• Title/Summary/Keyword: Joint space

Search Result 1,071, Processing Time 0.034 seconds

Full mouth rehabilitation through re-establishment of occlusal plane in partially edentulous patient with reduced vertical dimension accompanied by loss of posterior occlusal support (구치부 교합지지 상실과 수직고경 감소를 동반한 부분 무치악 환자에서 교합평면 회복을 통한 완전구강회복 증례)

  • Cho, Young Eun;Leesungbok, Richard;Lee, Suk Won;Choi, Joseph June Sirk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.3
    • /
    • pp.263-275
    • /
    • 2022
  • The loss of posterior occlusal support leads to further complications such as collapsed occlusal plane and reduced vertical dimension, and it may cause problems such as facial appearance change, reduced chewing efficiency, and temporomandibular joint disorders. In such case, it is necessary to re-establish occlusal plane and vertical dimension properly through accurate diagnosis and predictable treatment plan. This case report presents a 71-year-old female, whose occlusal plane was collapsed and posterior restorative space was insufficient. To perform a patient-friendly full mouth rehabilitation, proper vertical dimension and occlusal plane were decided by evaluation of interocclusal space at her physiologic mandibular rest position, swallowing, pronunciation, facial appearance, and the average length of anterior teeth. And then, the fixed provisional restorations were fabricated with the new occlusal position, and evaluated for 5 months with checking adaptation of masticatory muscles and any kind of clinical symptoms occurs or not. After confirmation of functional stability and esthetic satisfaction with the newly established occlusion, final definitive restorations were fabricated and inserted in the mouth. Through the above process, the treatment result was functionally and aesthetically satisfactory.

Analysis of grout injection distance in single rock joint (단일절리 암반에서 그라우팅 주입거리 분석)

  • Ji-Yeong Kim;Jo-Hyun Weon;Jong-Won Lee;Tae-Min Oh
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.25 no.6
    • /
    • pp.541-554
    • /
    • 2023
  • The utilization of underground spaces in relation to tunnels and energy/waste storage is on the rise. To ensure the stability of underground spaces, it is crucial to reinforce rock fractures and discontinuities. Discontinuities, such as joints, can weaken the strength of the rock and lead to groundwater inflow into underground spaces. In order to enhance the strength and stability of the area around these discontinuities, rock grouting techniques are employed. However, during rock grouting, it is impossible to visually confirm whether the grouting material is being smoothly injected as intended. Without proper injection, the expected increases in strength, durability, and degree of consolidation may not be achieved. Therefore, it is necessary to predict in advance whether the grouting material is being injected as designed. In this study, we aimed to assess the injection performance based on injection variables such as the water/cement mixture ratio, injection pressure, and injection flow using UDEC (Universal Distinct Element Code) numerical program. Additionally, numerical results were validated by the lab experiment. The results of this study are expected to help optimize variables such as injection material properties, injection time, and pump pressure in the grouting design in the field.

Implementation of Motion Analysis System based on Inertial Measurement Units for Rehabilitation Purposes (재활훈련을 위한 관성센서 기반 동작 분석 시스템 구현)

  • Kang, S.I.;Cho, J.S.;Lim, D.H.;Lee, J.S.;Kim, I.Y.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.7 no.2
    • /
    • pp.47-54
    • /
    • 2013
  • In this paper, we present an inertial sensor-based motion capturing system to measure and analyze whole body movements. This system implements a wireless AHRS(attitude heading reference system) we developed using a combination of rate gyroscope, accelerometer and magnetometer sensor signals. Several AHRS modules mounted on segments of the patient's body provide the quaternions representing the patient segments's orientation in space. We performed 3D motion capture using the quaternion data calculated. And a method is also proposed for calculating three-dimensional inter-segment joint angle which is an important bio-mechanical measure for a variety of applications related to rehabilitation. To evaluate the performance of our AHRS module, the Vicon motion capture system, which offers millimeter resolution of 3D spatial displacements and orientations, is used as a reference. The evaluation resulted in a RMSE of 2.56 degree. The results suggest that our system will provide an in-depth insight into the effectiveness, appropriate level of care, and feedback of the rehabilitation process by performing real-time limbs or gait analysis during the post-stroke recovery process.

  • PDF

Study on Teachers' Understanding on Generating Random Number in Monte Carlo Simulation (몬테카를로 시뮬레이션의 난수 생성에 관한 교사들의 이해에 관한 연구)

  • Heo, Nam Gu;Kang, Hyangim
    • School Mathematics
    • /
    • v.17 no.2
    • /
    • pp.241-255
    • /
    • 2015
  • The purpose of this study is to analyze teachers' understanding on generating random number in Monte Carlo simulation and to provide educational implications in school practice. The results showed that the 70% of the teachers selected wrong ideas from three types for random-number as strategies for problem solving a probability problem and also they make some errors to justify their opinion. The first kind of the errors was that the probability of a point or boundary was equal to the value of the probability density function in the continuous probability distribution. The second kind of the errors was that the teachers failed to recognize that the sample space has been changed by conditional probability. The third kind of the errors was that when two random variables X, Y are independence of each other, then only, joint probability distribution is satisfied $P(X=x,\;Y=y)=p(X=x){\times}P(Y=y{\mid}X=x)$.

Evaluation on Bearing Capacity of End Girder Member with Local Corrosion (지점부 부재의 부식손상에 따른 강거더 단부 지압강도 평가)

  • Ahn, Jin Hee;Lee, Won Hong;Kim, In Tae;Jeong, Young Soo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.5
    • /
    • pp.74-82
    • /
    • 2017
  • Localized corrosions damages in their structural sections can be occurred affected by installed environment conditions with high temperature as near the coastline and humidity or their poor maintenance situation. In bearing supports of steel bridges, especially, lower web and vertical stiffener in end girder support can be easily corroded because of relatively higher humidity due to the narrow space in the end of girder and the wetted accumulated sediments affected by rain water or antifreezing admixture leaked from expansion joint. It can be related to change in their structural performance. In this study, thus, bearing strength test specimens were fabricated considering corrosion damage in the web and vertical stiffeners and the change in their bearing strengths were experimentally evaluated. From the test results, localized corrosion damage of structural members in the end girder affected the bearing strength of end girder support, especially, localized corrosion damage of the vertical stiffener relatively highly affected their bearing strengths.

Influence of Pillar Width on the Stability of Twin Tunnels Using Scaled Model Tests (쌍굴터널 간 이격거리가 터널 안정성에 미치는 영향에 관한 모형실험 연구)

  • Kim, Jong-Woo
    • Tunnel and Underground Space
    • /
    • v.25 no.5
    • /
    • pp.423-434
    • /
    • 2015
  • Scaled model tests were performed to investigate the influence of pillar width, rock strength and isotropy/anisotropy on the stability of twin tunnels. Test models had respectively different pillar widths, uniaxial compressive strengths of modelling materials and model types, where both the deformation behaviors around tunnels and the biaxial pressure data at a time of pillar cracking were analysed. The cracking pressures of the higher strength models were higher than the lower strength models, whereas the percentage of cracking pressure to uniaxial compressive strength of modelling materials showed an opposite tendency. The cracking pressures of the shallower pillar width models were lower than the thicker models, moreover the percentage of that showed a same tendency. It has been found that the pillar width was one of the main factors influencing on the stability of twin tunnels. Model types such as isotropy/anisotropy also influenced on the stability of twin tunnels. The anisotropic models showed lower values of both cracking pressures and the percentage of that than the isotropic models, where the pillar cracks of anisotropic models were generated with regard to the pre-existing joint planes.

An Illumination-Insensitive Stereo Matching Scheme Based on Weighted Mutual Information (조명 변화에 강인한 상호 정보량 기반 스테레오 정합 기법)

  • Heo, Yong Seok
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.11
    • /
    • pp.2271-2283
    • /
    • 2015
  • In this paper, we propose a method which infers an accurate disparity map for radiometrically varying stereo images. For this end, firstly, we transform the input color images to the log-chromaticity color space from which a linear relationship can be established during constructing a joint pdf between input stereo images. Based on this linear property, we present a new stereo matching cost by combining weighted mutual information and the SIFT (Scale Invariant Feature Transform) descriptor with segment-based plane-fitting constraints to robustly find correspondences for stereo image pairs which undergo radiometric variations. Experimental results show that our method outperforms previous methods and produces accurate disparity maps even for stereo images with severe radiometric differences.

Arthroscopic Findings and Treatment of Chronic Lateral Ankle Instability (만성 족관절 외측 불안정성의 관절경적 소견 및 치료)

  • Lee, Seung-Yong;Kim, Gab-Lae;Park, Deok-Yong
    • Journal of Korean Foot and Ankle Society
    • /
    • v.11 no.2
    • /
    • pp.198-203
    • /
    • 2007
  • Purpose: To assess the arthroscopic findings in chronic lateral ankle instability and to evaluate the results of modified $Brostr{\ddot{o}}m$ operation and arthroscopic procedures. Materials and Methods: Twenty-nine cases with chronic lateral ankle instability were treated with modified $Brostr{\ddot{o}}m$ operation and ankle arthroscopy from May 2004 to January 2007. There were 19 male and 10 female with the mean age of 29.7 years. Mean follow up period was 15.8 months. All patients were checked preoperative stress anterior drawer and varus test with X-ray. Results: Associated injuries were 28 fat impingement projected into the joint between distal tibio-fibular space, 20 anterior impingement of soft tissue, 19 osteochondral defects and 13 loose body. Preoperative AOFAS score of pain, function and alignment were 28.9, 34.1 and 7.9 each other. They were improved into 38.7, 40.8 and 9.8 postoperatively. Conclusions: Modified $Brostr{\ddot{o}}m$ operation with ankle arthroscopy for chronic lateral ankle instability is believed to be a reliable option to obtain satisfactory results. Careful attention to the associated injuries such as distal fat impingement, anterior impingement, osteochondral defect and loose body is needed during the arthroscopy.

  • PDF

A Study on The Furniture Design for Home Office Worker (재택근무자를 위한 홈 오피스 가구디자인에 관한 연구)

  • 양영완
    • Archives of design research
    • /
    • v.11 no.2
    • /
    • pp.17-28
    • /
    • 1998
  • With the renewed definition of "office". it's function and role has been reduced. Therefore. home oofices are beginning to draw people's attention. Office within the home is called SOHO (Small Office Home Office). SOHO has become possible with the development of information and telecommunication network technology. Recently. companies are adopting the SOHO system along with the trends of business restructuring. The SOHO offers workers to enjoy more flexible work time and enhance concentration thus improving jop efficiency. Companies will be able to cut down on fixed expenses and increase productivity. In addition. such working conditions will contribute to relieve traffic and environmental problems and furthermore it will make it possible to take advantage of potential workforce of women. the elderly and the handicapped. "Home Office" is expected to be one of the prevailing work system in the near future. Therefore. it is all the more important to study design problems including space design and furniture arrangement in order to improve work efficiency and provide a creative working environment. Moreover. architects and interior designers as well as experts on related fields such as information network. telecommunications. management and employment should continue to carry out joint researches for reasonable home office furniture and environment design.nd environment design.

  • PDF

Beach-chair lateral traction position using a lateral decubitus distracter in shoulder arthroscopy

  • Kim, Kyung-Cheon;Rhee, Kwang-Jin;Shin, Hyun-Dae;Byun, Ki-Yong
    • The Academic Congress of Korean Shoulder and Elbow Society
    • /
    • 2008.03a
    • /
    • pp.164-164
    • /
    • 2008
  • The beach-chair traction position is designed to allow the use of traction while allowing the surgeon to orient the shoulder in an upright position and convert to an open procedure, if necessary. The patient is placed in the beach-chair position under general anesthesia. A three-point shoulder holder (Arthrex, Naples, Florida) is attached to the rail of the operating table on the same side as the surgeon, whereas it is placed on the side opposite the surgeon in the lateral decubitus position. A shoulder traction and rotation sleeve (Arthrex) are affixed to the arm following the manufacturer's instructions. Positioning the thumb toward the closed side of the sleeve ensures a field for the anterior portion of the rotator cuff and prevents the tendency of the suspension apparatus to place the arm in internal rotation. The arm is maintained in 30 to 40 degree abduction and 30 to 40 degree flexion by controlling the length and height of the bar and the location of the universal clamp. The universal clamp allows multiple planes of adjustment to control abduction and forward movement of the arm. The sleeve is attached to the longitudinal traction cable using a sterile hook, and a lateral strap is secured around the proximal portion of the sleeve to the overhead traction cable to ensure a field for glenohumeral reconstruction. The use of a lateral strap permits ideal shoulder positioning for improved access to the anterior and inferior glenohumeral joint. The lateral strap can be released or removed to widen the subacromial space during subacromial decompression or rotator cuff repair. A 10-lb weight is attached to the longitudinal traction cable for an average-sized person.

  • PDF