• Title/Summary/Keyword: Joint Power

Search Result 992, Processing Time 0.029 seconds

A Genetic Approach for Joint Link Scheduling and Power Control in SIC-enable Wireless Networks

  • Wang, Xiaodong;Shen, Hu;Lv, Shaohe;Zhou, Xingming
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.10 no.4
    • /
    • pp.1679-1691
    • /
    • 2016
  • Successive interference cancellation (SIC) is an effective means of multi-packet reception to combat interference at the physical layer. We investigate the joint optimization issue of channel access and power control for capacity maximization in SIC-enabled wireless networks. We propose a new interference model to characterize the sequential detection nature of SIC. Afterward, we formulize the joint optimization problem, prove it to be a nondeterministic polynomial-time-hard problem, and propose a novel approximation approach based on the genetic algorithm (GA). Finally, we discuss the design and parameter setting of the GA approach and validate its performance through extensive simulations.

A Study on Fault Prediction Algorithm and Failure Instance Analysis of Electric Power Relay (전력릴레이 고장사고 사례분석 및 고장예측 알고리즘 연구)

  • Kim, Yong-Kyu;Kwak, Dong-Kurl;Lee, Seung-Chul
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.15-16
    • /
    • 2015
  • According to 2014 fire statistical yearbook in the National Fire Data System, a main cause of fire is electrical fire except carelessness fire. Joint/contact badness is the one of the main cause of electrical fire. Furthermore, power relays which are used in electric panel board, motor control center and automation controller, are main element of automation system in the industry field. Overload, voltage unbalance and open-phase due to joint/contact badness of terminal make electric accidents or electrical fires. In order to prevent joint/contact badness of terminal, this paper proposes a sensing circuit of chattering, tracking, arc current, voltage unbalance and open-phase etc. Some experimental tests of the proposed apparatus confirm practicality and validity of the theoretical results.

  • PDF

Effects of Knee Joint Muscle Fatigue and Overweight on Shock Absorption during Single-Leg Landing of Adult Women (성인 여성의 외발 착지 동작 시 무릎관절 근육 피로와 과체중이 충격 흡수에 미치는 영향)

  • Kim, Tae-Hyeon;Youm, Chang-Hong
    • Korean Journal of Applied Biomechanics
    • /
    • v.24 no.1
    • /
    • pp.59-66
    • /
    • 2014
  • The purpose of this study was to investigate the effects of knee joint muscle fatigue and overweight on shock absorption during single-leg landing of adult women. Written informed consent forms, which were approved by the human subject research and review committee at Dong-A University, were provided to all subjects. The subjects who participated in this study were divided into 2 groups: a normal weight group and an overweight group, consisting of 15 young women each. Both the normal weight group and the overweight group showed that use soft landing and ankle dominant strategy. The peak vertical ground reaction force, the knee joint absorption power, and eccentric work done, as the increase of knee joint muscle fatigue level, showed a decrease. And the hip joint absorption power and eccentric work done, as the increase of weight, was less than the overweight group showed the normal weight group. In conclusion, the accumulation of the knee joint muscle fatigue and the increase of body weight may lead to an increased risk of injury during landing.

Vibration Power Flow Analysis of Coupled Co-planar Orthotropic Plates (동일 평면상에서 연성된 직교이방성 평판의 진동파워흐름해석)

  • Song, Jee-Hun;Park, Do-Hyun;Hong, Suk-Yoon;Kil, Hyun-Gwon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.9
    • /
    • pp.856-862
    • /
    • 2010
  • In this paper, the power flow analysis(PFA) method was developed to predict the vibrational responses of coupled co-planar orthotropic plates in frequencies ranging from medium to high. To cover the power transmission and reflection at the joint of the orthotropic plates, the wave transmission approach is applied with the assumption that all the incident waves are normal to the joint. Through numerical analyses, the power flow energy density and intensity fields of coupled co-planar orthotropic plates were compared with those of classical modal solutions by changing the frequency and internal loss factor, and they show good agreement in terms of the global decay and the attenuation patterns of the energy density.

The Effect of Wrist Stretching on Grasping Power and Musculoskeletal Disorders (손목 스트레칭이 파악력과 근골격계질환에 미치는 영향)

  • You, Heon-Jong
    • Journal of the Korea Safety Management & Science
    • /
    • v.24 no.3
    • /
    • pp.47-53
    • /
    • 2022
  • In order to conduct a study on the importance of the wrist joint, which causes a lot of pain among middle-aged people, in relation to work related to musculoskeletal disorders, the effect of stretching on grasping power was studied. In order to compare the grasping power of the wrist for middle-aged people in their 50s, the experiment was conducted by comparing before and after the wrist joint motion stretching. According to the experimental results of wrist gripping power for the control group and the experiment group on wrist gripping power, it was investigated that stretching did not change much in increasing wrist gripping power, but stretching application had an effect on wrist gripping power. In terms of preventing musculoskeletal accidents, reducing pain due to degenerative diseases, and preventing accidents, stretching seems to have an effect when approaching, so it is considered that continuous stretching before and after work is necessary. Therefore, it is suggested that stretching time secured quantitatively through safety and health education before work is necessary.

Optimization of Peltier Current Leads Cooled by Two-Stage Refrigerators

  • Jeong, Eun-Soo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.14 no.3
    • /
    • pp.94-101
    • /
    • 2006
  • A theoretical investigation to find thermodynamically optimum design conditions of conduction-cooled Peltier current leads is performed. A Peltier current lead (PCL) is composed of a thermoelectric element (TE), a metallic lead and a high temperature superconductor (HTS) lead in the order of decreasing temperature. Mathematical expressions for the minimum heat flow per unit current crossing the TE-metal interface and the minimum heat flow per unit current from the metal lead to the joint of the metal and the HTS leads are obtained. It is shown that the temperature at the TE -metal interface possesses a unique optimal value that minimizes the heat flow to the joint and that this optimal value depends on the material properties of the TE and the metallic lead but not the joint temperature nor electric current. It is also shown that there exists a unique optimal value for the joint temperature between the metal and the HTS leads that minimizes the sum of the power dissipated by ohmic heating in the current leads and the refrigerator power consumed to cool the lead, for a given length of the HTS.

Study for the development of assembly type joint boxes for extra high voltage power cables (초고압 전력 케이블용 조립식 접속상의 개발을 위한 연구)

  • Seo, J.Y.;Park, J.S.;Lee, H.S.;Oh, E.J.;Han, B.S.;Hahn, K.M.;Lee, K.C.;Jeon, S.I.;Han, M.K.;Lee, J.H.;Shin, P.S.
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.925-927
    • /
    • 1992
  • Since that the portion of failures caused by mis-installation of accessories is about 50% of whole failures in power transmission lines, the necessity of assembly type joint boxes, which have excellent installation capability and which can be electrically tested before installation, is gradually increasing. In this paper, we presented the results from the study from the point of design and the results of experiments using models. With the results of study, we could make it clear that the possibility of practical use of assembly type joint boxes instead of conventional molding type joint boxes is very high.

  • PDF

Electric Field Distribution Simulation of the Cable Joint Materials (케이블 접속재료의 전계분포 시뮬레이션)

  • Kim, Hyung-Joo;Byun, Doo-Gyoon;Shin, Jong-Yeol;Lee, Duk-Jin;Lee, Chung-Ho;Hong, Jin-Woong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11b
    • /
    • pp.601-604
    • /
    • 2001
  • The insulation materials of cables used for underground power transmission requires a higher insulating capability. and the most popular method to examine the cable is partial discharge test due to applying variation voltage. In the thesis. air void. silicone oil. of which may possibly exist real cables. are simulated by Electra 2D program. Also the relations between calculated field strength and the void defect type in the cable joint materails. In the modeling. electic field inner to the cable joint material composed by XLPE and EPDM is modeling simulated. We obtained the electric field distribution in void due to two conditions.

  • PDF

Electric Field Distribution Simulation of the Cable Joint Materials (케이블 접속재료의 전계분포 시뮬레이션)

  • 김형주;변두균;신종열;이덕진;이충호;홍진웅
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.601-604
    • /
    • 2001
  • The insulation materials of cables used for underground power transmission requires a higher insulating capability, and the most popular method to examine the cable is partial discharge test due to applying variation voltage. In the thesis, air void, silicone oil, of which may possibly exist real cables, are simulated by Electro 2D program. Also the relations between calculated field strength and the void defect type in the cable joint materials. In the modeling, eclectic field inner to the cable joint material composed by XLPE and EPDM is modeling simulated. We obtained the electric field distribution in void due to two conditions.

  • PDF

Characteristics of AC loss after jointing High Temperature Superconducting tape (High Temperature Superconducting tape의 joint 후 AC loss특성)

  • Kim, Hae-Joon;Sim, K.;Cho, J.;Jung, H.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.931-932
    • /
    • 2007
  • Specially, High Temperature Superconducting power-transmission cable(HTS cable), 3-phase 100m long, 22.9kV class HTS power transmission cable system have been developed by Korea Electrotechnology Research Institute (KERI) and LS cable Ltd. that is one of 21st century frontier project in Korea. This cable was installed in KEPCO(Go-chang) testing site. In case of manufacturing HTS cable, superconducting joint is very important because they need very long tapes. Therefore, this paper gives some investigation of AC Loss in joined HTS tape by using several joint methods. Finally, this paper was shown background data for the form of HTS cable joint.

  • PDF