• Title/Summary/Keyword: Journal evaluation

Search Result 68,741, Processing Time 0.106 seconds

The impacts of the experince of donation for education to improve the teaching efficacy of pre-technology teacher with Invent touring activity (발명체험 교육기부활동이 예비기술교사의 교수 효능감에 미치는 영향)

  • Choi, Yu-Hyun;Lim, Yun-Jin;Lee, Eun-Sang;Lee, Dong-Won
    • 대한공업교육학회지
    • /
    • v.38 no.2
    • /
    • pp.156-175
    • /
    • 2013
  • The purpose of this study was to verify that the impacts of experience of donation for education to improve the teaching efficacy of pre-technology teacher. The Invention experience of donation for education was performed with Invent-touring sponsored by Chunnam National University Invention Education Center for Teachers and was included by development of creative problem solving program, program execution and evaluation. Research participants were Technology education Majors and minors 20 students. The active locations were D children community center, K alternative school, D Elementary School and D middle school. For the study, various literature researches were reviewed intensively about donation for education and teaching efficacy. The instrument for the study was the modified STEBI(Science Teaching Efficacy Beliefs Instrument) for technology education by 3 experts. This study was designed by single group pre and post test design (One-Group Pretest-Posttest Design) and was conducted by the pre-test and post-test. Check the reliability of the tool was conducted with Cronbach ${\alpha}$ coefficient analysis, pre-test 0.840, post-test 0.746. The analysis of data from the 5% significance level, paired sample t-test was performed using the SPSS 19.0 statistical tool. The results were as follows: 1. Teaching efficacy of pre-technology teachers who participated in the invention experience for educational donation technology has improved. 72. The qualitative study was performed by the interviews with students who participated in. Humanism was positively change and learning opportunity was provided to develop the competence of technology education teacher. Based upon the conclusion of this study, the donation activity for invention education need to use learning strategies for pre-technology teacher to improve teaching efficacy.

An Analysis of Proper Curriculum Organization Plan for Elementary and Secondary Invention/Intellectual Property Education (초·중등 발명·지식재산 교육과정의 적정 편성 방안 연구)

  • Lee, Kyu-Nyo;Lee, Byung-Wook
    • 대한공업교육학회지
    • /
    • v.42 no.1
    • /
    • pp.106-124
    • /
    • 2017
  • This study used the secondary Delphi method for experts, in order to propse a proper formation plan for the goal and curriculum of elementary and secondary invention/intellection property education. Its results are as following; First, the key objective of invention/intellectual property education for each school level is evaluated as appropriate. With regard to the key objective, elementary schools are aiming at 'fostering awareness and attitude for invention'(M=4.5), middle schools, 'understanding of invention process and method'(M=4.2), general high schools, 'application and evaluation of invention method'(M=4.1), and specialized high schools, 'understanding and application of Employee Invention'(M=4.6). The objective and goal of education for each school level are also evaluated as appropriate. Second, although the proper formation plans for a key learning element of elementary and secondary invention/intellectual property education were almost identical to an actual formation of preceding literature, overall change is required for the formation balance of each learning element, according to the objective and goal of school-leveled invention/intellectual property education. An appropriate formation shall be focusing on basic learning elements (A, B, C, D, E, and F) for elementary and middle schools(73.2%, 65.1%), lowering somewhat the former elements and increasing expanded learning elements for high schools(51.0%), which are connected to the invention, course(H), and patent application(K). Third, elementary and secondary invention/intellectual property education system should be oriented to its objective and goal. In order to reach this, an appropriate formation plan should be made for each school level, based on the principle of Tyler's learning organization, such as continuity, sequence and integration, which are key learning element. Specialized high schools, in particular, need to be differentiated from general ones, as well as elementary and middle schools. Additionally, for understanding and applying an employee invention, invention/intellectual property education system needs to be established in the phase of secondary occupational education.

Study on Tumor Control Probability and Normal Tissue Complication Probability in 3D Conformal Radiotherapy (방사선 입체조형치료에 대한 종양치유확율과 정상조직손상확율에 관한 연구)

  • 추성실
    • Progress in Medical Physics
    • /
    • v.9 no.4
    • /
    • pp.227-245
    • /
    • 1998
  • A most appropriate model of 3-D conformal radiotherapy has been induced by clinical evaluation and animal study, and therapeutic gains were evaluated by numerical equation of tumor control probability(TCP) and normal tissue complication probability (NTCP). The radiation dose to the tumor and the adjacent normal organs was accurately evaluated and compared using the dose volume histogram(DVH). The TCP and NTCP was derived from the distribution of given dosage and irradiated volume, and these numbers were used as the biological index for the assessment of the treatment effects. Ten patients with liver disease have been evaluated and 3 dogs were sacrificed for this study. Based on the 3-D images of the tumor and adjacent organs, the optimum radiation dose and the projection direction which could maximize the radiation effect while minimizing the effects to the adjacent organs could be decided. 3). The most effective collimation for the normal adjacent organs was made through the beams eye view with the use of multileaf collimator. When the dose was increased from 50Gy to 70Gy, the TCP for the conventional 2-port radiation and the 5-port multidimensional therapy was 0.982 and 0.995 respectively, while the NTCP was 0.725 and 0.142 respectively, suggesting that the 3-D conformal radiotherapy might be the appropriate therapy to apply sufficient radiation dose to the tumor while minimizing the damages to the normal areas of the liver. Positive correlation was observed between the NTCP and the actual complication of the normal liver in the animal study. The present study suggest that the use of 3-D conformal radiotherapy and the application of the mathematical models of TCP and NTCP may provide the improvements in the treatment of hepatoma with enhanced results.

  • PDF

Error Analysis of Delivered Dose Reconstruction Using Cone-beam CT and MLC Log Data (콘빔 CT 및 MLC 로그데이터를 이용한 전달 선량 재구성 시 오차 분석)

  • Cheong, Kwang-Ho;Park, So-Ah;Kang, Sei-Kwon;Hwang, Tae-Jin;Lee, Me-Yeon;Kim, Kyoung-Joo;Bae, Hoon-Sik;Oh, Do-Hoon
    • Progress in Medical Physics
    • /
    • v.21 no.4
    • /
    • pp.332-339
    • /
    • 2010
  • We aimed to setup an adaptive radiation therapy platform using cone-beam CT (CBCT) and multileaf collimator (MLC) log data and also intended to analyze a trend of dose calculation errors during the procedure based on a phantom study. We took CT and CBCT images of Catphan-600 (The Phantom Laboratory, USA) phantom, and made a simple step-and-shoot intensity-modulated radiation therapy (IMRT) plan based on the CT. Original plan doses were recalculated based on the CT ($CT_{plan}$) and the CBCT ($CBCT_{plan}$). Delivered monitor unit weights and leaves-positions during beam delivery for each MLC segment were extracted from the MLC log data then we reconstructed delivered doses based on the CT ($CT_{recon}$) and CBCT ($CBCT_{recon}$) respectively using the extracted information. Dose calculation errors were evaluated by two-dimensional dose discrepancies ($CT_{plan}$ was the benchmark), gamma index and dose-volume histograms (DVHs). From the dose differences and DVHs, it was estimated that the delivered dose was slightly greater than the planned dose; however, it was insignificant. Gamma index result showed that dose calculation error on CBCT using planned or reconstructed data were relatively greater than CT based calculation. In addition, there were significant discrepancies on the edge of each beam while those were less than errors due to inconsistency of CT and CBCT. $CBCT_{recon}$ showed coupled effects of above two kinds of errors; however, total error was decreased even though overall uncertainty for the evaluation of delivered dose on the CBCT was increased. Therefore, it is necessary to evaluate dose calculation errors separately as a setup error, dose calculation error due to CBCT image quality and reconstructed dose error which is actually what we want to know.

Quantitative Evaluation of Gated Radiation Therapy Using Gamma Index Analysis (감마지표 분석을 통한 호흡연동방사선치료의 정량적 평가)

  • Ma, Sun Young;Choi, Ji Hoon;Jeung, Tae Sig;Lim, Sangwook
    • Progress in Medical Physics
    • /
    • v.24 no.3
    • /
    • pp.198-203
    • /
    • 2013
  • Generally, to evaluate gated radiation therapy, moving phantoms are used to simulate organ motion. Since the target moves in every direction, we need to take into account motion in each direction. This study proposes methods to evaluate gated radiation therapy using gamma index analysis and to visualize adequate gating window sizes according to motion ranges. The moving phantom was fabricated to simulate motion in the craniocaudal direction. This phantom consisted of a moving platform, the I'm MatriXX, and solid water phantoms. A 6 MV photon filed with a field size of $4{\times}4cm^2$ was delivered to the phantom using the gating system, while the phantom moved in the 1-, 2-, 3-, 4-, and 5-cm motion ranges. The gating windows were set at 40~60%, 30~40%, and 0~90%, respectively. The I'm MatriXX acquired the dose distributions for each scenario and the dose distributions were compared with a $4{\times}4cm^2$ static filed. The tolerance of the gamma index was set at 3%/3 mm. The greater the gating window, the lower the pass rate, and the greater the motion range, the lower the pass rate in this study. In case treatment without gated radiation therapy for the target with motion of 2 cm, the pass rate was less than 96%. But it was greater than 99% when gated radiation therapy was used. However gated radiation therapy was used for the target with motion greater than 4 cm, the pass rate could not be greater than 97% when gating window was set as 30~70%. But when the gating window set as 40~60%, the pass rate was greater than 99%.

Evaluation of White Matter Abnormality in Mild Alzheimer Disease and Mild Cognitive Impairment Using Diffusion Tensor Imaging: A Comparison of Tract-Based Spatial Statistics with Voxel-Based Morphometry (확산텐서영상을 이용한 경도의 알츠하이머병 환자와 경도인지장애 환자의 뇌 백질의 이상평가: Tract-Based Spatial Statistics와 화소기반 형태분석 방법의 비교)

  • Lim, Hyun-Kyung;Kim, Sang-Joon;Choi, Choong-Gon;Lee, Jae-Hong;Kim, Seong-Yoon;Kim, Heng-Jun J.;Kim, Nam-Kug;Jahng, Geon-Ho
    • Investigative Magnetic Resonance Imaging
    • /
    • v.16 no.2
    • /
    • pp.115-123
    • /
    • 2012
  • Purpose : To evaluate white matter abnormalities on diffusion tensor imaging (DTI) in patients with mild Alzheimer disease (AD) and mild cognitive impairment (MCI), using tract-based spatial statistics (TBSS) and voxel-based morphometry (VBM). Materials and Methods: DTI was performed in 21 patients with mild AD, in 13 with MCI and in 16 old healthy subjects. A fractional anisotropy (FA) map was generated for each participant and processed for voxel-based comparisons among the three groups using TBSS. For comparison, DTI data was processed using the VBM method, also. Results: TBSS showed that FA was significantly lower in the AD than in the old healthy group in the bilateral anterior and right posterior corona radiata, the posterior thalamic radiation, the right superior longitudinal fasciculus, the body of the corpus callosum, and the right precuneus gyrus. VBM identified additional areas of reduced FA, including both uncinates, the left parahippocampal white matter, and the right cingulum. There were no significant differences in FA between the AD and MCI groups, or between the MCI and old healthy groups. Conclusion: TBSS showed multifocal abnormalities in white matter integrity in patients with AD compared with old healthy group. VBM could detect more white matter lesions than TBSS, but with increased artifacts.

Quantitative Conductivity Estimation Error due to Statistical Noise in Complex $B_1{^+}$ Map (정량적 도전율측정의 오차와 $B_1{^+}$ map의 노이즈에 관한 분석)

  • Shin, Jaewook;Lee, Joonsung;Kim, Min-Oh;Choi, Narae;Seo, Jin Keun;Kim, Dong-Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.4
    • /
    • pp.303-313
    • /
    • 2014
  • Purpose : In-vivo conductivity reconstruction using transmit field ($B_1{^+}$) information of MRI was proposed. We assessed the accuracy of conductivity reconstruction in the presence of statistical noise in complex $B_1{^+}$ map and provided a parametric model of the conductivity-to-noise ratio value. Materials and Methods: The $B_1{^+}$ distribution was simulated for a cylindrical phantom model. By adding complex Gaussian noise to the simulated $B_1{^+}$ map, quantitative conductivity estimation error was evaluated. The quantitative evaluation process was repeated over several different parameters such as Larmor frequency, object radius and SNR of $B_1{^+}$ map. A parametric model for the conductivity-to-noise ratio was developed according to these various parameters. Results: According to the simulation results, conductivity estimation is more sensitive to statistical noise in $B_1{^+}$ phase than to noise in $B_1{^+}$ magnitude. The conductivity estimate of the object of interest does not depend on the external object surrounding it. The conductivity-to-noise ratio is proportional to the signal-to-noise ratio of the $B_1{^+}$ map, Larmor frequency, the conductivity value itself and the number of averaged pixels. To estimate accurate conductivity value of the targeted tissue, SNR of $B_1{^+}$ map and adequate filtering size have to be taken into account for conductivity reconstruction process. In addition, the simulation result was verified at 3T conventional MRI scanner. Conclusion: Through all these relationships, quantitative conductivity estimation error due to statistical noise in $B_1{^+}$ map is modeled. By using this model, further issues regarding filtering and reconstruction algorithms can be investigated for MREPT.

Preoperative Evaluation of Lower Rectal Cancer by Pelvic MR with and without Gel Filling (하부직장암 환자에서 초음파겔 삽입 전후의 골반 자기공명영상의 비교)

  • Kim, Dae Jung;Kim, Joo Hee;Lim, Joon Seok;Chung, Jae-Joon;Yu, Jeong-Sik;Kim, Myeong-Jin;Kim, Ki Whang
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.4
    • /
    • pp.323-331
    • /
    • 2014
  • Purpose : To assess the usefulness of rectal filling using ultrasonographic gel in patients with lower rectal cancer. Materials and Methods: Twenty five patients with lower rectal cancer were enrolled. High resolution pelvic MR was performed twice before and after gel filling. Independently and retrospectively, two radiologists reviewed each set of MR images using five-grade scales for sphincter involvement, CRM (circumferential resection margin) involvement and depiction of the tumor. Same two radiologists retrospectively performed consensus review of each set of MR images for tumor distance from the anal verge and T&N staging. Results: Tumor depiction scores from MR with gel filling were significantly higher than those of MR without distention (p<0.001). Compared to MR without distension, MR with gel filling had no significant differences in prediction of CRM or sphincter involvement (p>0.05). Distance from the anal verge was significantly different between MR with gel filling and rigid endoscopy ($6.8{\pm}1.6cm$ vs. $5.8{\pm}1.6cm$, p=0.001). There were no significant differences between pathological staging and MR staging with or without gel filling. Conclusion: MR with gel filling improved tumor depiction. And also MR with gel filling revealed same ability for the predictions of CRM or sphincter invasion in patients with lower rectal cancer, comparing with MR without gel filling.

Diastolic Function in Patients with Hypertrophic Cardiomyopathy: Evaluation Using the Phase-contrast MRI Measurement of Mitral Valve and Pulmonary Vein Flow Velocities (비대성심근증 환자의 이완기능평가: 승모판과 폐정맥 유속을 측정한 위상차 MRI의 이용)

  • Kim, Eun Young;Choe, Yeon Hyeon;Kim, Sung Mok;Lee, Sang-Chol;Chang, Sung-A;Oh, Jae K.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.4
    • /
    • pp.314-322
    • /
    • 2014
  • Purpose: Diastolic dysfunction is a common problem in patients with hypertrophic cardiomyopathy (HCM). The purpose of this study was to assess the role of MRI in the assessment of diastolic function using mitral valve and pulmonary vein flow velocities in HCM patients. Methods and Results: Phase-contrast MRI (mitral valve and pulmonary vein) and transthoracic echocardiography was successfully performed for 59 HCM patients (44 men and 15 women; mean age, 51 years). Forty-nine patients had a diastolic dysfunction; grade 1 (n = 20), grade 2 (n = 27), and grade 3 (n = 2) using echocardiography, and ten patients had normal diastolic function. The transmitral inflow parameters (E, A, and E/A ratios) obtained by MRI showed positive correlation with the same parameters measured by echocardiography (Pearson's r values were 0.47, 0.60, and 0.75 for E, A, E/A, respectively, all P < 0.001). With the flow information of the pulmonary vein from cardiac MRI, pseudo-normalized pattern (n = 8) could be distinguished from true normal filling pattern (n = 17), and the diastolic function grades by cardiac MRI showed moderate agreement with those of echocardiography (kappa value = 0.45, P < 0.001). Conclusions: Assessment of left ventricle diastolic function is feasible using phase-contrast MRI in HCM patients. Analysis of pulmonary vein flow velocity on MRI is useful for differentiating pseudo-normal from normal diastolic function in HCM patients.

Evaluation of Therapeutic Effects of Cognitive-Behavioral Therapy in Patients with Panic Disorder using Serial $^{99m}Tc-ECD$ Brain Perfusion (공황장애 환자에서 $^{99m}Tc-ECD$ 뇌관류 SPECT를 이용한 인지행동치료 효과 평가)

  • Kim, Jung-Hee;Song, Ho-Chun;Yang, Jong-Chul;Lee, Byeong-Il;Heo, Young-Jun;Bom, Hee-Seung;Park, Tae-Jin;Min, Jung-Joon
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.6
    • /
    • pp.302-308
    • /
    • 2006
  • Purpose: Although several neuroanatomical models of panic disorder have been proposed, little is known regarding the neurological mechanisms underlying cognitive-behavioral therapy (CBT) in patients with panic disorder. This study was performed to identify the brain structures that show changes of regnioal cerebral blood flow (rCBF) after CBT in patients with panic disorder. Materials and Methods: Seven patients who were diagnosed as panic disorder by DSM-IV were treated with CBT for 8 weeks and twelve healthy volunteers joined in this study. Serial $^{99m}Tc-ECD$ brain perfusion SPECT images were acquisited and PDSS-SR (Self-Report version of Panic Disorder Severity Scale) and ACQ (Agoraphobic Cognitive Question) scores were measured just before and after CBT in all patients. Data were analyzed using SPM2. Results: Subjective symptoms were improved, and PDSS-SR and ACQ scores were significantly reduced ($14.9{\pm}3.9\;vs.\;7.0{\pm}1.8$, p<0.05; $30.3{\pm}8.5\;vs.\;21.6{\pm}3.4$, p<0.05, respectively) after CBT in panic patients. Before CBT, a significant increase of rCBF was found in the cingulate gylus, thalamus, midbrain, both medial frontal and temporal lobes of the panic patients compared to the normal volunteers. After CBT, we observed a significant rCBF decrease in the left parahippocamus, right insula and cingulate gyrus, both frontal and temporal lobes, and a significant rCBF increase in both the occipital lobes, left insula, both frontal and left parietal lobes. Conclusion: These data suggested that CBT is effective for panic disorder and diminish the activity of the brain areas associated with fear in panic disorder.