• Title/Summary/Keyword: K-S test

Search Result 24,621, Processing Time 0.047 seconds

Correlations among Respiratory Function, UPDRS and Senior Fitness in Parkinson's Disease Patients (파킨슨병환자의 호흡기능, UPDRS 및 Senior Fitness의 관련성)

  • Kang, Dong-Yeon;Cheon, Sang-Myung;Cheon, Sang-Myung;Lee, Kyung-Soon;Kim, Kyoung
    • The Journal of Korean Physical Therapy
    • /
    • v.26 no.2
    • /
    • pp.48-55
    • /
    • 2014
  • Purpose: The purpose of this study was to examine correlations among UPDRS, respiratory function, and senior fitness and to investigate the effects of restrictive respiratory function on these factors in Parkinson's disease patients. Methods: Subjects (n=25, Hoehn & Yahr (H&Y) stage: 2-3, $69.3{\pm}5.9$ yrs) from D Hospital Parkinson's Disease Center at Busan metropolitan area in the Republic of Korea volunteered for this study. They performed the pulmonary function test, UPDRS, and the senior fitness test. SPSS 18.0 was used for analysis of data, and the collected data were analyzed using Pearson's correlation coefficient (n=25). In addition, Independent t-test was used for determination of differences between two groups (between the normal pulmonary function group (n=10) and the restrictive pulmonary function group (n=10)). Results: Forced vital capacity (FVC (L)) showed significant negative correlation (r=-0.44, p<0.05) with H&Y stage in Parkinson's disease patients, and chair stand showed significant negative correlations (r=0.41, 0.43, 0.42, p<0.05) with FVC (L), FVC (%), and FEV1 (L). FVC (%) showed significant positive correlations (r=0.44, r=0.44, p<0.05) with right and left back scratch. In addition, the restrictive respiratory function group showed significantly lower FVC (%) (p<0.01) and was significantly slower (p<0.05) in the 8-foot up-and-go test than the normal respiratory function group. Conclusion: In conclusion, these results suggest that restrictive respiratory function in PD was related to H&Y stage. In addition, agility of PD patients was lower in the restrictive respiratory function group than in the normal function group.

Test results of a 5 kW fully superconducting homopolar motor

  • Lee, J.K.;Park, S.H.;Kim, Y.;Lee, S.;Joo, H.G.;Kim, W.S.;Choi, K.;Hahn, S.Y.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.15 no.1
    • /
    • pp.35-39
    • /
    • 2013
  • The superconducting Homopolar motor is manufactured and tested. Homopolar motor system is simple and solid as the field coil of the motor is fixed near the stator coil without rotating system. In this paper, a 5 kW fully superconducting homopolar motor which has high temperature superconducting armature and field coils is manufactured and tested in liquid nitrogen. The critical current test results of the used 2G superconducting wire, pancake coil for rotor winding and race-track coils for armature winding are reported. Also, the test result of rotating and operating performance is presented. The operating frequency is to be 5 Hz for low-speed rotating. The developed fully superconducting Homopolar motor is the world's first.

Comparison of Loss Characteristics of High-Efficiency Induction Motor by Parameter Measurement Test (정수 측정 시험에 의한 고효율 유도 전동기의 손실 특성 비교)

  • Pyon, H.S.;Kim, S.C.;Yang, S.H.;Hahn, S.C.;Joo, S.W.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07a
    • /
    • pp.318-320
    • /
    • 1999
  • Electric motor transforms electric power into mechanical power. It is important to increase efficiency of motor to save energy and to decrease operating cost. In this paper, some parameters and losses of high-efficiency induction motor and standard induction motor are measured by blocked-rotor test and no-load test. Operational parameters of high-efficiency induction motor that are compared with those of standard motor.

  • PDF

A Study on the manufacturing Composite Insulator for 170kV D/S (170kV급 단로기용 Composite Insulator 제조기술에 관한 연구)

  • Jin, S.Y.;Bae, K.S.;Lee, D.W.;Song, W.P.;Song, H.S.;Cho, H.G.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11a
    • /
    • pp.34-36
    • /
    • 2002
  • The objective of this study is to develop the composite insulator for 170kA disconnecting switch. In this paper, we have investigated the test procedure about each component(FRP tube, flange, shed) through technical standard(IEC 61462) and obtained demand characteristics by mechanical & electrical property test.

  • PDF

Studies on the Adhesion Part 1 The adhesive force of Chloroprene Rubber to Plywood material (접착(接着)에 관(關)한 연구(硏究)(제1보(第1報)) 접착력시험조건(接着力試驗條件)에 따른 접착력(接着力)에 관(關)하여)

  • Lee, Myung-Whan;Park, Chang-Ho
    • Elastomers and Composites
    • /
    • v.8 no.2
    • /
    • pp.140-147
    • /
    • 1973
  • The influence of the adhesive force test conditions on the resultant adhesive force was measured using a chloroprene rubber as an adhesive and a plywood as an adherent. It was clarified from the experiments which adhesive force test conditions could influence strongly the adhesive force. After this, the constant values neccessary as the test conditions of the adhesive force in making generally a test of the adhesive force determined.

  • PDF

A Nonparametric Bootstrap Test and Estimation for Change

  • Kim, Jae-Hee
    • Communications for Statistical Applications and Methods
    • /
    • v.14 no.2
    • /
    • pp.443-457
    • /
    • 2007
  • This paper deals with the problem of testing the existence of change in mean and estimating the change-point using nonparametric bootstrap technique. A test statistic using Gombay and Horvath (1990)'s functional form is applied to derive a test statistic and nonparametric change-point estimator with bootstrapping idea. Achieved significance level of the test is calculated for the proposed test to show the evidence against the null hypothesis. MSE and percentiles of the bootstrap change-point estimators are given to show the distribution of the proposed estimator in simulation.

GENERALIZED MINIMUM $x^2$ TEST FOR THE EXTREME VALUES

  • Lee, Chun-Jin
    • Journal of applied mathematics & informatics
    • /
    • v.1 no.1
    • /
    • pp.43-48
    • /
    • 1994
  • There are some difficulties in applying the Pearson's Chi-Square Test for the continuous distribution. The problems include how to form class intervals for the test of fit how to employ in the test when the estimators of parameters are obtained from the ungrouped sample so on. In order to solve these problems we use the generalized minimum Chi-Square technique which is a test free of the complications associated with the Peason's Chi-Square test. This paper show how to apply the goodness of fit tests based on generalized minimum Chi-Square technique to the extreme values.

A Bayes Criterion for Testing Homogeneity of Two Multivariate Normal Covariances

  • Kim, Hea-Jung
    • Journal of the Korean Statistical Society
    • /
    • v.27 no.1
    • /
    • pp.11-23
    • /
    • 1998
  • A Bayes criterion for testing the equality of covariance matrices of two multivariate normal distributions is proposed and studied. Development of the criterion invloves calculation of Bayes factor using the imaginary sample method introduced by Spiegelhalter and Smith (1982). The criterion is designed to develop a Bayesian test criterion, so that it provides an alternative test criterion to those based upon asymptotic sampling theory (such as Box's M test criterion). For the constructed criterion, numerical studies demonstrate routine application and give comparisons with the traditional test criteria.

  • PDF

A study on OLED device's accelerated lifetime test (OLED 소자의 가속수명 시험에 관한 연구)

  • Choi, Young-Tae;Joe, Jae-Rib
    • Journal of the Korea Safety Management & Science
    • /
    • v.10 no.3
    • /
    • pp.73-79
    • /
    • 2008
  • Display's life time is defined as the time of 50% luminance drop. It was used luminance and temperature as accelerated factor to accelerated lifetime at test. When it's working jule-heat is generated and device's temperature is growing as any temperature because OLED is self-luminance display device. So we decided temperature condition is 25, $70^{\circ}C$, and luminance condition is $60{\sim}300cd/m^2$ in test. It's assumed accelerated lifetime model by result of the test.

DEVELOPMENT OF AN ACCELERATED LIFE TEST PROCEDURE FOR COOLING FAN MOTORS

  • Shin, W.G.;Lee, S.H.;Song, Y.S.
    • International Journal of Automotive Technology
    • /
    • v.7 no.6
    • /
    • pp.757-762
    • /
    • 2006
  • Reliability of automotive parts has been one of the most interesting fields in the automotive industry. Especially, a small DC motor was issued because of the increasing adoption for passengers' safety and convenience. For several years, small DC motors have been studied and some problems of a life test method were found out. The field condition was not considered enough in the old life test method. It also needed a lot of test time. For precise life estimation and accelerated life test, new life test procedure was developed based on measured field condition. The vibration condition on vehicle and latent force on fan motor shaft were measured and correlated with each other. We converted the acceleration data into the load data and calculated the equivalent load from integrated value. We found the relationship which can be used for accelerated life test without changing the severity by using different loading factors.