• Title/Summary/Keyword: K-Sure

Search Result 642, Processing Time 0.033 seconds

One Case Report of Somatoform Disorder Patient with Dyspnea, Dysarthria and Gait Disturbance (호흡곤란, 구음장애, 보행장애 증상을 보인 신체형 장애 환자 치료 1례 보고)

  • Kim, Ja-Young;Seo, Joo-Hee;Kang, Hyun-Sun;Sung, Woo-Young;Jeong, Da-Un
    • Journal of Oriental Neuropsychiatry
    • /
    • v.18 no.3
    • /
    • pp.237-247
    • /
    • 2007
  • People with somatoform disorder have a number of different symptoms that typically last for several years. Their symptoms can't be traced to a specific physical cause. In people with somatoform disorder, medical test results are either normal or don't explain the person's symptoms. The symptoms of somatoform disorder are similar to the symptoms of other illnesses. People with this disorder may have several medical evaluations and tests to be sure that they don't have another illness. In this case, we described a 56-year old man who was diagnosed as R/O) ALS, because he has many similar symptoms of ALS (amyotrophic lateral sclerosis) such as gait disturbance, dysarthria, dyspnea. But we diagnosed his case as somatoform disorder and treated with herbal medication, acupuncure treatment ,negative cupping and relaxation training. Through these treatment, the patient showed improvement of chief complains and accessory symptoms.

  • PDF

Field Application of AC High Voltage Test after Installation for EHV XLPE Power Cables (초고압 XLPE 전력케이블에 대한 설치후 교류내전압시험 현장적용)

  • Kim, Y.;Kwon, B.I.;Seong, J.K.;Han, C.S.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1768-1770
    • /
    • 2001
  • EHV power cables can take any damage during shipping, transportation, handling, storage and installation. As the damage influences a reliability of the power cable system in the short and long periods, field tests have been required, for installers, to confirm the reliability of an installed system and, for utilities, to make sure the compatibility of an installed system. Of field tests, a HV withstand test for the cable insulation has been performed to check the soundness of the insulation. For EHV XLPE power cables, the test has been done by applying a specified d.c voltage till lately. But as some problems with the d.c test is emphasized and the equipment for the a.c test is improved, the a.c test is considered positively as an after-installation test. This paper describes the recent trends of the a and its recent application in the field.

  • PDF

Characteristics Analysis of Flex Link according to Mold Clamping Force in Injection Molding Machine (형체력에 따른 사출성형기 플렉스링크의 특성 분석)

  • Jung, Hyun Suk;Yoo, Joong Hak
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.31 no.2
    • /
    • pp.165-170
    • /
    • 2014
  • Reproducibility of injection molding machines are studied at the study of this time. We applied computer aided engineering program so it could generate clamping force, about 1,500 kN, to the nozzle center part of flex link in tie-bar and at this time, we made sure condition of stress distribution and transformation quantity in flex link. The result of computer aided engineering transformation quantity was confirmed that transformation of top area was 247~257 kN and bottom areas was 273~279 kN and also was confirmed that the stresses are distributed in a range of 57~750 $N/mm^2$ from top to the bottom of the surface. This time we could confirm the condition of transformation quantity and stress distribution by enforcing the previously used structure analysis of flex link. And we utilized the reference data to establish important point of section for non destructive test overhaul.

The Power Supply for High Frequency Induction Heating by using the Current Resonance (전류공진을 이용한 고주파 유도가열용 전원장치)

  • Ra, B.H.;Lee, E.Y.;Song, D.H.;Suh, K.Y.;Lee, H.W.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11d
    • /
    • pp.263-266
    • /
    • 2002
  • In this paper, It is indicating that an issues of the conventional boost converter for high frequency induction heating. To improve those issues, it is proposed, simulated and analyzed that the current resonant circuit, simulated. As the result, we knew that the proposed circuit has a good point to improve the waveform of input current and to make high efficiency. On the other side, in the inverter for the high current power supply, it is proposed that the high frequency inverter of the half bridge topology, be done the circuit analysis to extract the optimal circuit parameter. It is making sure of the soft switching operating by the inductor to reverse parallel connected on the inverter main switch, decreasing the surge voltage when the switch is turn-off by compulsion, and repressing the switch current and bringing the high current amplitude operation by the multi resonance.

  • PDF

A Case Study on Cut Slope Failure due to the Geomorphological Factor (지형요인에 의한 절토사면 붕괴사례)

  • Kim, Seung-Hyun;Choi, Ji-Yong;Rhee, Jong-Hyun;Lee, Jung-Yup;Koo, Ho-Bon
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.1161-1170
    • /
    • 2009
  • The Roads in Gangwon Province generally was made on purpose to use the military road. In case of these roads, tremendous dangerous cut slopes do exist and its road linear shape was badly designed. In order to make up for this situation, the government has continuously established the new road or performed the public works such as the straight line of the curved road. Soksil 2 cut slope was made through the road improvement work. This has small surface failures and collapses. In spite of dry season, this slope are leaking lots of groundwater at the unbelievable point. So as to get curious phenomenon right, we performed a detailed field investigation, the geomorphological analysis, the stability analysis considering field characteristic and ultimately proposed the countermeasure to make sure stability of Sokil 2 cut slope.

  • PDF

A Study for Deformation During the Erection of LNG Carrier's Motor/Compressor Room (액화천연가스운반선 모터/컴프레서 룸의 탑재 시 처짐에 대한 검토 사례 소개)

  • Oh, Chang-Min;Jang, Yoo-Soo;Oh, Dong-Yoon;Yang, Jin-Seok
    • Special Issue of the Society of Naval Architects of Korea
    • /
    • 2007.09a
    • /
    • pp.1-6
    • /
    • 2007
  • To improve productivity of the LNG carriers which are growing bigger and bigger, many researches are being carried out by shipyards. In this regard, we reviewed possible problems which could occur during the erection of 216K LNG carrier's motor/compressor room with all outfittings pre-installed. As a first item, the weights of hull and outfittings were precisely estimated to make sure that the erection is carried out within yard's capability. In the next place, deflection and safety of the structure were verified by FEM analysis. As a result, the erection was finished successfully and yard's productivity was also improved. This review is a good example which shows the importance of through study and preparation for improving yard's productivity which is already reached its limit.

  • PDF

Study on the Morphology Evolution of PS/HDPE Blend During Uniaxial Elongational Flow (일축신장흐름에서의 PS/HDPE Blend의 모폴로지 변화에 관한 연구)

  • Hong, Jung-Sook;Son, Jung-Wu;Lee, Seung-Jae;Ahn, Kyung-Hyun;Lee, Seung-Jong
    • Proceedings of the Korean Society of Rheology Conference
    • /
    • 2001.06a
    • /
    • pp.11-14
    • /
    • 2001
  • Our study have aimed to identify the deformation and breakup mechanism of minor phase in polymer blends under uniaxial enlongational flow. Experimentally, we measured the transient elongational viscosity of PS/HDPE blends using the uniaxial elongational rheometer at two temperatures. And we observed the evolution of blend morphology with elongation time. Morphological change was observed by quenching the specimen after deformation. If the viscosity variation of PS was compared with that of HDPE at each temperature, PS showed larger temperature dependence than HDPE. At 155$^{\circ}C$, the dispersed phase of larger size were easily affected by affine deformation. The initial spherical shape changed to flat ellipsoid at first, then flat ellipsoid to bulbous shape, and bulbous to thin thread and its satellites. But dispersed phase of smaller size showed the change from sphere to ellipsoid. At 175$^{\circ}C$, the dispersed phase were mostly deformed from spherical shape to ellipsoid. As a result, the morphological change of dispersed phase in elongational deformation is affected by chain flexibility and viscosity ratio. We need to further study to make sure the mechanism of elongation of viscoelastic polymer blends.

  • PDF

A Way to Further Understanding of Basic Engineering Principle by Supervising Junior High School Students through Sets of Science Experiment

  • Naim, Muhamad;Tsuzuki, Shozo;Fujisawa, Shoichiro;Hanabusa, Takao
    • Journal of Engineering Education Research
    • /
    • v.13 no.5
    • /
    • pp.25-28
    • /
    • 2010
  • The objective of this project is to cultivate interest among junior high school students toward Science & Technology. Six simple experiments will be introduced to the participants (junior high school students) of this project which is focusing on the basic principles of engineering including law of motion, free-fall, force, energy, friction and work. Our student team has been assigned to design six set of experiment according to the principles. The experiments are easy to understand and simple to assemble by the students of age 13 to 15. Experimental manuals were written by the members using simple words complete with figure so that all the participants can understand the procedure of each experiment. In order to make sure the manuals are practically working, the experiment sets were tested and the results were compared with actual theory. As a result, we believe that the experiments can be done by the students within less supervision. The students are able to set up the experiments by using some simple equipment around them. By doing this experiments, we can further our understanding and explain better the principles of energy, force and work.

  • PDF

A Study on the Safety and Improvement of Small Theatres in Korea (소규모 공연장 안전실태 및 개선방안에 대한 연구)

  • Park, Yong Gyu;Kim, Dong Kyun;Park, Jin Kyu;Kim, Kyung Hoon
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.6
    • /
    • pp.22-27
    • /
    • 2014
  • The market of performance arts industry such as concert, musical and opera etc is now expanding in Korea. However, the inadequate safety management in theatres often causes some accidents. The guarantee of safety in theatres is very important since the accidents in theaters can lead to many casualties and serious property damages. In particular, the small theatres which have no obligation of safety inspection by law are very vulnerable to safety mattes. This study has done the research into the improvement of safety in small theaters through the inspection and analysis of their safety status. For the purpose, this study has inspected and analyzed the safety status of small theaters over 120 in the field of theater management and operation, fire protection, electrical facilities, ceiling structure and etc. Moreover, this study had investigated the law and technical standards related to theatre safety. This study shows that the essentials to make sure of the safety in small theaters are (1) the education to improve the sense of security of people who work in theaters (2) the training to strengthen the operating skills of the facilities in theaters (3) the cooperation and support of the related organization such as technical research center, central and local government.

A proposal for the analysis of the PDA testing results of the extra-long piles (초장대말뚝의 동재하시험 해석방안)

  • Lee, Myung-Whan;Hong, Hun-Sung;Kim, Sung-Hoi;Jun, Young-Suk
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.1269-1278
    • /
    • 2006
  • These days the construction of extra-long piles increases. It is not unusual to install piles whose length exceed 45m. In such cases, the estimated value of negative skin friction becomes larger, often larger than the design load. In order to be sure of the safety of the super structure, the magnitude of the positive skin friction and the base bearing capacity should be known. In practice dynamic pile loading tests using PDA is the only possible measure to meet this requirement. However the analysis of dynamic pile loading test for such extra-long piles requires a thorough understanding of the pile-soil behaviour. In this paper, a new method to evaluate the positive skin friction and end bearing capacity from the normally performed PDA test is proposed. The proposed method was verified by performing specially designed pilot testings.

  • PDF