• Title/Summary/Keyword: Jet ventilation

Search Result 82, Processing Time 0.022 seconds

A Study on a Graphical Method for Determining the Characteristics of Jet-fan Ventilation System using the Contour Map of Required Ventilation Rate in Local Highways (지역별 소요환기량 특성도를 활용한 제트팬 환기방식 가능 터널제원 결정연구)

  • 김효규;김화수;김종대;이창우
    • Tunnel and Underground Space
    • /
    • v.13 no.3
    • /
    • pp.235-243
    • /
    • 2003
  • Recent worldwide trends show that tunnel length is getting longer, and the demand for longitudinal ventilation system with jet-fans in highway tunnels has also increased mainly due to the economic reasons. Improvements in vehicle engine subsequently reduced required ventilation rate(Qreq) which is the decisive factor in choosing the optimal ventilation system. Qreq contour map is a graph that defines the relationship among tunnel length, grade and required ventilation rate. It is important to understand the variation of Qreq in order to evaluate the characteristics of ventilation system with jet fans. Therefore this study aims at studying a graphical method for determining the characteristics of jet-fm ventilation system using Qreq contour map. Also, this study focuses on traffic composition on local highways.

Environmental Improvement in a Welding Factory by the Jet Ventilation System (제트 환기 시스템 도입에 의한 플랜트 기자재 용접장의 환경 개선 효과 분석)

  • Lim, Jung-Ho;Lee, Tae-Gu;Moon, Seung-Jae;Lee, Jae-Heon
    • Plant Journal
    • /
    • v.4 no.2
    • /
    • pp.66-72
    • /
    • 2008
  • In this inquiry, I would suggest jet ventilation system for effective elimination of welding flaw at machinery material welding shop on plant and evaluate the airstream on inner space and property of welding flaw's density through the examination. We can know outer atmosphere inflows at the speed of about 0.05m/s from western entrance in case of stopping the jet ventilation system, but airstream is accumulated on entire space. At height of worker's breathing surface(Ground Level = 1.5 m, below of GL) and welding work center, density of welding flaw on upper part(GL = 12m) is appeared 4 times higher than outer atmosphere at surplus range besides nearby of western entrance. At operation of jet ventilation system, since the smooth air current transfer at inner space and exhaust effect the wind speed is maintained at 0.932 m/s at the point of height of worker's breathing surface on inner space and it's concluded about the working conditions have been better than before operation of jet ventilation system because of that results show that inner space density of welding flaw at height of worker's breathing surface is 40.5%, and in the work shop, it is 20.3% at upper part.

  • PDF

Ventilation Analysis According to Jet Fan Location in Curved Long Road Tunnel (제트 팬 위치에 따른 곡선형 장대터널의 환기해석)

  • Byun, Ju-Suk;Kang, Shin-Hyung;Kim, Ji-Sung;Lee, Jin-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.9
    • /
    • pp.669-678
    • /
    • 2007
  • In this study, the ventilation characteristics is investigated numerically of the longitudinal ventilation method in the curved long road tunnel. Numerical work has been conducted for the jet fan location by utilizing the commercial finite-volume code, FLUENT. Configuration of the tunnel is three-lane, 1600 m long, $120m^2$ in area, 3000 m curvature radius. The velocity profile, distribution of mono-dioxide carbon and flow rate of air are examined in the tunnel. Through the analysis, it is found that the difference of ventilation flow rate Is a little by the jet fan location, but tunnel outlet setup (CASEIII) of jet fans is the most efficient concerned with CO concentration.

Development of Vehicle Tunnel Ventilation System (도로터널 환기시스템 개발연구)

  • Lee, Chang-Woo
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.71-74
    • /
    • 2008
  • This paper aims at studying the key design elements for the optimal ventilation system design, developing the design models and suggesting the design guidelines. The key elements include the basic exhaust emission rate, wall friction coefficient, vehicle drag coefficient and slip streaming effect, jet fan operating efficiency, natural ventilation force and installation scheme for jet fans and ventilation monitors in tunnel. The design models developed in this study are one-dimensional ventilation simulator to analyze the air flow, pressure profile and pollutant dispersion inside and outside tunnel, expert model to choose the optimal ventilation method, and the ventilation characteristic chart to evaluate the preliminary ventilation system. The study results are reflected in the design guideline for road tunnel ventilation system.

  • PDF

Numerical Analysis to Predict Air Flow Phenomena in a Road Tunnel (도로 터널내의 공기유동 양상을 예측하기 위한 수치해석)

  • Choi, In-Su;Park, Byung-Duck;Youn, Il-Ro
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.5 no.4
    • /
    • pp.313-320
    • /
    • 2002
  • A 2-dimensional $k-{\varepsilon}$ numerical model was developed to explore the effects of vehicle movement, jet fan and wind speed for the ventilation of road tunnels. To consider the temperature distribution in the tunnel, the energy equation was solved with a source term of the energy exhausted from vehicles. Although the tunnel ventilation can be made by the piston effect of vehicle movement, an additional ventilation is necessary when a head wind is existing. Jet fans may assist the air flow in the tunnel. However, more efficient ventilation system should be necessary, because the exhaust gas from vehicles flow along the road surface and it cannot be diffused in the longitudinal tunnel.

  • PDF

Numerical Analysis on the Effect of Parameters that Affect the Flow Rate through the Tunnel with Jet Fan Ventilation System

  • Kim, Sa-Ryang;Hur, Nahmkeon;Kim, Young-Il;Kim, Ki-Jung
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.11 no.4
    • /
    • pp.178-187
    • /
    • 2003
  • In this study, ventilation flow rate and pressure rise through a tunnel are simulated numerically using computational fluid dynamics (CFD) for various conditions such as roughness height of the surface of tunnel, swirl angle and hub/tip ratio of jet fan, and entrance and exit effects. By using a modified wall function, friction factor can be predicted with respect to the Moody chart within 10% of error for the circular pipe flow and 15% for the present tunnel. For more accurate design, the effect of the swirl angle and hub/tip ratio of jet fan, which is not included in the theoretical equation of pressure rise by jet fan needs to be considered.

A numerical study on the ventilation characteristics of rainfall in road tunnel (강우변화를 고려한 도로터널의 환기특성에 관한 수치해석)

  • Lee, Ho-Hyung;Lee, Seung-Chul
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.17 no.3
    • /
    • pp.341-351
    • /
    • 2015
  • When rainfall occurred on road tunnel, that is likely to have influence upon ventilation force in the tunnels but the tunnels ventilation system did not consider factors of rainfall. Thus, this study investigated effects of rainfall upon ventilation force in the tunnels at no rainfall and changing of rainfall by 3 dimensional numerical method. Flow rate into road tunnels decreased as many as 52.34% at rainfall of 150 mm/hr, and pressure drop of road tunnel between entrance and exit decreased as many as 22.22%, so that rainfall had influence upon ventilation force in the tunnel. The number of necessary jet fan in road tunnels is 12 at no rainfall but, when rainfall of 80 mm/hr on road tunnels, the number of necessary jet fan in road tunnels is 16, when rainfall of 150 mm/hr on road tunnels, the number of necessary jet fan in road tunnels is 17. So, factor of rainfall should be considered at estimation of ventilation system of road tunnel.

A study on the ventilation control method of road tunnel for small vehicles (소형차 전용 도로터널의 환기기 제어방안에 대한 연구)

  • Ryu, Ji-Oh;Lee, Hu-Young;Chang, Ji-Don
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.6
    • /
    • pp.749-762
    • /
    • 2019
  • In recent years, in urban areas, underground of roads are being promoted in order to resolve traffic congestion and to secure green spaces, and due to the low ratio of large vehicles, they are planned or constructed as road tunnels for small cars only. In addition, the tunnels being built in the city is a tendency to be enlarged to play the role of main roads. Accordingly, the capacity of the ventilation system is increasing and various ventilation methods are required, and the importance of maintenance after the completion of the tunnel such as the operating cost of the ventilation system is emphasized. Therefore, the need for optimization of the operation stage for reducing the power consumption of the ventilation system and the study of the ventilation system operation control logic is increasing. In this study, the study on the necessity of the optimization of operation stage and control logic of the ventilation system was carried out to realize the energy-saving operation for the small car only passing through tunnels which is applied of ① jet fan and combination ventilation system (② jet fan + air purifying equipment, ③ jet fan + vertical shaft, ④ jet fan + supply air semi-transverse). As a result of this study, there can be various operating combinations in the case of the combined ventilation system, and even though the amount of ventilation air is the same, the operating power varies greatly according to the operating combinations. It was found that operating the axial fan first rather than the jet fan first operation method has an effect on power saving.

High Frequency Jet Ventilation via Cricothyroid Membrane Puncture under Microlaryngoscopic Surgery (미세 후두현미경술시 윤상갑상막천자를 통한 고빈도 제트환기법)

  • 양훈식;김용주;김춘길
    • Korean Journal of Bronchoesophagology
    • /
    • v.1 no.1
    • /
    • pp.109-115
    • /
    • 1995
  • High frequency Jet ventilation (HFJV) via cricothyroid membrane puncture contols frequency of ventilation as 20-200/min and persuits adequate gas exchange. HFJV was known to have advantages such as improvement of PaO$_2$, lesser barotrauma, stable hemodynamic effects, good operative field and lesser movement of head. The purpose of this study was to clarify the advantages of HFJV in cases of microlaryngeal surgery which operating time was expected even within 30 minutes. Twenty-eight patients were divided two groups : 1)control group : general endotracheal Intubation anesthesia. 2)experimental group : HFJV via cricothyroid membrane puncture with intravenous anesthesia, frequency 40/min, I/E ratio 40%, driving pressure 40 psi. We analyzed blood pressure, arterial blood gas, score of general condition and recovery time after operation. In conclusion, HFJV via cricothyroid membrane puncture had a good score of general condition and rapid recovery of consciousness, although some accumulation of P$CO_2$and elevation of blood pressure.

  • PDF

The Jet-fan Model Test for a Road Tunnel Ventilation (도로터널 제트팬 모형 실험)

  • Ryu, Jae-Hong;Yoo, Young-Ho;Kim, Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.8
    • /
    • pp.630-640
    • /
    • 2003
  • As tunnel ventilation has recently been playing a major role in the tunnel construction and maintenance, longitudinal ventilation systems with jet fans have been utilized a great deal because they are economical and effective. However, due to the length of tunnels and heavy traffic, it is hard to take the field measurements. In this study, therefore, the computer simulation and the model experiment of producing a wind tunnel were carried out simultaneously and the results were compared. The ultimate objective of this research was to interpret the air flow pattern inside the tunnel with a jet-fan was set up, and to offer the useful data for jet-fan installation and operation. The experiment was carried out with varying the jet-fan diameters, location of installation, the discharge velocity. Result showed that as the initial static pressure came up with the negative pressure, the tunnel air flowed into the inside of tunnel from outside due to the entrainment-effect and the backflow-phenomenon by separation-effect was observed in the lower half part of the tunnel. As the jet-fan was getting closer to the tunnel wall, the entrainment-effect caused by the interaction with the wall was increased; however, the mixing distance and irregular flow section became longer, and also the air pressure loss generated by wall friction was large.