW급 고분자전해질 연료전지 시스템 실증연구)

  • Lee, SooJae;Choi, Dae Hyun;Jun, HeeKwon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.87.1-87.1
    • /
    • 2011
  • The residential Fuel Cell system has high efficiency of 85% with transferring natural gas to electrical power and heat, directly and it is a friendly environmental new technology in that $CO_2$ emission can reduce 40% compared with conventional power generator and boiler. The residential fuel cell system consists of two main parts which have electrical and hot storage units. The electrical unit contains a fuel processor, a stack, an inverter, a control unit and balance of plant(BOP), and the cogeneration unit has heat exchanger, hot water tank, and auxiliaries. 5kW class fuel process was developed and tested from 2009, it was evaluated for long-term durability and reliability test including with improvement in optimal operation logic. Stack development was crried out through improvement of design and evaluation protocol. Development of system controller was successfully accomplished through strenuous efforts and original control logic was optimized in 5kW class PEMFC system. In addition, we have been focused on development of system process and assembly technology, which bring about excellent improvement of reliability of system. The 5kW class PEMFC system was operated under dynamic conditions for 1,000 hours and it showed a good performance of total efficiency and durability.

  • PDF

A Study on Code Assist Method of HTML5 Components (HTML5 기반 컴포넌트에 대한 코드 어시스트 구현 방안 연구)

  • Kang, Jea-Gyu;Yu, Yeon-Hee;Choi, Yong-Ho;Kim, Jang-Goon;Park, Hun-Beom
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2014.11a
    • /
    • pp.1032-1034
    • /
    • 2014
  • 표준 웹 환경의 확산으로 HTML5를 기반으로 웹 저작을 지원하는 많은 WYSIWYG HTML5 저작도구들이 등장하고 있다. 그러나 대부분의 WYSIWYG HTML5 저작도구는 컴포넌트 이벤트에 대한 기본적인 함수 작성 기능만 제공 할 뿐 컴포넌트 제어를 위한 코드 어시스트 기능을 제공하지 않고 있다. 본 논문에서는 이클립스 JSDT(JavaScript Development Tools) 코드 어시스트개념에 대해 기술하고, 이를 기반으로 WYSIWYG HTML5 저작도구에서 제공하는 컴포넌트 제어를 위해 코드 어시스트 가능을 구현하였다. 이로 인하여 WYSIWYG HTML5 저작도구에서 제공하는 컴포넌트에 대한 사용자들의 접근성과 개발 생산성 증대가 기대된다.

A Design of WYSIWYG HTML5 Editor (WYSIWYG기반의 HTML5 저작도구 설계)

  • Yeo, Sung-Jin;Lee, Cho-I;Choi, Yong-Ho;Kim, Jang-Goon;Park, Hun-Beom
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2014.11a
    • /
    • pp.1035-1038
    • /
    • 2014
  • 데스크탑, 태블릿, 스마트폰등 다양한 인터넷 접근방법과 크롬, 사파리, 파이어폭스등 다양한 브라우저가 사용됨에 따라 이런 여러 가지 인터넷 환경에 대응하기 위해 W3C에서는 HTML5를 권고하고 있으며 이에 따른 표준화를 진행하고 있다. 전 세계적으로 HTML5로의 전환을 빠르게 확산시키려는 움직임을 보이고 있으나 선도 기업을 제외한 공공기관 및 민간 기업에서는 전문 인력 부족, 학습 비용 투자 등 여러 가지 문제로 인해 전환속도가 미흡한 실정이다. 본 논문에서는 HTML5에 대한 국내외 표준화 및 시장현황에 대해 기술하고, 이를 기반으로 WYSIWYG HTML5 저작도구를 설계하였다.

The development of High efficiency fuel processor for technical independence 5kW class fuel cell system (기술자립형 5kW 연료전지 시스템 구축을 위한 고효율 연료변환기 개발)

  • Lee, Soojae;Choi, Daehyun;Jun, Heekwon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.123.2-123.2
    • /
    • 2010
  • Fuel Cell cogeneration system is a promising technology for generating electricity and heat with high efficiency of low pollutant emission. We have been developed 5kW class fuel cell cogeneration system for commercial and residential application. The fuel processor is a crucial part of producing hydrogen from the fossil fuels such as LNG and LPG. The 5kW class high efficiency fuel processor consists of steam reformer, CO shift converter, CO preferential oxidation(PrOx) reactor, burner and heat exchanger. The one-stage CO shift converter process using a metal oxide catalyst was adopted. The efficiency of 5 kW class fuel processor shows 75% based on LHV. In addition, for the purpose of continuous operation with load fluctuations in the commercial system for residential use, load change of fuel processor was tested. Efficiency of 30%, 50%, 70% and 100% load shows 75%, 75%, 73% and 72%(LHV), respectively. Also, during the load change conditions, the product gas composition was stable and the outlet CO concentration was below 5 ppm. The Fuel processor operation was carried out in residential fuel cell cogeneration system with fuel cell stack under dynamic conditions. The 5kW class fuel processor have been evaluated for long-term durability and reliability test including with improvement in optimal operation logic.

  • PDF

De-NOx Characteristics for Cu-ZSM5/Alumina Beads Catalyst Filter in Urea-SCR System (Urea-SCR 시스템에서의 Cu-ZSM5/알루미나 비드 촉매필터의 De-NOx 특성)

  • Jang, Young-Sang;Shin, Young-Seop;Lee, Byoung-Jun;Park, Jai-Koo
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.5
    • /
    • pp.60-67
    • /
    • 2008
  • The catalytic filter of Cu-ZSM5/alumina beads was considered to reduce NOx in the urea SCR system. Catalytic support of porous alumina beads with mean pore size $130{\mu}m$ and porosity $75{\sim}83%$ were prepared using foaming and gel-casting method. The Cu-ZSM5 catalysts were coated on the supporting alumina beads using $Cu(NO_3)_2$ by ion exchange method. After a washcoating process was applied to coat 10w% Cu-ZSM5 on porous alumina bead, coating layer was estimated $20{\mu}m$ in thickness. The characterization and the feasibility as a catalytic supports were investigated. And the NOx conversion test in Cu-ZSM5/Alumina Beads filter system was conducted by using Urea as reductants under laboratory test. The NOx conversion was increased as size and porosity of beads and observed more than 95% excellent NOx conversion above $300^{\circ}C$.

Operation Results of a 5kW-Class SOFC System Composed of 2 Sub-Module Stacks (2 모듈 스택을 이용한 5kW급 SOFC 시스템 운전결과)

  • Lee, Tae-Hee;Choi, Mi-Hwa;Yoo, Young-Sung
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.22 no.5
    • /
    • pp.609-615
    • /
    • 2011
  • A 5 kW class SOFC system for cogeneration power units was consisted of a hot box part and cold BOPs. High temperature components such as a stack, a fuel reformer, a catalytic combustor, and heat exchanges are arranged in the bot box considering their operating temperatures for the system efficiency. The hot box was made of ceramic boards for the thermal insulation. A 5 kW class SOFC stack was composed of 2 sub-modules and each module had 64 cells with $15{\times}15cm^2$ area and stainless steel interconnects. The 5 kW class SOFC system was operated with a hydrogen and a city gas. With a hydrogen, the total power of the stacks was about 7.1 kWDC and electrical efficiency was about 49.3% at 80 A. With a city gas, the total power of the stacks was about 5.7 $kW_{DC}$ and electrical efficiency was about 38.8% at 60 A. Under self-sustained operating condition, the system efficiency including a power conditioning loss and a consumed power by BOPs was about 30.2%.

Operation of the Radio Occultation Mission in KOMPSAT-5

  • Choi, Man-Soo;Lee, Woo-Kyoung;Cho, Sung-Ki;Park, Jong-Uk
    • Journal of Astronomy and Space Sciences
    • /
    • v.27 no.4
    • /
    • pp.345-352
    • /
    • 2010
  • Korea multi-purpose satellite-5 (KOMPSAT-5) is a low earth orbit (LEO) satellite scheduled to be launched in 2010. To satisfy the precision orbit determination (POD) requirement for a high resolution synthetic aperture radar image of KOMPSAT-5, KOMPSAT-5 has atmosphere occultation POD (AOPOD) system which consists of a space-borne dual frequency global positioning system (GPS) receiver and a laser retro reflector array. A space-borne dual frequency GPS receiver on a LEO satellite provides position data for the POD and radio occultation data for scientific applications. This paper describes an overview of AOPOD system and operation concepts of the radio occultation mission in KOMPSAT-5. We showed AOPOD system satisfies the requirements of KOMPSAT-5 in performance and stability.

An Experimental Study on a Windheat Generation System with a Savonius Wind Turbine

  • Kim, Young-Jung;Ryou, Young-Sun;Kang, Geum-Choon;Paek, Yee;Yun, Jin-Ha;Kang, Youn-Ku
    • Agricultural and Biosystems Engineering
    • /
    • v.6 no.2
    • /
    • pp.65-69
    • /
    • 2005
  • A windheat generation system with a Savonius windturbine was developed and the performance was evaluated through field tests. The system consisted of a heat generation drum, heat exchanger, water storage tank, and two circulation pumps. Frictional heat is created by rotation of a rotor inside the drum containing thermo oil, and was used to heat water. In order to estimate the capacity of this windheat generation system, weather data was collected for one year at the site near the windheat generation system. Wind Power from the savonius wind turbine mill was transmitted to the heat generation system with an one-to-three gear system. Starting force to rotate the savonius wind turbine and the whole system including the windheat generation system were 1.0 and 2.5 kg, respectively. Under the outdoor wind condition, maximum speed of the rotor in the drum was 75rpm at wind speed 6.5 m/sec, which was not fast enough to produce heat for greenhouse heating. Annual cumulative hours for wind speeds greater than 5 m/sec at height of 10, 20, 30 m were 190, 300 and 1020 hrs, respectively. A $5^{\circ}C$ increase in water temperature was achieved by the windheat generation system under the tested wind environment.

  • PDF

A 3 ~ 5 GHz CMOS UWB Radar Chip for Surveillance and Biometric Applications

  • Lee, Seung-Jun;Ha, Jong-Ok;Jung, Seung-Hwan;Yoo, Hyun-Jin;Chun, Young-Hoon;Kim, Wan-Sik;Lee, Noh-Bok;Eo, Yun-Seong
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.11 no.4
    • /
    • pp.238-246
    • /
    • 2011
  • A 3-5 GHz UWB radar chip in 0.13 ${\mu}m$ CMOS process is presented in this paper. The UWB radar transceiver for surveillance and biometric applications adopts the equivalent time sampling architecture and 4-channel time interleaved samplers to relax the impractical sampling frequency and enhance the overall scanning time. The RF front end (RFFE) includes the wideband LNA and 4-way RF power splitter, and the analog signal processing part consists of the high speed track & hold (T&H) / sample & hold (S&H) and integrator. The interleaved timing clocks are generated using a delay locked loop. The UWB transmitter employs the digitally synthesized topology. The measured NF of RFFE is 9.5 dB in 3-5 GHz. And DLL timing resolution is 50 ps. The measured spectrum of UWB transmitter shows the center frequency within 3-5 GHz satisfying the FCC spectrum mask. The power consumption of receiver and transmitter are 106.5 mW and 57 mW at 1.5 V supply, respectively.