• Title/Summary/Keyword: Joint rotation

Search Result 669, Processing Time 0.023 seconds

Finite Element Analysis of a Full-scale, Rapid-Disassembly, Carbon-Minimized Dismantle Connection Subjected to Cyclic Loading (주기적 하중을 받는 탄소감축을 위한 조립 해체가 용이한 급속 시공 접합부(TZcon)의 수치해석 연구)

  • Dave Montellano Osabel;Hyeong-Jin Choi;Sang-Hoon Kim;Young-Ju Kim;Jae-Hoon Bae
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.37 no.4
    • /
    • pp.275-282
    • /
    • 2024
  • A recently proposed rapid-disassembly , carbon-minimized dismantle connection was tested using cyclic loading. To better understand the behavior of the test specimen, three-dimensional finite element (3D-FE) analyses were conducted using a "tied model" (bolted contact surfaces are tied together) and a "bolt-slip model" (contact surfaces slip and separate). The tied model suggests that plastic hinging of the beam occurs if the proposed connection behaves rigidly. The bolt-slip model suggests that the proposed connection, if manufactured and assembled properly, can dissipate energy to about 0.5 times that experienced by a rigid connection. However, when compared in a test, its moment-rotation hysteresis curve does not match well, which suggests that the low performance of the test specimen is attributable to a manufacturing deficiency. Regardless, the results corroborate the pinching phenomenon observed in the experimental hysteresis and fracture failure of the test specimen.

The Effect of Spiral Balance Taping on Postoperative Sequelae in Breast Cancer : Case study (스파이랄 발란스 테이핑이 유방암 환자의 수술 후 후유증에 미치는 영향 : 사례연구)

  • Su-Ji Kang;Dae-Hee Lee;Cheul Jang;Back-Vin Lim
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.12 no.3
    • /
    • pp.37-47
    • /
    • 2024
  • Purpose : Cancer survivors often suffer from postoperative sequelae. the diagnosing and provision of manual therapy using spiral taping significantly improves the quality of life of cancer patients. The aim of this case study is to investigate the immediate effects of spiral taping on pain, range of motion (ROM), chemotherapy-induced peripheral neuropathy (CIPN), and lymphedema following breast cancer surgery. Methods : The taping techniques were performed as follows by spiral taping. The measurements were taken before, in the middle, and after taping using a mobile phone camera, tape measure, and a numerical rating score (NRS). The evaluation employed a single-group pre-post design based on a primitive experimental design. Results : Out of four patients, all four exhibited Reverse circle flow energy (RCFE), Passive cervical right (Rt) rotation test, anterior-posterior movement pattern, nerve type (+), cold energy (CE), sangcho acupuncture point, blood clot, hwal point. Comparing before and after treatment, almost all values were reduced to zero after treatment in terms of pain complaints. The lack of range of motion (ROM) caused by the shortened tissue after surgery did not increase. The range of motion (ROM) lost due to pain returned to normal. The circumference of lymphedema did not show a tendency. The symptoms of CIPN improved. Conclusion : There was a significant change in joint range of motion, with pain decreasing, but there were structural limitations in the tissue due to total resection, and the chemotherapy-induced peripheral neuropathy scale. It was effectively treated surgical site pain, axillary membrane syndrome-induced pain, and unexplained pain. While there was a treatment effect for lymphedema in the evaluation of circumference values, there was no significant change in circumference. There was a significant effect on chemotherapy-induced peripheral neuropathy, particularly in treating numbness in the feet, which is a side effect of TC anticancer drugs. This case study found that spiral balance taping provides a rapid therapeutic effect for most side effects in patients who have undergone total breast cancer resection. However, the generalization is limited due to the small sample size, and further research is needed to determine the extent to which the effects of one treatment are maintained.

Clinical Comparison of Two Types of Hook Plate in Surgical Treatment of Acromioclavicular Dislocation - AO Hook Plate and Wolter Plate - (견봉 쇄골 관절 탈구의 수술적 치료에서 두 가지 갈고리 금속판의 임상적 비교 - AO Hook Plate와 Wolter Plate -)

  • Choi, Jea-Yeol;Kim, Eugene;Jeong, Haw-Jae;Ahn, Jin Whan;Shin, Hun-Kyu;Park, Se-Jin;Lee, Seung-Hee;Lee, Jae-Wook;Choi, Kyu-Bo
    • Clinics in Shoulder and Elbow
    • /
    • v.15 no.2
    • /
    • pp.123-129
    • /
    • 2012
  • Objective: To evaluate if acromial locking in hook plate is necessary for surgical treatment of acromioclavicular dislocation by compare Wolter plate and AO hook plate. Methods: Seventy one patients who have Rockwood type III to V acromioclavicular joint dislocation treated with AO hook plate and Wolter plate were involved. Among them, 39 patients were treated with Wolter hook plate and 32 patients with AO hook plate. The Constant-Murley score and the range of motion of shoulder joint were measured on postoperative 1st ,$3^{rd}$, $6^{th}$ and $12^{th}$ months, and the radiological complications involving plate and bone were investigated. Results: Constant-Murley score of postoperative one year were $83.2{\pm}6.8$ in AO hook plate group and $85.2{\pm}5.3$ in Wolter plate group without statistical difference (p<0.05). Faster recover of forward elevation and external rotation were examined in Wolter plate group at first and third months after surgery than those of AO hook plate group, but there were no significant difference between after six months or later after surgery. Four cases of loosen or broken screws and one case of pull-out of plate were found in Wolter plate group. Seven cases of subacromial bony erosion and one periprosthetic fracture were found in AO hook plate group. Conclusion: Although clinical outcomes of both two methods were same, no matter if acromial locking system was or not. More radiological complication of plate and bone were found in AO hook plate than that of Wolter plate. However also had disadvantage like larger incision during surgery.

Functional Result of Limb Salvage Surgery with Tumor Prosthesis for Osteosarcoma of Proximal Tibia (근위 경골 골육종의 종양대치물을 이용한 사지 구제술 후의 기능 평가)

  • Bahk, Won-Jong;Sohn, Jong-Min;Chung, Yang-Guk;Kang, Yong-Koo
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.7 no.4
    • /
    • pp.139-143
    • /
    • 2001
  • Purpose : Limb salvage for osteosarcoma of proximal tibia is challenging problem due to difficulties in mobilizing or retracting the main neurovascular structure, inadequate soft tissue coverage, and unsolved problem of patellar tendon reattachment to endoprosthesis. The authors analyzed the functional result of limb salvage using tumor prosthesis with medial gastrocnemius rotation plasty for osteosarcama of the proximal tibia. Materials and Methods : Eleven patients with histologically proven osteosarcoma of the proximal tibia, treated with adjuvant and neoadjuvant chemotherapy and limb salvage operation with tumor prosthesis between January 1992 and December 1998 at our Medical Center, were selected. There were 6 male and 5 female. Age ranged from 15 years to 23.7 years with an average of 23.7 years. Follow-up period ranged from 1 year to 4.5 years with an average of 2.5 years. The final functional result was evaluated using the method by ISOLS, 1993. The factors include pain, functional activities, emotional acceptance, use of external supports, walking ability and gait. Each of the factors has been scored from 0 to 5 depending on the appropriate description or data. The rating score is determined by dividing the individual factor scores into the total score and indicates percentage of normal function. Results : The overall functional result ranged from 53,3% to 86.7% with an average of 68.3% of normal function. In details, the averages were 82.5% for pain, 62.5% for functional activities, 67.5% for emotional acceptance, 77.5% for use of external supports, 62.5% for walking ability, and 57.5% for gait. The average range of motion of the knee joint was $5^{\circ}$ extension and $85^{\circ}$ flexion. Five patients have extension lag ranged from $5^{\circ}$ to $15^{\circ}$ with an average of $10^{\circ}$. Two patients suffered postoperative infection. One was treated with antibiotics injection only, but the other needed removal of the prosthesis and knee fusion. Both of them showed unsatisfactory result. C o n c l u s i o n : The overall functional result after limb salvage using tumor prosthesis with medial gastrocnemius rotational flap for osteosarcoma of the proximal tibia was relatively satisfactory in case of no postoperative infection. The patients were less satisfactory in functional activities, emotional acceptance and gait than pain, use of external supports due to limitation of motion and extension lag. More aggressive postoperative physical therapy and protection with brace for 6~9 months as well as surgical technique is mandatory for more satisfactory result.

  • PDF

SURFACE CHANCE OF EXTERNAL HEXAGON OF IMPLANT FIXTURE AND INTERNAL HEXAGON OF ABUTMENT AFTER REPEATED DELIVERY AND REMOVAL OF ABUTMENT (지대주의 반복적인 착탈에 따른 임플랜트 고정체의 external hexagon과 지대주 internal hexagon의 변화에 관한 연구)

  • Jung Seok-Won;Kim Hee-Jung;Chung Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.4
    • /
    • pp.528-543
    • /
    • 2005
  • Statement of problem: Repeated delivery and removal of abutment cause some changes such as wear, scratch or defect of hexagonal structure. It may increase the value of rotational freedom(RF) between hexagonal structures. Purpose: The purpose of this study was to evaluate surface changes and rotational freedom between the external hexagon of the implant fixture and internal hexagon of abutment after repeated delivery and removal under SEM and toolmaker's microscope. Materials and methods: Implant systems used for this study were 3i and Avana. Seven pail's of implant fixture, abutment and abutment screws for each system were selected and all fixtures were perpendicularly mounted in liquid unsaturated polyesther with dental surveyor. Each one was embedded beneath the platform of fixture. Surfaces of hexagonal structure before repeated closing and opening of abutment were observed using SEM and rotational freedom was measured by using toolmaker's microscope. Each abutment was secured to the implant future by each abutment screw with recommended torque value using a digital torque controller and was repeatedly delivered and removed by 20 times respectively. After experiment, evaluation for the change of hexagonal structures and measurement of rotational freedom were performed. Result : The results were as follows; 1. Wear of contact area between implant fixture and abutment was considerable in both 3i and Avana system. Scratches and defects were frequently observed at the line-angle of hexagonal structures of implant fixture and abutment. 2. In the SEM view of the external hexagon of implant fixture, the point-angle areas at the corner edge of hexagon were severely worn out in both systems. It was more notable in the case of 3i systems than in that of Avana systems. 3. In the SEM view of the internal hexagon of abutment, Gingi-Hue abutment of 3i systems showed severe wear in micro-stop contacts that were machined into the corners to prevent rotation and cemented abutment of Avana systems showed wear in both surface area adjacent to the corner mating with external hexagon of implant fixture. 4 The mean values of rotational freedom between the external hexagon of the implant fixture and internal hexagon of abutment were 0.48$\pm$0.04$^{\circ}$ in pre-tested 3i systems and 1.18$\pm$0.25$^{\circ}$ after test, and 1.80$\pm$0.04$^{\circ}$ in pre-tested Avana systems and 2.61$\pm$0.16$^{\circ}$ after test. 5. Changes of rotational freedom after test shouted statistical)y a significant increase in both 3i and Avana systems(P<0.05, paired t-test). 6. Statistically, there was no significant difference between amount of increase in the rotational freedom of 3i systems and amount of increase in that of Avana ones(P>0.05, unpaired t-test). Conclusion: Conclusively, it was considered that repeated delivery and remove of abutment by 20 times would not have influence on screw joint stability. However, it caused statistically the significant change of rotational freedom in tested systems. Therefore, it is suggested that repeated delivery and remove of abutment should be minimal as possible as it could be and be done carefully Additionally, it is suggested that the means or treatment to prevent the wear of mating components should be devised.

The Use of Arthroscopic UU Stich for Rotator Cuff Tear and Clinical Results (회전근 개 파열의 관절경하 봉합에서 새로운 봉합 방법의 이용)

  • Ko, Sang-Hun;Shin, Seung-Myeong;Choi, Young-Jin;Cha, Jae-Ryong;Park, Han-Chang
    • Clinics in Shoulder and Elbow
    • /
    • v.14 no.1
    • /
    • pp.67-72
    • /
    • 2011
  • Purpose: There are various known methods for arthroscopic rotator cuff repair. The purpose of this retrospective study is to report on the clinical results and anatomical results of UU repair surgery, which is a new repair method. Materials and Methods: We enrolled 156 patients (88 men and 68 women) who underwent UU repair for rotator cuff tears from January 2009 to May 2010 in our hospital. Their average age was 55 years old (range: 38~75 years old) and the average follow-up period was 12 months (range: 6~23 months). For determining the results, we evaluated the VAS for pain, the daily living index (ADL) in the ASES scores, the UCLA and KSS scores, and all these tests were conducted at the first hospital visit and 6 months and 1 year after surgery and at the final follow-up. During the follow-up period, MRI was performed 3 and 6 months after surgery only in the patients who consented to MRI scans to confirm the presence of re-rupture. Results: The average scores of the VAS as a pain indicator decreased from 7.0 before surgery to 2.7 after surgery (p<0.05). The UCLA and KSS scores increased from 22.2 to 32.5 and from 83.7 to 91.5, and the changes was significant (p<0.05). For the active joint range of motion, the average forward flexion was improved from 125 to 175 degrees, the average lateral external rotation was improved from 38 to 58 degrees, and the average abduction was improved from 104 to 169 degrees. Out of a total of 156 patients, re-rupture was observed in 4 cases (3%) of 117 cases (75%) for which MRI was performed (with consent) between 3 and 6 months after surgery. Conclusion: UU repair surgery as arthroscopic repair of rotator cuff tear is a good repair method that shows excellent clinical results and a low re-rupture rate.

Arthroscopic Treatment using Bioabsorbable Knotless Anchor for Anterior Instability of Shoulder (관절경하 생체흡수형 Knotless Anchor를 이용한 견관절 전방 불안정성의 치료)

  • Lee, Yong-Jae;Lee, Tong-Joo;Lim, Kwang-Yul;Kim, Myung-Ku
    • Journal of the Korean Arthroscopy Society
    • /
    • v.8 no.2
    • /
    • pp.103-108
    • /
    • 2004
  • Purpose: This study reported the outcomes following the use of bioabsorbable knotless anchor in patients with anterior instability of shoulder. Methods: We studied fifteen cases with traumatic anterior shoulder instability underwent arthroscopic Bankart repair with bioabsorbable knotless suture anchor between January 2003 and June 2003. Among fifteen patients, fourteen were male and one was female, with a mean patient age of 24 years (range 16-42). The mean follow-up was 14 months (range 12-18 months). We compared with operation time of twenty cases of arthroscopic Bankart repair by the suture anchor technique between January 2002 and October 2002. Results: Neither recurrent dislocation nor subluxation was happened in postoperative follow-up. Mean score for functional evaluation by Rowe et al. was 89.4 and that for patient subjective satisfaction was 87,5. At last follow-up period, average shoulder range of motion for flexion and external rotation was 171$^{\circ}$ and 54$^{\circ}$ respectively. All patients were satisfied except three who had an apprehension at the follow up. During Bankart repair, it took an average of 25.5 minutes for one knot with the use of suture anchor technique whereas an average of 16.5 minutes for one knot with the use of bioabsorbable knotless anchor. Significantly, we saved operation time with the use of bioabsorbable knotless anchor (P<0.05).Conclusion: Repairing the Bankart lesion with the use of knotless anchor technique has the advantage of obtaining good capsular tensioning and saving operation time. And it is considered to be very successful in treating shoulder instability without recurrent dislocation or subluxation.

  • PDF

A study on Yang Shi Tai Chi Chuan in Bartenieff Fundamentals Perspectives (바티니에프 기본원리를 통해 본 양식 태극권에 관한 연구)

  • Wang, Zhiquan
    • Trans-
    • /
    • v.8
    • /
    • pp.95-127
    • /
    • 2020
  • This research is based on using Bartenieff Fundamentals to analyze the fundamentals of Tai Chi Chuan's movements in order to develop the methods of relaxation from Tai Chi Chuan's principle movement movements It also shows that the two techniques have commonalities in many ways. First of all, taking a philosophical approach on the body movements of Tai Chi Chuan and Bartenieff, for both methods the ultimate goal is the integration of mind and body. In other words, there is a thread of connection between the East's body and mind monism and the west's Body Awareness. Secondly, looking at it from a Breath Support standpoint as used in the Bartenieff method, the two methods both use the breathing to naturally move the body and relax the body. In Tai Chi Chuan the Breath is the basis of life and the strength of the Body. So the breathing of Tai Chi chuan is what makes body and mind communicate, harmonize and integrate. In other words, Breathing in Tai Chi is realized through mental fusion and affects the movements. This is the same as the Breath Support of Bartenieff. It is said that in every aspect the Breath Support of Bartenieff influences the movement and changes both the inner and outer form of the body. Thirdly, looking at the Core Support used in the Bartenieff method, both methods emphasize core. At the same time of moving and being conscious of one's core, the usage of muscles can be deeper rather than superficial and this enables strong and flexible movement. In Tai Chi Chuan abdominal muscles used when one coughs are consciously engaged through abdominal breathing and so strength is collected in the core. When one exercises like that the core becomes more stable and breathing becomes more smooth. Fourthly, analyzing the Rotary Factor used in the Bartenieff Fundamentals, they both use rotary movement to reach the goal of physical relaxation. The rotation factor of Bartenieff allows movement to be easier and more free because of the characteristic of joint exercise where the center axis moved in three dimensions, this is the same in Tai Chi chuan. According to Tai Chi chuan's circle and Spiral Movements, it can achieve the relaxation through switching into a seamless flow and access space as much as possible. Finally, when looking at Developmental Patterning through Bonnie Bainbridge Cohen's Body-Mind Centering Work theory, presented from Bartenieff developmental model are similar with the developmental process of Tai Chi chuan Breath, Core-Distal Connectivity/Navel Radiation, Head-Tail Connectivity/Spinal Movement, Upper-Lower Connectivity/Homologous, Body-Half Connectivity/Homo-Lateral Connectivity, Cross-Lateral Connectivity/Contra-Lateral Connectivity. They are all similar. In other words, in Tai Chi Chuan energy is gathered in the core through breathing, upper and lower body are connected through the spine, not only homo-laterally but also cross-laterally. Through this study the expression of the dance movements can be more natural. Additionally based on the Body Awareness balance usage of the central axis, joints and body can develop the relax technique.

  • PDF

Anterolateral Ligament of the Knee: Anatomy, Biomechanics, Techniques, and Clinical Outcome (슬관절 전외측인대의 해부학, 생역학, 수술법 및 임상적 결과)

  • Kim, Seong Hwan;Lee, Tae-Hyub;Park, Yong-Beom
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.4
    • /
    • pp.281-293
    • /
    • 2020
  • An anterior cruciate ligament (ACL) reconstruction is one of the most frequent surgical procedures in the knee joint, but despite the better understanding of anatomy and biomechanics, surgical reconstruction procedures still fail to restore rotational stability in 7%-16% of patients. Hence, many studies have attempted to identify the factors for rotational laxity, including the anterolateral ligament (ALL), but still showed controversies. Descriptions of the ALL anatomy are also confused by overlapping nomenclature, but it is usually known as a distinctive fiber running in an anteroinferior and oblique direction from the lateral epicondyle of the femur to the proximal anterolateral tibia, between the fibular head and Gerdy's tubercle. The importance of the ALL as a secondary restraint in the knee has been emphasized for successful ACL reconstructions that can restore rotational stability, but there is still some controversy. Some studies reported that the ALL could be a restraint to the tibial rotation, but not to anterior tibial translation. On the other hand, some studies reported that the role of ALL in rotational stability would be limited as a secondary structure because it bears loads only beyond normal biomechanical motion. The diagnosis of an ALL injury can be performed by a physical examination, radiology examination, and magnetic resonance imaging, but it should be assessed using a multimodal approach. Recently, ALL was considered one of the anterolateral complex structures, as well as the Kaplan fiber in the iliotibial band. Many studies have introduced many indications and treatment options, but there is still some debate. The treatment methods are introduced mainly as ALL reconstructions or lateral extra-articular tenodesis, which can achieve additional benefit to the knee stability. Further studies will be needed on the indications and proper surgical methods of ALL treatment.