• Title/Summary/Keyword: Jet impingement heat transfer

Search Result 107, Processing Time 0.021 seconds

NUMERICAL ANALYSIS OF JET IMPINGING ON A MOVING PLATE (움직이는 평면으로의 충돌 제트에 대한 수치해석)

  • Kang, Soo-Jin;Seo, Seok-Won;Lee, Kwan-Soo
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.129-134
    • /
    • 2011
  • In this paper, the confined single slot jet impingement is investigated numerically. Although the geometry of the jet impingement is simple, the flow pattern of the jet impingement is complex and the numerical results of the jet impingement is affected much by numerical methods. The first goal of this study is to analyze the effects of Reynolds models and numerical spatial discretization schemes on the results of heat transfer performance and the flaw characteristics and to select the best method. Various versions of the low Reynolds number k-epsilon turbulence models are compared. Using the selected numerical method, the flow field and heat transfer characteristics of confined single slot jet impingement on a moving plate are analyzed.

  • PDF

Heat Transfer Characteristics on Impingement Surface with Control of Axisymmetric Jet ( 2 ) - With Acoustic Excitation - (원형제트출구 전단류 조절에 따른 제트충돌면에서의 열전달 특성 ( 2 ) - 음향여기된 제트 -)

  • Hwang, Sang-Dong;Lee, Chang-Ho;Cho, Hyung-Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.3
    • /
    • pp.373-381
    • /
    • 2000
  • The flow and heat transfer characteristics on the impingement surface can be controlled by the change of vortex with the acoustic excitation, because the flow characteristics of an impinging jet are affected strongly by the vortices formed at the jet exit. To investigate the effects of acoustic excitation, we measured the velocity, turbulent intensity distributions for the free jet and local heat transfer coefficients on a impingement surface. As the acoustic excitation, subharmonic frequency of excited frequency plays an important role to the control of the jet flow. If the vortex pairings are promoted by the acoustic excitation, turbulence intensity of the jet flow is increased quickly. On the other hand if the vortex pairings are suppressed, the jet flow has low turbulence intensity at the center of the jet. Therefore, the low heat transfer rates are obtained on the impingement plate for a small nozzle-to-plate distance. However, it has high heat transfer rates at a large distance between the nozzle and plate due to the increasing of potential-core length.

Effect of nozzle geometry on heat transfer of confined slot jet impingement on a flat plate with square rods (사각봉이 배열된 슬롯제트 충돌면에서 노즐형상이 열전달에 미치는 영향)

  • Chung, In-Kee;Park, Si-Woo;Ko, Wan-Wook
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.272-277
    • /
    • 2000
  • The heat transfer characteristics of confined turbulent slot jet impingement on the flat plate with square rods(turbulence promoter) have been experimentally investigated at different nozzle configuration. The effects of jet Reynolds number (Re=3900, 5800, 7800, 9700), dimensionless slot-to-plate distance(H/B=4, 6, 8) and clearance(c) between square rods and the plate were examined. Measurement of heat transfer rate were conducted using naphthalene sublimation technique. When square rods were inserted over the heat transfer surface, heat transfer rate was slightly increased in the wall jet region and the sharp-edged orifice nozzle was heigher than squared orifice nozzle.

  • PDF

Heat Transfer Characteristics of Confined Slot Jet Impingement on a Flat Plate with Square Rods (사각봉이 배열된 슬롯제트 충돌면에서의 열전달 특성)

  • Chung, In-Kee;Park, Si-Woo
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.119-124
    • /
    • 2000
  • The heat transfer characteristics of confined turbulent slot jet impingement on the flat plate with square rods(turbulence promoter) have been experimentally investigated. The effects of jet Reynolds number (Re=3900, 5800, 7800, 9700), dimensionless slot-to-plate distance(H/B=4, 6, 8) clearance(c) between square rods and the plate, and the length(d) of a side of the square rod were examined. Measurement or heat transfer rate were conducted using naphthalene sublimation technique. When square rods were inserted over the heat transfer surface, heat transfer rate was slightly increased in the wall jet region.

  • PDF

Comparative Study of the Steady State and Transient TSP Techniques in the Heat Transfer Measurement by an Inclined Impingement Jet (경사 충돌 제트 열전달 실험에서 정상 상태와 천이 TSP 기법의 비교 연구)

  • Jo, Yong-Hwa;Nho, Young-Cheol;Lee, Yong-Jin;Kwak, Jae-Su
    • The KSFM Journal of Fluid Machinery
    • /
    • v.15 no.1
    • /
    • pp.5-12
    • /
    • 2012
  • In this paper, the heat transfer coefficient measurement techniques using TSP(temperature sensitive paint) were introduced and the results of a comparative study on the heat transfer coefficient measurement by steady state and transient TSP techniques were discussed. The distributions of heat transfer coefficient by a single $60^{\circ}$ inclined impingement jet on a flat surface were measured by both techniques. Tested Reynolds number based on the jet diameter (d) was 30,000 and the distance between jet exit and target plate (L) was fixed at 10d. Results showed that the measured Nusselt number by both techniques indicated significant difference except near the center of impingement jet. Also, the heat transfer coefficients measured by the transient TSP technique were affected by the reference temperature of the jet. Based on the measured data, characteristics of both TSP techniques were analyzed and suggestions for applying them were also given.

Heat transfer coefficient measurement in the Blockage channel with Repeated Jet Impingement (반복된 제트 충돌을 갖는 내부 유로의 평균 열전달 계수 측정)

  • Park, Seoung Duck;Lee, Ki Seon;Kim, Sug Bum;Jo, Yong Hwa;Jeon, Chang Soo;Kwak, Jea Su;Huh, Jae-Sung
    • Journal of Aerospace System Engineering
    • /
    • v.2 no.4
    • /
    • pp.7-12
    • /
    • 2008
  • Averaged heat transfer coefficients were measured in a turbine blade internal cooling passage model with three blockage walls. Each blockage wall was equipped with 9 staggered holes or slots in order to create different shaper of repeated jet impingement. The effect of jet shape on the averaged heat transfer coefficient was studied by the copper-thermocouple method and three Reynolds number of 10,000, 20,000, and 30,000 were tested. Results showed that the repeated stagger jets could increase the averaged heat transfer coefficient by at least 9 times compared to the smooth channel cases. Due to the large pressure drop induced by the repeated jet impingement, the thermal performance was less than 1 for all cases and decreased as the Reynolds number increased. Among the tested cases, the widest slot showed the best thermal performance. The measurement results showed that the thermal performance of the heat transfer augmentation by repeated stagger jets could be improved by altering the jet shape, and other shape of impingement jet will be studied in near future.

  • PDF

Determination of mass flow rate, jet temperature and heating time in mold surface heating technology using hot jet impingement (고온제트에 의한 금형표면 가열기법에서의 유량, 온도, 가열시간의 결정)

  • Choi, Sung-Ju;Yoo, Young-Eun;Kim, Sun-Kyoung
    • 한국금형공학회:학술대회논문집
    • /
    • 2008.06a
    • /
    • pp.135-139
    • /
    • 2008
  • Development of surface heating technology using hot jet impingement onto mold inner surface for improvement of pattern transcription. This study is focused on how to control the parameters related to hot jet impingement. The mass flow rate, the jet temperature and the duration of the impingement are major parameters. The nozzle design and other geometric configurations also affect the heat transfer to the surface. In terms of heat transfer analysis, the most important number is the heat transfer coefficient, which is influenced by the mass flow rate, nozzle design, distance between the nozzle tip and the surface. In summary, several parametric studies using the developed model are conducted to investigate the effects of mass flow rate, jet temperature and Heating Time in Surface heating technology using hot jet impingement onto mold.

  • PDF

Effect of Cooling Water Temperature on Heat Transfer Characteristics of Water Impinging Jet (냉각수 온도에 따른 수분류 충돌제트의 열전달 특성 연구)

  • Lee, Jungho;Yu, Cheong-Hwan;Do, Kyu Hyung
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.23 no.5
    • /
    • pp.249-256
    • /
    • 2010
  • Water jet impingement cooling has been widely used in a various engineering applications; especially in cooling of hot steel plate of steelmaking processes and heat treatment in hot metals as an effective method of removing high heat flux. The effects of cooling water temperature on water jet impingement cooling are primarily investigated for hot steel plate cooling applications in this study. The local heat flux measurements are introduced by a novel experimental technique that has a function of high-temperature heat flux gauge in which test block assemblies are used to measure the heat flux distribution during water jet impingement cooling. The experiments are performed at fixed flow rate and fixed nozzle-to-target spacing. The results show that effects of cooling water temperature on the characteristics of jet impingement heat transfer are presented for five different water temperatures ranged from 5 to $45^{\circ}C$. The local heat flux curves and heat transfer coefficients are also provided with respect to different boiling regimes.

Heat/mass transfer characteristics of arrays of impingement jets using effusion holes (유출홀을 사용한 배열충돌제트의 열/물질전달 특성)

  • Yoon, P.H.;Hwang, S.D.;Cho, H.H.
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.125-131
    • /
    • 2000
  • The local heat/mass transfer coefficients for arrays of impinging circular air jets on a plane surface are determined by means of the naphthalene sublimation method. Spent fluid makes a crossflow in the confined space. The crossflow reduces heat/mass transfer at the small gap distance between the jet plate and impingement surface because of reentrainment of the spent fluid. The present study suggests a new exhaust system having effusion holes in the impinging jet plate. The spent air flow out after impingement just through effusion holes located in the upper plate. This system increases heat/mass transfer coefficients and uniformity for small gap distances$(H/d{\leq}2)$

  • PDF

Effect of Inclined Jet on Heat/Mass Transfer for Impingement/Effusion Cooling System (경사제트에 따른 충돌제트/유출냉각에서 열/물질전달 특성)

  • Hong, Sung-Kook;Rhee, Dong-Ho;Cho, Hyung-Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.4
    • /
    • pp.283-289
    • /
    • 2008
  • An experimental investigation was conducted to investigate the heat/mass transfer for impingement/effusion cooling system with inclined jet. Jets with inclined angle of 60 are applied to impingement/effusion cooling. At the jet Reynolds number of 10,000, the experiments were carried out for blowing ratios ranging from 0.0 to 1.5. The local heat/mass transfer coefficients on the effusion plate are measured using a naphthalene sublimation method. The result indicates that the inclined jet causes the non-uniform and low heat/mass transfer compared to the vertical jet. At stagnation region, the peak position is shifted from the geometrical center of injection hole due to Coanda effect and its level is higher than that of vertical jet due to increase in turbulence intensity by steep velocity gradient near the stagnation region. Further, the secondary peak region disappears because the interaction between adjacent wall jets weakens. When the initial crossflow occurs, the distorted heat/mass transfer pattern appears. As the blowing ratio (crossflow rate) increases, the heat/mass transfer distributions become similar to those of the vertical jet. This is because the effect of crossflow is dominant compared to that of inclined jet under high blowing ratio $(M{\geq}1.0)$. At low blowing ratio $(M{\leq}0.5)$, averaged Sh value is 10% lower than that of vertical jet, whereas its value at high blowing ratio $(M{\geq}1.0)$ is similar to that of vertical jet.