• Title/Summary/Keyword: Joint condition

Search Result 1,235, Processing Time 0.024 seconds

Evaluation of Dispersivity and Resistance of the Adhesive Joint According to Dispersion Methods of CNT (CNT 분산 방법에 따른 접착조인트의 저항 및 분산성 평가)

  • Lee, Bong-Nam;Kim, Cheol-Hwan;Kweon, Jin-Hwe;Choi, Jin-Ho
    • Composites Research
    • /
    • v.28 no.6
    • /
    • pp.348-355
    • /
    • 2015
  • NDT (Non Destructive Test) of the adhesive joints is very important because their strengths have greatly affected by the worker's skill and environmental condition. Recently, the electric impedance method in which 1-2 wt% CNT was dispersed in the adhesive and the electric resistance of the adhesive joint was measured was suggested for the defect detection of the adhesive joint. The uniform dispersion of CNT in the electric impedance method is very important to make a constant electric resistance of the adhesive joint and the accuracy of defect detection depends on the uniform dispersion. In this paper, the adhesive joints in which CNT was dispersed in the adhesive by the four dispersion methods were made and their electric resistance were measured. The pre-process and evaporation process of CNT using the ultrasonic method and agitation method was used and the effective dispersion method was suggested. Also, the criteria to evaluate the dispersivity was proposed.

Design of Infrared Angular Sensor for Human Joint Angle (관절각 측정을 위한 적외선 각도 센서 연구)

  • Oh, Han-Byeol;Kim, Ji-Sun;Kim, A-Hee;Goh, Bong-Jun;Kim, Jun-Sik;Lee, Eun-Suk;Choi, Ju-Hyeon;Jun, Jae-Hoon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.5
    • /
    • pp.792-798
    • /
    • 2015
  • Joint angle generally can be measured to check the recovery process in rehabilitation field. This paper suggests to measure joint angle with Infrared sensor based on triangulation principle. We performed various experiments to find the optimal condition of the sensor’s attached distance, height, and angle. The results were compared with commercial goniometer for accuracy. The proposed infrared joint angle sensor can be effectively used in rehabilitation and sport science fields.

Optimal Joint Position in Concrete Pavement Slab over Skewed Box Culvert (수평으로 경사진 박스암거 위 콘크리트 포장 슬래브의 최적 줄눈위치)

  • Yeom, Woo Seong;Jeong, Ho Seong;Yan, Yu;Sohn, Dueck Soo;Lee, Jae Hoon;Jeong, Jin Hoon
    • International Journal of Highway Engineering
    • /
    • v.15 no.5
    • /
    • pp.47-55
    • /
    • 2013
  • PURPOSES : The purpose of this study is to investigate the optimal joint positions which can minimize distresses of concrete pavement containing box culvert with horizontally skewed angles. METHODS : The concrete pavement containing the box culvert with different skewed angles and soil cover depths was modeled by 3 dimensional finite element method. The contact boundary condition was used between concrete and soil structures in addition to the nonlinear material property of soil in the finite element model. A dynamic analysis was performed by applying the self weight of pavement, negative temperature gradient of slab, and moving vehicle load simultaneously. RESULTS : In case of zero skewed angle ($0^{\circ}$), the maximum tensile stress of slab was the lowest when the joint was positioned directly over side of box culvert. In case there was a skewed angle, the maximum tensile stress of slab was the lowest when the joint passed the intersection between side of the box culvert and longitudinal centerline of slab. The magnitude of the maximum tensile stress converged to a constant value regardless the joint position from 3m of soil cover depth at all of the horizontally skewed angles. CONCLUSIONS : More reasonable and accurate design of the concrete pavement containing the box culvert can be possible based on the research results.

Comparison of Sesamoid Bone Position and Hallux Valgus Angle in Weight Bearing Conditions between Subjects with and without Hallux Valgus

  • Kim, Moon-Hwan;Jeon, In-Cheol;Hwang, Ui-Jae;Kim, Young
    • The Journal of Korean Physical Therapy
    • /
    • v.28 no.6
    • /
    • pp.381-384
    • /
    • 2016
  • Purpose: Previous studies reported changes in the first metatarsophalangeal (MTP) joint angle in relation with and without weight bearing, but it is unclear whether sesamoid bone of the great toe changes in weight bearing conditions particularly in subjects with hallux valgus (HV). To investigate how weight bearing conditions can affect the position of the medial sesamoid bone (MSB), first MTP joint angle, and second intermetatarsal angle (IMA) in the recruited subjects. Methods: Subjects were recruited 24 with HV and 21 without HV in study. X-rays were taken in the weight bearing and non-weight bearing conditions. The distance of the MSB, first MTP joint angle, and second IMA were measured from the radiographs. Data were analyzed by paired and Independent t-test. The statistical significance level was p<0.05. Results: In both groups, the first MTP joint angles and the distance of the MSB were significantly smaller, while the second IMA was significantly greater in the weight bearing condition. The difference in the distance of the MSB between the two postures was significantly greater in the group with HV. Conclusion: Weight bearing can affect the first MTP joint angle, second IMA, and position of the MSB; the change in the position of the MSB in weight bearing was greater in the group with hallux valgus. The difference in these variables between weight bearing and non-weight bearing conditions may be considered when measuring HV.

Effects of Artificial Leg Length Discrepancies on the Dynamic Joint Angles of the Hip, Knee, and Ankle During Gait

  • Kim, Yong-Wook;Jo, Seung-Yeon;Byeon, Yeoung-In;Kwon, Ji-Ho;Im, Seok-Hee;Cheon, Su-Hyeon;Kim, Eun-Joo
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.14 no.1
    • /
    • pp.53-61
    • /
    • 2019
  • PURPOSE: This study examined the dynamic range of motion (ROM) of the hip, knee, and ankle joint when wearing different shoe sole lifts, as well as the limb asymmetry of the range according to the leg length discrepancy (LLD) during normal speed walking. METHODS: The participants were 40 healthy adults. A motion analysis system was used to collect kinematic ROM data. The participants had 40 markers attached to their lower extremities and were asked to walk on a 6 m walkway, under three different shoe lift conditions (without an insole, 1 cm insole, and 2 cm insole). Visual3D professional software was used to coordinate kinematic ROM data. RESULTS: Most of the ROM variables of the short limbs were similar under each insole lift condition (p>.05). In contrast, when wearing a shoe with a 2 cm insole lift, the long limbs showed significant increases in flexion and extension of the knee joint as well as; plantarflexion, dorsiflexion, pronation, eversion, and inversion of the ankle joint (p<.05). Of the shoes with the insole lifts, significant differences in all ROM variables were observed between the left and right knees, except for the knee internal rotation (p<.05). CONCLUSION: As the insole lift was increased, more ROM differences were observed between the left and right limbs, and the asymmetry of the bilateral lower limbs increased. Therefore, appropriate interventions for LLD are needed because an artificial mild LLD of less than 2.0 cm could lead to a range of musculoskeletal problems of the lower extremities, such as knee and ankle osteoarthritis.

Carbonation Behavior of GGBFS-based Concrete with Cold Joint Considering Curing Period (재령 변화에 따른 콜드조인트를 가진 GGBFS 콘크리트의 탄산화 거동)

  • Cho, Sung-Jun;Yoon, Yong-Sik;Kwon, Seung-Jun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.6 no.4
    • /
    • pp.259-266
    • /
    • 2018
  • In the work, the carbonation behavior and strength characteristics in cold-joint concrete are evaluated for OPC(Ordinary Portland Cement) and GGBFS(Ground Granulated Blast Furnace Slag)concrete considering three levels of curing age (28, 91 and 365 days). The compressive strength in GGBFS concrete is level of 86% of OPC concrete at the 91 days of curing period, but is level of 107% at 365 curing days due to hydration reaction. Carbonation velocities in both OPC and GGBFS concrete significantly decease after 91 curing days. The effect of cold joint on carbonation is evaluated to be small in GGBFS concrete. The increasing ratios of carbonation velocity in cold joint are 1.06 and 1.33 for 28-day and 365-day curing condition, respectively. However they decreases to 1.08 and 1.04 for GGBFS concrete for the same curing conditions.

Anterior Cruciate Ligament Injury is Unlikely to Occur when Performing a Stable Weight Lifting Operation

  • Moon, Youngjin;Moon, Jeheon
    • Korean Journal of Applied Biomechanics
    • /
    • v.28 no.4
    • /
    • pp.199-205
    • /
    • 2018
  • Objective: The purpose of this study was to examine the effect of increase in barbell weight on closely related variable to the anterior cruciate ligament (ACL) injury which are knee joint kinematics, joint load, joint moment, and maximum load attainment point during snatch of the weight lifting. Method: The subjects of the study were 10 male Korean national weight lifting athletes (69 kg 5, 77 kg 5; age: $21.80{\pm}3.91yrs.$, height: $168.00{\pm}4.06cm$, weight: $75.00{\pm}4.02kg$, career: $7.8{\pm}3.99yrs.$, snatch records: $168{\pm}4.06kg$). The weight of the barbell during the snatch operation was set at 70%, 75% and 80% of the highest records for each subject studied. Results: The result obtained from the one-way repeated measure ANOVA are as follows: With increased barbell weight, the extension moment of the left knee joint was higher in the 80% condition than the 70% (p<.001). However, other variables were not statistically significant difference. According to the factor analysis of the variables related to maximum load attainment point of the ACL major injury variables, the first sub-factor was the internal shear force, the posterior shear force, the abduction moment, and the muscle activity of the VL. The second sub-factor was the extension moment of the knee joint, compressive force, adduction moment, and the third sub-factor was the muscle activity of BF. Conclusion: These results indicate that the possibility of ACL injury can be lowered when performing a stable snatch movement.

Predicted the behavior of the femur according to the loading condition using FEM (유한요소해석을 이용한 하중조건에 따른 대퇴골의 거동예측)

  • Song, Seung-Youp;Choi, Seong Dae
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.12 no.4
    • /
    • pp.3-9
    • /
    • 2013
  • Falling related injuries are categorized as the most serious and common medical problems experienced by the elderly. Hip joint fracture, one of the most serious consequences of falling in the elderly, occurs in only about 1% of falling. In this study, according to the loading conditions, the analysis is the behavior of the femur. The CT images using the commercial program "Mimics" the bones of three-dimensional CAD data generated, and we will analyze the results of finite element analysis. The boundary conditions on the basis of existing research has been simplified. In this paper, the whole femur was assumed to be isotropic linear elastic material. Predicted the behavior of the femur according to the loading condition, it can be help the development of high-precision artificial bones and joints can be treated with surgery and will be able to perform efficiently.

FBG sensor system for condition monitoring of wind turbine blades (풍력터빈 블레이드 상태 감시용 광섬유격자 센서시스템)

  • Kim, Dae-Gil;Kim, Hyunjin;Song, Minho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.8
    • /
    • pp.75-82
    • /
    • 2013
  • We propose a fiber grating sensor system for condition monitoring of large scale wind turbine blades. For the feasibility test of the proposed sensor system, a down-scaled wind turbine has been constructed and experimented. Fiber grating sensors were attached on a blade surface for distributed strain and temperature measurements. An optical rotary joint was used to transmit optical signals between the FBG sensor array and the signal processing unit. Instead of broadband light source, we used a wavelength-swept fiber laser to obtain high output power density. A spectrometer demodulation is used to alleviate the nonlinear wavelength tuning problem of the laser source. With the proposed sensor system we could measure dynamic strain and temperature profiles at multi-positions of rotating wind turbine blades.

A Study on the Selection of Fillet Weld Conditions by Considering the Tack Welds (가접부를 고려한 필릿 용접조건의 선정에 관한 연구)

  • Lee Jun-Yeong;Kim Jae-Yong;Kim Cheol-Hui
    • Proceedings of the KWS Conference
    • /
    • 2006.05a
    • /
    • pp.304-306
    • /
    • 2006
  • Positioning the workpiece accurately and preventing the weld distortion, tack welding is often performed before main welding in the construction of welded structures. The weld bead size of the tack weld is determined according to the workpiece thickness, weld length, weld joint type etc. However, this tack weld deteriorates the final weld bead profile, so that the grinding process is usually adopted for the uniform weld bead profile. In this study, an experimental method for the selection of optimal welding condition was proposed in the fillet weld which was done over the tack weld. This method uses the response surface analysis in which the leg length and the reinforcement height of weld bead were chosen as the quality variables of weld bead profile. The overall desirability function, which was combined desirability function for the two quality variables, was used as the objective function for getting the optimal welding condition. From the result, it was revealed that a uniform weld bead can be obtained by adopting the optimal welding condition which was determined according to the method proposed.

  • PDF