• Title/Summary/Keyword: K-ratio method

Search Result 10,014, Processing Time 0.039 seconds

A new contrast ratio measurement method using image patterns

  • Choi, Dong-Wook;Yang, Sun-A;Bae, Jae-Woo;Lee, Seung-Bae;Chung, Ho-Kyoon
    • Journal of Information Display
    • /
    • v.12 no.2
    • /
    • pp.85-87
    • /
    • 2011
  • The contrast ratio is one of the most important performance parameters for display devices. The general method of measuring the contrast ratio is to determine the ratio of the full-screen white pattern to the full-screen black pattern, according to the Video Electronics Standards Association standard. Real TV images seldom have these images, however, and the conventional method does not reflect the true performance of the display in actual use. In this paper, a new contrast ratio measurement method that uses image patterns is proposed, to demonstrate that active matrix organic light-emitting diode TVs have a higher contrast than LED (LCD) TVs.

THE GENERALIZED RATIO-OF-UNIFORM METHOD

  • Chung, Youn-Shik;Lee, Sang-Jeen
    • Journal of applied mathematics & informatics
    • /
    • v.4 no.2
    • /
    • pp.469-476
    • /
    • 1997
  • In this paper we present a random number generation method which is one of the rejection methods, To accelerate ratio-of-uniform method we use an efficiency variable γ. After finding the optimal value of γwith respect to interesting distribution with pro-portional density random numbers can be generated in acceleration.

A study on the threshold current ratio method using the measurement of coated facet reflectivity of a laser diode (레이저 다이오드의 코팅된 단면의 반사율 측정에 사용되는 문턱전류비에 관한 연구)

  • Lee, Sang-Moo;Kim, Boo-Gyoun
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.541-543
    • /
    • 1995
  • We propose the improved threshold current ratio method to determine the reflectivity of coated facets. The carrier recombination time used in the improved threshold current ratio method depends on the value of facet reflectivities. However, the carrier recombination time used in the conventional threshold current ratio method is constant regardless of facet reflectivities. The difference between the results of the two methods increases as the reflectivity of a coated facet decreases.

  • PDF

Importance Performance Analysis using SN ratio (SN비를 이용한 중요도 만족도 분석)

  • Cho, Yong-Wook
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.4
    • /
    • pp.397-403
    • /
    • 2014
  • The objective of this study is to provide improved methodology based on the IPA method. One case studies are solved by the proposed method. this study present the method that give value to use SN(Signal-to-Noise) ratio in IPA. A case study of lecture satisfaction are solved by the proposed method and the existing method. Also, the result is compared with the existing method using Mean and the proposed method using SN ratio.

Validity Examination on Evaluation of J-R Curve in the Nuclear Reactor Pressure Vessel Steels and Aluminum Alloys by Load Ratio Analysis (원자로 압력용기강 및 Al 합금재의 J-R곡선평가시 Load Ratio 해석의 유효성 검토)

  • Yoon, H.K.;Woo, D.H.;Kim, Y.K.;Cha, G.J.
    • Journal of Power System Engineering
    • /
    • v.1 no.1
    • /
    • pp.80-90
    • /
    • 1997
  • The purpose of this study is to evaluate the validity examination of the J-R curve characteristics for the nuclear reactor pressure vessel steels and Al alloys by the load ratio analysis. The results of the load ratio analysis are compared with those of the J-R curve which are obtained by the ASTM unloading compliance method. The crack length calculated by the load ratio analysis is agree well with the measured final crack length. The slope of the exponential J-R curve estimated by the load ratio analysis is slightly smaller than that by the ASTM unloading compliance method. The J-R curve obtained by the ASTM unloading compliance method is over-predicted and should be offsetted due to the initial negative crack. On the other hand, the load ratio analysis method can evaluate the J-R curve by only load-displacement curve without particular crack measurement equipment.

  • PDF

Evaluation Technique for Ratio Error of Current Transformer Comparator (전류변성기 비교기의 비오차 평가 기술)

  • Kim, Yoon-Hyoung;Han, Sang-Gil;Jung, Jae-Kap;Han, Sang-Ok
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.3
    • /
    • pp.291-295
    • /
    • 2008
  • We have developed an evaluation technique for ratio errors of current transformer (CT) comparator by using the precise standard capacitors. By applying this technique for equivalent circuit of CT comparator evaluation system, we can obtain the calculated and measured ratio errors in the CT comparator. Thus we can evaluate ratio errors of CT comparator by comparing the calculated and measured ratio errors. Because this method requires only the standard capacitors, it is simple and easy method to reliability and accuracy maintenance of CT comparator. The method was applied to CT comparator under test with the ratio error ranges of $0{\sim}{\pm}10%$. The ratio error of the CT comparator under test theoretically obtained in this method are consistent with that measured for same CT comparator under test by using wide ratio error CT within an estimated expanded uncertainty (k = 2) in the overall ratio error ranges.

Preparation and Characterization of Piroxicam/Poloxamer Solid Dispersion Prepared by Melting Method and Solvent Method

  • Yu, Hang;Chun, Myung-Kwan;Choi, Hoo-Kyun
    • Journal of Pharmaceutical Investigation
    • /
    • v.37 no.1
    • /
    • pp.1-5
    • /
    • 2007
  • Solid dispersions of piroxicam were prepared by melting method using poloxamer as a carrier. The results of DSC and XRD studies showed that the amorphous farm of piroxicam coexisted with the crystalline form in the solid dispersions. However, the ratio of crystalline form of piroxicam in the solid dispersion prepared by melting method decreased in comparison with the same ratio of the solid dispersion prepared by solvent method. As the ratio of poloxamer in the solid dispersion increased, the ratio of the amorphous form of piroxicam in the solid dispersion increased. The dissolution rate of piroxicam from the solid dispersions was significantly higher than that from piroxicam powder. In comparison to the solid dispersion prepared by solvent method, the dissolution rate of piroxicam from the solid dispersion prepared by melting method was higher. As the ratio of poloxamer in the solid dispersion prepared by melting method increased, the initial dissolution rate decreased, however, the total amount dissolved at the end of the study increased.

Computing Fractional Bayes Factor Using the Generalized Savage-Dickey Density Ratio

  • Younshik Chung;Lee, Sangjeen
    • Journal of the Korean Statistical Society
    • /
    • v.27 no.4
    • /
    • pp.385-396
    • /
    • 1998
  • A computing method of fractional Bayes factor (FBF) for a point null hypothesis is explained. We propose alternative form of FBF that is the product of density ratio and a quantity using the generalized Savage-Dickey density ratio method. When it is difficult to compute the alternative form of FBF analytically, each term of the proposed form can be estimated by MCMC method. Finally, two examples are given.

  • PDF

Experimental and Improved Numerical Studies on Aerodynamic Characteristics of Low Aspect Ratio Wings for a Wing-In Ground Effect Ship

  • Ahn, Byoung-Kwon;Kim, Hyung-Tae;Lee, Chang-Sup;Lew, Jae-Moon
    • Journal of Ship and Ocean Technology
    • /
    • v.12 no.3
    • /
    • pp.14-25
    • /
    • 2008
  • Recently, there has been a serious effort to design a wing in ground effect (WIG) craft. Vehicles of this type might use low aspect ratio wings defined as those with smaller than 3. Design and prediction techniques for fixed wings of relatively large aspect ratio are reasonably well developed. However, Aerodynamic problems related to vortex lift on wings of low aspect ratio have made it difficult to use existing techniques. In this work, we firstly focus on understanding aerodynamic characteristics of low aspect ratio wings and comparing the results from experimental measurements and currently available numerical predictions for both inviscid and viscous flows. Second, we apply an improved numerical method, "B-spline based high panel method with wake roll-up modeling", to the same problem.

Measurement Range Extension of AC High Voltage using two 200 kV Capacitive Dividers (200 kV 용량형 분압기 2대를 이용한 교류 고전압 측정범위 확장)

  • Jung, Jae-Kap;Lee, Sang-Hwa;Kang, Jeon-Hong;Kim, Myung-Soo;Kim, Yoon-Hyoung;Han, Sang-Gil;Jeong, Jin-Hye;Han, Sang-Ok;Joung, Jong-Man
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.1
    • /
    • pp.1-5
    • /
    • 2008
  • The output voltage value of AC high voltage source has been usually obtained by multiplying low voltage value measured at both terminals of low voltage resistor by the dividing ratio of the high voltage capacitive divider. From the dividing ratio determined of each 200 kV capacitive divider, we have developed step-up method for measuring the output voltage up to 400 kV using two same type of 200 kV capacitive dividers connected in series. The theoretical dividing ratio of 400 kV capacitive dividers connected in series coincides with that of manufacturer's certification within measurement uncertainty. Thus, this developed step-up method makes it possible to extend the range of output voltage from 200 kV to 400 kV. Furthermore, The dividing ratio of divider under test obtained using this step-up method is consistent with that obtained using one 200 kV high voltage divider within corresponding uncertainties.