• Title/Summary/Keyword: Joint stability

Search Result 883, Processing Time 0.031 seconds

The Fabrication and Characteristics of Small Disk-Type Ultrasonic Motor (소형 원판형 초음파 모터의 시작 및 특성)

  • Park, C.H.;Lee, J.S.;Jeong, S.H.;Chai, H.I.;Lee, K.W.;Kim, H.H.;Lim, K.J.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07d
    • /
    • pp.1720-1722
    • /
    • 1999
  • In this paper, we studied the properties of small-size disk-type ultrasonic motor using travelling wave for the application to the precise control robotic joint motor and fabricated it. The diameter of the ultrasonic motor fabricated was 13mm. Also, the piezoelectric vibrator was constructed by piezoelectric ceramic and elastic material. The piezoelectric ceramic was composed to PZ-PT-PMN which was shown the high electromechanical stability under high vibration level and stainless steel was used as the elastic material in which configuration was disk-type. To conform the capability of application to robotic motor, we measured the change of rotational speed according to applied voltage and applied frequency. As the results, the small-size disk-type ultrasonic motor was able to fabricate, and the revolution speed was 350 [rpm] when input voltage was 55 [Vrms] and applied frequency 160.4 [kHz] under pre-load.

  • PDF

Immediate Effect of Fabric Ankle-Foot Orthosis on Spatiotemporal Gait Parameters in Children With Spastic Cerebral Palsy (패브릭 발목 보조기가 경직성 뇌성마비 아동의 시공간적 보행 변수에 미치는 즉각적인 효과)

  • Sim, Yon-Ju;Lee, Dong-Ryul;Yi, Chung-Hwi
    • Physical Therapy Korea
    • /
    • v.21 no.1
    • /
    • pp.29-36
    • /
    • 2014
  • The purpose of this study was to investigate the immediate effect of fabric ankle-foot orthosis on spatiotemporal gait parameters, compared to a barefoot condition in children with spastic cerebral palsy. Eleven children with spastic cerebral palsy participated in this study. Spatiotemporal gait parameters were measured with the GAITRite system. Fabric ankle-foot orthosis significantly improved Timed Up and Go test time and gait velocity. There was no significant difference in cadence. The step time significantly improved in both the more and less affected foot compared to the barefoot condition. The step length of the affected foot also significantly improved, but there was no significant difference in the step length of the less affected foot. There was significant improvement in the stride length of both the affected and less affected foot, but no significant difference in single stance or double stance. The fabric ankle-foot orthosis could improve stability, and selective control of the joint and promote better walking in children with cerebral palsy. Consequently, the fabric ankle-foot orthosis might be an alternative assistive device for neurological populations as a primary role instead of the typical ankle-foot orthosis.

Design and Analysis of Above Knee Prosthetic Leg Using MR Damper (유동모드 MR 댐퍼가 구비된 대퇴의족의 설계 및 해석)

  • Park, Jinhyuk;Kang, Je-Won;Choi, Seung-Bok
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.26 no.2
    • /
    • pp.165-171
    • /
    • 2016
  • A prosthetic knee for above-knee (AK) amputee is categorized into passive and active type. The passive prosthetic knee is generally made by elastic material. Although AK amputee can easily walk by using passive prosthetic leg, knee joint motions are not similar to ordinary persons. The active prosthetic leg can control the knee angle owing to the actuator and microprocessor. However, the active type is not cost-effective and the stability may be lost due to the malfunction of sensors. In order to resolve these disadvantages of passive and active type, a semi-active prosthetic knee which can control the knee angle is proposed in this work. The proposed semi-active one requires a less input energy but provides active type performance. In order to achieve this goal, in this work, a semi-active prosthetic knee using magneto-rheological (MR) damper for AK amputees is designed. The MR damper can support the weight of body by using less energy than actuator of active prosthetic. It can control knee angle by inducing the magnetic field at the time of stance phase. This salient characteristic is evaluated and presented in this work.

Anatomical Reconstruction of the Lateral Ankle Ligaments using Semitendinosus (반건양근 건을 이용한 족관절 외측 인대의 해부학적 재건)

  • Lee, Woo-Chun
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.7 no.1
    • /
    • pp.19-23
    • /
    • 2008
  • Purpose: Several methods of anatomical reconstruction for chronic lateral ankle instability has been reported to avoid the problems of nonanatomical reconstruction. Precise reconstruction of the normal anatomy is essential to the restoration of normal joint mechanics and stability. The problem with anatomical reconstruction is that it is very difficult to reconstruct the normal anatomic course of the ligaments. We thought making one tunnel at the fibular attachment of anterior talofibular ligament and calcaneofibular ligament was more anatomical than making separate tunnels for each ligaments because the two ligaments are contiguous. In this article, the basis of anatomical reconstruction of the lateral ankle ligaments was reviewed and a technique of reconstruction using semitendinosus was introduced.

  • PDF

Development of the Hybrid Type Robot Using a Pneumatic Actuator For Physical Therapy Of Ankylosis (관절 경직 환자의 물리 치료를 위한 공압 구동형 하이브리드 로봇 개발)

  • 최현석;최철우;한창수;한정수
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.2
    • /
    • pp.127-132
    • /
    • 2003
  • In this paper. the pneumatic service robot with a hybrid type is developed. A pneumatic has the advantages of good compliance , high Payload-to-weight and payload-to-volume ratios. high speed and force capabilities. Using pneumatic actuators. which have low stiffness. the service robot can guarantee safety. By suggesting a new serial-parallel hybrid type for the service robot which separates into Positioning motion and orienting motion, we can achieve large workspace and high strength-to-moving-weight ratio at the same time. A sliding mode controller can be designed for tracking the desired output using the Lyapunov stability theory and structural properties of pneumatic servo systems. Through many experiments of circular trajectory. the Pneumatic service robot is evaluated and verified.

Work chain-based inverse kinematics of robot to imitate human motion with Kinect

  • Zhang, Ming;Chen, Jianxin;Wei, Xin;Zhang, Dezhou
    • ETRI Journal
    • /
    • v.40 no.4
    • /
    • pp.511-521
    • /
    • 2018
  • The ability to realize human-motion imitation using robots is closely related to developments in the field of artificial intelligence. However, it is not easy to imitate human motions entirely owing to the physical differences between the human body and robots. In this paper, we propose a work chain-based inverse kinematics to enable a robot to imitate the human motion of upper limbs in real time. Two work chains are built on each arm to ensure that there is motion similarity, such as the end effector trajectory and the joint-angle configuration. In addition, a two-phase filter is used to remove the interference and noise, together with a self-collision avoidance scheme to maintain the stability of the robot during the imitation. Experimental results verify the effectiveness of our solution on the humanoid robot Nao-H25 in terms of accuracy and real-time performance.

Performance Improvement of Pneumatic Artificial Muscle Manipulators using Magneto-Rheological Brake (MR Brake를 이용한 공압근육매니퓰레이터의 지능제어)

  • Ahn, Kyoung-Kwan;Thanh, T.D.C.;Ahn, Young-Kong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.572-575
    • /
    • 2005
  • A novel pneumatic artificial muscle actuator (PAM actuator), which has achieved increased popularity to provide the advantages such as high strength and high power/weight ratio, low cost, compactness, ease of maintenance, cleanliness, readily available and cheap power source, inherent safety and mobility assistance to humans performing tasks, has been regarded during the recent decades as an interesting alternative to hydraulic and electric actuators. In order to realize satisfactory control performance, a variable damper Magneto Rheological Brake (MRB), Is equipped to the Joint of the manipulator. Superb mixture of conventional PID controller and a phase plane switching control method brings us a novel controller. This proposed controller is appropriate for a kind of plants with nonlinearity, uncertainties and disturbances. The experiments were carried out in practical PAM manipulator and the effectiveness of the proposed control algorithm was demonstrated through experiments, which had proved that the stability of the manipulator can be improved greatly in a high gain control by using MRB with phase plane switching control method and without regard for the changes of external inertia loads.

  • PDF

Analysis of a Dynamic PLS of the Biped Walking RGO-Robot for a Trainning of Rehabilitation (척수마비 재활훈련용 이족보행 RGO 로봇의 Dynam ic PLS 생체역학적 특성분석 <응력해석과 FEM을 중심으로>)

  • 김명회;장대진;박창일;박영필
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.136-141
    • /
    • 2002
  • This paper presents a design and a control of a biped walking RGO-robot and dynamic walking simulation for this system. The biped walking RGO-robot is distinguished from other one by which has a very light-weight and a new AGO type with servo motors. The gait of a biped walking RGO-robot depends on the constrains of mechanical kinematics and initial posture. The stability of dynamic walking is investigated by ZMP(Zero Moment Point) of the biped walking RGO-robot. It is designed according to a human wear type and is able to accomodate itself to human environments. The joints of each leg are adopted with a good kinematic characteristics. To test of the analysis of joint kinematic properties, we did the strain stress analysis of dynamic PLS and the study of FEM with a dynamic PLS. It will be expect that the spinal cord injury patients are able to train effectively with a biped walking AGO-robot.

  • PDF

Design and Control of a Dynamic PLS of the Biped Walking RGO-Robot for a Trainning of Rehabilitation (재활훈련용 이쪽보행 RGO 로봇의 Dynamic PLS 설계와제어 - <응력해석과 FEM을 중심으로>)

  • 김명회;장대진;박창일;박영필
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.238-243
    • /
    • 2002
  • This paper presents a design and a control of a biped walking AGO-robot and dynamic walking simulation for this system. The biped walking RGO-robot is distinguished from other one by which has a very light-weight and a new RGO type with servo motors. The gait of a biped walking AGO-robot depends on the constrains of mechanical kinematics and initial posture. The stability of dynamic walking is investigated by ZMP(Zero Moment Point) of the biped walking AGO-robot. It is designed according to a human wear type and is able to accomodate itself to human environments. The joints of each leg are adopted with a good kinematic characteristics. To test of the analysis of joint kinematic properties, we did the strain stress analysis of dynamic PLS and the study of FEM with a dynamic PLS. It will be expect that the spinal cord injury patients are able to train effectively with a biped walking RGO-robot.

  • PDF

The Waveform Control and Blowhole Generation in the Wave Pulse MIG Welding for Galvanized Steel Sheets (아연도금강판에 대한 중첩펄스 MIG 용접에서의 파형제어와 기공 발생 특성)

  • Cho Sang-Myung;Kim Ki-Jung;Lee Byung-Woo
    • Journal of Welding and Joining
    • /
    • v.23 no.1
    • /
    • pp.69-76
    • /
    • 2005
  • Recently, application of arc welding to galvanized carbon steel sheet is on the increasing Ould in the fields of automobile and construction industries. In arc welding process, zinc is evaporated in weld pool, even under the appropriate welding condition and produce blowhole and/or pit. Zinc gas cause instability of arc and increase spatter and fume. This research is purposed to minimize the heat-input and the formation of porosities in the welded joint of the galvanized carbon steel sheet using variable polarity AC wave pulse MIG welding system. An appropriate welding condition which showed low spatter and good bead appearance was acquired by applying the AC pulse MIG welding machine to DC duplicated MIG welding with the solid wire. When oxygen gas was added to shield gas of MIG welding for galvanized steel sheet, arc length was increased and arc stability was improved. In the AC duplicated welding, the loss of galvanized layer was decreased as the amount of heat-input was decreased when the EN ratio was increased under the condition that average welding current was evenly set.