• Title/Summary/Keyword: Journal evaluation

Search Result 68,570, Processing Time 0.11 seconds

An Evaluation of Various Synthetic Generations and Polycross Progenies in Winter Active Tall Fescue (Festuca arundinacea Schreb) - I. Summer Forage Phase (동기생육형(冬期生育型) 톨페스큐의 합성품종세대(合成品種世代)와 다계교배(多系交配) 후대검정(後代檢定)에 관(關)한 연구(硏究))

  • Kim, Dal Ung
    • Korean Journal of Agricultural Science
    • /
    • v.2 no.2
    • /
    • pp.341-356
    • /
    • 1975
  • This study was carried out to evaluate three winter active synthetic varieties in a succeeding generations of improvement and polycross progenies of seven genotypes selected at the cool and wet climate of the Western Oregon, in their performance of the polycross progeny test comparing with a control variety, high yielding 'Fawn', at Daejon, Korea. Various plant and leaf characteristics, especially related to photosynthesis, and forage production during the first summer after the establishment were examined. The important conclusions of this study are summarized as follows: 1. The differences of leaf fresh weight among groups and control exhibit genetic differences. The a verage of leaf fresh weight of polycross progeny group was the heaviest and those of winter active synthetic varieties in the succeeding generations of improvement was heavier than variety 'fawn'. Within polycross progeny group the genotypes exhibit genetic differences for leaf dry weight. 2. The leaf area exhibited genetic differences among groups and control. The average of winter active synthetic varieties in a succeeding generation was larger than variety 'Fawn'. Those oi the polycross progeny group was the largest among groups and control. 3. Differences of specific leaf weight(S. L. W.) among and within varieties, genotypes and control were not significant. Further investigation in this respect is necessary through the study of the diurnal change in S. L. W. 4. Differences of leaf width among groups and control exhibited genetic differences. The average leaf width of winter active varieties was larger than those of 'Fawn' variety. And those of polycross progenies of genotypes was the largest. 5. Plant height of 'fawn' variety in the first measurement was higher than those of winter active tall fescue varieties and genotypes. The deviation in plant height among polyeross progenies of seven genotypes gave a great deviation. The regrowth ability of plant height was not different suggesting that this characteristics was about the same among and within groups and control. 6. Plant width, spreading ability, improved through the succeeding generations of the improvement of the winter active synthetic varieties for the first measurement. Differences of plant width at the second measurement among genotypes within polycross progeny group were big enough to show the genetic difference. 7. Tiller number of the winter active synthetic varieties and the average of genotypes in polycross progeny was more than those of the control 'Fawn' in the first measurement. On the second measurement, the differences of tiller number appeared among three synthetic varieties indicating improvement, and there were genetic differences among seven genotypes in polycross progeny test. 8. Forage yield on the first cutting showed a considerble improvement of forage yield in the more advanced generation of synthetic varieties and genetic differences among seven genotypes in the polycross progeny test. The average of polycross progeny group was higher than those of the control or three winter active varieties. It was suggested that we could make a further improvement for the forage yield. 9. The regrowth ability of these winter active varieties and genotypes was about the same capacity at least on the measurement of the regrowth in forage yield and plant height during summer. 10. On the whole, the averages of the polycross progeny group was in the highest value and those of synthetic varieties were higher than the control variety, 'Fawn', for the most characteristics except S. L. W. and the plant height on the first measurement even though the differences were not always significant. And there were genetic differences among seven gentypes in their performance of the polycross progeny. 11. Although it was not always sgnificant, the most advanced winter active variety, '1002', had in the highest value for all plant characteristics and forage yield measurements than the other two varieties, '1001'. 12. The results of the association study among various characteristics were quite agreeable and would be useful in the selection of desirable genotypes for the development of a better variety.

  • PDF

The Developmental Effects of Radiation on ICR Mouse Embryos in Preimplantation Stage (착상전기(着床前期)에 있어서 ICR Mouse의 태아(胎兒)에 대한 방사선(放射線) 개체(個體) Level 영향(影響)의 연구(硏究))

  • Gu, Yeun-Hwa
    • Journal of Radiation Protection and Research
    • /
    • v.21 no.4
    • /
    • pp.273-284
    • /
    • 1996
  • Embryos and fetuses are more sensitive to various environmental agents than are adults or children. The biological effects such as intrauterine death and malformation are closely connected with prenatal exposure very various agents. The sensitivity of these embryonic/fetal effects depends on the stage of pregnancy. From the viewpoint of fetal development, embryonic and fetal stages can be divided into three stages : Preimplantation, organogenetic and fetal. Each stage corresponds to 0 to 4.5days, 4.5 to 13.5days, and 13.5days of gestation in mice, respectively. Many studies on the biologcal effects of mice irradiated by ${\gamma}-rays$ at various stages during organogenesis and fetal period have been performed. Based on these results, the dose-effect and dose-response relationships in malformations, intrauterine death, or retardation of the physical growth have been practically modeled by the ICRP(International Commission on Radiological Protection) and other international bodies for radiation protection. Many experimental studies on mice have made it clear that mice embryos in the preimplantation period have a higher sensitivity to radiation for lethal effects than the embryos/fetuses on other prenatal periods. However, no eratogenic effects of radiation at preimplantation stages of mice have been described in many textbooks. It has been believed that 'all or none action results' for radiation of mice during the preimplantation period were applied. The teratogenic and lethal effects during the preimplantation stage are one of the most important problems from the viewpoint of radiological protection, since the preimplantation stage is the period when the pregnancy itself is not noticed by a pregnant woman. There are many physical or chemical agents which affect embryos/fetuses in the environment. It is assumed that each agents indirectly effects a human. Then, a safety criterion on each agent is determined independently. The pregnant ICR mice on 2, 48, 72 or 96 hours post-conception (hpc), at which are preimplantation stage of embryos, were irradiated whole body Cesium-gamma radiation at doses of 0.1, 0.25, 0.5, 1.5, and 2.5 Gy with dose rate of 0.2 Gy/min. In the embryos from the fetuses from the mice irradiated at various period in preimplantation, embryonic/fetal mortalities, incidence of external gross malformation, fetal body weight and sex ratio were observed at day 18 of gestation. The sensitivity of embryonic mortalities in the mice irradiated at the stage of preimplantation were higher than those in the mice irradiated at the stage of organogenesis. And the more sensitive periods of preimplantation stage for embryonic death were 2 and 48 hpc, at which embryos were one cell and 4 to 7 cell stage, respectively. Many types of the external gross malformations such as exencephaly, cleft palate and anophthalmia were observed in the fetuses from the mice irradiated at 2, 72 and 96 hpc. However, no malformations were observed in the mice irradiated at 48 hpc, at which stage the embryos were about 6 cell stage precompacted embryos. So far, it is believed that the embryos on preimplantation stage are not susceptible to teratogens such as radiation and chemical agents. In this study, the sensitivity for external malformations in the fetuses from the mice irradiated at preimplantation were higher than those in the fetuses on stage of organogenesis.

  • PDF

The Evaluation of Radiation Dose to Embryo/Fetus and the Design of Shielding in the Treatment of Brain Tumors (임산부의 전뇌 방사선 치료에 있어서의 태아의 방사선량 측정 및 차폐 구조의 설계)

  • Cho, Woong;Huh, Soon-Nyung;Chie, Eui-Kyu;Ha, Sung-Whan;Park, Yang-Gyun;Park, Jong-Min;Park, Suk-Won
    • Journal of Radiation Protection and Research
    • /
    • v.31 no.4
    • /
    • pp.203-210
    • /
    • 2006
  • Purpose : To estimate the dose to the embryo/fetus of a pregnant patient with brain tumors, and to design an shielding device to keep the embryo/fetus dose under acceptable levels Materials and Methods : A shielding wall with the dimension of 1.55 m height, 0.9 m width, and 30 m thickness is fabricated with 4 trolleys under the wall. It is placed between a Patient and the treatment head of a linear accelerator to attenuate the leakage radiation effectively from the treatment head, and is placed 1 cm below the lower margin of the treatment field in order to minimize the dose to a patient from the treatment head. An anti-patient scattering neck supporters with 2 cm thick Cerrobend metal is designed to minimize the scattered radiation from the treatment fields, and it is divided into 2 section. They are installed around the patient neck by attach from right and left sides. A shielding bridge for anti-room scattered radiation is utilized to place 2 sheets of 3 mm lead plates above the abdomen to setup three detectors under the lead sheets. Humanoid phantom is irradiated with the same treatment parameters, and with and without shielding devices using TLD, and ionization chambers with and without a build-up cap. Results : The dose to the embryo/fetus without shielding was 3.20, 3.21, 1.44, 0.90 cGy at off-field distances of 30, 40, 50, and 60 cm. With shielding, the dose to embryo/fetus was reduced to 0.88, 0.60, 0.35, 0.25 cGy, and the ratio of the shielding effect varied from 70% to 80%. TLD results were 1.8, 1.2, 0.8, 1.2, and 0.8 cGy. The dose measured by the survey meter was 10.9 mR/h at the patient's surface of abdomen. The dose to the embryo/fetus was estimated to be about 1 cGy during the entire treatment. Conclusion : According to the AAPM Report No 50 regarding the dose limit of the embryo/fetus during the pregnancy, the dose to the embryo/fetus with little risk is less than 5 cGy. Our measurements satisfy the recommended values. Our shielding technique was proven to be acceptable.

COMPLIANCE STUDY OF METHYLPHENIDATE IR IN THE TREATMENT OF ADHD (주의력결핍과잉행동장애 치료 약물 Methylphenidate IR의 순응도 연구)

  • Hwang, Jun-Wan;Cho, Soo-Churl;Kim, Boong-Nyun
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.15 no.2
    • /
    • pp.160-167
    • /
    • 2004
  • Objectives : There have been very few studies on the compliance of methylphenidate-immediate releasing form(MPH-IR), which is the most frequently used drug in Korea, in Attention Deficit Hyperactivity Disorder(ADHD). This study was conducted to investigate the compliance rate and the related factors in the one year pharmacotherapy process via OPD for children with ADHD. Method : Total 100 ADHD patients were selected randomly among patients who have been treated with MPH-IR from September in 2002 to December in 2002. All the selected patients were diagnosed with DSM-IV-ADHD criteria and fulfilled the inclusion criteria. In March, 2003(at the time of 6 month treatment), all the patients and parents received the questionnaire for the compliance and satisfaction for MPH-IR treatment. In October 2003(at time of 1 year treatment), we, investigators evaluated the socio-demographic variables, developmental data, medical data, family data, comorbid disorders, treatment variables, and compliance rate. Through these very comprehensive data, The compliance rate at the time of mean 1 year treatment and the related factors were investigated. Result : 1) In the questionnaire for compliance and satisfaction for MPND treatment, the 60% of respondents(parents) reported more than moderate degree of satisfaction in the effectiveness of MPND. Their compliance rate for the morning prescription was 81%, but the rate of afternoon prescription was 43%. 2) In the evaluation at the time of 1 year treatment(October 2003), the 38% of parents were dropped out from the OPD treatment. The mean compliance rate for the 1 year treatment was 62%. the 38% of parents were dropped out from the OPD treatment. The mean compliance rate for the 1year treatment was 62%. 3) Compared with the noncompliant group(drop-out group), compliant group showed higher total, verbal and performance IQ scores. In the treatment variables, higher reposponder rate(clinician rating), higher medication dosage and more compliance rate in afternoon prescription were found in the compliant group compared with the noncompliant group. There were no statistical differences in the demographic variables(age, sex, SES, parental education level), medical data, developmental profiles and academic function. Conclusion : To our knowledge, this is the first report about the compliance rate of the MPH-IR treatment for the children with ADHD. The compliance rate at the time of mean 1year treatment was 62%, which was comparable with other studies performed in foreign countries, especially States. In this study, the compliance related factors were IQ score, clinical treatment response, dosage of MPH-IR, and early compliance for the afternoon prescription. These results suggest that clinician plan the strategies for the promotion of the early compliance for the after prescription and enhancement of overall treatment response.

  • PDF

Effect of Experimental Muscle Fatigue on Muscle Pain and Occlusal Pattern (실험적으로 유발되는 근피로가 근통증 및 교합양상에 미치는 영향)

  • Kim, Jae-Chang;Lim, Hyun-Dae;Kang, Jin-Kyu;Lee, You-Mee
    • Journal of Oral Medicine and Pain
    • /
    • v.33 no.3
    • /
    • pp.279-294
    • /
    • 2008
  • This study aimed to make an analysis of the occlusion in the state of muscle fatigue produced by excessive mouth opening and clenching during the dental treatment to control the dental pain and to evaluate the sensory nerve in the muscle pain state. Most of the reasons why patients visit the dental office result in pain-either conceivably the dental origin pain or the non-dental origin pain. The dental offices have many therapeutic actions to produce the masticatory muscle fatigue for the treatment. Dental treatment with long minutes of mouth opening can cause some headaches, masticatory muscle pain and mouth opening difficulties. Patients with mastication problems who visits a dental office to alleviate pain run against another unexpected pain with other aspects. This study uses T-scan II system(Tekscan Co., USA) for the evaluation on the occlusal pattern in the experimental muscle fatigue after clenching, opening the mouth excessively and chewing gum. The occlusal contact pattern is analyzed by the contact timing, namely first, intercuspal, maximum and end point of contact. This inspection was performed at frequencies of 2000Hz, 250 Hz and 5 Hz before and after each experimental muscle pain was produced to 24 subjects who had normal occlusion without the orthodontic treatment or a wide range of the prosthesis by using $neurometer^{\circledR}$ CPT/C(Neurotron, Inc. Baltimore, Maryland, USA). The measuring sites were mandibular nerve experimental muscle fatigue respectively. This study could obtain the following results after the assessment of occlusion and sensory nerve of the experimental muscle fatigue. 1. There were the fastest expression after the excessive mouth opening in muscle fatigue and after tooth clenching in muscle pain. In the visual analog scale that records the subjective level, there was the highest scale after the clenching in the muscle fatigue in jumping off the point of pain. 2. Tooth contact time, contact force, relative contact force on the point of the first contact had no difference, and there were decreases in the contact force after the excessive mouth opening on intercuspal position point, after the excessive mouth opening and the gum chewing on the point of the maximum, and in the contact time after all the experimental muscle fatigue state on the point of the end contact. 3. There was no statistic significance in the current perception threshold before and after the experimental muscle fatigue. 4. There was no significant difference in the contact number, the maximal contact number on the point of the first contact, and the contact number after the mouth opening and gum chewing on the point of the intercuspal position and the contact number after the experimental muscle fatigue on the maximum point, and showed significant decreases. In conclusion, it was found that the occlusal pattern can cause the changes on the case of the clinical muscle weakness by intra-external oral events. It was important that the sedulous attention to details is required during dental treatment in case of excessive mouth opening, mastication and clenching.

Evaluation of the Fruit Quality Indices during Maturation and Ripening and the Influence of Short-term Temperature Management on Shelf-life during Simulated Exportation in 'Changjo' Pears (Pyrus pyrifolia Nakai) (배 신품종 '창조'의 성숙 중 품질 요인 변화 및 수송온도 환경에 따른 반응성)

  • Lee, Ug-Yong;Choi, Jin-Ho;Ahn, Young-Jik;Chun, Jong-Pil
    • Journal of Bio-Environment Control
    • /
    • v.26 no.4
    • /
    • pp.378-385
    • /
    • 2017
  • In this study, we evaluated the changes of fruit quality indices during fruit development and ripening in Korean new pear cultivar 'Changjo', developed from a cross between 'Tama' and '81-1-27' ('Danbae' ${\times}$ 'Okusankichi') in 1995 and named in 2009, to determine appropriate harvest time and to enhance the market quality and broaden the cultivation area. The fruits of 'Changjo' pears harvested from 132 days after full bloom (DAFB) to 160 DAFB. Fruit growth and quality indices were monitored at 1 week interval by measuring fruit weight, length, diameter, firmness, and taste related quality indices. The calculated fruit fresh weight increased continuously with fruit development and reached to an average of 594g on Sep. 20 (160 DAFB). The ratio of length to diameter declines as fruit maturation progress, resulting in 0.898 for ripe fruit stage as a round oblate shape. Flesh firmness of 'Changjo' pears showed over 30N until 153 DAFB and then decreased abruptly with fruit ripening, reaching a final level of about 26.44N on 160 DAFB. Starch content of fruit sap was also decreased abruptly after 146 DAFB which decreased almost half of the fruits harvested at 139 DAFB. In parallel with the decrease of flesh firmness, ethanol insoluble solids (EIS) content decreased sharply with fruit ripens, only 50% of EIS was detected on the fruits harvested on 160 DAFB when compared to that of the fruits harvested on 139 DAFB (Aug. 30). The maximum value of soluble solids contents was observed in the fruits harvested on 153 DAFB, resulting in $14.2^{\circ}Brix$. The changes of skin color difference $a^*$ which means loss of green color occurred only after 139 DAFB, coincide with the decrease of SPAD value of the fruit skin. The sugars of the 80% ethanol soluble fraction consisted mainly of fructose, sorbitol, glucose and sucrose, also increased during maturation and ripening. Fructose and sucrose contents were larger than those of glucose and sorbitol in flesh tissues. These results were explained that stored starch is converted to soluble sugars during fruit maturation, mainly in fructose and sucrose increasing the sweetness of this cultivar. Total polyphenols were increased up to middle of fruit maturation (146 DAFB) and then decreased continuously until the end of fruit maturation. Consequently, our results suggested that the commercial harvest time of 'Changjo' pears should not be passed 153 DAFB and late harvest of this cultivar would not good for quality maintenance during shelf-life. As a result of the post-harvest low-temperature acclimation experiment during the short-term transportation period, fruits harvested at 146 DAFB tended to maintain higher firmness after 14 days of simulated marketing at $25^{\circ}C$ compared to fruits harvested at 153 DAFB regardless of temperature set. And, the slower the rate of decrease to the final transport temperature of $5^{\circ}C$, the higher the incidence of internal browning and ethylene production. Therefore, in order to suppress the physiological disorder and to maintain the fruit quality when exporting to Southeast Asia in the 'Chanjo' pears, it is desirable to lower the temperature of the fruits within a short time after harvest and to set the harvest time before 146 days after full bloom.

The study of MDCT of Radiation dose in the department of Radiology of general hospitals in the local area (일 지역 종합병원 영상의학과 MDCT선량에 대한 연구)

  • Shin, Jung-Sub
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.4
    • /
    • pp.281-290
    • /
    • 2012
  • The difference of radiation dose of MDCT due to different protocols between hospitals was analyzed by CTDI, DLP, the number of Slice and the number of DLP/Slice in 30 cases of the head, the abdomen and the chest that have 10 cases each from MDCT examination of the department of diagnostic imaging of three general hospitals in Gyeongsangbuk-do. The difference of image quality, CTDI, DLP, radiation dose in the eye and radiation dose in thyroid was analyzed after both helical scan and normal scan for head CT were performed because a protocol of head CT is relatively simple and head CT is the most frequent case. Head CT was significantly higher in two-thirds of hospitals compared to A hospital that does not exceed a CTDI diagnostic reference level (IAEA 50mGy, Korea 60mGy) (p<0.001). DLP was higher in one-third of hospitals than a diagnostic reference level of IAEA 1,050mGy.cm and Korea 1,000mGy.cm and two-thirds exceeded the recommendation of Korea and those were significantly higher than A hospital that does not exceed a diagnostic reference level (p<0.001). Abdomen CT showed 119mGy that was higher than a diagnostic reference level of IAEA 25mGy and Korea 20mGy in one-third. DLP in all hospitals was higher that Korea recommendation of 700mGy.cm. Among target hospitals, C hospital showed high radiation dose in all tests because MPR and 3D were of great importance due to low pitch and high Tube Curren. To analyze the difference of radiation dose by scan methods, normal scan and helical scan for head CT of the same patient were performed. In the result, CTDI and DLP of helical CT were higher 63.4% and 93.7% than normal scan (p<0.05, p<0.01). However, normal scan of radiation dose in thyroid was higher 87.26% (p<0.01). Beam of helical CT looked like a bell in the deep part and the marginal part so thyroid was exposed with low radiation dose deviated from central beam. In addition, helical scan used Gantry angle perpendicularly and normal scan used it parallel to the orbitomeatal line. Therefore, radiation dose in thyroid decreased in helical scan. However, a protocol in this study showed higher radiation dose than diagnostic reference level of KFDA. To obey the recommendation of KFDA, low Tube Curren and high pitch were demanded. In this study, the difference of image quality between normal scan and helical scan was not significant. Therefore, a standardized protocol of normal scan was generally used and protective gear for thyroid was needed except a special case. We studied a part of CT cases in the local area. Therefore, the result could not represent the entire cases. However, we confirmed that patient's radiation dose in some cases exceeded the recommendation and the deviation between hospitals was observed. To improve this issue, doctors of diagnostic imaging or technologists of radiology should perform CT by the optimized protocol to decrease a level of CT radiation and also reveal radiation dose for the right to know of patients. However, they had little understanding of the situation. Therefore, the effort of relevant agencies with education program for CT radiation dose, release of radiation dose from CT examination and addition of radiation dose control and open CT contents into evaluation for hospital services and certification, and also the effort of health professionals with the best protocol to realize optimized CT examination.

The Alignment Evaluation for Patient Positioning System(PPS) of Gamma Knife PerfexionTM (감마나이프 퍼펙션의 자동환자이송장치에 대한 정렬됨 평가)

  • Jin, Seong Jin;Kim, Gyeong Rip;Hur, Beong Ik
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.3
    • /
    • pp.203-209
    • /
    • 2020
  • The purpose of this study is to assess the mechanical stability and alignment of the patient positioning system (PPS) of Leksell Gamma Knife Perfexion(LGK PFX). The alignment of the PPS of the LGK PFX was evaluated through measurements of the deviation of the coincidence of the Radiological Focus Point(RFP) and the PPS Calibration Center Point(CCP) applying different weights on the couch(0, 50, 60, 70, 80, and 90 kg). In measurements, a service diode test tool with three diode detectors being used biannually at the time of the routine preventive maintenance was used. The test conducted with varying weights on the PPS using the service diode test tool measured the radial deviations for all three collimators 4, 8, and 16 mm and also for three different positions of the PPS. In order to evaluate the alignment of the PPS, the radial deviations of the correspondence of the radiation focus and the LGK calibration center point of multiple beams were averaged using the calibrated service diode test tool at three university hospitals in Busan and Gyeongnam. Looking at the center diode for all collimators 4, 8, and 16 mm without weight on the PPS, and examining the short and long diodes for the 4 mm collimator, the means of the validation difference, i.e., the radial deviation for the setting of 4, 8, and 16 mm collimators for the center diode were respectively measured to 0.058 ± 0.023, 0.079 ± 0.023, and 0.097 ± 0.049 mm, and when the 4 mm collimator was applied to the center diode, the short diode, and the long diode, the average of the radial deviation was respectively 0.058 ± 0.023, 0.078 ± 0.01 and 0.070 ± 0.023 mm. The average of the radial deviations when irradiating 8 and 16 mm collimators on short and long diodes without weight are measured to 0.07 ± 0.003(8 mm sd), 0.153 ± 0.002 mm(16 mm sd) and 0.031 ± 0.014(8 mm ld), 0.175 ± 0.01 mm(16 mm ld) respectively. When various weights of 50 to 90 kg are placed on the PPS, the average of radial deviation when irradiated to the center diode for 4, 8, and 16 mm is 0.061 ± 0.041 to 0.075 ± 0.015, 0.023 ± 0.004 to 0.034 ± 0.003, and 0.158 ± 0.08 to 0.17 ± 0.043 mm, respectively. In addition, in the same situation, when the short diode for 4, 8, and 16 mm was irradiated, the averages of radial deviations were 0.063 ± 0.024 to 0.07 ± 0.017, 0.037 ± 0.006 to 0.059 ± 0.001, and 0.154 ± 0.03 to 0.165 ± 0.07 mm, respectively. In addition, when irradiated on long diode for 4, 8, and 16 mm, the averages of radial deviations were measured to be 0.102 ± 0.029 to 0.124 ± 0.036, 0.035 ± 0.004 to 0.054 ± 0.02, and 0.183 ± 0.092 to 0.202 ± 0.012 mm, respectively. It was confirmed that all the verification results performed were in accordance with the manufacturer's allowable deviation criteria. It was found that weight dependence was negligible as a result of measuring the alignment according to various weights placed on the PPS that mimics the actual treatment environment. In particular, no further adjustment or recalibration of the PPS was required during the verification. It has been confirmed that the verification test of the PPS according to various weights is suitable for normal Quality Assurance of LGK PFX.

Relation between Health Status and Intake of Soy Isoflavone among Adult Women in Seoul (서울 거주 성인 여성의 대두 이소플라본 섭취와 건강과의 관련성)

  • Lee, Min-June;Sohn, Chun-Young;Park, Ok-Jin
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.20 no.2
    • /
    • pp.218-230
    • /
    • 2010
  • This study was conducted to survey isoflavone intake among adult women in menopause with diseases such as metabolic syndrome and osteoporosis and to analyze the relationship between each of these chronic diseases followed by isoflavone intake and the related health risk index. The average age of the subjects was 49.97 years old, while that of the pre-menopausal subjects was 45.14 years, and the post-menopausal subjects was 55.99 years. The average body mass index (BMI), waist-hip circumference, body fat percentage, blood pressure, blood sugar and blood lipid content of the post-menopausal subjects were higher in significant difference than those of the pre-menopausal subjects. The bone density of the hip and spine in post-menopausal subjects was lower in significant difference than that of the pre-menopausal subjects. After menopause, the subjects had a lower ratio of individuals at risk of anemia when compared with the subjects before menopause, but had higher health risk ratio related to each type of chronic disease, including obesity, hypertension, high cholesterol and osteoporosis than the subjects before menopause. The intake frequency of each soybean food was similar among subjects before/after menopause. The most common soybean based foods consumed by the subjects were soybean, soybean curd and soybean paste. The average daily intake level of isoflavone among subjects before menopause was 25.48 mg, while that of subjects after menopause was 32.25 mg. Evaluation of the distribution of the isoflavone level revealed that the pre-menopausal subjects consumed 3.29~78.36 mg and the post-menopausal subjects consumed 3.18~116.59 mg. The intake level by each individual varied greatly. The pre-menopausal subjects had a low BMI index and systolic blood pressure as much as their isoflavone intake level was high. Additionally, the post-menopausal subjects had a low menarche age and high menopause age when their isoflavone intake level was high, the BMI index and waist-hip circumference ratio was highest among individuals with lowest isoflavone intake level. This study showed that there was a possible relationship between soybean isoflavone intake and health problems such as obesity, high cholesterol, and osteoporosis in women after menopause with diseases such as metabolic syndrome and osteoporosis, even if this relationship was not great.

Major Characteristics Related to Eating Quality in Waxy Corn Hybrids (찰옥수수 교잡종의 식미관련 주요 특성)

  • Jung Tae wook;Kim Sun Lim;Moon Hyeon Gui;Son Beom Young;Kim Si Ju;Kim Soon Kwon
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.50 no.spc1
    • /
    • pp.152-160
    • /
    • 2005
  • This study was carried out to investigate selectable criteria in evaluating waxy corn $F_1$ hybrids for developing good eating quality waxy corn variety. The physicochemical property analysis of 6 waxy corn $F_1$ hybrids - Chalok1, Chalok2, Heugjeomchal, Yeonnongl, Chalok4, and Suwon45- showed a range of $11.2\~13.1\%$ for crude protein, $5.1\~6.0\%$ for crude fat, $91.8\~92.6\%$ for amylopectin, and $4.5\~6.6\%$ for free sugar content. The pericarp thickness which is one of the most important characteristics related to tenderness in waxy corn was ranged $34\~47{\mu}m$ in 4 waxy corn hybrids - Yeonnongl, Chalok4, Suwon45, and Heugjeomchal. On the other hand, it was ranged $64\~81{\mu}m$ in Chalok1 and Chalok2. The amylogram analysis by rapid visco analyzer showed that in fresh waxy corn hybrid (DAP25), all amylogram properties except setback were higher in Yeonnongl, Chalok4, and Suwon45 compared to those of Chalokl, Chnlok2, and Heugjeomchal. However, in matured waxy corn hybyids (DAP45), the result was the opposite - the amylogram properties were higher in Chalokl, Chalok2, and Heugjeomchal than those of Yeonnongl, Chalok4, and Suwon45. The texture analysis showed that gumminess, chewiness, and hardness increased dramatically with the time after the cooking in Chalokl and Beugjeomchal. On the other hand, these above pyoperties did not change as rapidly with the time in Yeonnongl, Chalok4, and Suwon45. Gumminess, chewiness, and hardness did not increase much within 6 hours after steamingr but increased significantly 32 hours after steaming. Therefore, we have reached a conclusion that texture analysis of cooked waxy corn should be carried out 6 hours after steaming. In the sensory evaluation, Yeonnongl, Chalok4, and Suwon45 revealed higher palatability -6.8, 7.1, and 6.9 respectively - than. that of Chnlokl, Chalok2, and Heugjeomchal. The palatability analysis of 6 waxy corn hybrids showed palatability positively correlating with free sugar content,100-kernel weight, kernel length, kernet width, and consistency, but negatively correlating with pericarp thickness, hardness, gumminess, and chewiness.