• Title/Summary/Keyword: K-point

Search Result 28,036, Processing Time 0.054 seconds

Template-Based Reconstruction of Surface Mesh Animation from Point Cloud Animation

  • Park, Sang Il;Lim, Seong-Jae
    • ETRI Journal
    • /
    • v.36 no.6
    • /
    • pp.1008-1015
    • /
    • 2014
  • In this paper, we present a method for reconstructing a surface mesh animation sequence from point cloud animation data. We mainly focus on the articulated body of a subject - the motion of which can be roughly described by its internal skeletal structure. The point cloud data is assumed to be captured independently without any inter-frame correspondence information. Using a template model that resembles the given subject, our basic idea for reconstructing the mesh animation is to deform the template model to fit to the point cloud (on a frame-by-frame basis) while maintaining inter-frame coherence. We first estimate the skeletal motion from the point cloud data. After applying the skeletal motion to the template surface, we refine it to fit to the point cloud data. We demonstrate the viability of the method by applying it to reconstruct a fast dancing motion.

Bone and Soft Tissue Changes after Two-Jaw Surgery in Cleft Patients

  • Yun, Yung Sang;Uhm, Ki Il;Kim, Jee Nam;Shin, Dong Hyeok;Choi, Hyun Gon;Kim, Soon Heum;Kim, Cheol Keun;Jo, Dong In
    • Archives of Plastic Surgery
    • /
    • v.42 no.4
    • /
    • pp.419-423
    • /
    • 2015
  • Background Orthognathic surgery is required in 25% to 35% of patients with a cleft lip and palate, for whom functional recovery and aesthetic improvement after surgery are important. The aim of this study was to examine maxillary and mandibular changes, along with concomitant soft tissue changes, in cleft patients who underwent LeFort I osteotomy and sagittal split ramus osteotomy (two-jaw surgery). Methods Twenty-eight cleft patients who underwent two-jaw surgery between August 2008 and November 2013 were included. Cephalometric analysis was conducted before and after surgery. Preoperative and postoperative measurements of the bone and soft tissue were compared. Results The mean horizontal advancement of the maxilla (point A) was 6.12 mm, while that of the mandible (point B) was -5.19 mm. The mean point A-nasion-point B angle was $-4.1^{\circ}$ before surgery, and increased to $2.5^{\circ}$ after surgery. The mean nasolabial angle was $72.7^{\circ}$ before surgery, and increased to $88.7^{\circ}$ after surgery. The mean minimal distance between Rickett's E-line and the upper lip was 6.52 mm before surgery and 1.81 mm after surgery. The ratio of soft tissue change to bone change was 0.55 between point A and point A' and 0.93 between point B and point B'. Conclusions Patients with cleft lip and palate who underwent two-jaw surgery showed optimal soft tissue changes. The position of the soft tissue (point A') was shifted by a distance equal to 55% of the change in the maxillary bone. Therefore, bone surgery without soft tissue correction can achieve good aesthetic results.

THE STUDY ON COURSE OF THE INFERIOR ALVEOLAR CANAL IN THE MANDIBULAR RAMUS USING CONEBEAM CT (하악지에서의 하치조신경관 주행에 대한 Conebeam CT를 이용한 연구)

  • Kim, Hyong-Woo;Kwon, Kyung-Hwan;Min, Seung-Ki;Oh, Seung-Hwan;Chee, Young-Deok;Koh, Se-Wook;Lee, Jae-Hwan;Ohn, Byung-Hun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.31 no.5
    • /
    • pp.386-393
    • /
    • 2009
  • Objectives: This study was performed to evaluate course of the inferior alveolar canal in the mandibular ramus and to find safety zone when ramal bone is harvested. Patients and Methods: From January, 2009 to February, 2009, the 20 patients who visited in the Department of Oral and Maxillofacial Surgery, Sanbon Dental Hospital. Wonkwang University and the Conebeam CT was taken of various chief complaints, were selected. The patients who had left and right mandibular first molar and incisor missing, jaw fracture and bone pathology were excluded. The R point was defined as the point which occlusal plane was crossed to the mandibular anterior ramus(external oblique ridge). In the cross-sectional coronal and axial views, the inferior alveolar canal position to the R point, buccal bone width(BW), alveolar crest distance(ACD), distance from alveolar crest to occlusal plane(COD) and inferior alveolar canal to sagittal plane(CS) were measured and horizontal distance(HD), vertical distance(VD) and nearest distance(ND) were measured. Results: The inferior alveolar canal is located $6.19{\pm}1.21\;mm$ from the R point. Horizontal distance from the R point were $13.07{\pm}2.45\;mm$, vertical distance from the R point were $14.24{\pm}2.41\;mm$ and nearest distance from the R point were $10.12{\pm}1.76\;mm$. The course of the inferior alveolar canal was positioned within $0.61{\pm}0.68\;mm$. The distance from external buccal bone to the inferior alveolar canal was increased from the R point anteriorly. Conclusions: It is considered that the mandibular ramus from the R point to 10 mm anteriorly can be harvested safely at ramal bone grafting.

Calculation of the Hydrocarbon and Water Dew points of Natural Gas (천연가스의 탄화수소 및 물 이슬점 계산)

  • Ha, Youngcheol;Lee, Seongmin;Her, Jaeyoung;Lee, Kangjin;Lee, Seunjun
    • Korean Chemical Engineering Research
    • /
    • v.47 no.5
    • /
    • pp.565-571
    • /
    • 2009
  • This study was conducted to evaluate hydrocarbon and water dew points of natural gas. For this purpose, algorithm of suppressing divergence was devised to evaluate hydrocarbon dew point up to near critical point and algorithm for finding water dew points lower than that of hydrocarbon, which cannot be calculated by commercial dew point program, was developed. The evaluated values were compared to commercial program and ISO reference values, and the results showed that deviations were zero.

Development of Posture Evaluation System through Digital Recognition Method (디지털 영상인식 방법을 통한 자세평가 및 운동가동범위 측정시스템 개발)

  • Moon, Young-Jin;Lee, Soon-Ho;Back, Jin-Ho;Lee, Jong-Gak;Lee, Gun-Bum
    • Korean Journal of Applied Biomechanics
    • /
    • v.14 no.3
    • /
    • pp.49-65
    • /
    • 2004
  • The purpose of this study is development of posture evaluation and Range of Motion(ROM) system by using digital vision analysis method. The results of this study are as follows. First, Scoliosis evaluation through this research measurement system represent 3mm error in 7 cervical point and deepest lumbar point, 0.7mm error in other point. This mean this research measurement system have a reliability for scoliosis evaluation. Second, for spine line evaluation on high fat subject, we need reconstrection spine line after measurement for fat thickness in 7 cervical point and deepest lumbar point. Third, In pedioscope error test, it present 0.01848cm in X axis and 0.01757cm in Y axis. This results mean pedioscope have a reliability foot evaluation. Forth, Posture evaluation and Range of Motion measurement system by using digital vision analysis method can fast measure in range of motion and foot evaluation and posture. therefore we can expect this system application in young people posture clinic center and hospital and so on.

A Study on the Real Power Optimization Using Interior-Point Method (IP법을 이용한 유효전력제어에 관한 연구)

  • Jung, Soon-Young;Jung, Jai-Kil;Lee, In-Yong;Jung, In-Hak;Hyun, Seung-Bum
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.99-101
    • /
    • 2000
  • Different optimization algorithms have been proposed to solve real and reactive power optimization problems. Most of all, linear programming techniques that employed a simplex method have been extensively used. But, the growth in the size of power systems demands faster and more reliable optimization techniques. An Interior Point(IP) mehod is based on an interior point approach to aim the solution trajectory toward the optimal point and is converged to the solution faster than the simplex method. This paper deals with the use of Successive Linear Programming(SLP) for the solution of the Security Constrained Economic Dispatch(SCED) problem. This problem is solved using the IP method. A comparison with simplex method shows that the interior point technique is reliable and faster than the simplex algorithm.

  • PDF

Criterion for judging seismic failure of suspen-domes based on strain energy density

  • Zhang, Ming;Parke, Gerry;Tian, Shixuan;Huang, Yanxia;Zhou, Guangchun
    • Earthquakes and Structures
    • /
    • v.15 no.2
    • /
    • pp.123-132
    • /
    • 2018
  • In this paper the strain energy density (SED) model is used to analyze the seismic behavior of suspen-domes and a new criterion is established for judging the seismic failure based on a characteristic point in the SED model. Firstly, a nonlinear time-history response analysis was carried out using the finite-element package ANSYS for typical suspen-domes subjected to different ground motions. The seismic responses including nodal displacements, ratios of yielding members, strain energy density and structural maximum deformation energy were extracted corresponding to the increasing peak ground acceleration (A). Secondly, the SED sum ($I_d$) was calculated which revealed that the $I_d-A$ curve exhibited a relatively large change (called a characteristic point) at a certain value of A with a very small load increment after the structures entered the elastic-plastic state. Thirdly, a SED criterion is proposed to judge the seismic failure load based on the characteristic point. Subsequently, the case study verifies the characteristic point and the proposed SED criterion. Finally, this paper describes the unity and application of the SED criterion. The SED method may open a new way for structural appraisal and the SED criterion might give a unified criterion for predicting the failure loads of various structures subjected to dynamic loads.

Multi-point detection of hydrogen using the hetero-core structured optical fiber hydrogen tip sensors and Pseudorandom Noise code correlation reflectometry

  • Hosoki, Ai;Nishiyama, Michiko;Igawa, Hirotaka;Seki, Atsushi;Watanabe, Kazuhiro
    • Journal of Power System Engineering
    • /
    • v.19 no.3
    • /
    • pp.11-15
    • /
    • 2015
  • In this paper, the multi-point hydrogen detection system based on the combination of the hetero-core optical fiber SPR hydrogen tip sensor and interrogator by pseudorandom noise (PN) code correlation reflectometry has been developed. In a light intensity-based experiment with an LED operating at 850 nm, it has been presented that a transmitted loss change of 0.32dB was induced with a response time of 25 s for 4% $H_2$ in $N_2$ in the case of the 25-nm Au, 60-nm $Ta_2O_5$, and 5-nm Pd multi-layers film. The proposed sensor characteristic shows excellent reproducibility in terms of loss level and time response for the in- and out- $H_2$ action. In addition, in the experiment for multi-point hydrogen detection, all sensors show the real-time response for 4% hydrogen adding with reproducible working. As a result, the real-time multi-point hydrogen detection could be realized by means of the combination of interrogating system and hetero-core optical fiber SPR hydrogen tip sensors.

GENERATION OF DEM FROM CONTOURS FOR THE ORTHORECTIFICATION OF HIGH-RESOLUTION STELLITE IMAGES

  • Choi, Joon-Soo;Cha, Young-Min;Heo, Jae-Wee;Ryu, Young-Soo;Kim, Choen;Oh, Seung-Jun
    • Proceedings of the KSRS Conference
    • /
    • 2008.10a
    • /
    • pp.7-10
    • /
    • 2008
  • We present a technique for constructing a digital elevation model (DEM) from contours. The elevation of each ground point in DEM is computed by interpolating the heights of the two adjacent contours of the point. The technique decomposes each sub-domain between adjacent contours into a set of sub-regions. The decomposition is accomplished by constructing a medial axis of the sub-domain. Each sub-region in the decomposition is classified into a variety of terrain features like hillsides, valleys, ridges, etc. The elevations of points are interpolated with different methods according to terrain features they belong to. For a given point in hillside, an approximate gradient line passing through the point is determined and the elevation of the point is interpolated from the known elevations of the two adjacent contours along the approximate gradient line. The univariate monotone rational Hermite spline is used for the interpolation. The DEM constructed by the technique is to be used to orthorectify the high-resolution KOMPSAT3 imagery.

  • PDF

Measurement of Flash Point for Binary Mixtures of Methanol, Ethanol, 1-propanol and Toluene (Methanol, Ethanol, 1-propanol 그리고 Toluene 이성분 혼합계에 대한 인화점 측정)

  • Hwang, In Chan;Kim, Seon Woo;In, Se Jin
    • Fire Science and Engineering
    • /
    • v.32 no.1
    • /
    • pp.1-6
    • /
    • 2018
  • The flash point is one of the most important parameters used to characterize the ignition and explosion hazards of liquids. Flash points were measured for several binary systems containing toluene, including {methanol+toluene}, {ethanol+toluene}, and {1-propanol+toluene}. Experiments were performed according to the standard test method using a SETA closed cup flash point tester. The measured flash points were compared with the predicted values calculated using the following $G^E$ models: Wilson, NRTL, and UNIQUAC. The average absolute deviation between the predicted and measured lower flash point was less than 1.69 K.