일산화탄소 농도 예측 기능을 사용한 터널 환기 제어 알고리즘 (A Tunnel Ventilation Control Algorithm by Using CO Density Prediction Algorithm)

  • 한도영;윤진원
    • 설비공학논문집
    • /
    • 제16권11호
    • /
    • pp.1035-1043
    • /
    • 2004
  • For a long road tunnel, a tunnel ventilation system may be used in order to reduce the pollution level below the required level. To control the tunnel pollution level, a closed loop control algorithm may be used. The feedforward prediction algorithm and the cascade control algorithm were developed to regulate the CO level in a tunnel. The feedforward prediction algorithm composed of the traffic estimation algorithm and the CO density prediction algorithm, and the cascade control algorithm composed of the jet fan control algorithm and the air velocity setpoint algorithm. The verification of control algorithms was carried out by dynamic models developed from the actual tunnel data. The simulation results showed that control algorithms developed for this study were effective for the control of the tunnel ventilation system.

대단면 지하 석회석 광산내 무풍관 국부통기 최적화 연구 (Optimization of the Unducted Auxiliary Ventilation for Large-Opening Underground Limestone Mines)

  • 응우엔반득;이창우
    • 터널과지하공간
    • /
    • 제29권6호
    • /
    • pp.480-507
    • /
    • 2019
  • 본 논문은 무풍관 선풍기를 이용한 대단면 갱내 국부통기시스템의 최적화를 목적으로 한다. 갱내 맹갱도 형태의 작업공간을 대상으로 일련의 CFD분석과 현장실험을 수행하였다. 선풍기 위치, 운전방식 및 배치가 최적화의 주요 대상변수이다. 국부선풍기에서 토출되는 제트류는 대부분의 경우, 풍속이 15m/s이상으로 고속이므로 토출 후 갱도 바닥, 내벽, 천정 그리고 다른 선풍기에서 토출되는 제트류와 충돌할 가능성이 있다. 따라서 충돌시 상당한 에너지 손실이 발생하므로 통기 효율이 급격히 저하될 수 있다. 본 논문에서 최적 선풍기 간격은 제트류가 충돌 없이 최대의 유동거리를 유지할 수 있는 거리로 정의하며, 반면 단면상의 최적 위치란 갱도내벽과의 충돌 가능성이 최소화된 위치로 정의하였다. 따라서 선풍기 설치위치의 최적화는 통기의 효율뿐만 아니라 에너지 비용 또한 최소화가 가능하다. 3차원 CFD분석을 위하여 다양한 갱내 맹갱도 작업공간을 가정하였다. 무풍관 국부통기의 설계 및 최적화를 위하여 풍속 및 CO농도 분포를 CFD분석하였으며 동시에 비교 목적으로 현장실험을 수행하였다. 본 논문의 궁극적인 목적은 풍관을 사용하기 않는 국부통기시스템을 최적화함으로써 대단면 맹갱도 작업공간에 고효율, 저비용 국부통기를 가능케하여 깨끗하고 안전한 작업환경을 확보하기 위함이다.

제트홴에 의해 형성되는 터널내 유동의 실험 및 수치적 해석 (Numerical and Experimental Analysis of Tunnel Flow Induced by Jet Fan)

  • 김정엽;양상호
    • 한국유체기계학회 논문집
    • /
    • 제13권3호
    • /
    • pp.59-64
    • /
    • 2010
  • To analyze the three-dimensional flow in tunnel caused by operation of jet fan, both experimental and computational studies have been conducted. The experimental analysis of tunnel flow induced by jet fan is conducted on a real-scale apparatus with jet fan and tunnel, and air velocity at the monitoring points is measured for variation of fan's RPM. The three-dimensional numerical analysis including tunnel and jet fan is carried out for the same geometric configuration as the experimental analysis. The experimental and computational results are compared to examine the applicability of the numerical method.

Hot Smoke Test를 이용한 주차장 환기설비의 제연 성능평가 (Evaluation of Smoke Control Performance of Ventilation System Using by Hot Smoke Test)

  • 정석환
    • 한국방재안전학회논문집
    • /
    • 제12권2호
    • /
    • pp.47-56
    • /
    • 2019
  • 주차장 화재 시 다량의 연기 발생으로 소방대원이 화점에 진입하기 곤란한 문제점을 극복하고자 최근 주차장 환기 목적으로 설치된 급 배기팬과 유인팬(Jet fan)을 이용하여 연기를 배출하는 방법을 이용하고 있다. 본 연구에서는 급배기팬만 동작하는 조건과 유인팬이 함께 동작하는 2가지 조건에서 연기층의 유동변화를 CCTV를 이용하여 관찰하였으며, 또한 hot smoke test가 주차장 환기 성능평가 방법으로서의 적정성을 평가하기 위해 플럼 주위의 온도를 Alpert eq.과 비교 분석하였다. 그 결과 jet fan을 동시에 동작시키는 경우 연기층이 교란될 수 있음을 확인할 수 있었으며, 그로인하여 초기 피난 장애 우려가 있을 것을 것으로 분석되었다. 다만, jet fan이 추가로 작동됨에 따라 배기성능은 향상되는 것을 관찰용 CCTV로 확인할 수 있었으며, 이는 진압전술을 펴는데 도움이 될 것으로 판단된다. 플럼 주변의 온도를 측정하여 Alpert eq과 비교한 결과 Plume 중심축에서 약 $2^{\circ}C$ 낮고 연기가 배출되는 방향으로 8 m에서는 $9.0^{\circ}C$ 높은 것으로 분석되었다. Plume 주변의 온도 측정 결과는 AS 4391-1999의 예상 최대 온도보다 낮았고 실험으로 인한 예상 온도 위험을 초과하지 않았다. 이 결과와 같이 고온 연기 시험의 진행으로 인한 온도 위험성이 예측 가능하기 때문에 관련 기준이 없는 주차장의 연기 제어 성능 평가를 위한 일반적인 평가 방법 중 하나로 활용 가능할 것이다.

도로터널 환기/제연 시스템 시뮬레이션 (A NUMERICAL STUDY OF THE VENTILATION AND FIRE SIMULATION IN A ROAD TUNNEL)

  • 박종택;원찬식;허남건;차철현
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2005년도 추계 학술대회논문집
    • /
    • pp.207-212
    • /
    • 2005
  • In designing a ventilation system of a road tunnel, a possibility of using the system as a smoke control system in case of a tunnel fire has to be considered. In the present study, a numerical simulation on ventilation system is performed considering jet fan operations and moving traffic. A fire-mode operation by reversing some fan operations in case of a tunnel fire is also simulated. The results show that ventilation operation can control the pollutants effectively, and fire-mode operation can control smoke and temperature effectively to prevent a disaster.

  • PDF

도로터널에서 종류식 환기 시설의 운전 방안 (An Operation Methed for Longitudinal Flow Ventilation System in a Road Tunnel)

  • 김태형;황인주;홍대희;정종승;정종경
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집B
    • /
    • pp.87-92
    • /
    • 2001
  • In automobile highway tunnels, in order to maintain a suitable environment for drivers and traffic, visibility in the tunnel must be maintained, and the concentrations of poisonous substances including carbon monoxide must be kept at or below allowable levels. For this reason, in long tunnels and tunnels with heavy traffic, ventilation facilities are installed. When the ventilation facilities are run at full capacity, the environment in the tunnel is obviously adequately maintained, but this consumes a great deal of electric power. Consequently, a central problem in highway tunnel ventilation control systems is to keep the pollution concentration at or below the allowable level, and thus provide a safe environment for traffic, while consuming as little electricity as possible. This paper introduces an operation method of longitudinal flow ventilation systems with jet-fan, dust collector and vertical ducts.

  • PDF

중규모터널 방재용 제트팬 초기 가동시간에 관한 연구 (A Study on Jet Fan Start Time in Medium-Length Tunnel Fires)

  • 김두영;이창우
    • 터널과지하공간
    • /
    • 제20권6호
    • /
    • pp.465-474
    • /
    • 2010
  • 중규모 터널(연장 1 km 이내) 건설은 최근 매년 30% 이상의 증가율을 보이고 있으나 환기 및 방재시설 설치기준은 제정되어 있지 않은 상태라 장대터널을 대상으로 한 설치기준을 따르고 있다. 이에 따라 중규모터널 환기 및 방재시설의 최적화 노력이 요구되고 있다. 본 연구에서는 중규모 터널 내 20 MW 규모의 화재 시 발생하는 화재연 역류거리, 고온 열기류 확산범위, 가시거리 20 m 이하(상류) 구간분포, 임계풍속 확보여부, 대피시간 등을 CFD 분석을 통해 방재팬의 적정 초기 가동시간을 도출하여 방재시스템의 최적운전 방안의 제시를 목적으로 한다.

CFD 툴을 활용한 패키지형 수소충전시스템의 안전성 향상 연구 (A Study on the Safety Improvement by CFD Analysis for Packaged Type Hydrogen Refueling System)

  • 황순일;강승규;허윤실
    • 한국수소및신에너지학회논문집
    • /
    • 제30권3호
    • /
    • pp.243-250
    • /
    • 2019
  • In this study, to ensure the safety of the packaged hydrogen refueling system, the improvement plan was derived by using 3-dimensional CFD program (FLACS). We also confirmed the effectiveness of risk reduction and the suitability of safety standard. By ventilation performance evaluation according to the position of the vent, it demonstrated that the vent should be installed at the ceiling to safely ventilate without stagnation of the leaked gas. In case of ventilation system according to KGS standard, risk situation could be resolved after about 5 minutes in the worst leaked condition. The result showed that jet fire and explosion inside the packaged system could affect the surrounding facilities. This proves that the standard for installing flame detectors, emergency shut down system and protection wall is appropriate.

제트팬 설치 간격과 재유입 현상 분석을 위한 모형실험 (Model Test for the Determination of Distances between Jet-fans and Analysis of Recirculation)

  • 권오상;윤찬훈;윤성욱;김진
    • 한국터널지하공간학회 논문집
    • /
    • 제8권4호
    • /
    • pp.335-344
    • /
    • 2006
  • 국내에서 제트팬 설치 간격 기준으로 사용되고 있는 일본도로공단 기준은 제트팬의 구경에 따라 설치간격을 제시하고 있지만 국제 상설도로 협회(PIARC)에서는 터널 직경에 10배를 유지할 것을 권장하고 있다. 이 기준들에 의해 결정된 설치 간격은 최대 약 2배 정도의 차이를 나타내고 있으며 이러한 설치 간격의 차이는 터널 환기 방식 선정에 불리한 요건으로 작용될 수 있기 때문에 터널 내부의 기류분석을 통한 적정 설치 간격 기준이 필요하다. 본 논문에서는 Froude 상사이론에 기초하여 아크릴 재질의 축소비 1/40의 모형 터널(직경 215mm, 연장 6.9m)과 모형 제트팬(구경 26.3mm, 31.6mm)을 제작하여 터널 내부에서의 기류분석을 위해 터널연장을 따라서 압력과 속도의 변화를 측정하였고, 제트팬 가동시 제트팬 주위에서 외부 공기의 영향으로 발생될 수 있는 재유입 현상을 확인하기 위해서 제트팬 주변에서 압력변화를 측정하였다. 모형실험 결과에서는 터널 내부기류는 제트팬 구경에 영향을 받지 않고 터널직경에 약 9배 정도가 되는 지점에서 압력과 속도의 변화가 안정되는 것으로 나타났으며 제트팬이 가동되면서 발생되는 재유입 현상을 확인할 수 있었다. 이러한 결과를 통해 터널 내부에서의 제트팬 설치 시에는 터널 직경에 약9배 이상을 확보해야 한다고 판단된다.

공기구동 기체이젝터의 성능특성에 관한 연구 (A Study on the Performance Characteristics of Air Driven Gas Ejector)

  • 홍영표;윤두호;김용모;윤석훈
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제18권1호
    • /
    • pp.51-59
    • /
    • 1994
  • The gas jet pumps serve to preduce a vacuum or can be used as gas jet compressors. These are operated on the same principle as a steam jet vacuum pump : in the driving nozzle the pressure energy of the motive medium is converted into the kinetic energy. In the diffuser the driving jet mixes with the suction medium and the kinetic energy is reconverted into the pressure enegy. The application fields of gas jet ejectors are the evacuation of siphoning installations, the elevation of liquids, the production of vacuum filters, the vacuum supporting airlift system, the evacuation of the suction line of centrifugal pumps and the ventilation of the dangerous gases to the atmosphere. The performance of gas jet ejector is influenced strongly to velocity coefficient of motive nozzle, the distance between the motive outlet to the diffuser inlet and the dimensions of diffuser. This study is performed for the computer aided design of gas jet ejectors in future. Through the present experiments, it is known that the velocity coefficient of the motive air nozzle ranges from 0.91 to 0.95 and the maximum efficiency of gas jet ejector is 24.6%.

  • PDF