Search Result 10,687, Processing Time 0.053 seconds

Integration of SoC Test and Verification Using Embedded Processor and Reconfigurable Architecture (임베디드 프로세서와 재구성 가능한 구조를 이용한 SoC 테스트와 검증의 통합)

  • Kim Nam-Sub;Cho Won-Kyung
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.43 no.7 s.349
    • /
    • pp.38-49
    • /
    • 2006
  • In this paper, a novel concept based on embedded processor and reconfigurable logic is proposed for efficient manufacturing test and design verification. Unlike traditional gap between design verification and manufacturing test, proposed concept is to combine both design verification and manufacturing test. The semiconductor chip which is using the proposed concept is named "SwToC" and SwToC stands for System with Test On a Chip. SwToC has two main features. First, it has functional verification function on a chip and this function could be made by using embedded processor, reconfigurable logic and memory. Second, it has internal ATE on a chip and this feature also could be made by the same architecture. To evaluate the proposed SwToC, we have implemented SwToC using commercial FPGA device with embedded processor. Experimental results showed that the proposed chip is possible for real application and could have faster verification time than traditional simulation method. Moreover, test could be done using low cost ATE.

High-Temperature Fracture Strength of a CVD-SiC Coating Layer for TRISO Nuclear Fuel Particles by a Micro-Tensile Test

  • Lee, Hyun Min;Park, Kwi-Il;Park, Ji-Yeon;Kim, Weon-Ju;Kim, Do Kyung
    • Journal of the Korean Ceramic Society
    • /
    • v.52 no.6
    • /
    • pp.441-448
    • /
    • 2015
  • Silicon carbide (SiC) coatings for tri-isotropic (TRISO) nuclear fuel particles were fabricated using a chemical vapor deposition (CVD) process onto graphite. A micro-tensile-testing system was developed for the mechanical characterization of SiC coatings at high temperatures. The fracture strength of the SiC coatings was characterized by the developed micro-tensile test in the range of $25^{\circ}C$ to $1000^{\circ}C$. Two types of CVD-SiC films were prepared for the micro-tensile test. SiC-A exhibited a large grain size (0.4 ~ 0.6 m) and the [111] preferred orientation, while SiC-B had a small grain size (0.2 ~ 0.3 mm) and the [220] preferred orientation. Free silicon (Si) was co-deposited onto SiC-B, and stacking faults also existed in the SiC-B structure. The fracture strengths of the CVD-SiC coatings, as measured by the high-temperature micro-tensile test, decreased with the testing temperature. The high-temperature fracture strengths of CVD-SiC coatings were related to the microstructure and defects of the CVD-SiC coatings.

Development of 13C-urea-containing capsule for diagnosis of H. pylori (헬리코박터 파이로리 균 진단용 13C-요소 캅셀의 개발)

  • Yong, Chul-Soon;Kim, Yong-Il;Kim, Chi-Man;Kang, Sung-Hoon;Quan, Qi-Zhe;Rhee, Jong-Dal;Kim, Chong-Kook;Sah, Hong-Kee;Choi, Han-Gon
    • Journal of Pharmaceutical Investigation
    • /
    • v.32 no.1
    • /
    • pp.7-11
    • /
    • 2002
  • The purpose of this study was to develop a new $^{l3}C-urea-containing$ capsule for diagnosis of H. pylori. The urea-containing capsules were prepared with various diluents such as polyethylene glycol (PEG), microcrystalline cellulose, sodium lauryl sulfate and citric acid. The dissolution test, $^{l3}C-urea$ breath test and stability test were then performed on the capsules. Microcrystalline cellulose and sodium lauryl sulfate retarded the initial dissolution rates of urea. However, PEG increased the initial dissolution rates of urea. Furthermore, two formulae composed of PEG, [$^{l3}C-urea/PEG$ (38/1.9 mg/cap)] and [$^{l3}C-urea/PEG/citric$ acid (38/1.9/1.9 mg/cap)] had the maximum DOB value, about 16 at 20 mim, while the formula composed of only 38 mg $^{l3}C-urea$ had the maximum DOB value at 30 min. The results indicated that PEG improved the, sensitivity of $^{l3}C-urea$ in the human volunteers. The capsule [$^{l3}C-urea/PEG$ (38/1.9 mg/cap)] was stable for at least six months in 25 and $37^{\circ}C$. Thus, a PEG-containing capsule, [$^{l3}C-urea/PEG$ (38/1.9 mg/cap)] would be a more economical, sensitive and stable preparation for diagnosis of H. pylori.

The Study of Comparison with ANSI/IEEE and IEC for Short Circuit Test of Transformers (ANSI/IEEE와 IEC 규격(規格)에 따른 변압기(變壓器)의 단락강도시험(短絡强度試驗)의 비교(比較))

  • Kim, Sun-Koo;Kim, Sun-Ho;Kim, Won-Man;La, Dae-Ryeol;Roh, Chang-Il;Lee, Dong-Jun;Jung, Heung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.705-706
    • /
    • 2006
  • Generally Short Circuit Test of transformers are tested according to IEEE std C57.12.00-2000, IEC 60076-5(2000-07), ES148(1998.6.26) or KS C4309(2003). But ES148(1998.6.26) is same as IEEE std C57. 12.00-2000 and KS C4309(2003) is revising coincidence with IEC 60076-5(2000-07). On this study condition of the transformers before short circuit test, calculation method for test current peak value, tolerance on the asymmetrical peak and r.m.s value, short circuit testing procedure, number of short circuit test, duration short circuit test, and detection of faults and evaluation of short circuit test result will be compared with ANSI and IEC.

  • PDF

Design Example of Gravel Mat for Horizontal Drains (쇄석Mat를 이용한 수평배수공법 설계사례)

  • Jeong, Kyeong-Han;Lee, Young-Keun;Lee, See-Woo;Kim, Jae-Sung;Kim, Byung-Tak
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.10a
    • /
    • pp.174-187
    • /
    • 2005
  • Recently, because of environment, cost, supply and demand factors, though applying sea-sand as horizontal drains is getting difficult that usage of Gravel has been growing in large size of construction sites, Study on engineering properties and behavior characteristics of Gravel stratum is not thoroughgoing enough. We have applied Gravel Mat as the horizontal drains in O O construction site. We also conducted several field tests such as Material property test, Geosynthetics damage test with Repeated load, Discharge capacity test performed by inflow of upper soil and In-situ PBD Penetration test to review the application of Gravel Mat. Test results show that Gravel Mat is not only advantageous in Trafficability and Water drainage by Consolidation due to its great Internal friction angle and Permeability, but also easy to penetrate with Mandrel and has great discharge capacity and guarantee of the stability against geosynthetics damage at the same time. With these benefits Gravel Mat shows great application in fields.

  • PDF

Analysis of Diffusion Bonded Parts Using Immersed UT Method (수침초음파를 이용한 확산접합부평가)

  • Park, J.C.;Oh, C.S.;Kim, Y.S.;Kim, J.G.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.12 no.3
    • /
    • pp.33-39
    • /
    • 1992
  • This paper presents a summary of the immersion ultrasonic test to analyze the quality of diffusion bonding parts. The most important property of diffusion bonding parts is bonding strength, and that can be obtained by shear test. By comparing among data obtained by ultrasonic test(C-Scan) and those by shear test (bonding strength), these data are shown to be in good relation. Therefore ultrasonic C-Scan test result can be used successfully in quantitative quality control for diffusion bonded parts.

  • PDF

A Study on the breakdown reduction of porcelain insulators (자기제 애자의 절연파괴 감소대책 연구)

  • Song, I.K.;Park, K.P.;Kim, Y.L.;Kim, K.W.;Kwak, H.R.;Han, S.O.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1042-1044
    • /
    • 1995
  • This paper provides the results and analyses of investigations into porcelain suspension insulators failures on the KEPCO system. The high failure rate of suspension insulators on distribution lines has been attributed to the volume expansion of the cement, the insulation puncture breakdown of the porcelain and the power arc failure. The utility must use only the good insulators and at least reduce the insulator failure rate. So, this paper recommends that the utility make test criteria(cement expansion test, steep front-of-wave flashover voltage test and power arc test. etc) on the suspension insulators.

  • PDF

Application study of C.S.G method by the test construction and field test (시험시공 및 현장시험을 통한 C.S.G 공법의 적용성 검토)

  • Kim, Ki-Young;Park, Han-Gyu;Cho, Sung-Eun;Jeon, Je-Sung
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.61-68
    • /
    • 2006
  • Cemented Sand and Gravel(CSG) is a material made by simple mixing of rock-based raw materials such as excavated soil and riverbed gravel together with cement and water. The use of CSG methodl for cofferdam and large dam is gradually increasing in Japan because a quarry and aggregate plants can be diminished. Also, the CSG method can reduce dam construction cost, construction duration and destruction of environment. In this paper, field test and test construction of CSG method was conducted on Hwabuk Dam. The mechanical properties of CSG, such as compressive strength, extention strength and field permeability test were investigated. From the results of the experimental study, application study of CSG method was discussed.

  • PDF

Test Methods of Sealing Material for Plastic Liquid Crystal Display Cells

  • Hsiao, C.C.;Liao, Y.C.;Chang, K.H.;Sha, Y.A.;Su, P.J.;Hsieh, C.H.;Shiu, J.W.;Fuh, S.Y.;Lin, C.Y.;Cheng, W.Y.;Yang, J.C.;Lo, K.L.;Lee, D.W.;Lee, K.C.;Chang, Y.P.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.830-833
    • /
    • 2006
  • In this work, we provided a novel test method to verify the sealing materials for flexible LCD cell. The ultraviolet type curing sealing material with low process temperature was suitable for LCD cell assembly. We also proposed the sealing materials which passed 13200 times bending test within 20 mm curvature.

  • PDF

Genotoxic Evaluation of Surfactin C in Chinese Hamster Lung Cell Line

  • Lim, Jong-Hwan;Song, In-Bae;Park, Byung-Kwon;Kim, Myoung-Seok;Hwang, Youn-Hwan;Yun, Hyo-In
    • Toxicological Research
    • /
    • v.25 no.1
    • /
    • pp.47-50
    • /
    • 2009
  • To investigate the mutation inducibility of surfactin C, we performed the chromosome aberration assay with Chinese hamster lung cells in vitro. The colorimetric MTT screening assay was carried out to determine the cytotoxicity index ($IC_{50}$) of surfactin C. The $IC_{50}$ value was $125{\mu}g/ml$. For the chromosome aberration test of surfactin C, the maximum concentration was employed as $125{\mu}g/ml$, followed by 62.5 and $31.25{\mu}g/ml$ for the lower concentrations, with or without metabolic activation (S9). Cyclophosphamide and mitomycin C were used as positive controls in the presence and absence of S9 metabolic activation, respectively. These results showed that surfactin C was not capable of inducing chromosome aberration, as measured by the chromosome aberration test using Chinese hamster lung cell line. There is no evidence for surfactin C to have a genotoxic potential.